• 제목/요약/키워드: off-type

검색결과 1,836건 처리시간 0.033초

GIS내에 함유된 자유 도전성 파티클의 거동해석 (A Numerica analysis on the lift-off motion of Free Conducting Particle in GIS)

  • 이방욱;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1925-1928
    • /
    • 1996
  • In this work, the behavior of conducting wire type particles existing inside the cylinder type coaxial electrode has been systematically investigated by charge simulation method and electrostatic force analysis from the view point of the acquired charging before being lifted off into the gap under the high ac voltage. Spheroidal charge are adopted as a image charge for the CSM analysis in order to calculate the acquired charges of the particles which are erected on the surface of the outer electrode. For this purpose, different material of the particle and their lengths and diameters have been considered in view to calculate their lift-off field, acquired charge and to understand their effect on the lift-off voltage. The results imply that the particle lengths and diameter have an different influence on the particle behavior in GIS system.

  • PDF

2륜 자동차 촉매변환기내 배기가스 온도균일도 특성과 Light-Off에 관한 연구 (A Study on Characteristics of Exhaust Gas Temperature Uniformity and Light-off in Motorcycle Catalytic Converter)

  • 이중섭;정효민;이철재;정한식
    • 대한기계학회논문집B
    • /
    • 제31권6호
    • /
    • pp.507-513
    • /
    • 2007
  • This study represents the temperature uniformity in catalytic converter. Present research model type is a monolithic catalytic converter. This type was been widely used for complying the regulations of pollutant emissions from automobiles. The mean experimental parameters are engine speed and ceramics monolith in the catalytic converter. The experimental test engine model used was the 124.1cc motorcycle engine. The experimental study using thermal imaging method shows the megaphone type model has larger effective area than the basic model. The rate of effective area in the basic model is about 8.9 % and the megaphone type model are 41.52 %, 34.60 %, 33.43 %, 25.43 %, 17.82 % according to the diffuser angle $4^{\circ}\;to\;8^{\circ}$. In conclusion, the megaphone type monolithic converter has higher efficiency of reducing the pollution with less noise compared to the basic shape. We believe this will be very important as a design guide of the advanced motorcycle.

The Value of Preoperative CA 125 Levels in Prediction of Myometrial Invasion in Patients with Early-stage Endometrioid-type Endometrial Cancer

  • Atguden, Zeynep;Yildiz, Askin;Aksut, Hayri;Yalcin, Serenat Eris;Yalcin, Yakup;Uysal, Dilek;Yetimalar, Hakan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권2호
    • /
    • pp.497-501
    • /
    • 2016
  • Aim: To evaluate the relationship between pre-operative CA-125 levels and myometrial invasion in patients with early-stage endometrioid-type endometrial cancer. Materials and Methods: Two-hundred and sixty patients were diagnosed with endometrial cancer between January 2007 and December 2012. Of these, 136 patients with stage 1 endometrioid histologic-type and documented pre-operative serum CA-125 levels were included in the study. Age, preoperative CA-125 level, histologic grade, surgical grade, and presence of deep myometrial invasion were recorded. Additionally, 16, 20, and 35 IU/ml cutoff values were used and compared to evaluate the relationship between pre-operative CA-125 levels and myometrial invasion. Results: The average serum CA-125 level was $35.4{\pm}36.7$ in patients with deep myometrial invasion, and $21.5{\pm}35.8$ in cases without deep myometrial invasion. The relationship between the presence of deep myometrial invasion and CA-125 cut-off values (16, 20, 35 IU/ml) was statistically significant, although the correlation was weak (p<0.05). When the relationship between 16, 20 and 35 IU/ml CA-125 cut-off values and the presence of deep myometrial invasion was studied, specifity and sensitivity values were identified as: 0.60-0.68 for 16 IU/ml; 0.73-0.48 for 20 IU/ml; and 0.89-0.33 for 35 IU/ml. The sensitivity of 16 IU/ml cut-off value was higher when compared to other values. Conclusions: This study demonstrates that preoperative serum CA-125 values maybe used as a predictive test in patients with early stage endometrioid-type endometrium cancer, and as a prognostic factor alone. Further studies should be conducted to identify different CA-125 cut-off values in patients with low risk endometrial cancer.

ON-OFF형 비선형 제어기에 의한 서보 모터의 제어 (Servo Motor Control by On-Off Type Nonlinear Controller)

  • 김영복
    • 동력기계공학회지
    • /
    • 제2권2호
    • /
    • pp.55-59
    • /
    • 1998
  • In practice, the property of nonlinearity is contained in all physical systems. In other word, all physical systems are nonlinear to some degree. Therefore it is important that we acquires a facility for analyzing feedback control systems with varying degrees of nonlinearity. To operate the system linearly over wide range of variation of signal amplitude and frequency, the system requires components of an extremely high quality. Such a system would probably be impractical in the view points of cost, space and weight. In this context of view, it is worth noting that the nonlinearities may be intentionally introduced into a system in order to compensate for the effects of other undesirable nonlinearities or to obtain better performance than what could be achieved using linear element only. A simple example of an intentional nonlinearity is the use of a nonlinear damped system to optimize response in accordance with the magnitude of error. In this paper, an on-off type nonlinear controller is introduced and the applicability and validity of a simple on-off controller are presented by the experimental result.

  • PDF

상호참여형 원격진료를 위한 효율적인 객체관리 ((Efficient object control for remote medical examination of mutual participation type))

  • 김석수
    • 한국컴퓨터산업학회논문지
    • /
    • 제3권9호
    • /
    • pp.1245-1250
    • /
    • 2002
  • 본 논문은 누구나 참여할 수 있는 웹상에서의 시공간을 초월한 on-line 및 off-line 겸용모드의 지능형 원격 진료시스템으로서, 데이터베이스는 IIS 4.0 웹서버 상에서 ASP와 SQL을 연동한 구현하여 효율적인 자료처리를 위한 시스템 통합과 환자와 의사 및 한의사간의 on-line 상담, 그리고 off-line상에서의 진료와 환자가 지정한 약사로의 처방전 전송 및 조제, 그리고 진료데이터의 저장 및 검색으로 인한 반영구적인 진료데이터저장이 가능하며, 가족간의 진료데이터 검색 및 공유등 유전에 대한 치료효과 및 개인 병력관리를 통한 과거진료상황에 따른 빠른 치료효과 및 의사간의 협조진료등이 가능한 지능형 객체관리를 이용한 데이터베이스 구성이 되어있다.

  • PDF

高分子物質의 熱分解에 關한 硏究 (第1報) 熱天秤에 依한 硏究 (On the Pyrolysis of Polymers I. Thermogravimetric Analysis of Polymers)

  • 성좌경
    • 대한화학회지
    • /
    • 제7권2호
    • /
    • pp.96-105
    • /
    • 1963
  • The weight decrease curves of 18 kinds of polymers have been measured by thermobalance at the same condition where temperature is increased $1^{\circ}C$ per minutes under nitrogen or air atmosphere. The curves are further differentiated to obtain rate curve of weight decrease. Those curve offer a method to compare relative thermal stability, effects of oxygen or modes of thermal degradation of polymers qualitatively. The curves could be classified into following four types: Polystyrene, polymethylmethacrylate and acetal polymer belong to the first type. Those polymers depolymerize mainly into corresponding monomers, weight decrease curves are steepy up to perfect vaporization of polymers and rate curves show a relatively sharp peak. (Type I) Polyvinyl chloride represents the second type. This polymer decomposes with splitting off of hydrogen chloride. The thermogravimetric curve rises rapidly at first, then level off at the moderate weight decrease and gradually rises. Polyvinyl acetate also belongs to this class. (Type II) The modification of the second type is represented by polyester. The curve at the early stage is less steep, the leveling off at the next stage is less clear and the final rising of the curve is steeper than the normal second type. Polyamide, polyurethane, and polycarbonate belong to this type. (Type II') The thermal decomposition of the third type polymers is more complex than that of others. Various irregular chain scissions including side chain splitting and depolymerization to monomers occur simultaneously. The weight of the polymer decreases gradually and the rate curve does not show sharp peaks. Polyvinyl alcohol and diene polymers belong to this type. (Type III) Generally, polycondensation polymers are more stable toward heat than addition polymers and polymers having aromatic nucleus show good thermal stability. Polymers having tertiary carbon atoms such as polystyrene or polypropylene and acetal resin start decomposition under airatmosphere at the temprature below $50^{\circ}C$ or more of the temperature where the polymers start decomposition under nitrogen atmosphere.

  • PDF

N형 유기물질을 이용한 세로형 유기 발광트랜지스터의 제작 및 특성에 관한 연구 (Characteristics and Fabrication of Vertical Type Organic Light Emitting Transistors Using n-Type Organic Materials)

  • 오세용;김희정;장경미
    • 폴리머
    • /
    • 제30권3호
    • /
    • pp.253-258
    • /
    • 2006
  • 4 종류의 n형 유기 반도체 물질 F16CuPC, NTCDA, PTCDA, PTCDI C-8을 사용하여 ITO/n형 활성물질/Al gate/n형 활성물질/Al으로 구성되는 세로형 유기 박막트랜지스터를 제작하였다. 캐리어 이동도의 차이를 갖는 유기 물질의 종류와 유기 박막층의 두께 조절에 따른 유기 박막트랜지스터의 전류전압(I-V) 특성 및 전류의 온오프비에 미치는 영향을 조사하였다. PTCDI C-8을 사용한 세로형 유기 박막트랜지스터에서 낮은 구동전압과 높은 스위칭 특성을 보였다. ITO/PEDOT-PSS/P3HT/F16CuPc/Al gate/F16CuPc/Al으로 구성되는 발광트랜지스터를 제작하였고, 20 V에서 최고 0.054의 양자 효율을 나타내었다.

제주 신양리 연안 인공어초 주변해역에서 서식하는 어류의 종조성 및 계절변동 (Seasonal variation and species composition of fish species in artificial reefs in the Shinyang-Ri coastal waters off Jeju island, Korea)

  • 김재우;김하원;허성회;곽석남
    • 수산해양기술연구
    • /
    • 제47권2호
    • /
    • pp.118-127
    • /
    • 2011
  • This study was investigated seasonal variation and species composition of fish species at artificial reefs (octangle three-stage compartment type and dice type)and natural rock in the Shinyang-Ri coastal waters off Jeju Island with visual census method in January 2009, April 2009, July 2009, September 2009, December 2009, March 2010, June 2010, and September 2010. A total of 44 fish species was occurred, and the dominant fish species were Apogon semilineatus, Chromis notata, Trachurus japonicus, Sebastes thompsoni and Apogon doederleini. The number of individuals of fishes was higher at April 2009 and March 2010, however, lower at June 2010 and September 2010. The number of fish speices was higher at artificial reefs than those of at natural rock. Apogon semilineatus was dominant at octangle three-stage compartment type and the dice type artificial reefs, whereas Chromis notata was for natural rock. These results indicated that artificial reefs were good habitats for a variety of fish species in the Shinyang-Ri coastal waters off Jeju Island.

A New Shack-Hartmann Type Wavefront Sensor Using Liquid Crystal Panels

  • Xiaoxi, Chen;Xu, Liu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.528-530
    • /
    • 2005
  • In this paper, we present a new and practical method for achieving real-time wavefront measurement, dramatically increasing the resolution, dynamic range of Shack-Hartmann wavefront sensor and improving the wavefront reconstruction quality. In proposal method, a liquid crystal display panel (LCD) for the generation of an array of Fresnel microlenses is use instead of the static microlens array of the conventional Shack-Hartmann type sensor. An off-axis holographic microlens array is designed instead of the normal microlens array to increase the effective array and then the dynamic range. The focus properties of the off-axis lens are studied.

  • PDF

Measuring and Reducing Off-Target Activities of Programmable Nucleases Including CRISPR-Cas9

  • Koo, Taeyoung;Lee, Jungjoon;Kim, Jin-Soo
    • Molecules and Cells
    • /
    • 제38권6호
    • /
    • pp.475-481
    • /
    • 2015
  • Programmable nucleases, which include zinc-finger nucleases (ZFNs), transcription activator-like effector nucleases (TALENs), and RNA-guided engineered nucleases (RGENs) repurposed from the type II clustered, regularly interspaced short palindromic repeats (CRISPR)-CRISPR-associated protein 9 (Cas9) system are now widely used for genome editing in higher eukaryotic cells and whole organisms, revolutionising almost every discipline in biological research, medicine, and biotechnology. All of these nucleases, however, induce off-target mutations at sites homologous in sequence with on-target sites, limiting their utility in many applications including gene or cell therapy. In this review, we compare methods for detecting nuclease off-target mutations. We also review methods for profiling genome-wide off-target effects and discuss how to reduce or avoid off-target mutations.