• 제목/요약/키워드: occlusal scan

검색결과 97건 처리시간 0.028초

Computerized occlusal analysis: correlation with occlusal indexes to assess the outcome of orthodontic treatment or the severity of malocculusion

  • Lee, Sang-Min;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • 제46권1호
    • /
    • pp.27-35
    • /
    • 2016
  • Objective: The aims of our study were to verify the validity of the T-Scan III system (Tekscan) as an objective occlusal evaluation tool, and to assess the differences between two occlusal indexes - the peer assessment rating (PAR) index and the American Board of Orthodontics objective grading system (OGS) - by comparing the scores derived from the T-Scan III system with the two occlusal indexes and analyzing the correlations between them. Methods: The final study sample included 48 adult volunteers (39 men and 9 women, mean age $24.14{\pm}3.16years$), after excluding 29 volunteers whose occlusion could not be evaluated by the T-Scan III system due to severe skeletal or occlusal problems. PAR index and OGS scores were assessed using dental study models, and measurements of centric occlusion, protrusive movement, and lateral excursion movement were obtained via the T-Scan III system. The results were analyzed to determine correlations. Results: Occlusal analysis by the T-Scan III system was clinically reliable (p < 0.05), and the PAR index and OGS scores were significantly correlated with several measurements obtained with the T-Scan III system (p < 0.05). Conclusions: The T-Scan III system is a quantitative and reliable method for occlusal evaluation, and represents a potential substitute for occlusal indexes. Compared to the PAR index, the OGS scores of more variables were significantly correlated with the T-Scan measurements.

A PRELIMINARY STUDY ON QUANTITATIVE ANALYSIS USING THE COMPUTERIZED T-SCAN SYSTEM (COMPUTERIZED T-SCAN SYSTEM을 이용한 정량적 교합분석방법에 관한 연구)

  • Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제27권2호
    • /
    • pp.271-277
    • /
    • 1989
  • The purpose of this preliminary report was to describe the operating procedure of T-scan system and to identify the location, timing and force of occlusal contact in patient with normal occlusion using computerized T-scan system. From the preliminary observation , the author obtained the following results. 1. T-scan system displayed 2 dimensional and 3 dimensional description of occlusion: contact locations, timing (sequence) and forces of occlusal contacts. 2. The T-scan sensor was the most important part of the T-scan system. 3. The data of T-scan system cannot be stored in computer diskett. 4. The T-scan system is thought to be the most effective system to detect occlusal contacts and can be applied to the followings : occlusal diagnosis, occlusal equilibration, crown and bridge restorative procedures, denture adjustment, implant procedures, splint adjustment, laboratory procedures, periodontal treatment, orthodontics, TMJ treatment and patient education etc.

  • PDF

Pattern Analysis of Occlusal Contacts During Lateral Excursion Using T-scan III System (T-scan III 시스템을 이용한 하악 측방운동 시 교합접촉 양상의 분석)

  • Lee, Sang-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제29권1호
    • /
    • pp.59-68
    • /
    • 2013
  • The objective of this study was to analyze occlusal contact pattern of 33 young adult males with normal occlusion during lateral excursion using T-scan III system which can measure the dynamic occlusion. Occlusal contact patterns were examined and categorized in non-working side disclusion point(more functionally acceptable position) not canine-to-canine position. Disclusion time, occlusal force, and occlusal force distribution ratio of upper canine at disclusion point during lateral excursion movement was also measured and compared among the groups divided according to contact patterns. The results showed that group function was clearly more dominant than canine guidance and other occlusal contact patterns different with existing patterns were found. There were significantly difference between groups in variables of T-scan measurement. T-scan III system is effective tools to analyze and evaluate occlusal contact patterns, disclusion time, occlusal force, and occlusal force distribution ratio of upper canine at disclusion point.

Comparison of two computerized occlusal analysis systems for indicating occlusal contacts

  • Jeong, Min-Young;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.49-54
    • /
    • 2020
  • PURPOSE. The purpose of this study was to compare the performance of Accura to that of the T-scan for indicating occlusal contacts. MATERIALS AND METHODS. Twenty-four subjects were selected. Their maxillary dental casts were scanned with a model scanner. The Stereolithography files of the casts were positioned to align with the occlusal plane. Occlusal surfaces of every tooth were divided into three to six anatomic regions. T-scan and Accura recordings were made during two masticatory cycles. The T-scan and Accura images were captured at the maximum bite force and overlapped to the cast. Photographs of interocclusal records were used as the reference during overlap. The occlusal contacts were counted to compare the T-scan and Accura. McNemar's test was used for statistical significance and the corresponding P-values were calculated from a chi-square distribution with one degree of freedom. The accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Accura were calculated relative to the T-scan values as a control. RESULTS. No statistical differences (P>.05) were found between the T-scan and Accura methods. The accuracy of Accura was 75.8%, sensitivity was 82.1%, specificity was 60.1%, PPV was 82.9%, and NPV was 60.1%. CONCLUSION. Accura could be another possible option as a computerized occlusal analysis system for indicating occlusal contacts at maximum intercuspation.

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제29권1호
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

An occlusal contact analysis of lateral mandibular movement using T-Scan system (T-Scan system을 이용한 하악 측방운동 시 교합접촉 분석)

  • Song, Joo-Hun;Joo, Se-Jin;Lee, Ho-Sun;Kang, Dong-Wan;Lee, Gyeong-Je
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제53권2호
    • /
    • pp.128-137
    • /
    • 2015
  • Purpose: Most of the former studies about the occlusal contact patterns during the mandibular movement focused on foreigner. The purpose of this study is analyzing the occlusal contacts of young Koreans by using T-Scan system. Materials and methods: The sample size was 87 and the occlusal contacts of each right and left lateral movements were measured from the maximum intercuspation to the 3mm excursive position for three times respectively. All of the occlusal contacts were double checked through the thin metal foil. The results were categorized as two; 1) considering occlusal contact patterns on working side only, 2) considering occlusal contact patterns on working and nonworking sides. Results: The results showed that the nonworking side occlusal contacts play major roles in the lateral mandibular movement. In both cases of considering with and without the nonworking side occlusal contacts, the group function was the most prevalent. In the working side, the contacts were the most frequent in canine and the frequency of contacts was decreased as the distance was increased from canine to molar. In the nonworking side, the contacts were the most frequent in second molar. And the gender factor was statistically significant (${\alpha}$=.05), as females have more nonworking side occlusal contacts in this study. Conclusion: Among the three factors of anterior guidance, the group function was the most dominant factor. The analysis of 87 samples showed that canine contact was the most frequent in the working side and second molar contact was the most common in the nonworking side.

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report (보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례)

  • Su-Hyun Choi;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제61권2호
    • /
    • pp.160-178
    • /
    • 2023
  • Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient's occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient's tooth loss. The patient's occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

Clinical Evaluation of Occlusal Contact Changes in Implant Prosthesis (임플란트 보철의 교합 접촉 변화에 대한 임상적 평가)

  • Yun, Chul-Hee;Kim, Dae-Gon;Yi, Yang-Jin;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제23권1호
    • /
    • pp.21-30
    • /
    • 2007
  • Despite of the successful clinical performance of implants, it is still lacking of the knowledge of changes in implant occlusion. The purpose of this study was to evaluate the changes of infraocclusal contact after clinical occlusal function of implant. Twenty patients(38 implants) were recalled during 10 months after placement of implant prosthesis. Occlusion changes were investigated at placement, placement 1 months, 4 months and 10 months serially with silicone bite material and T-Scan II sensor. Bony changes were also evaluated with periapical radiographs. The changes of silicone thickness and T-Scan II sensored areas were statistically analyzed with repeated measured ANOVA and the Scheffe's post-hoc test at the 95% significance level. The following results have been made based on this study: 1. Alveolar bone loss was within 0.20mm and it was generally concluded within physiologic level. 2. There were no statistically significant differences in the thickness changes of silicone material at 1 month and 4 months of occlusal function. However, there was statistically significant difference at 10 months of occlusal function (p<0.05). 3. There was no statistically significant difference in changes of occlusal contact area in T-Scan II at 1 month and 4 months of occlusal function, but there was statistically significant difference at 10 months of occlusal function (p<0.05). Conclusively, as time goes by, implant occlusion to be formed infraocclusion was to be far close and increased occlusal contact. However, it was not observed destructive bone resorption in periapical radiographs and any other side effects.

Evaluation of relationship between cognitive function and occlusal status in elderly individuals using the T-scan III® system (T-scan III® system을 이용한 일부지역 노인의 교합양상과 인지기능의 관련성)

  • Shin, Hae-Eun;Cho, Min-Jeong;Choi, Youn-Hee;Song, Keun-Bae
    • Journal of Korean Academy of Oral Health
    • /
    • 제41권2호
    • /
    • pp.96-101
    • /
    • 2017
  • Objectives: The aim of this study was to investigate the relationship between cognitive function and occlusal status in elderly individuals. Methods: A total of 162 individuals aged 65 years and older, who attended the senior citizen center in Daegu city, were included after consent for participation in the study was obtained. The Korean version of the Mini-Mental State Examination (MMSE-K) was used to evaluate the level of cognitive function. Occlusal status was determined using the T-scan $III^{(R)}$ system. All collected data were analyzed by ${\chi}^2$ test, t-test, one way ANOVA, and linear regression analysis using SPSS version 23.0 for Windows. Results: There was a significant relationship between the cognitive function and the use of dentures. Individuals with posterior occlusal status had higher MMSE-K scores than those with anterior occlusal status. There was a positive correlation between the cognitive function and posterior occlusal force. Conclusions: These results suggest that occlusal status was associated with cognitive function in the elderly individuals. Active national policies to improve occlusal condition in the elderly population are needed.

Occlusal Analysis in the Policemen with Temporomandibular Disorders Using T-scan II System (경찰 종사자의 측두하악장애환자에서 T-scan II System을 이용한 교합분석)

  • Lim, Hyun-Dae;Jung, Seung-Ah;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • 제31권4호
    • /
    • pp.365-373
    • /
    • 2006
  • This study suggested correction of excessive mouth opening or maximum occlusal contact to analyse occlusal contact time, occlusal contact number and force through evaluation of occlusal pattern in policemen with temporomandibular disorders. The community of policemen influence on temporomandibular disorder's development and progress due to other condition of mouth opening and maximal occlusal contact. Repeated training or changes of usual life style may cause imbalance of stomatognathic system including the masticatory muscle, then develop or aggravate pain of temporomandibular joints and associated structures. This study uses T-scan II system(Tekscan Co., USA) for evaluation on occlusal pattern may influence temporomandibular disorders, and then the subjects take a sensor at 20 mm opening for maximal occlusal contact force. The policemen with temporomandibualr disorders get more long time on maximum contact timing, more short on end contact timing, and more force on end contact force than general society's. So they get closure of mouth with more short time and more force, then transfer remaining load to temporomandibular joint. There are no statistically significances between affected side and occlusal pattern of occlusal contact time and force. There are Left -right dental arch imbalances seems on Rt. dental arch if affected side is right and Lt. dental arch if affected side is left. In above results, It's worth due consideration that policemen with temporomandibular disorders get more smooth mandibualr movement and less force on maximal occlusal contact position.