• 제목/요약/키워드: odor concentration

검색결과 386건 처리시간 0.027초

도시내 배수설비 슬러지가 악취에 미치는 영향 연구 (Effect of municipal sludge from drainage facility on foul smell)

  • 유대현;박지훈;이용훈;이장훈;강선홍
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

대구시 산업단지 환경기초시설의 악취발생 특성 (Emission Characteristics of Odor Compounds from Fundamental Environmental Facilities in an Industrial Complex Area in Daegu City)

  • 이찬형;전현숙;신명철;김은덕;장윤재;권병윤;송희봉
    • 한국환경보건학회지
    • /
    • 제42권4호
    • /
    • pp.246-254
    • /
    • 2016
  • Objectives: This study evaluated the odor emission characteristics from fundamental environmental facilities at an industrial complex area in Daegu City. Methods: The odor samples were collected from May 2015 to January 2016 and were analyzed for specified offensive odor substances. The odor quotient and the odor contribution was calculated. Results: Ammonia was detected in all samples monitoring specified odor compounds, followed by hydrogen sulfide and acetaldehyde. According to contribution analysis, hydrogen sulfide shows the highest contribution in all facilities. At wastewater treatment plants A and B and sewage treatment plant F, it was followed by acetaldehyde. At wastewater treatment plant C, it was followed by imethyl sulfide. Conclusion: The major component of odor can be determined by evaluating the degree of contribution to the odor intensity rather than the concentration of the individual odor components. To increase the effectiveness of odor reduction, policies focused on materials with a high odor contribution are needed rather than focusing on high-concentration odor compounds.

대구시 산업단지 염색폐수처리장의 악취발생 특성 (Emission Characteristics of Odor Compounds from a Dyeing Wastewater Treatment Plant in an Industrial Complex Area in Daegu City)

  • 이찬형;전현숙;권병윤;김은덕;장윤재;이명숙;금종록;송희봉
    • 한국환경보건학회지
    • /
    • 제43권4호
    • /
    • pp.314-323
    • /
    • 2017
  • Objectives: This study evaluated the odor emission characteristics from a wastewater treatment plant in an industrial complex area in Daegu City. Methods: Odor samples were collected from March 2016 to December 2016 and were analyzed for specified offensive odor substances. The odor quotient and the odor contribution was calculated. Results: Ammonia, hydrogen sulfide, acetaldehyde, and toluene were detected in all samples for monitoring specified odor compounds. The result of contribution analysis is that hydrogen sulfide had the highest contribution in all processes, followed by acetaldehyde. Conclusion: The major components of odor can be determined by evaluating the degree of contribution to the odor intensity and the concentration of the individual odor component. To increase the effectiveness of odor reduction, rather than addressing high-concentration odor compounds, policies focused on materials with a high odor contribution are necessary.

대구시 산업단지 인근 하수처리장의 악취발생 특성 (Emission Characteristics of Odor Compounds from a Sewage Treatment Plant Near an Industrial Complex Area in Daegu City)

  • 이명숙;강동훈;금종록;권병윤;조항욱;이찬형;김은덕;임호진;송희봉
    • 한국환경보건학회지
    • /
    • 제44권2호
    • /
    • pp.178-187
    • /
    • 2018
  • Objectives: This study evaluated the odor emission characteristics from a sewage treatment plant near an industrial complex area in Daegu City. Methods: Odor samples were collected from March 2017 to December 2017 and analyzed for specified offensive odor substances. The odor quotient and the odor contribution were calculated. Results: Ammonia, methyl mercaptane, hydrogen sulfide, dimethyl sulfide, acetaldehyde, propionylaldehyde, toluene, xylene, and methylethylketone were detected in all samples for monitoring the specified odor compounds. The result of contribution analysis is that hydrogen sulfide made the highest contribution in all processes, followed by acetaldehyde. Conclusion: The major components of odor can be determined by evaluating their degree of contribution to the odor intensity and the concentration of the individual odor component. To increase the effectiveness of odor reduction, rather than addressing high-concentration odor compounds, policies focused on materials with a high odor contribution are necessary.

An Analysis of Odors in Traditional Market in Wonju, Gangwon-do

  • KIM, Su-Hye;LEE, Woo-Sik;JEONG, Tae-Hwan;JUNG, Min-Jae
    • 웰빙융합연구
    • /
    • 제5권3호
    • /
    • pp.19-25
    • /
    • 2022
  • Purpose: As interest in odor increases, odor complaints are also rapidly increasing. Traditional markets are not included in malodor control areas and are not easy to manage, so measure the odor substances generated in traditional markets and analyze the cause of high concentration points. Research design, data and methodology: The average value was presented by continuously measuring the combined odor, TVOC, hydrogen sulfide, and ammonia for 5 minutes at 100m intervals in Joong-ang traditional market, Jayu traditional market, Doraemi traditional market, and Sundae Alley in Wonju, Gangwon-do. In each market, up to the third highest concentration point for each measurement item was marked and analyzed. Results: The Joong-ang traditional market, Doraemi traditional market, and Sundae Alley had high readings at the intersection. The Jayu traditional market had high measurements around restaurants and clothing stores. In addition, the concentration of complex malodors was also high at the points where the hydrogen sulfide concentration was measured. Conclusions: Odor generated in traditional markets is an important indicator for merchants and consumers. Therefore, in future studies, analysis that can supplement the limitations of measurement data and seasonal effects is needed.

지렁이 분변토와 주정슬러지 혼합 배양액을 이용한 Biofilter에서의 고농도 악취제거 (Removal of High Odor Concentration with Biofilter using Mixture of Earthworm Cast and Distillery Sludge)

  • 박종웅;장석조
    • 한국환경보건학회지
    • /
    • 제40권2호
    • /
    • pp.127-136
    • /
    • 2014
  • Objectives: This study was conducted to investigate the removal of high odor concentration from swine wastewater treatment facility by full scale biofilter using liquid with deodorant mixed with earthworm cast and distillery sludge. Methods: The supply of the culture liquid to the microorganism on the media in the biofilter increases the activity and growth of biomass. The experimental equipment was biofilter tower with treatment capacity of 90 m 3/min. The experimental conditions included gas flow of $60m^3/min$, retention time of 20 sec, and gas/liquid ratio of 67. Results: With changing season from winter to summer, the inlet odor concentration of ammonia increased from 2.5 ppm to 29 ppm, and of hydrogen sulfide from 21 ppm to 91 ppm, respectively. The odor treatment system with biofilter using the culture liquid was stable when the high loading rate increased and showed excellent removal grade with an average of 96.7% for ammonia, and an average of 93.7% for hydrogen sulfide. The pH and SCOD in the recirculating culture liquid near the bottom of the biofilter tower decreased with operation time, but its influence on the odor removal rate was negligible, because the organic matter (SCOD) was replaced by some culture liquid supplied 2-4 times per day. Conclusions: The biofilter using culture liquid could successfully remove high odor concentration which was generated from swine wastewater treatment facility.

축산시설의 축종별 악취물질 농도 특성과 악취도 평가 (Assessment of Odor Characterization and Odor Unit from Livestock Facilities by animals)

  • 장영기;정봉진;김정;송기봉;김호정;유용희
    • 환경영향평가
    • /
    • 제19권1호
    • /
    • pp.29-38
    • /
    • 2010
  • At recent the number of livestock is increased and the size of farm has changed to large facilities in Korea. So the livestock facilities have become one of major sources of odor emission. The purpose of this study is to analyze the concentration and assessment of odor unit from livestock facilities for cow, dairy, swine and poultry. The eleven odor pollutants such as $H_2S$, ($CH_3$)SH, $(CH_3)_2S$, $(CH_3)_2S_2$, $CH_3N$, $NH_3$, $(CH_3)_2N$, $(CH_3)_3N$, butyric acid, valeric acid and isovaleric acid, measured for assessment of the odor concentrations from livestock facility. As the results, it is found that the major matters of odor from livestock facilities were $NH_3$ and $H_2S$. The highest concentration of $NH_3$ is measured as 15 ppm at henhouse and $H_2S$ is measured as 858 ppb at penpig facilities. In the comparison of the average odor unit from livestocks, it is found that the highest odor unit was from swine and the lowest odor unit was from cow facility. So odor unit from swine facilities was 12 to 30 times higher than the odor unit from cow facilities.

호안블록용 박테리아 기반 악취저감 키트의 악취제거 성능평가 (Evaluation on Odor Removal Performance of Bacteria-Based Odor Reduction Kit for Revetment Blocks)

  • 양근혁;문주현;정기태;윤현섭;심재일
    • 한국건설순환자원학회논문집
    • /
    • 제12권2호
    • /
    • pp.229-238
    • /
    • 2024
  • 이 연구에서는 박테리아 기반 악취저감 키트의 악취제거 성능을 평가하였다. 박테리아는 악취오염원인 암모니아(NH3), 황화수소(H2S), 총질소(T-P) 및 총인(T-N)을 제거할 수 있는 Rhodobacter capsulatus, Paracoccus limosus 및 Brevibacterium hankyongi를 사용하였다. 사용된 소재들은 박테리아와 다공성골재(팽창질석, 제올라이트 비드, 활성탄)이며, 제거 메커니즘에 따라 소재들의 융합을 달리하였다. 물리적 흡착 메커니즘을 갖는 소재들(제올라이트 비드 및 활성탄)은 악취오염원(NH3, H2S, T-P 및 T-N)의 농도 저감율이 점차 둔화되어 48시간 이후부터 더 이상의 악취오염원의 농도의 저감 효과가 없었다. 생물학적 흡착 메커니즘으로 악취를 제거하는 박테리아가 고정화된 팽창질석은 지속적인 농도 저감으로 108시간 이후에 악취오염원의 농도가 0 ppm에 도달하였다. 결과적으로 실제 하천수에서 물리적 흡착 메커니즘을 갖는 소재들의 악취제거 성능은 환경부에서 제시하고 있는 악취 배출허용 기준을 만족하지 못한 반면, 박테리아가 고정화된 팽창질석은 악취 배출허용 기준을 만족하였으며, 수질도 1등급으로 평가되었다.

화학공장의 악취배출량으로부터 간이 악취 영향도 예측 사례 (Simple Prediction of Odor Affection by Odor Emission Rate from a Chemical Plant)

  • 유미선;양성봉;이오근
    • 한국환경과학회지
    • /
    • 제11권4호
    • /
    • pp.383-389
    • /
    • 2002
  • Odor sources of a chemical plant in Ulsan were surveyed and temperatures, humidities and flow rates of each exhaust gas were measured. The air samples collected from each source were transferred to the laboratory for sensory test and their odor concentrations were investigated. The odor emission rate of each source was estimated from the recorded results and assigned the sources expected to be needed for the odor prevention policy using the simple prediction equation of the affection by malodor to the nearest residential area. From the total odor emission rate of the examined plant and the relation table for expectable affection area it was concluded that total odor emission of this plant might be decreased for the prevention of residential complaint.