• Title/Summary/Keyword: oblique distance

Search Result 106, Processing Time 0.025 seconds

Surgical Treatment of the Fifth Metatarsal Base Fracture Using Multiple Kirschner Wires (다발성 Kirschner 강선을 이용한 제 5중족골 기저부 골절의 수술적 치료)

  • Kim, Jihyeung;Kim, Jang Woo;Lee, Jeong Ik;Kim, Sang Kil;Rhee, Seung Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.1
    • /
    • pp.24-28
    • /
    • 2014
  • Purpose: The purpose of this study is to evaluate the clinical and radiographic results of internal fixation using multiple Kirschner wires (K-wires) for the fifth metatarsal base fracture. Materials and Methods: We retrospectively reviewed 14 patients with a displaced fifth metatarsal base fracture. We measured the distance of fracture displacement on the foot oblique radiograph pre- and post-operatively. We evaluated the clinical results using the visual analog pain scale at six weeks and three months postoperatively and the American Orthopaedic Foot and Ankle Society (AOFAS) mid-foot score at six months postoperatively. Results: In our series, 10 cases were zone I fracture and four cases were zone II fracture. We achieved anatomical reduction and bony union in all of our cases. The average time to bone union was 43 days. The degree of pain around the fifth metatarsal base was significantly decreased after surgery. The average AOFAS score was 95 at six months postoperatively. Conclusion: Multiple K-wire fixation is a relatively simple fixation method for displaced fifth metatarsal base fractures. If we place a K-wire into the medial cortex of the fifth metatarsal, we could prevent proximal migration of the K-wire.

A Study on Model Establishment and Structural Analysis for Gun Blast Load (기총 폭발 하중에 대한 모델 수립과 구조 해석에 관한 연구)

  • Kim, Dae-Kwan;Han, Jae-Hung;Jang, Jae-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.7
    • /
    • pp.33-39
    • /
    • 2005
  • A mathematical model, GUNBLAST, of blast waves emitted from a gun muzzle is established, and structural response analyses for the blast load are performed. The blast wave can be divided into two kinds of waves, free field and reflected blast waves. In this research, the free field blast wave model is established by the use of a scaling approach, and the reflected blast wave is calculated by using the oblique shock theory and computational fluid dynamic calculation. GUNBLAST is applied to two kinds of structural models. To investigate the effect of the muzzle distance from a structural surface, the blast waves on a plate for various muzzle distances are compared to uniform loads. Moreover, the transient response analysis of an aircraft wing model with a 12.7mm gun is carried out by using MSC/NASTRAN. From the results, it can be shown that the blast wave can cause broad random vibration and high frequency damage to equipments mounted in the aircraft.

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

The Study of the Abnormal Refraction Eye of the Primary School Children in Daegu (대구지역 초등학생 굴절이상안에 대한 연구)

  • Kim, Dae Nyoun;Kim, Hye Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.49-53
    • /
    • 2001
  • To investigate the visual acuity of the primary school children. the visual acuity test wan performed the object and subject method. The results were follows. 1. The eye types were 94.8% positive for myopia, 1.2% for emmetropia and 4.0% hyperopia, respectively. 2. The abnormal refraction eyes were 71.3% positive for simple myopia, 17.9% for myopic compound astigmatism, 6.9% for myopic simple astigmatism, and 2.5% for simple hyperopia, 0.6%for hyperopic compound astigmatism, 0.8%for hyperopic simple astigmatism, respectively. 3. The axis of astigmatism were 72.8% for astigmatism with-the-rule, 23.2% for astigmatism against-the-rule, 4.0% for astigmatism oblique, respectively. 4. On the total myopic spheric power, the -0.50

  • PDF

The Study for Refractive Error of the Westerner in 20s: North America Region (20대 서양인의 굴절이상에 대한 연구: 북미지역)

  • Lee, Young-Il;Hong, Jin Seok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.97-101
    • /
    • 2009
  • Purpose: To assess the refractive state of the westerners (male: 44, female: 62) in twenties who visited the A optical shop at Seoul. Methods: The visual acuity test was performed by the objective and subjective method. Results: The emmetropia and myoptia were 35 and 177 eyes (83.49%), respectively. About 26.76% of tested males was ametropia. Myopia compound and myopia simple astigmatism were found in 60.56% and 12.68% of tested males, respectively. However, about 43.40% of tested females was ametropia. Myopia compound and myopia simple astigmatism were 49.06% and 7.55% were found in tested females, respectively. As for the equivalent spheric power of myopic abnormal refractive eyes, the -0.5D < spheric equivalent ${\leq}$ -2.00D was 35.02% of tested westerners, the -2.00D < spheric equivalent ${\leq}$ -6.00D was 60.45% and anything over the -6.00D was 4.53%. The percentages of with-the-rule, against-the-rule and oblique astigmatism among people with astigmatism were 59.82%, 26.78% and 13.40%, respectively. The average of pupillary distance in male (63.5${\pm}$2.4 mm) was greater than that in female (59.7${\pm}$2.3 mm). Conclusions: Korean opticians were provided some useful information about making up a prescription for the westerners in twenties by this research.

  • PDF

A study on the search and selection processes of targets presented on the CRT display (컴퓨터 모니터에 제시된 표적의 탐색과 선택과정에 관한 연구)

  • 이재식;신현정;도경수
    • Korean Journal of Cognitive Science
    • /
    • v.11 no.2
    • /
    • pp.37-51
    • /
    • 2000
  • The present study compared computer users target-selection response patterns when the targets were varied in terms of their relative location and distance from the current position of the cursor. In Experiment 1, where the mouse was used as an input device, the effects of different directions and distances of simple target(small rectangle) on target-selection response were investigated. The results of Experiment 1 can be summarized as follows: (1) Overshooting was more frequent than either undershooting or correct movement and (2) this tendency was more prominent when the targets were presented in the oblique direction or in farther location from the current cursor position. (3) Although the overshooting and undershooting were more frequent in the oblique direction, the degree of deviation was larger in horizontal and vertical direction. (4) Time spent in moving the mouse rather than that spent in planning, calibrating or clicking was found to be the most critical factor in determining total response time. In Experiment 2, effects of the font size and line-height of the target on target-selection response were compared with regard to two types of input devices(keyboard vs. mouse). The results are as follows: (1) Mouse generally yielded shorter target-selection time than keyboard. but this tendency was reversed when the targets were presented in horizontal and vertical directions. (2) In general, target-selection time was the longest in the condition of font size of 10 and line-height of 100%, and the shortest in the condition of font size of 12 and line-height of 150%. (3) When keyboard was used as the input device, target-selection time was shortest in the 150% line-height condition, whereas in the mouse condition, target-selection time tended to be increased as the line-height increased. which resulted in the significant interaction effect between input device and line-height. Finally, several issues relating to human-computer interaction were discussed based on the results of the present study.

  • PDF

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

Morphology and Size of Clinical Crowns of Permanent Maxillary Molars in College Students (일부 대학생의 상악 대구치 임상치관의 형태와 크기)

  • Jeon, Eun-Suk;Lee, Jung-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.7
    • /
    • pp.285-296
    • /
    • 2010
  • This study was implemented among 100 students of C College of Public Health who have healthy permanent dentition in order to measure the morphology and sizes of clinical crowns of permanent maxillary molars. The following are conclusions of this study. 1. The cusp height, crown width, crown thickness of clinical crowns appeared to be bilaterally symmetrical. 2. The strong development of the buccal groove showed to be superior in the right first molar. The appearance rate of the buccal pit was high in the right first molar also. 3. The type 4th cusp appeared as 100% in the left and right first molars, and 78%, 75% in the left and right second molars respectively. 4. The distal lingual cusp(DLC) size were bilaterally symmetrical in the type 4th cusp. 5. As for the distance between two cusp tips, it was large between mesial cusp tips in all of the first and second molars at both sides. 6. Development of the Carabelli's cusp was high in both the left and right first molars. 7. The appearance rate of the oblique ridge was 87.0% in the right first molar, 73.0% in the right second molar, 88.0% in the left first molar, and 73.0% in the left second molar. This is considered to be caused by people who have mild dental crown caries in their first molars. 8. The appearance rate of the mesial marginal ridge tubercle(DMRT) was high in both of the left and right first molars. That of the distal tubercle was 16.0% in the right first molar, 26.0% in the right second molar, 14.0% in the left first molar, and 21% in the left second molar.

High-Altitude Environment Simulation of Space Launch Vehicle in a Ground-Test Facility (지상시험장비를 통한 우주발사체 고공환경모사 기법 연구)

  • Lee, Sungmin;Oh, Bum-Seok;Kim, YoungJun;Park, Gisu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.11
    • /
    • pp.914-921
    • /
    • 2017
  • The experimental research on a high-altitude environment simulation of space launch vehicle is important for securing independent technologies with launching space vehicles and completing missions. This study selected an altitude of 65 km for the experiment environment where it exceeded Mach number of 6 after the launch of Korean Space Launch Vehicle(KSLV-II). Shock tunnel was used to replicate the flight condition. After flow establishment, in order to confirm aerodynamic characteristics and normal and oblique shockwaves, the flow verification was carried out by measuring stagnation pressure and heat flux of a forebody model, and shockwave stand-off distance of a hemispherical model. In addition, a shock-free technique to recover free-stream condition has been developed and verified. From the results of the three verification tests, it was confirmed that the flow was replicated with the error of about ${\pm}3%$. The error between the slope angle of inclined shockwave of the scaled down transition section model using the shock-free shape and the slope angle of the horizontal plate model, and between the theoretical and the experimental value of the static pressure of the model were confirmed to be 2% and 1%, respectively. As a result, the efficiency of the shockwave cancellation technique has been verified.

Evaluation on Reinforcing Effect of Inclined System Bolting by Model Tests and Numerical Analysis (모형시험 및 수치해석을 통한 경사 시스템 록볼트의 보강효과 분석)

  • Lee, Jea-Dug;Kim, Byoung-Il;Yoo, Wan-Kyu;Han, Jin-Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1529-1539
    • /
    • 2013
  • Recent case studies in Japan have shown that rockbolts are commonly installed at an oblique angle to the excavation direction of the tunnel, instead of at a right angle, due to restriction of the working space. In particular, in the case of expansion in an existing tunnel, the working space can be very small, due to the large protective structures necessary to operate within an existing tunnel. In this case, where both the current use of the existing tunnel, and the reinforcement of the ground around the tunnel are required, the effects of installation angles and patterns of rockbolts are important factors in the design process. Therefore, in this study, a total number of 24 model tests are performed, to investigate the reinforcing effects of system bolting installed obliquely from the excavation direction of the tunnel, by changing the installation angle of bolts, longitudinal distance, and bonded length of bolts. The model test results indicate that the relaxed load ratio decreases, with the increase of both the bonded lengths and the number of the installed bolts, resulting in the decrease of the supported area by one bolt. Two-dimensional numerical analysis, which considered the reinforcement effect of inclined system bolting as the change of engineering properties near the tunnel, demonstrated that the deflection patterns at the tunnel crown in the numerical simulations, show a similar tendency to those measured in the model tests.