• Title/Summary/Keyword: off-type

Search Result 1,837, Processing Time 0.025 seconds

Characteristics of Temperature Control in the Inverter Type Oil Coolers (인버터 타입 오일냉각기의 온도제어 특성에 관한 연구)

  • 이상호;이찬홍;박천홍
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.233-236
    • /
    • 2003
  • In this Paper, the temperature control error and cooling characteristics of inverter typ coolers are evaluated to predict application validity of coolers under heating pattern and amount The temperature control error of coolers small in 15~70% range of the max. cooling ability. At less than 15% of max. cooling ability has the inverter type cooler a basic temperature control error $\pm0.5^{\circ}C$ and acts as on/off type coolers. The inverter type cooler is unsuitable for precision temperature control under the complex heating pattern. But PID control of cooler including the heating system is an alternative for the case.

  • PDF

Research on Indoor Thermal Environment and Residents' Control Behavior of Cooling according to Household Type in Apartment (가구 유형에 따른 여름철 공동주택의 실내온열환경과 냉방 조절 행위에 관한 연구)

  • Bae, Chi-Hye;Bae, Nu-Ri;Chun, Chung-Yoon
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.89-96
    • /
    • 2008
  • This study measured the thermal environment and residents' control behaviors of cooing according to 3 groups of household type-families with preschool children, families of middle age and families of senior. The object of this study are to fmd the difference of the actual condition of indoor thermal environment and cooling control behavior by age or household type and to develop user oriented climate control system. The results were summarized as follows. When the age of members at household is younger, the indoor mean temperature and temperature that people turned off the air conditioner became lower. These different indoor thermal environment of each group means that younger generation is familiar with cooler from their early age and these early uses of cooler made them prefer cooler condition than family of senior. Therefore, this results show that different indoor thermal environment is influenced by factors such as household type and metabolism difference and so on.

Hole-filling Method to Enhance Viewing Characteristics for Multilayer Type 3D Display System U sing a DMD

  • Baek, Hogil;Choi, Sungwon;Kim, Hyunho;Choi, Hee-Jin;Min, Sung-Wook
    • Current Optics and Photonics
    • /
    • v.4 no.6
    • /
    • pp.545-550
    • /
    • 2020
  • We propose a hole-filling method to solve discontinuous depth representation and to reduce the visible seams and cracks that cause the limitation of the viewing angle of the three-dimensional (3D) image in the multilayer type 3D display system. The occlusion and the disocclusion regions between layers, such as the visible seams and cracks, are a major bottleneck of the multilayer type 3D display system to represent a volumetric 3D image by stacking multiple images. As a result, in the reconstructed 3D image, the visible seams and cracks appear as brighter overlapping and undesirable cut-off. In order to resolve the problems above, we applied the depth-fused effect to the sub-depth map generating algorithm and improve the viewing characteristics of the multilayer type 3D display. The experimental demonstrations are also provided to verify the proposed scheme.

The Performance Evaluation Analysis of PV System for Arch and Flat-Plate Type (평판형 및 아치형 태양광발전 시스템의 성능평가 분석)

  • Piao, Zheng-Guo;Choi, Youn-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1012-1018
    • /
    • 2015
  • The studies on the operating performance analysis or design about the fixed tilt angle flat-plate photovoltaic (PV) system are still lively going off. However the operating property analysis about the arch type PV system which means PV array were designed as round type is dissatisfied. In this paper, we theoretically established the factors which are cause of the deterioration in performance of arch type PV system. In addition, we use the Solar Pro simulation tools to design both flat-plate type and arch type 30kW PV systems. The simulations about arch type PV system applied two ways such as central inverter and string inverter were conducted. The performance ratio (PR) of the PV system with flat-plate type shows the highest value 74[%] when the tilt angle is 30°. In case of arch type, when applying central inverter method, PR value shows approximately 73[%] and no more difference with arch type of the PV array. This value shows 1[%] decrease compare with the flat-plate type. However when applying string inverter methods, the average PR value shows 80 % and 6% improved than the central inverter method.

Late Quaternary Sedimentation in the Yellow Sea off Baegryeong Island, Korea (한국 황해 백령도 주변해역 후 제4기 퇴적작용)

  • Cho, MinHee;Lee, Eunil;You, HakYoel;Kang, Nyen-Gun;Yoo, Dong-Geun
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.3
    • /
    • pp.145-153
    • /
    • 2013
  • High-resolution chirp profiles were analyzed to investigate the echo types of near-surface sediments in the Yellow Sea off the Baegryeong Island. On the basis of seafloor morphology and subbottom echo characters, 7 echo types were identified. Flat seafloor with no internal reflectors or moderately to well-developed subbottom reflectors (echo type 1-1 and 1-2) is mainly distributed in the southern part of the study area. Flat seafloor with superposed wavy bedforms (echo type 1-3) is also distributed in the middle part. Mounded seafloor with either smooth surface or superposed bedforms (echo type 2-1, 2-2, and 2-3) occurs in the middle part of the study area. Irregular and eroded seafloor with no subbottom reflectors (echo type 3-1) is present in the northern part of the study area off the Baegryeong Island. According to the distribution pattern and sedimentary facies of echo types, depositional environments can be divided into three distinctive areas: (1) active erosional zone due to strong tidal currents in the northern part; (2) formation of tidal sand ridges in response to tidal currents associated with sea-level rise distributed in the middle part; and (3) transgressive sand sheets in the southern part. Such a depositional pattern, including 7 echo types, in this area reflects depositional process related to the sea-level rise and strong tidal currents during the Holocene transgression.

Real-time epical transfer function measuring system with on- and off-axis nodal slide bench type for evaluating the camera lens (카메라 렌즈 평가용으로 제작된 nodal slide식 실시간 OTF 측정 장치)

  • Lee, Ji-Young;Song, Jong-Sup;Jo, jae-Heung;Chang, Soo;Rim, Cheon-Seog;Lee, Yun-Woo;lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.2
    • /
    • pp.92-97
    • /
    • 2002
  • A real-time OTF (optical transfer function) measuring system with on- and off-axis nodal slide bench type for the camera lens is fabricated and evaluated. It consists of a nodal slide bench including a T-bar for the OTF measurement of an off-axis object, two dimensional CCD (charge coupled device) with pixel of 9.9${\mu}{\textrm}{m}$$\times$9.6${\mu}{\textrm}{m}$ for real-time OTF measurment, and a collimating lens of focal length of 300 mm for the optimization of this system. The OTF system is corrected by using the OTF of a SIRA lens of fnumber of F/8 and focal length 50 mm. In order to confirm the reliability of the OTF system, two MTFs (modulus transfer functions) of CCTV & VIDEO lens (JAPAN, AVENIR-SE 2514) of focal length of 25mm and field of view 10.6$^{\circ}$are measured by the camera bench type OTF system of reference OTF system and the nodal slide bench type OTF system and compared with each other. As a result, these two values are agree well with each other within 4% from 0 1p/mm to 100 1p/mm.

Effects of irradiation periods on the Lettuce Growth (광원 조사기간이 상추생육에 미치는 영향)

  • Kim, Dong-Eok;Kim, Bong-Soo;Kim, Hyun-Bae;Yoon, Yong-Cheol;Kim, Chi-Ho;Kim, Hyeon-Tae
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.4
    • /
    • pp.459-466
    • /
    • 2012
  • The objective of this study is to observe growth pattern of grand rapids(lettuce) according to different dexperimental conditions for minimizing its growth period such as composition of nutrient, irradiation time of light source and cultivation mode. The culture of water spray type using seeds of grand rapids was performed during growth period of total 50 days. Experimental conditions consist of five compositions of nutrient (PW 0.5 mS/cm, PW 1.0 mS/cm, PY 0.5 mS/cm, PY 1.0 mS/cm, PW 2.0 mS/cm) and three irradiation times of light source (12h(on) / 12h(off), 18h(on) / 06h(off), 24h(on) / 00h(off)). Illumination was adjusted to ratio of 7:1:1 of red, blue and white color, respectively. Indoor environmental condition for cultivating grand rapids is as follows: temperature (19-$22^{\circ}C$), relative humidity (60-70%) and carbon dioxide (1,000-1,200 ppm). The data were obtained from five iteration tests. The maximum growth level was observed in the experimental condition of 18 hr(on) / 06 hr(off) and PY 1 mS/cm for 1st week of cultivation period, 24 hr(on) / 00 hr(off) and PY 1mS/cm for 2nd week of cultivation period, and 24 hr(on) / 00hr(off) and PW 1 mS/cm for 3rd week of cultivation period, respectively. On the contrary, the minimum growth level was observed in the experimental condition of 18 hr(on) / 06 hr(off) and PW 0.5 mS/cm for 1st week of cultivation period, 12 hr(on) / 12 hr(off) and PW 0.5 mS/cm for 2nd week of cultivation period, and 12 hr(on) / 12 hr(off) and PY 0.5 mS/cm for 3rd week of cultivation period, respectively. Based on the results obtained from this study, it is concluded that the growth level of grand rapids varied with different irradiation time of light source and composition ratio of nutrient according to cultivation period.

Cut-off Values of Waist Circumference and Body Mass Index for Metabolic Syndrome according to Sasang Constitution (대사증후군에 대한 사상체질별 허리둘레 및 체질량지수의 절단값에 대한 연구)

  • Choi, Jae-Wan;Yu, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.26 no.4
    • /
    • pp.365-378
    • /
    • 2014
  • Objectives This study was performed to investigate the cut-off values of abdominal circumference and Body Mass Index(BMI) according to Sasang Constitution. Methods A total of 1,773 persons, namely 440 male people and 1,333 female people, in ages from 40 to 69 years old, participated in this research. They are all included in the community based Genomic cohort in Wonju in years from 2006 to 2013. The diagnostic criteria of metabolic syndrome was used followed by the National Cholesterol Education Program in Adult Treatment Panel III (NCEP ATP III) and Asian pacific guideline for only abdominal obesity. Results The prevalence of metabolic syndrome was 34.8% for men and 37.6% for women in this research. Taeeumin was the highly significant risk type for the metabolic syndrome in both sexes. Cut-off values of abdominal circumference were 88.3 cm in men, 80.3 cm in women, and cut-off values of BMI were $24.2kg/m^2$ in men and $25.3kg/m^2$ in women. For men, cut-off values of abdominal circumference were 79.5cm in Soyangin, 88.8 cm in Taeeumin and 79.5 cm in Soeumin, and cut-off values of BMI were $23.2kg/m^2$ in Soyangin, $25.6kg/m^2$ in Taeeumin and $20.6kg/m^2$ in Soeumin. For women, cut-off values of abdominal circumference were 76.3 cm in Soyangin, 80.3 cm in Taeeumin and 76.8 cm in Soeumin, and cut-off values of BMI were $22.4kg/m^2$ in Soyangin, $24.9kg/m^2$ in Taeeumin and $21.3kg/m^2$ in Soeumin. Conclusions Although 90 cm in men, 80 cm in women as an Asian pacific guideline were regarded as quite approximate to the mean value of abdominal circumference and $25kg/m^2$ to BMI. But if the results could be allocated in terms of the Sasang constitutional method, the cut-off values for Soyangin and Soeumin should be lowered than now.

Determination of Unit Hydrograph for the Hydrological Modelling of Long-term Run-off in the Major River Systems in Korea (장기유출의 수문적 모형개발을 위한 주요 수계별 단위도 유도)

  • 엄병현;박근수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.4
    • /
    • pp.52-65
    • /
    • 1984
  • In general precise estimation of hourly of daily distribution of the long-term run-off should be very important in a design of source of irrigation. However, there have not been a satisfying method for forecasting of stationar'y long-term run-off in Korea. Solving this problem, this study introduces unit-hydrograph method frequently used in short-term run-off analysis into the long-term run-off analysis, of which model basin was selected to be Sumgin-river catchment area. In the estimation of effective rainfall, conventional method neglects the Soil moisture condition of catchment area, but in this study, the initial discharge (qb) occurred just before rising phase of the hydrograph was selected as the index of a basin soil moisture condition and then introduced as 3rd variable in the analysis of the reationship between cumulative rainfall and cumulative loss of rainfall, which built a new type of separation method of effective rainfall. In next step, in order to normalize significant potential error included in hydrological data, especially in vast catchment area, Snyder's correlation method was applied. A key to solution in this study is multiple correlation method or multiple regressional analysis, which is primarily based on the method of least squres and which is solved by the form of systems of linear equations. And for verification of the change of characteristics of unit hydrograph according to the variation of a various kind of hydrological charateristics (for example, precipitation, tree cover, soil condition, etc),seasonal unit hydrograph models of dry season(autumn, winter), semi-dry season (spring), rainy season (summer) were made respectively. The results obtained in this study were summarized as follows; 1.During the test period of 1966-1971, effective rainfall was estimated for the total 114 run-off hydrograph. From this estimation results, relative error of estimation to the ovservation value was 6%, -which is mush smaller than 12% of the error of conventional method. 2.During the test period, daily distribution of long-term run-off discharge was estimated by the unit hydrograph model. From this estimation results, relative error of estimation by the application of standard unit hydrograph model was 12%. When estimating by each seasonal unit bydrograph model, the relative error was 14% during dry season 10% during semi-dry season and 7% during rainy season, which is much smaller than 37% of conventional method. Summing up the analysis results obtained above, it is convinced that qb-index method of this study for the estimation of effective rainfall be preciser than any other method developed before. Because even recently no method has been developed for the estimation of daily distribution of long-term run-off dicharge, therefore estimation value by unit hydrograph model was only compared with that due to kaziyama method which estimates monthly run-off discharge. However this method due to this study turns out to have high accuracy. If specially mentioned from the results of this study, there is no need to use each seasonal unit hydrograph model separately except the case of semi-dry season. The author hopes to analyze the latter case in future sudies.

  • PDF