• Title/Summary/Keyword: off-pump

Search Result 300, Processing Time 0.036 seconds

Property Analysis for On/Off Surge of High-Voltage Condenser (고압콘덴서 개폐시 발생하는 써지의 특성 분석)

  • Hong, Sung-Taek;Lee, Eun-Chun;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.235-237
    • /
    • 2002
  • Whenever the large-capacitor and high-voltage pump motor is opened and closed, the power factor improvement condenser and the low-voltage equipment are often damaged by the sparking and the on-off power serge. In order to find the reason and resolve the problem, we have installed a transition wave recorder for obtaining the transient on-off power serge wave and a power disturbance analyzer for long-time monitoring. In this way we measured and analysed the condition of the high-voltage pump motor whenever it is opened and closed.

  • PDF

Three Dimensional Simulation Model of Fuel Delivery Jet Pump (연료 송출용 제트펌프 3차원 전산해석 모델)

  • PARK, DAIN;YUN, JIN WON;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.3
    • /
    • pp.308-314
    • /
    • 2017
  • Jet pump in automotive fuel tank module is used to deliver fuel to fuel pump so that the pump is operated without aeration in suction side. In this study, three dimensional simulation model of jet pump is developed to understand performance variation over design parameters. Performance of jet pump is also investigated experimentally in terms of operating pressures. The experimental data is used to verify the three dimensional simulation model of jet pump. Verification results show that the three dimensional simulation model of jet pump is about 1% error with experiment. The simulations are conducted in terms of throat ratio and primary flow induction angle. As the throat ratio is increased, the flux ratio is trade-off at 3 times of throat diameter. On the other hand, as primary flow induction angle is increased, vapor pressure inside the nozzle is decreased. In summary, the results show that liquid jet pump has to be optimized over design parameters. Additionally, high velocity of induced flow is able to evolve cavitation phenomena inside the jet pump.

"On-Pump" CABG on the Beating Heart - Two case report - (심폐바이패스하의 심박동상태에서 시행한 관상동맥우회로술)

  • 신종목;김기봉
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.480-483
    • /
    • 1999
  • The widely accepted method for coronary artery bypass grafting(CABG) is performing the distal coronary artery anastomoses on the flaccid and nonbeating heart with the aid of cardiopulmonary bypass(CPB) and cardioplegic arrest. However, current cardioplegic techniques are not consistent in avoiding myocardial ischemic damages especially in high risk patients undergoing CABG. In this regard, "Off-Pump" seems to be an ideal method for preventing myocardial ischemic damage and adverse effects during CPB. However, "Off-pump" CABG is not always technically feasible. We report 2 cases of "On-pump" CABG performed on the beating heart in high risk patients; The first patient had left ventricular dysfunction(Ejection Fraction=25%), and the second patient had cardiogenic shock after percutaneous transluminal coronary angioplasty.

  • PDF

Clinical use of Centrifugal Biomedicus Pump (Centrifugal biomedicus pump의 임상 응용)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1550-1555
    • /
    • 1992
  • From June 1989 to July 1992, we used centrifugal Biomedicus pump[CBP] in 20 patients In 9 cases, CBP was used as ventricular assistance after heart surgery for those who could not be weaned off bypass even with intra-aortic balloon counter-pulsation and with maximal inotropic support In 8 patients, CBP was used as partial left heart bypass during repair of aortic aneurysms or congenital aortic anomalies. And in 3 patients, CBP was used as vena caval bypass during resection of renal cell carcinoma with tumor extension into the inferior vena cava. In 2 of 9 patients with ventricular assistance, they were weaned off the device successfully after 16 hours and 7 days respectively. But the patients died of intracranial hemorrhage and sepsis, 7 and 29 days after weaning from cardiac support, respectively. In all the patients who underwent aortic of vena caval surgery using CBP as shunt, there were no complications such as postoperative bleeding necessitating reoperation, renal failure or neurologic sequelae. In conclusion, the centrifugal type of ventricular assistance may be potentially life saving treatment modality in patients with severe postoperative low cardiac output syndrome. The CBP can be safely employed for resection of renal cell carcinoma with vena caval tumor extension and for repair of aortic aneurysms.

  • PDF

Cabrol Technique Application in Off-pump Coronary Artery Bypass Grafting Using Radial Artery (인공심폐기를 이용하지 않는 관상동맥우회술 시 요골동맥을 이용한 Cabrol 술식의 응용)

  • Na, Chan-Young;Oh, Sam-Se;Kim, Soo-Cheol;Kim, Jae-Hyun;Jo, Won-Min;Seo, Hong-Ju;Lee, Cheul;Chang, Yun-Hee;Kang, Chang-Hyun;Lim, Cheong;Baek, Man-Jong;Whang, Song-Wok;Choi, In-Seok;Kim, Woong-Han;Park, Yoon-Ock;Moon, Hyun-Soo;Park, Young-Kwang;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.630-632
    • /
    • 2003
  • In off-pump coronary artery bypass grafting (CABG), multiple proximal anastomosis may increase the risk of cerebral embolism (air, debris) and aortic injury (dissection, pseudoaneurysm). Radial artery (RA) has no intraluminal valve such as saphenous vein. We applied Cabrol technique using aortic root replacement for proximal anastomosis in off-pump CABG. Cabrol technique using RA graft can reduce numbers of proximal anastomosis and reduce number of aortic manipulation in off-pump CABG. We report a Cabrol technique for proximal anastomosis in off-pump CABG with RA graft.

Hydraulic Design and Performance Evaluation of a Fuel Pump for a High Pressure Turbopump System (고압 터보펌프용 연료펌프의 수력설계 및 성능 평가)

  • Choi, Bum-Seog;Yoon, Eui-Soo;Oh, Hyoung-Woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.2 s.29
    • /
    • pp.31-38
    • /
    • 2005
  • A low NPSH and high pressure fuel pump has been designed for a turbopump system. The fuel pump has an axial inducer and a centrifugal impeller. A meanline method has been established for the preliminary design and performance prediction of pumps at design or off-design points. KeRC(Kelyish Research Center) carried out a model testing of the fuel pump with water as a working fluid at the reduced speed. Predicted performances by the method are shown to be in good agreement with experimental results for cavitating and non-cavitating conditions. The established meanline method can be used for the performance prediction and preliminary design of high speed pumps which have a inducer, impeller and volute. In the current study, the three dimensional viscous flow in the fuel pump was investigated through numerical computation. A modified design of the fuel pump was generated to improve pump performance by utilizing CFD results. The modified fuel pump was experimentally tested by ROTEM and KARI(Korea Aerospace Research Institute). The measured non-cavitating and cavitating performance showed a good agreement with designed performance.

Design of the Charge pump PLL using Dual PFD (듀얼 위상 주파수 검출기를 이용한 차지펌프 PLL 설계)

  • Lee, Jun-Ho;Lee, Geun-Ho;Son, Ju-Ho;Kim, Sun-Hong;Yu, Young-Gyu;Kim, Dong-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.20-26
    • /
    • 2001
  • In this paper, the charge pump PLL using the dual PFD to improve the trade-off between acquisition behavior and locked behavior is proposed. This dual PFD consists of a positive edge triggered PFD and a negative edge triggered PFD. The proposed charge pump shows that it is possible to overcome the issue of the charge pump current imsmatch by the current subtraction circuit. Also, this charge pump can suppress reference spurs and disturbance of the VCO control voltage. The proposed charge pump PLL is simulated by SPICE using 0.25${\mu}m$ CMOS process parameters.

  • PDF

Analysis of Risk Factors for Conversion from Off-Pump to On-Pump Coronary Artery Bypass Graft

  • Lim, Junghyeon;Lee, Won Yong;Ra, Yong Joon;Jeong, Jae Han;Ko, Ho Hyun
    • Journal of Chest Surgery
    • /
    • v.50 no.1
    • /
    • pp.14-21
    • /
    • 2017
  • Background: Off-pump coronary artery bypass (OPCAB) is performed worldwide, but significant risks are associated with conversion to on-pump surgery. Therefore, we evaluated the composite outcomes between an OPCAB group and a conversion group. Methods: From January 2008 to December 2012, 100 consecutive patients underwent OPCAB at Hallym University Sacred Heart Hospital, of whom 84 underwent OPCAB without adverse events (OPCAB group), and 16 were converted to on-pump surgery (conversion group). Early morbidity, early and long-term mortality, and major adverse cardiac and cerebrovascular events (MACCEs) were the primary and long-term composite endpoints. Results: The mean follow-up period was $55{\pm}26months$, with 93% of the patients completing follow-up. The composite outcomes in the OPCAB and conversion groups were as follows: early morbidity, 2.3% versus 12.5%; early mortality, 4.7% versus 0%; long-term mortality, 14.3% versus 25.0%; and MACCEs, 14.3% versus 18.8%, respectively. No composite endpoints showed statistically significant differences. Preoperative acute myocardial infarction (AMI) was identified as an independent risk factor for conversion (p=0.025). Conclusion: The conversion group showed no statistically significant differences in early mortality and morbidity, MACCEs, or long-term mortality compared with the OPCAB group. The preoperative diagnosis of AMI was associated with an increased number of conversions to on-pump surgery.

Effects of Preoperative Continuous Use of Aspirin and Plavix in off-pump Coronary Artery Bypass Surgery (아스피린과 플라빅스의 수술 전 지속적 사용이 무심폐기 하 관상동맥우회술에 미치는 영향)

  • Yi Gijong;Lee Kyo-Joon;Yang Hong-Seok;Ahn Ji-Young;Yoo Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.48-55
    • /
    • 2006
  • Background: The benefits of preoperative use of aspirin and plavix in coronary patients have been well documented. Due to their bleeding tendency, there have been many discussions about when to stop the antiplatelet agent before operation. We evaluated the effects of preoperative continuous use of aspirin and plavix in OPCAB patients. Material and Method: 123 patients underwent OPCAB from March, 2004 to Feb., 2005. We divided them into two groups; those who had continuous administration of aspirin and plavix during the preoperative period (n=45, 36.6$\%$) and those who discontinued them at least one day before the operation (n=78, 63.4$\%$). We then compared the platelet count, hemoglobin/hematocrit level, graft patency, postoperative bleeding and related complications, and operation time between the two groups. The patients were also divided into long-term users ($\geq$ 1 month) and short-term users (< 1 month), with the aforementioned factors equally compared. Result: There was no statistical difference between the two groups regarding postoperative bleeding, related complications, graft patency, operation time and mortality. Continuous users showed significantly low platelet levels on immediate post operation (p=0.02), postoperative day (POD) $\sharp$1 (p=0.002) and POD $\sharp$2 (p=0.021), respectively. But there was no difference on POD $\sharp$7. Long-term users showed statistically significant difference in pre- and postoperative platelet count, but none in postoperative bleeding and related complications. Conclusion: Continuous use of aspirin and plavix did not increase postoperative bleeding or related complications. Also graft patency and mortality had no statistical differences in continuous users. We think that there is no need to stop aspirin and plavix before OPCAB.

Thermal Performance Evaluation of Solar Hot Water System according to Flow Rate Control (유량제어방식에 따른 태양열 급탕시스템의 열성능 평가)

  • Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.140-145
    • /
    • 2011
  • In this study, the performance and behavior of solar heating system according to the system control scheme, variable flow control (proportional control) and constant flow control (on-off control) was carried out by experiment. The on-off control is used generally for solar thermal system by now. But the proportional control is used for the solar district heating system which is supplied the higher temperature of water than that of desired. The proportional control logic that pump speed is varied in an attempt to maintain a specified outlet temperature of solar heating system was developed and tested for the use widely for the small and medium solar thermal system. The results are as following. First, the proportional controller which is made here could be adopted the characteristics for setting temperature control. Second, the proportional control is better than the on-off control in the side of the performance of thermal stratification in storage tank. Third, the operating energy(electricity consumption by pump) of solar thermal system can be saved more than 60% using the proportional control comparing to the on-off control.