• Title/Summary/Keyword: oblique distance

Search Result 105, Processing Time 0.028 seconds

Vascular Anatomy of Peroneal Perforator Flap (비골 동맥 천공지 피판의 혈관 해부학)

  • Chung, Duke Whan;Han, Chung Soo;Hwang, Joon Sung
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.36-42
    • /
    • 2004
  • Materials and Methods: We studied 50 cases of peroneal perforating branch about branching pattern, course, length of vascular pedicle, and perforating level of the perforating cutaneous branches from Oct. 1985 to November 2003 by doppler flow meter and intraoperative findings. Results: 1) The perforating cutaneous branches were classified into four types, the Straight Branch (27cases), the Proximal Oblique Branch (11cases), the Branch from Muscular Artery (10cases), the Distal Oblique Branch(2 cases) respectively. The most common patten was Straight Branch, that was 54%. 2) There were 3 pathways of these branches, the most common one passed between the Soleus and Peroneus muscles(34 cases, 68%) 3) The length of vascular pedicle in Buoy Flap was variable from from 3 cm to 15 cm, but 32 cases(64%) were distributed between 5 cm and 6 cm. 4) The perforating level of branches were 5.9 cm in average from fibular neck to subcutaneous perforator artery 5) Peroneal Buoy Flap in possible to reconstruct both seperated bone and skin defect in some distance by One-Stage Operation and we can harvest maximal $8{\times}16cm$ sized flap in one perforating artery. If we include more two perforating artery, we get more wide flap which can cover large defect.

  • PDF

A study on an oblique impinging jet (경사충돌분류에 관한 연구)

  • 조용철;김광용;박상규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.716-724
    • /
    • 1990
  • Oblique impinging plane jets were investigated experimentally and numerically at Reynolds number 21000. The inclination angle was varied from 90.deg.(normal to the impinging plate) to 60.deg.. The distance H between the nozzle exit and the stagnation point on the impinging plate was fixed at H/D=8. The working fluid was air. The mean velocity components and turbulent quantities were measured by a hot-wire anemometer. And the static pressure distributions on the impinging plate were measured by a Pitot tube. In numerical computation, the governing partial differential equations of elliptic type were solved with conventional k-.epsilon. turbulence model. The measurements show that, after impingement, the jet half width alone the wall increases in both directions, and that similarity for each turbulent quantity such as Reynolds shear stress or turbulent kinetic energy is revealed in the wall jet region. The computed results show some deviation from experimental data in the impingement region, where streamline curvature is significant. However, the computed results agree qualitatively well with measurements.

Machinability in Oblique Powder Blasting of Glass (유리의 경사 미립분사가공시 가공성)

  • 박동삼;서태일
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.28-34
    • /
    • 2004
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for brittle materials such as glass, silicon and ceramics, capable of producing micro structures larger than 100${\mu}{\textrm}{m}$. In this study, we introduced oblique powder blasting, and investigated the effect of the impacting angle of particles, the scanning times and the stand-off distance on the surface roughness and the weight-loss rate of samples with no mask, and the wall profile and overetching of samples with different mask pattern in powder blasting of soda-lime glass. The varying parameters were the different impact angles between 50$^{\circ}$ and 90$^{\circ}$, scanning times of nozzle up to 40 and the stand-off distances 70mm and 100mm. The widths of mask pattern were 0.2mm, 0.5mm and 1mm. The powder was alumina sharp particles, WA #600. The mass flow rate of powder during the erosion test was fixed constant at 175g/min and the blasting pressure of powder at 0.2Mpa.

Accuracy of virtual 3-dimensional cephalometric images constructed with 2-dimensional cephalograms using the biplanar radiography principle

  • Lee, Jae-Seo;Kim, Sang-Rok;Hwang, Hyeon-Shik;Lee, Kyungmin Clara
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.407-412
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the accuracy of virtual 3-dimensional (3D) cephalograms constructed using the principle of biplanar radiography by comparing them with cone-beam computed tomography (CBCT) images. Materials and Methods: Thirty orthodontic patients were enrolled in this study. Frontal and lateral cephalograms were obtained with the use of a head posture aligner and reconstructed into 3D cephalograms using biplanar radiography software. Thirty-four measurements representing the height, width, depth, and oblique distance were computed in 3 dimensions, and compared with the measurements from the 3D images obtained by CBCT, using the paired t-test and Bland-Altman analysis. Results: Comparison of height, width, depth, and oblique measurements showed no statistically significant differences between the measurements obtained from 3D cephalograms and those from CBCT images (P>0.05). Bland-Altman plots also showed high agreement between the 3D cephalograms and CBCT images. Conclusion: Accurate 3D cephalograms can be constructed using the principle of biplanar radiography if frontal and lateral cephalograms can be obtained with a head posture aligner. Three-dimensional cephalograms generated using biplanar radiography can replace CBCT images taken for diagnostic purposes.

Morphometric Analysis of the Ureter with Respect to Lateral Lumbar Interbody Fusion Using Contrast-Enhanced Computed Tomography

  • Chunneng Huang;Zhenyu Bian;Liulong Zhu
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.2
    • /
    • pp.155-161
    • /
    • 2023
  • Objective : To analyze the anatomical location of the ureter in relation to lateral lumbar interbody fusion and evaluate the potential risk of ureteral injury. Methods : One hundred eight patients who performed contrast-enhanced computed tomographic scans were enrolled in this study. The location of the ureter from L2-L3 to L4-L5 was evaluated. The distances between the ureter and psoas muscle, intervertebral disc, and retroperitoneal vessels were also recorded bilaterally. Results : Over 30% of the ureters were close to the working corridor of extreme lumbar interbody fusion at L2-L3. Most of the ureters were close to working corridor of oblique lumbar interbody fusion, especially at L4-L5. The distance from the ureter to the great vessels on the left side was significantly narrowing from L2-L3 to L4-L5 (28.8±9.5 mm, 22.0±8.0 mm, 15.5±8.4 mm), and it was significantly larger than that on the right side (12.3±6.1 mm, 7.4±5.7 mm, 5.4±4.4 mm). Conclusion : Our findings indicate that the location of the ureter varies widely among individuals. To avoid unexpected damage to the ureter, it is imperative to directly visualize it and verify the ureter is not in the surgical pathway during lateral lumbar interbody fusion.

Immediate Effects of the Pronation Squat on the Genu Varum and the Muscles Around the Knee (엎침 스쿼트 운동이 안굽이와 무릎 주위 근육에 미치는 즉각적 효과)

  • Kim, Hyeon-Su;Kim, Kyoung-Don
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.4
    • /
    • pp.299-309
    • /
    • 2021
  • Purpose : The purpose of this study was to compare the ankle pronation squat with the general squat and investigate the effect on the geun varum and the muscles around the knee. Methods : Subjects were chosen as the target for squat exercise with the distance between the knees more than 5 cm. The selected 30 students were randomly divided into 15 pronation squat group and 15 general squat group, and performed five sets movements 20 times. Global postural system (GPS) and digital goniometer were used to check the distance between the knees and the Q angle, and muscle activity was measured with EMG during squat exercise. Results: The result is as follows. First, as a result of analyzing the change in the distance between the knees, the distance between the knees decreased and the Q angle increased in the pronation squat group after exercise. Second, as a result of analyzing the change in muscle activity of the peroneus longus, the muscle activity increased in the pronation squat group after exercise, and it was more effective than the general squat group. Third, as a result of analyzing the change in the VMO (vastus medialis oblique) and VL (vastus lateralis) muscle activity ratio, the activity ratio of the pronation squat group increased after exercise, and the imbalance in the VMO/VL muscle activity was decreased. Conclusion: The pronation squat exercise applied to the ankle will greatly affect what is made into a balanced leg as decreased of the distance between knees, increased of Q angle, increased of the muscle activity of the peroneus longus and the ratio of VMO/VL.

Heat Transfer Characteristics of Water Jet Impinging on Oblique Surface (경사면(傾斜面)에 충돌(衝突) 하는 수분류(水噴流)의 열전달(熱傳達) 특성(特性)에 관(關)한 연구(硏究))

  • Choi, Guk-Gwang;Na, Gi-Dae;Kim, Yeun-Young;Jeon, Sung-Taek;Lee, Jong-Su
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 1993
  • The purpose of this research is to investigate the characteristics of heat transfer in the downward axisymmetric free water jet system impinged on a flat oblique plate which has the uniform heat flux. Experimental conditions considered were Reynolds number, distance between nozzle and Bat plate, inclination angle of heater surface and nozzle exit velocity. Local Nusselt number was subjected to the influence of Re number, Pr number, oblique angle of heating surface and local position of flat plate. In the wall region of downward surface, The secondary peak point of heat transfer appeared at the local point of X/D=-8 from the stagnation point. The stagnation heat transfer rate of this experimental study augments 2.4 times than that of laminar theorical solution. The stagnation nusselt number is function of Reynolds number, nozzle-plate spacing Prandtl number and oblique angle of impinging plate.

  • PDF

A Study on the Radiography for Sharpness the Image of the Sternum Bone in X-ray Thoracic Cage (가슴우리 X-ray 촬영에서 복장뼈의 선예한 영상을 얻기 위한 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.329-336
    • /
    • 2021
  • The Study studied the Inspection Method of Images to obtain a sharp image of the Costume among the bones Composed of Thoracic Using the Thoracic Cage Rando Phantom. At 80 cm of the phantom Distance at the X-ray tube focus, the position of the Phantom was Examined by Changing the Rt and Lt Posterior Oblique(LAO) and Rt and Lt Posterior Postero Oblique positions by 20°, 25° and 30°. The acquired images were Subjectively Evaluated by the Radiographer, and the Evaluation data were analyzed as SPSS ver. 3.0. The signal-to-noise ratio (SNR) was Calculated using the ImageJ Program. As a result, the Cronbach Alpha value was Significantly higher at 0.789. The results of the Signal-to-Noise Ratio (SNR) were high at 20° to 6.038 in the right posterior Transcription Direction at the time of Examination and 7.860, in the Supine Position, for images of Sternum bones. In conclusion, it is Believed that the patient position can be obtained from the Right Anterior Oblique(RAO) Position 20° if the X-ray technique is used to obtain the Sternum's advanced image, and the Left Anterior Oblique(LAO) Position 25° when filming in the Rght lying position.

An Analysis of the Surface Anatomical Location of the Posterior-inferior Margin of the Sacroiliac Joint (천장관절 후하연의 표면해부학적 위치 분석)

  • Cho, Kwang Yeon;Kim, Bum Su;Kim, Won Oak;Yoon, Duck Mi;Yoon, Kyung Bong
    • The Korean Journal of Pain
    • /
    • v.22 no.1
    • /
    • pp.47-51
    • /
    • 2009
  • Background: The blind sacroiliac joint (SIJ) block cannot always be performed accurately; it is commonly performed in the office based setting because intraarticular and periarticular injections are effective for SIJ pain. However, knowledge on the surface anatomy of the SIJ is lacking. The purpose of this study was to analyze the surface anatomical location of the posterior-inferior margin of the SIJ. Methods: After informed consent was obtained, fifty patients undergoing SIJ block in the prone position were examined. The oblique angles where the anterior-inferior margin and the posterior-inferior margin of the SIJ overlap on X-ray were evaluated. In addition, the surface anatomical relationships between the posterior-inferior margin of the SIJ on X-ray and the posterior superior iliac spine (PSIS) and sacral hiatus by palpation were assessed. Results: The oblique angle was $5.4{\pm}2.9^{\circ}$. The vertical and transverse distance between the posterior-inferior margin of the SIJ and PSIS were $3.8{\pm}0.8cm$ and $0.9{\pm}0.6cm$, respectively. The vertical and transverse distance between the posterior-inferior margin of the SIJ and the midpoint of the sacral hiatus were $3.4{\pm}0.7cm$ and $3.9{\pm}0.6cm$, respectively. Only the vertical distance between the posterior-inferior margin of the SIJ and PSIS showed significant difference between the male and the female groups (P = 0.0016). Conclusions: The measurements in this study can be used as a reference standards for the blind SIJ block.

Effects of Contraction of Abdominal Muscles on Electromyographic Activities of Superficial Cervical Flexors, Rib Cage Elevation and Angle of Craniocervical Flexion During Deep Cervical Flexion Exercise (심부경부굴곡 운동 시 복근 수축이 표면경부굴곡근의 근활성도, 흉곽 거상, 두개경부굴곡 각도에 미치는 영향)

  • Park, Kyue-Nam;Won, Jong-Hyuck;Lee, Won-Hwee;Chung, Sung-Dae;Jung, Doh-Heon;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.16 no.3
    • /
    • pp.9-15
    • /
    • 2009
  • The purpose of this study was to examine contraction of abdominal muscles on surface electromyographic (EMG) activity of superficial cervical flexors, rib cage elevation and angle of craniocervical flexion during deep cervical flexion exercise in supine position. Fifteen healthy subjects were participated for this study. All subjects performed deer cervical flexion exercise with two methods. The positions of two methods were no volitional contraction of abdominal muscles in hook-lying position with 45 degree hip flexion (method 1) and 90 degrees hip and knee flexion with feet off floor for inducing abdominal muscle contraction (method 2). Surface EMG activities were recorded from five muscles (sternocleidmastoid, anterior scaleneus, recuts abdominis, external oblique, internal oblique). And distance of rib cage elevation and angle of craniocervical flexion were measured using a three dimensional motion analysis system. The EMG activity of each muscle was normalized to the value of reference voluntary contraction (%RVC). The EMG activities, distance of rib cage elevation. and angle of craniocervical were compared using a paired t-test between two methods. The results showed that the EMG activities of sternocleidmastoid and anterior scaleneus during deep cervical flexion exercise in method 2 were significantly decreased compared to method 1 (p<.05). Distance of rib cage elevation and angle of craniocervical flexion were significantly decreased in method 2 (p<.05). The findings of this study indicated that deep cervical flexion exercise with contraction of abdominal muscles could be an effective method to prevent substitute motion for rib cage elevation and contraction of superficial neck flexor muscles.

  • PDF