• 제목/요약/키워드: odor unit

Search Result 55, Processing Time 0.029 seconds

An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer (무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석)

  • Oh, I.H.;Lee, J.H.;Lee, K.H.;Lee, J.H.;Lee, D.S.;Eo, S.M.;Lee, M.L.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

A Study on Adsorption Characteristics of Natural Organic Matter and Taste & Odor Using Activated Carbon (활성탄 흡착지에서 응집조건에 따른 자연유기물질과 이·취미(Geosmin, 2-MIB) 파과특성에 관한 연구)

  • Kim, Sung-Jin;Hong, Seong-Ho;Shin, Heung-Sup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.91-99
    • /
    • 2007
  • It is well-known that the presence of NOM (natural organic matter) in water has a negative effect on removing taste and odor compounds by activated carbon adsorption. Therefore, various means such as enhanced coagulation are applied to reduce the NOM. The presence of taste & odor compounds in drinking water even parts per trillion, is enough to generate customer dissatisfaction. Therefore, the aim of this study was to evaluate carbon usage rate (CUR) for conventional coagulation (CC) and enhanced coagulation (EC) in order to improve the efficiency of adsorption of taste and odor compounds. Also, Effect of CC and EC on molecular weight fraction and the early stage breakthrough of 2-MIB and Geosmin are evaluated. When the enhanced coagulation was adapted for pretreatment for activated carbon adsorption the operation period could be prolonged by 3.5~4 times. CUR for CC was about 2 times greater than CUR for EC and this means that EC has more adsorption capacity than CC. To analyze effect of EC and CC on breakthrough of 2-MIB quantitatively, adsorbed NOM mass was calculated based on unit mass of activated carbon. In the early stage breakthrough of 2-MIB, total adsorbed NOM was 23.72mg/g for CC and 34.56mg/g for EC. Therefore, it is shown that the early breakthrough term of 2-MIB and Geosmin was improved due to increased adsorbability. The low-molecular-weight NOM (500~2000Da) compounds were the most competitive, participating in direct competition with 2-MIB for adsorption site.

Odor control of Foodwaste Treatment Facilities (음식물류폐기물처리시설의 악취관리대책에 관한 연구)

  • Kim, Sung-Bum;Oh, Gil-Jong;Kim, Kye-Yeun;Jung, Myung-Sook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.2
    • /
    • pp.71-82
    • /
    • 2006
  • This study was carried out to assess and analyze the overall problems of the facilities in recycling and treating of foodwaste on the basis of the unit operation facilities. It proposes effective alternatives for the high profitable management that can meet the regulation of the facilities. The study is composed of several parts including a collection of academic reports, field studies regarding the facilities operated by local government and the private sector, the analysis on odor samples from compost facilities and processing facilities for animal feed from foodwaste. Twenty facilities were surveyed on the field to find out the existing problems and to compare between facilities. Several facilities didn't meet the governmental regulation on some processes, especially the stages of input, storage, odor control and the qualities of final products under the unit equipment operation. The analysis on the odors from the phases of input, shredding and fermentation of a compost facility and processing facilities for feed, the odors from shredding equipments were higher in concentration than the others. The Major odors from the composting facility contained hydrogen sulfide ($H_2S$), methyl mercaptan ($CH_3{SH}$), Dimethyl sulfide ($(CH_3)_2S$) and Ammonia ($NH_3$) and the major odors from the animal feed facility contained methyl mercaptan ($CH_3{SH}$), Trimethylamine ($(CH_3)_3N$) and Acetaldehyde ($CH_3CHO$).

  • PDF

Characteristics of Bed Media for Reducing Odor from Livestock Facilities (축사 악취저감을 위한 바이오필터 충전재의 악취제거 특성)

  • 한원석;장동일;방승훈;이승주
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.93-102
    • /
    • 2003
  • This study designed and constructed an experimental column far adhesion efficiency test and conducted experiment to investigate the offensive odor adhesion efficiency of filter bed materials. The offensive odor adhesion experiment was conducted using mixture of high physical adhesion efficiency material, and the fixity of deodorization microorganism of selected filter bed material was tested using ammonia exclude microorganism A4-­2 and sulfur oxidation microorganism S5­-5.2 those were cultured at the Agricultural Chemical Department of Chungnam National University, and deodorization efficiency of selected filter bed material mixture was tested. Following are summary of these tests results. 1. Amount of elimination of the offensive odor gas of ammonia and hydrogen sulfide per unit volume was 0.054 and 0.016$\ell/\textrm{cm}^3$ in rice hull, 0.01 and 0.004 $\ell/\textrm{cm}^3$ in rice straw 0.158 and 0.01 $\ell/\textrm{cm}^3$ in coconut, 0.014 and 0.02$\ell/\textrm{cm}^3$ perlite, 0.004 and 0.003$\ell/\textrm{cm}^3$ in high road ball, and 0.112 and 0.015 $\ell/\textrm{cm}^3$ in chaff of pine, respectively. 2. Amount of elimination of offensive odor gas of ammonia and hydrogen sulfide per unit volume was 0.045 and 0.014$\ell/\textrm{cm}^3$ in mixture 1, 0.079 and 0.016$\ell/\textrm{cm}^3$ in mixture 2, 0.123 and 0.017 $\ell/\textrm{cm}^3$ in mixture 3, 0.031 and 0.015$\ell/\textrm{cm}^3$ in mixture 4, 0.055 and 0.016$\ell/\textrm{cm}^3$ in mixture 5, and 0.111 and 0.020$\ell/\textrm{cm}^3$ in mixture 6, respectively. 3. The offensive odor elimination microorganism inoculated to mixture of chaff of pine(70%) and perlite(30%) showed the elimination efficiency of 99.06% and 96.61% against the ammonia and hydrogen sulfide, respectively, during 24 hours period.

  • PDF

Characteristic of Odorous Compounds Emitted from Livestock Waste Treatment Facilities Combined Methane Fermentation and Composting Process (메탄발효와 퇴비화 공정이 연계된 가축분뇨 처리시설에서 발생되는 악취물질 특성 조사)

  • Ko, Han Jong;Kim, Ki Youn;Kim, Hyeon Tae;Ko, Moon Seok;Higuchi, Takasi;Umeda, Mikio
    • Journal of Animal Science and Technology
    • /
    • v.50 no.3
    • /
    • pp.391-400
    • /
    • 2008
  • Odor management is significantly concerned with sustainable livestock production because odor nuisance is a primary cause for complaint to neighbors. This study was conducted to measure the concentration of odorous compounds, odor intensity, and odor offensiveness at unit process in animal waste treatment facility combined composting and methane fermentation process by an instrumental analysis and direct olfactory method. Ammonia, sulfur-containing compounds, and volatile fatty acid were analyzed at each process units and boundary area in summer and winter, respectively. Higher concentration of odorants occurred in the summer than in the winter due to high ambient temperature. The maximum concentration of odorants was detected in composting pile when mixed manure was being turned followed by inlet, curing, outlet, and screen & packing process. Highest concentration of detected odorous compounds was ammonia ranging from 3.4 to 224.7 ppm. Among the sulfur-containing compounds measured, hydrogen sulfide was a maximum level of 2.3 ppm and most of them exceeded reported odor detection thresholds. Acetic acid was the largest proportion of VFA generated, reaching a maximum of 51 to 89%, followed by propionic and butyric acid at 1.9 to 35% and 1.8 to 15%, respectively. Malodor assessment by a human panel appeared a similar tendency in instrumental analysis data. Odor quotient for predicting major odor-causing compounds was calculated by dividing concentrations measured in process units by odor detection thresholds. In the composting process, hydrogen sulfide, ammonia, dimethyl sulfide, and methyl mercaptan were deeply associated with odor-causing compounds, while the major malodor compounds in the inlet process were methyl mercaptan, hydrogen sulfide, and butyric acid.

A study on the burn-in test to accomplish high quality cockpit air of an ultra-sonic aircraft in the early stage of production (생산 초기 초음속 항공기 조종석의 고품질 공기 확보를 위한 burn-in test 연구)

  • Shin, Jae Hyuk;Park, Sung Jae;Seo, Dong Yeon;Jeong, Suheon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.871-876
    • /
    • 2016
  • Abnormal odor similar with burning smell often appears at the cockpit in the beginning of ultra-sonic aircraft without air filter due to the heating of production materials remained at the bleed air duct. Sources of the odor should be removed by burn-in test before test flight in order to prevent pilot confuses order with emergency such as fire of engine. However, the present method cannot prevent abnormal odor completely at the high altitude flight because maximum temperature of flight is higher than it of burn-in-test. This paper suggests burn-in test improved based on the analysis of thermal conditions of high altitude flight. It is verified that the existing burn-in test cannot cover thermal conditions of high altitude flight due to the discontinuous flow control, high change rate of temperature per unit time and difference between limit temperature of condenser and turbine. In order to overcome the limitations of current methods, the new burn-in test with continuous flow control are suggested. The continuous flow control are achieved by ram air inlet control. The effect of suggested method are verified by ground tests and flight tests. The results show the bleed air temperature can cover the temperature of high altitude flight and prevent abnormal odor at the flight test.

Public Environment Index Development (환경상태의 평가를 위한 주민환경지표의 개발)

  • Kim, M.J.;Choi, D.I.;Chang, C.K.;Lee, J.W.
    • Journal of Environmental Impact Assessment
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 1993
  • As the environmental concerns have shifted gradually from the environmental pollutions to the Quality of Life (QOL) enhancement, it has become increasingly important to implement comprehensive assessment of environmental quality for public information as well as decision making. This study focuses on development of PEI(Public Environment Index) which has purposes to improve regional environment and analyzes the status of environment by public as one kind of environmental indices. Factors of PEI calculations are air, water, noise, green space and landscape. Factors are composed of 20 items including soiling and odor. Major contents are calculation of PEI, correlation analysis of factors and items of PEI, regression analysis of PEI and objective environmental indicators prepared as a dong unit, and PEI presentation using GIS. Also, for applying PEI effectively, environmental information as a dong unit is to be collected and managed periodically.

  • PDF

Use of 1,064-nm Q-switched Neodymium:Yttrium-aluminum-garnet Laser Therapy Assisted with Diamond Particle Suspension and Gold Microparticle Application for Acne Vulgaris and Enlarged Facial Pores

  • Park, Hee Ung;Cho, Hangrae;Lee, Sang Ju;Cho, Han Kyoung
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.242-245
    • /
    • 2021
  • Acne vulgaris is a common inflammatory skin disease of the pilose-baceous unit. It appears as lesions consisting of comedones, papules, pustules, and nodules of varying shapes and severity. In general, the first-line treatment for acne vulgaris includes topical and oral medication. Recently, various physical modalities have also been investigated. The use of laser therapy is steadily increasing because of its fewer side effects, short procedure time, and rapid results. In particular, laser therapy assisted with carbon suspension application is effective for acne vulgaris but may sometimes result in discomfort due to odor and dust formation during the procedure. Herein, we report that acne vulgaris and enlarged facial pores can be safely and effectively treated with laser therapy assisted with diamond particle suspension and gold microparticle application, which can address the discomfort caused by the carbon suspension application.

Emission Characteristics of VOC due to Major Industrial Activities in the Ban Wall Industrial Complex (안산시 반월공단을 중심으로 한 주요 배출시설의 업종 및 배출시설별 VOC의 배출특성)

  • Im, M.S.;Kim, K.H.;Choi, Y.J.;Jeon, E.C.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.325-336
    • /
    • 2006
  • The presence of volatile organic compounds (VOC), produced and released from both anthropogenic and natural sources, can accelerate the degradation of air quality in the surrounding area. In this study, we investigated the emission concentrations of VOC based on a total of 115 sample analysis made from 47 companies (representing 17 types of industry) at the Ban Wall industrial complex (Jun. 2004 to Jan. 2005). Through a statistical analysis of these measurement data, we inspected the emission characteristics of VOC in relation with industrial type and processing unit. When these data were compared each other, toluene was found to record the highest value of 423 ppb followed by ethylbenzene (68.3 ppb), m, p-xylene (43.6 ppb), o-xylene (27.2 ppb), styrene (23.9 ppb), and benzene (16.4 pub). In addition, by converting these VOC concentration data into malodor intensity, we attempted to account for their distribution patterns in terms of relative contribution to the malodor formation. The results of odor intensity conversion generally indicated that the odor intensities of individual VOC do not exceed the degree of 1. When our VOC results were compared against other odorous compounds measured concurrently, the results were highly contrasting each other. Despite relative insignificance as odorous compounds, these VOCs are generally found ubiquitously and in abundant quantities in this strong source area.