• 제목/요약/키워드: occurred defect data.

검색결과 43건 처리시간 0.022초

공동주택 하자실적자료 분석을 통한 철근콘크리트 공사의 하자담보책임기간 비교연구 (Comparative Review on Term of Warranty Liability of Reinforced Concrete Work through Occurred Defect Data Analysis in Apartment Building)

  • 서덕석;박준모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.266-267
    • /
    • 2017
  • As apartment buildings defect lawsuits become socioeconomic problems, an objective basis system for the term of warranty liability of reinforced concrete constructions is urgent. This study was carried out as a basic study for developing a basis system for the term of warranty liability. To do this, defect data actual collected in apartment complexes were collected and analyzed. As the result of checking the cumulative rate of defect occurrence in reinforced concrete construction by year, the point of time of reaching the 90% level was the 5th years, which was similar with the provision of the Apartment Building Management Act. However, the current Supreme Court precedent has decided that the term of warranty liability for the main structural parts in reinforced concrete construction shall be 10 years and the dispute is expected to continue in the future in the defect lawsuit.

  • PDF

공동주택 하자감정을 위한 하자조사단계의 현장조사 업무 모델링 (Field Investigation Work Modeling on Defect Inspecting Step of Defect Consulting in Apartment Building of Korea)

  • 박준모;서덕석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2015
  • A defect dispute surrounding an apartment building is in constant trouble, a defect consulting is necessary that objective and impartial for solving a defect. The defect dispute about a defect lawsuit is conducted in the order that filling of lawsuit, consulting order, defect inspecting, estimating a repairing cost, writing a consulting report, submitting a consulting report, and decision by court. Of these, a step of defect inspecting is extensively investigated an occurred defect that each defect index and type from each part and place. At this time, it is collected of many data and created many information. For this, it need to organize and manage. The study is a modeling of field investigation work process that second phase of defect inspecting step. A literature study is defined a work until level 2. This study is defined the work until level 3 to 4. In addition, the modeling can do for using a job name, a place to job, a job to do, and a person concerned about defect consulting case. The modeling is expected a contribution of improving a defect consulting process and systematizing a judgment standard.

  • PDF

아파트 단지 내 블록포장의 종류와 공간유형에 따른 하자분석 (Defect Analysis According to the Types and Spatial Type of Block Pavement in Apartment Complex)

  • 박근혜;정성관;장철규
    • 한국환경복원기술학회지
    • /
    • 제23권3호
    • /
    • pp.91-104
    • /
    • 2020
  • This study was conducted to analyze the characteristics of defects according to the type of block and spatial type by quantitatively examining defects occurring in block pavement in apartment complex. According to the research results, depending on the type of block, defects have occurred 1,394.3ea/100㎡ in interlocking paver blocks, 464.8ea/100㎡ in clay brick paver blocks, and 235.1ea/100㎡ in shot blasted paver blocks. By space type, the defects were occurred 1,576.0ea/100㎡ on the access road paved by interlocking paver blocks and the defects were found 1,139.6ea/100㎡ in interlocking paver blocks, 235.1ea/100㎡ in shot blasted paver blocks, and 797.1ea/100㎡ in clay brick paver blocks, on the sidewalk. Also the defects are occurred 455.6ea/100㎡ on the resting space and 403.2ea/100㎡ on the gym space paved by clay brick paver blocks. Through the size analysis of the defects in the block paver, in the case 'peeling', the largest volume of 2,539.0㎣ on the sidewalk paved with shot blasted paver blocks, and 'Subsidence' occurred at the widest area of 2,096.0㎠ on the sidewalk where interlocking paver block was constructed. The difference in defect occurrence according to the type of block is considered to be influenced by the block production process, and the space type is considered to be caused the difference in the occurrence of defects according to the cause of construction and the usage pattern of residents. This study conducted a survey on defects in block and analyzed the defect characteristic according to paver material and space type. Base on this, it is judged that it can be used as an efficient basic data for material replacement, improvement, paver planning and construction in the future.

한옥 유지관리매뉴얼 개발을 위한 결함 유형 현장 조사 (A Field Investigation of Defect Type for Development of Maintenance Manual of Han-ok)

  • 이종신;최광식;양정무
    • 한국가구학회지
    • /
    • 제24권3호
    • /
    • pp.302-308
    • /
    • 2013
  • To collection of field data for development of maintenance manual of Han-ok, we investigated defects which occurred in members of Han-ok by field investigation. The noticeable defects were wood cracks, gaps that developed between wood pillar and wall or wood window frame and tenon joints. The most common biological defect was blue stain which was created in log. The mold generation was observed on exterior wood and wall which get wet by precipitation. The gaps between members of Han-ok pointed out as defect that is urgently improved by residents of Han-ok. The reason is mainly due to poor of insulation in winter by bad confidentiality. The maintenance work of defect such as gap was conducted personally. As a result, the repair parts were ugly for unfamiliar repair work.

  • PDF

냉각재 공급자관 위상배열 검사 적용에 따른 결함 분석 (Analysis of Defect in CANDU Feeder Pipe using Phased Array Ultrasonic Inspection System)

  • 이상훈;진석홍;김인철
    • 한국압력기기공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.78-82
    • /
    • 2010
  • The feeder pipe of Main Primary Heat Transfer System in Wolsong Nuclear Power Plant was inspected by the Ultrasonic Phase Array technique in 2010. It is the first time to apply this method to the construction at Nuclear Power Plant in Korea. The time required for UT technique is less than RT method. The UT method doesn't need to evacuate personnel who works nearby inspecting area and doesn't need to wait developing of film. For these reasons, the UT method is the fastest method among the volumetric inspections. As a result of the examination, it became clear that main defect of the feeder pipe is the Lack of fusion in the welded area. Moreover, the rate of defect was reduced gradually as improvement of welder's skill. If welding machine has problem, the defect has tended to same pattern(occurred same position in the welding area) but these defects were founded without specific rules. For these reasons, the creation of defect is dependent on the skill of worker not on the automatic welding machine. This evaluation of defect signal and collecting data would be useful to further examination in ISI.

  • PDF

A Decision Tree Approach for Identifying Defective Products in the Manufacturing Process

  • Choi, Sungsu;Battulga, Lkhagvadorj;Nasridinov, Aziz;Yoo, Kwan-Hee
    • International Journal of Contents
    • /
    • 제13권2호
    • /
    • pp.57-65
    • /
    • 2017
  • Recently, due to the significance of Industry 4.0, the manufacturing industry is developing globally. Conventionally, the manufacturing industry generates a large volume of data that is often related to process, line and products. In this paper, we analyzed causes of defective products in the manufacturing process using the decision tree technique, that is a well-known technique used in data mining. We used data collected from the domestic manufacturing industry that includes Manufacturing Execution System (MES), Point of Production (POP), equipment data accumulated directly in equipment, in-process/external air-conditioning sensors and static electricity. We propose to implement a model using C4.5 decision tree algorithm. Specifically, the proposed decision tree model is modeled based on components of a specific part. We propose to identify the state of products, where the defect occurred and compare it with the generated decision tree model to determine the cause of the defect.

IoT 제품의 품질 개선을 위한 결함관리 설계에 관한 연구 (Study for Design of Defect Management to Improve the Quality of IoT Products)

  • 김재경;최영숙;조경록;이은서
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제11권6호
    • /
    • pp.229-236
    • /
    • 2022
  • 사물인터넷을 기반으로 실시간으로 소화기 주변의 상태와 화재 발생 여부, 소화기의 상태를 확인할 수 있는 웹 시스템과 화재 알림을 받을 수 있는 애플리케이션을 구현한다. 해당 시스템의 목표를 명확하게 정하고 구조를 상세히 정의함으로써 개발 도중 일어나는 오류를 최소화한다. 또한, 스마트소화기에 대한 요구분석과 설계, 구현 단계에서 제품 결함을 찾아내고 그 원인을 분석하여 결함을 줄이는 방법을 제안한다. 제안하는 연구를 통해 IoT 기반의 스마트 소화기에 대해 결함관리 신뢰성을 확보할 수 있다.

아파트 리모델링 공사의 하자발생 시기 및 원인에 관한 연구 (Questionnaire Survey on the Occurrence Time and Cause of Defect in Remodeled Apartment)

  • 박선규
    • 한국콘텐츠학회논문지
    • /
    • 제15권12호
    • /
    • pp.596-603
    • /
    • 2015
  • 1970년대 이후부터 이룩한 경제성장은 심각한 도시화 현상을 초래하였으며, 인구 증가와 함께 심각한 주택부족 현상을 가져왔다. 이에 정부를 비롯한 민간 건설업체는 도시지역의 주택수요를 충족시키기 위해 아파트를 비롯한 공동주택을 꾸준히 건설하게 되었다. 아파트는 주로 철근콘크리트로 건축되며, 처음에 가졌던 성능을 유지하기 어렵고, 지속적인 노후화 및 주거생활 문화의 변화에 따라 리모델링을 실시하게 된다. 리모델링은 환경문제 및 자원절약이라는 측면에서 재건축 보다 효율적인 방법이기 때문에 건축분야의 커다란 콘텐츠로 자리매김하게 되었다. 그러나, 아파트의 리모델링 공사는 필요에 따라 소규모로 이루어지고 있어 리모델링 공사에 대한 정보가 부족한 실정이며, 특히, 리모델링 공사 후에 발생하는 하자에 대한 정보는 더욱 부족한 실정이다. 따라서 본 논문에서는 아파트 리모델링 공사 후에 발생하는 하자의 발생시기와 원인에 대하여 설문조사를 실시한 후 결과를 분석함으로써, 아파트 리모델링 공사에 대한 정보를 제공함과 동시에 향후 아파트를 비롯한 공동주택의 효과적인 유지관리를 위한 기초적인 데이터를 제시하고자 한다.

원전 배관 손상압력 평가를 위한 파열시험 및 유한요소해석 (Burst Test and Finite Element Analysis for Failure Pressure Evaluation of Nuclear Power Plant Pipes)

  • 윤민수;김성환;김태순
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.144-149
    • /
    • 2015
  • This study aims to quantitatively evaluate failure pressure of wall-thinned elbow under combined load along with internal pressure, by conducting real-scale burst test and finite element analysis together. For quantitative evaluation, failure pressure data was extracted from the real-scale burst test first, and then finite element analysis was carried out to compare with the test result. For the test, the wall-thinning defect of the extrados or intrados inside the center of 90-degree elbow was considered and the loading modes to open or close the specimen maintaining a certain load or displacement were applied. Internal pressure was applied until failure occurred. As a result, when the bending load was applied under the load control condition, the intrados of the defect was more affected by failure pressure than the extrados, and the opening mode was more vulnerable to failure pressure than the closing mode. When the bending load was applied under the displacement control, it was hardly affected by failure pressure though it was slightly different from the defect position. The result of the finite element analysis showed a similar aspect with the test. Moreover, when major factors such as material properties and pipeline thickness were calibrated to accurate values, the analytical results was more similar to the test results.

3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구 (Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition)

  • 최충석
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).