• Title/Summary/Keyword: odor control

Search Result 423, Processing Time 0.021 seconds

Evaluation of Malodor Release and Control Devices in Charcoal Manufacturing Facility (숯 제조시설의 악취물질 배출특성과 관리실태 조사 연구)

  • Jeong, Ju-Young;Seo, Byeong-Ryang;Kim, Jae-Hyuck;Chin, Sung-Min;Jurng, Jong-Soo
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.883-890
    • /
    • 2012
  • Emission characteristics of gaseous odor compounds emitted from the charcoal manufacturing process were investigated, and evaluated the odor removal efficiency of odor control devices. It was found that the measured odor dilution ratio of emission gases ranged from 10,000 to 44,814, which exceed largely the emission standard in the stack. Methylmercaptan, trimethylamine, hydrogen sulfide, acetaldehyde were turned out as major odor compounds of the charcoal manufacturing process. It was revealed that the odor removal ratio of odor control devices were very low due to the its improper maintenance and wrong design.

A Comparative Study for Odor Control Regulations (악취관리제도의 국가간 비교연구)

  • 양성봉;김석만
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.79-87
    • /
    • 2000
  • This study analyzed the regulations concerning odor management or control in Korea, Japan, and developed countries such as USA and Germany. The Korean restriction standards and measurement methods for offensive odor substances are very similar to the Japanese standards and methods promulgated in 1976. Japan promulgated the odor control act and the specific measurement methods of the offensive odor substances in 1973. In Japan, currently, the local governments can establish their own odor restriction areas and proclaim their own standards suitable for their situations. Also, Japan has more strict regulations and more offensive odor substances to be monitored than Korea. The restriction standards of odor in German is quite similar to the permissible limits and standards of air pollutants at emission sources in Korea. Many states in USA are adopting their own restriction standards and measurement methods, e.q., the ambient air pollution standards, organic functionstest methods by dilation, and establishment and addition of air pollution control equipment at emission sources. Finally, this study analyzed the problems of the regulations, standards, and measurement methods concerning the Korean offensive odor management. Since the direct organic fuctions measurement(DOFMM) method is depending upon the personal sensitives of odor substances, the measurement odor value can be equivocal. That is, the odor measurement value by an examines can differ from that by the other examines. Also, there can be conflicts with the measured odor values depending upon the applied measurement methods, e.q., the DOFMM, the dilation method, and the instrumental analysis method.

  • PDF

A Review of the Odor Control From Inside of Swine Production Facilities (양돈시설 내부의 악취조졸에 관한 기술 및 연구동향)

  • 김두환;김인배
    • Journal of Animal Environmental Science
    • /
    • v.5 no.3
    • /
    • pp.203-216
    • /
    • 1999
  • Recent public concern about air pollution caused by swine production facilities has forced to develop the methods to reduce and control the swine odors. Swine odors were affected the life of pig farm neighborhoods, swine productivity, pig health, diseases, and human right, safety, sanity as negatively. The first approaches of control of swine odors are the change or improve of the classical management systems, which are manure treatment method, manure storage facility, phase feeding, sex-divided feeding, feeder type, liquid-slurry feeding, environment control of swine building and dust control of indoor swine facility. The methods to control odor emission from manure have to include the diet modification as nutritional basis. In recent, research emphasis has focused on manipulating the swine diet to increase the nutrient utilization of the diet to reduce excretion products and reduction of odors. There are lots of feed additives and pit additives introduced as practical basis for reducing odor emissions. The ozone treatment method is candidate as the good system for reducing swine odor. But this system is still too expensive to practice in present.

Current Status and Perspectives of Livestock Environment Improving Agents for the Characteristics and Control of Swine Manure Odor (양돈 분뇨의 악취특성 및 문제 해결을 위한 환경개선제 사용 현황 및 전망)

  • Lee, Eun-Young;Lim, Jung-Soo
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.3
    • /
    • pp.244-254
    • /
    • 2010
  • The trend toward intensification of livestock raising, confinement in barn has increased in recent days. The move toward concentrated animal feeding operations reduces per unit costs and permits farmers to better earnings in spite of fluctuation in hog prices. However, this also results in outbreaks of a lot of animal wastes and odorous compounds. Emissions of these malodorous compounds produced from concentrated animal feeding operations have become a concern for both public and regulatory agencies and are causing the complaints of residents in rural area. For competitive sustainable swine production industry, odor management plans systematically identify potential odor sources, determine control strategies to reduce these odors, and establish criteria for implementing these strategies. Since, the malodor originates from microbial activities involving a variety of microbes, understanding the characteristics of the microflora present in swine manure is essential for developing effective odor control techniques. This paper reviews the available information in the literature related to the types of bacteria in swine manure, the potential odorous compounds associated with different bacterial genera, and the corresponding techniques used to control odor based on microbiological principles.

Health Effects from Odor Pollution in Sihwa Industrial Complex (경기도 시화공단 지역주민의 악취오염과 관련된 건강영향 평가)

  • Cho, Soo-Hun;Kim, Sun-Mean;Kim, Young-Su;Kim, Jae-Yong;Choi, Seong-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.4
    • /
    • pp.473-481
    • /
    • 1999
  • Objectives: In recent days, the problem of odor pollution in community near Sihwa Industrial complex, Kynuggi Province is becoming of significant public concern. We have investigated the health effects of the Sihwa residents from odor pollution comparing with other less polluted areas. Methods: The Ansan and Kuri Cities were selected as control areas. The parents of the elementary and middle school students in these three areas were surveyed with structured questionnaire twice, Nov 1997 and Jure 1998 each. As a exposure index, the ambient air concentrations of five major air pollutants(particulates, $O_3,\;SO_2,\;NO_2$, CO) and subjective odor perception were used. We have focused health outcomes such as the prevalence of nonspecific irritant symptoms, respiratory disease among family members and the score of qualify of life(QOL). Results: Although the mean concentrations of major air pollutants except particulates were similar or lower in Sihwa than other areas, the odor perception rate and the monthly odor perception days were significantly higher. It suggested that odor producing chemical compounds are the major source of environmental pollution problem. There were higher prevalence rates of nonspecific irritant symptoms and respiratory disease among family members in Sihwa than other control areas. The QOL score was also lower in Sihwa. The odor perception proved to be a most important factor in reporting adverse health effects and lowering the QOL score. Conclusion: The residents living near Sihwa industrial complex were suffering from more adverse health symptoms and poorer QOL status than control areas. And it may be due to environmental odor pollution from industrial complex. Therefore, further research will be needed for monitoring of the responsible chemicals emitted from industries.

  • PDF

Research on Odor Analysis Technology to Secure the Reliability of Air Quality Improvement in Air Conditioners (에어컨디셔너 공기질 개선의 신뢰도 확보를 위한 냄새 분석 기술 연구)

  • Kang, Seok-Hyun;Huh, Pil-Ho;Ahn, Young-Chull
    • Journal of Environmental Science International
    • /
    • v.30 no.1
    • /
    • pp.45-55
    • /
    • 2021
  • In this study, the odor of the parts and the odor of the surrounding environment were classified and verified. In order to increase the reliability of odor quantitative/qualitative analysis, the selection criteria for 5 sensory evaluators were established, and the n-Butanol control solution for each odor intensity was periodically trained to recognize the odor intensity before sensory evaluation. In addition, although various odor thresholds have been used through several studies, verification of whether the odor intensity value obtained through GC/MSD analysis is similar to the degree to which a person directly smells and feels it. It is important to select the odor threshold that has the best correlation with the odor intensity calculated by the person smelling the odor. Finally, sampling and measuring flowing airflow and temporary odors such as odor component analysis was experimentally difficult due to limited collection space and differences in concentration of generated components. In this study, a quantitative analysis was made possible by using the low temperature concentration (cooling) trap method. Through this, it was confirmed that the correlation with the actual odor intensity was not caused by the product itself, but by the environmental factor discharged from the product after creating the odor environment.

The Relationship Between Odor Unit and Odorous Compounds in Control Areas Using Multiple Regression Analysis (다중회귀분석을 이용한 악취 관리지역에서의 복합취기강도와 개별악취물질들의 관계에 대한 연구)

  • Kim, Jong-Bo;Jeong, Sang-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.191-200
    • /
    • 2009
  • We investigated a trait of odor and the relationship between odor unit and odorous compounds using multiple regression analysis based on data compiled from Sihwa (SIC), Banwol (BIC), Banwol plating (BPIC) and Poseung industrial complex (PIC). These areas are odor control areas in Gyeonggi province. It was revealed that $NH_3$ and styrene concentrations in SIC and BPIC were relatively higher and $H_2S$ concentration especially in mc was more than five times higher than other areas. As a result of regression analysis using SAS, intensity of odor unit was highly related to concentrations of $H_2S$, TMA, styrene and n-valeraldehyde in SIC, $H_2S$, acetaldehyde, and butyraldehyde in BPIC and $NH_3$ in BIC.

A technology of realistic multi-media display and odor recognition using olfactory sensors (후각 센서를 이용한 냄새 인식 및 실감형 멀티미디어 표현 기술)

  • Lee, Hyeon Gu;Rho, Yong Wan
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.4
    • /
    • pp.33-43
    • /
    • 2010
  • In this paper, we propose a floral scent recognition using odor sensors and a odor display using odor distribution system. Proposed odor recognition has method of correlation coefficient between sensors that select optimal sensors in floral scent recognition system of selective multi-sensors. Proposed floral scent recognition system consists of four module such as floral scent acquisition module, optimal sensor decision module, entropy-based floral scent detection module, and floral scent recognition module. Odor distribution system consists of generation module of distribution information, control module of distribution, output module of distribution. We applied to floral scent recognition for performance evaluation of proposed sensors decision method. As a result, application of proposed method with floral scent recognition obtained recognition rate of 95.67% case of using 16 sensors while applied floral scent recognition system of proposed sensor decision method confirmed recognition rate of 96% using only 8 sensors. Also, we applied to odor display of proposed method and obtained 3.18 thorough MOS experimentation.

Examination about evaluation method of odor active compounds in evaporator by using condensed water (응축수를 이용한 냉각기의 냄새원인물질 평가방법 검토)

  • Kim, Sun-Hwa;Kim, Kyung-Hwan;Jung, Young-Rim;Kim, Man-Goo;Kim, Jae-Ho;Park, Ha-Young;Ji, Yong-Jun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.361-369
    • /
    • 2007
  • Uncomfortable odor emitted from air conditioning system is the main cause of indoor air quality deterioration. To solve evaporator odor problems, odor active compounds, have to be identified then the quality of the product can be improved its quality. Because evaporator odor in exhaust gas has low odor intensity and discontinuity, it is very difficult to collect and analyze sample. In this study through the identification of odor compounds in condensed water, the evaluation of the eraporator was tested. Odor compounds were extracted from water by headspace-solid-phase microextraction (HS-SPME) method. The single odor was separated by GC/FID/Olfactometry (GC/FID/O) and odor active compounds were identified by GC/AED and GC/MS. Compared to air sample, result of sensory evaluation and the single odor compound appeared similarly. It was identified that odor active compounds have functional group containing oxygen such as alcohols and acids. Evaluation method of odor active compounds using condensed water in evaporator appeared effective on the side of simplicity of collection, low expanse and rapid analysis.

Emission Characteristics of Odor Compounds from Pneumatic Waste Collection Plants (생활폐기물 자동집하시설의 악취물질 배출특성)

  • Yoon, Yongkyeong;Kim, Daekeun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.541-548
    • /
    • 2012
  • The objective of this study was to investigate emission characteristics of odorous compounds from the pneumatic waste collection plants (namely, A and B sites). The air samples were collected from each site, at a carrier gas inside the plant and an exhaust gas, to analyze complex odor and 22 odorous compounds. Ammonia, sulfur compounds, and acetaldehyde were the critical odorous components generated in the plants studied. Characteristics of odor at exhaust outlet varied according to the type of odor control engineering. In the analysis of the odor contribution degree of odor components based on odor threshold, site A shows that the odor contribution of dimethyl sulfide was found to be 26%, acetaldehyde 18%, and methyl mercaptan 14%. For site B, methyl mercaptan was 56% and both hydrogen sulfide and dimethyl sulfide were 15%.