• 제목/요약/키워드: oblique distance

검색결과 106건 처리시간 0.027초

비골 동맥 천공지 피판의 혈관 해부학 (Vascular Anatomy of Peroneal Perforator Flap)

  • 정덕환;한정수;황준성
    • Archives of Reconstructive Microsurgery
    • /
    • 제13권1호
    • /
    • pp.36-42
    • /
    • 2004
  • Materials and Methods: We studied 50 cases of peroneal perforating branch about branching pattern, course, length of vascular pedicle, and perforating level of the perforating cutaneous branches from Oct. 1985 to November 2003 by doppler flow meter and intraoperative findings. Results: 1) The perforating cutaneous branches were classified into four types, the Straight Branch (27cases), the Proximal Oblique Branch (11cases), the Branch from Muscular Artery (10cases), the Distal Oblique Branch(2 cases) respectively. The most common patten was Straight Branch, that was 54%. 2) There were 3 pathways of these branches, the most common one passed between the Soleus and Peroneus muscles(34 cases, 68%) 3) The length of vascular pedicle in Buoy Flap was variable from from 3 cm to 15 cm, but 32 cases(64%) were distributed between 5 cm and 6 cm. 4) The perforating level of branches were 5.9 cm in average from fibular neck to subcutaneous perforator artery 5) Peroneal Buoy Flap in possible to reconstruct both seperated bone and skin defect in some distance by One-Stage Operation and we can harvest maximal $8{\times}16cm$ sized flap in one perforating artery. If we include more two perforating artery, we get more wide flap which can cover large defect.

  • PDF

경사충돌분류에 관한 연구 (A study on an oblique impinging jet)

  • 조용철;김광용;박상규
    • 대한기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.716-724
    • /
    • 1990
  • 본 연구에서는 2차원 경사충돌분류에 대한 실험을 수행하였고, 이 결과를 수] 치해석에 의한 계산치와 비교하였다. 실험에서는 난류특성을 구명하기 위하여 열선 풍속계를 사용해 충돌각의 변화에 따른 평균속도, 각 난류응력성분, 압력등을 측정하 였다.수치해석을 위한 난류모델로는 표준 K-.epsilon.모델을 사용하였다.

유리의 경사 미립분사가공시 가공성 (Machinability in Oblique Powder Blasting of Glass)

  • 박동삼;서태일
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.28-34
    • /
    • 2004
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for brittle materials such as glass, silicon and ceramics, capable of producing micro structures larger than 100${\mu}{\textrm}{m}$. In this study, we introduced oblique powder blasting, and investigated the effect of the impacting angle of particles, the scanning times and the stand-off distance on the surface roughness and the weight-loss rate of samples with no mask, and the wall profile and overetching of samples with different mask pattern in powder blasting of soda-lime glass. The varying parameters were the different impact angles between 50$^{\circ}$ and 90$^{\circ}$, scanning times of nozzle up to 40 and the stand-off distances 70mm and 100mm. The widths of mask pattern were 0.2mm, 0.5mm and 1mm. The powder was alumina sharp particles, WA #600. The mass flow rate of powder during the erosion test was fixed constant at 175g/min and the blasting pressure of powder at 0.2Mpa.

Accuracy of virtual 3-dimensional cephalometric images constructed with 2-dimensional cephalograms using the biplanar radiography principle

  • Lee, Jae-Seo;Kim, Sang-Rok;Hwang, Hyeon-Shik;Lee, Kyungmin Clara
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.407-412
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the accuracy of virtual 3-dimensional (3D) cephalograms constructed using the principle of biplanar radiography by comparing them with cone-beam computed tomography (CBCT) images. Materials and Methods: Thirty orthodontic patients were enrolled in this study. Frontal and lateral cephalograms were obtained with the use of a head posture aligner and reconstructed into 3D cephalograms using biplanar radiography software. Thirty-four measurements representing the height, width, depth, and oblique distance were computed in 3 dimensions, and compared with the measurements from the 3D images obtained by CBCT, using the paired t-test and Bland-Altman analysis. Results: Comparison of height, width, depth, and oblique measurements showed no statistically significant differences between the measurements obtained from 3D cephalograms and those from CBCT images (P>0.05). Bland-Altman plots also showed high agreement between the 3D cephalograms and CBCT images. Conclusion: Accurate 3D cephalograms can be constructed using the principle of biplanar radiography if frontal and lateral cephalograms can be obtained with a head posture aligner. Three-dimensional cephalograms generated using biplanar radiography can replace CBCT images taken for diagnostic purposes.

Morphometric Analysis of the Ureter with Respect to Lateral Lumbar Interbody Fusion Using Contrast-Enhanced Computed Tomography

  • Chunneng Huang;Zhenyu Bian;Liulong Zhu
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권2호
    • /
    • pp.155-161
    • /
    • 2023
  • Objective : To analyze the anatomical location of the ureter in relation to lateral lumbar interbody fusion and evaluate the potential risk of ureteral injury. Methods : One hundred eight patients who performed contrast-enhanced computed tomographic scans were enrolled in this study. The location of the ureter from L2-L3 to L4-L5 was evaluated. The distances between the ureter and psoas muscle, intervertebral disc, and retroperitoneal vessels were also recorded bilaterally. Results : Over 30% of the ureters were close to the working corridor of extreme lumbar interbody fusion at L2-L3. Most of the ureters were close to working corridor of oblique lumbar interbody fusion, especially at L4-L5. The distance from the ureter to the great vessels on the left side was significantly narrowing from L2-L3 to L4-L5 (28.8±9.5 mm, 22.0±8.0 mm, 15.5±8.4 mm), and it was significantly larger than that on the right side (12.3±6.1 mm, 7.4±5.7 mm, 5.4±4.4 mm). Conclusion : Our findings indicate that the location of the ureter varies widely among individuals. To avoid unexpected damage to the ureter, it is imperative to directly visualize it and verify the ureter is not in the surgical pathway during lateral lumbar interbody fusion.

엎침 스쿼트 운동이 안굽이와 무릎 주위 근육에 미치는 즉각적 효과 (Immediate Effects of the Pronation Squat on the Genu Varum and the Muscles Around the Knee)

  • 김현수;김경돈
    • 대한통합의학회지
    • /
    • 제9권4호
    • /
    • pp.299-309
    • /
    • 2021
  • Purpose : The purpose of this study was to compare the ankle pronation squat with the general squat and investigate the effect on the geun varum and the muscles around the knee. Methods : Subjects were chosen as the target for squat exercise with the distance between the knees more than 5 cm. The selected 30 students were randomly divided into 15 pronation squat group and 15 general squat group, and performed five sets movements 20 times. Global postural system (GPS) and digital goniometer were used to check the distance between the knees and the Q angle, and muscle activity was measured with EMG during squat exercise. Results: The result is as follows. First, as a result of analyzing the change in the distance between the knees, the distance between the knees decreased and the Q angle increased in the pronation squat group after exercise. Second, as a result of analyzing the change in muscle activity of the peroneus longus, the muscle activity increased in the pronation squat group after exercise, and it was more effective than the general squat group. Third, as a result of analyzing the change in the VMO (vastus medialis oblique) and VL (vastus lateralis) muscle activity ratio, the activity ratio of the pronation squat group increased after exercise, and the imbalance in the VMO/VL muscle activity was decreased. Conclusion: The pronation squat exercise applied to the ankle will greatly affect what is made into a balanced leg as decreased of the distance between knees, increased of Q angle, increased of the muscle activity of the peroneus longus and the ratio of VMO/VL.

경사면(傾斜面)에 충돌(衝突) 하는 수분류(水噴流)의 열전달(熱傳達) 특성(特性)에 관(關)한 연구(硏究) (Heat Transfer Characteristics of Water Jet Impinging on Oblique Surface)

  • 최국광;나기대;김은영;전성택;이종수
    • 태양에너지
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 1993
  • 하향(下向)의 축대칭자유분류(軸對稱自由噴流)가 등열유속(等熱流束) 조건(條件)의 경사전열면(傾斜傳熱面)에 충돌(衝突)하는 축대칭(軸對稱) 충돌수분류계(衝突水噴流系)를 구성(構成)하였다. 실험변수(實驗變數)로는 노즐-전열면간 거리(距離), 레이놀즈수, 무차원경사각(無次元傾斜角)으로 하였으며, 노즐-전열면간 거리의 범위는 $1.5{\sim}10.5$, 레이놀즈수의 범위(範圍)는 $1{\times}10^4{\sim}4{\times}10^4$, 무차원 경사각의 범위는 0.5, 0.67, 0.83, 1.00으로 하였다. 이와같은 실험적(實驗的) 연구(硏究)에서 국소누셀트수는 $Re^{0.7}$에 비례(比例)하여 증가(增加)되었으며 또한 정체점(停滯點)으로부터 국소거리(局所距離)가 8배(培)되는 하향구배전열면(下向句配傳熱面)의 국소위치(局所位置)에 제2(第)의 극대(極大) 열전달(熱傳達) 현상(現像)이 나타났다. 국소누셀트수는 분류속도가 저속(低速)의 경우 전열면(傳熱面)의 경사각의 영향이 작게 나타나고 있으나, 고속영역(高速領域)이 됨에 따라 경사각의 영향이 증가(增加)되었으며, 특히 국소위치의 $X/D{\leq}4$는 벽면분류영역(壁面噴流領域)에서 경사각에 대한 영향이 명확(明確)하게 나타나고 있다. 정체점열전달(停滯點熱傳達)은 분류속도(噴流速度)와 노즐-전열면간 거리에 비례(比例)해서 증가(增加)되며 층류이론해(層流理論解)에 비(比)하여 최소(最少) 2.4배(培) 이상 높은 열전달효과(熱傳達效果)를 나타내었으며, 정체점(停滯點)누셀트수는 레이놀즈수, 프란틀수, 노즐-전열면간 거리 그리고 무차원(無次元) 경사각(傾斜角)을 포함(包含)하는 무차원(無次元) 실험식(實驗式)으로 나타내었다.

  • PDF

가슴우리 X-ray 촬영에서 복장뼈의 선예한 영상을 얻기 위한 촬영법 연구 (A Study on the Radiography for Sharpness the Image of the Sternum Bone in X-ray Thoracic Cage)

  • 안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.329-336
    • /
    • 2021
  • 본 연구는 Thoracic cage Rando Phantom을 이용하여 가슴우리 구성하는 뼈중에서 복장의 선예한 영상을 얻고자 영상의 검사방법을 연구하였다. 엑스선관 초점에서 팬톰거리는 80Cm에서 엑스선관 각도에는 수직으로 팬톰의 자세는 우측 및 좌측의 후전사방향과 우측 및 좌측 전후 사방향 자세로 20°, 25°, 30° 변경하여 검사하였다. 획득한 영상을 방사선사가 주관적으로 영상평가 하였으며, 평가 데이터를 SPSS ver. 3.0으로 분석하였다. ImageJ Program을 이용하여 신호대잡음비(SNR)를 계산하였다. 그 결과 Cronbach Alpha 값이 0.789로 유의하게 높았다. 신호대잡음비(SNR)의 결과는 갈비과 정확한 복장뼈의 영상을 얻고자 할 때는 엎드린 자세에서는 검사 시 우측 후전사방향 20°에서 6.038으로 높았으며 바로누운자세에서는 좌측 전후사 방향 25° 검사 시 에서 7.860으로 높았다. 결론으로 복장뼈의 선예한 영상을 얻고자 엑스선 촬영기법으로 엎드려서 촬영할 경우에는 환자자세를 우측후전사방향 20°에서 또한 바로누운자세에서 촬영 할 경우에는 좌측전후사방향 25°에서 촬영기법을 이용한다면 선예한 영상을 얻을 수 있으리라 사료된다.

천장관절 후하연의 표면해부학적 위치 분석 (An Analysis of the Surface Anatomical Location of the Posterior-inferior Margin of the Sacroiliac Joint)

  • 조광연;김범수;김원옥;윤덕미;윤경봉
    • The Korean Journal of Pain
    • /
    • 제22권1호
    • /
    • pp.47-51
    • /
    • 2009
  • Background: The blind sacroiliac joint (SIJ) block cannot always be performed accurately; it is commonly performed in the office based setting because intraarticular and periarticular injections are effective for SIJ pain. However, knowledge on the surface anatomy of the SIJ is lacking. The purpose of this study was to analyze the surface anatomical location of the posterior-inferior margin of the SIJ. Methods: After informed consent was obtained, fifty patients undergoing SIJ block in the prone position were examined. The oblique angles where the anterior-inferior margin and the posterior-inferior margin of the SIJ overlap on X-ray were evaluated. In addition, the surface anatomical relationships between the posterior-inferior margin of the SIJ on X-ray and the posterior superior iliac spine (PSIS) and sacral hiatus by palpation were assessed. Results: The oblique angle was $5.4{\pm}2.9^{\circ}$. The vertical and transverse distance between the posterior-inferior margin of the SIJ and PSIS were $3.8{\pm}0.8cm$ and $0.9{\pm}0.6cm$, respectively. The vertical and transverse distance between the posterior-inferior margin of the SIJ and the midpoint of the sacral hiatus were $3.4{\pm}0.7cm$ and $3.9{\pm}0.6cm$, respectively. Only the vertical distance between the posterior-inferior margin of the SIJ and PSIS showed significant difference between the male and the female groups (P = 0.0016). Conclusions: The measurements in this study can be used as a reference standards for the blind SIJ block.

심부경부굴곡 운동 시 복근 수축이 표면경부굴곡근의 근활성도, 흉곽 거상, 두개경부굴곡 각도에 미치는 영향 (Effects of Contraction of Abdominal Muscles on Electromyographic Activities of Superficial Cervical Flexors, Rib Cage Elevation and Angle of Craniocervical Flexion During Deep Cervical Flexion Exercise)

  • 박규남;원종혁;이원휘;정성대;정도헌;오재섭
    • 한국전문물리치료학회지
    • /
    • 제16권3호
    • /
    • pp.9-15
    • /
    • 2009
  • The purpose of this study was to examine contraction of abdominal muscles on surface electromyographic (EMG) activity of superficial cervical flexors, rib cage elevation and angle of craniocervical flexion during deep cervical flexion exercise in supine position. Fifteen healthy subjects were participated for this study. All subjects performed deer cervical flexion exercise with two methods. The positions of two methods were no volitional contraction of abdominal muscles in hook-lying position with 45 degree hip flexion (method 1) and 90 degrees hip and knee flexion with feet off floor for inducing abdominal muscle contraction (method 2). Surface EMG activities were recorded from five muscles (sternocleidmastoid, anterior scaleneus, recuts abdominis, external oblique, internal oblique). And distance of rib cage elevation and angle of craniocervical flexion were measured using a three dimensional motion analysis system. The EMG activity of each muscle was normalized to the value of reference voluntary contraction (%RVC). The EMG activities, distance of rib cage elevation. and angle of craniocervical were compared using a paired t-test between two methods. The results showed that the EMG activities of sternocleidmastoid and anterior scaleneus during deep cervical flexion exercise in method 2 were significantly decreased compared to method 1 (p<.05). Distance of rib cage elevation and angle of craniocervical flexion were significantly decreased in method 2 (p<.05). The findings of this study indicated that deep cervical flexion exercise with contraction of abdominal muscles could be an effective method to prevent substitute motion for rib cage elevation and contraction of superficial neck flexor muscles.

  • PDF