• Title/Summary/Keyword: oblique

Search Result 1,719, Processing Time 0.026 seconds

DC V-I Characteristics of a High Temperature Superconductor for a 600 kJ Superconducting Magnetic Energy Storage Device in an Oblique External Magnetic Field (경사 외부자장에 대한 600 kJ급 SMES용 HTS도체의 DC V-I 특성)

  • Li, Zhu-Yong;Ma, Yong-Hu;Ryu, Kyung-Woo;Choi, Se-Yong;Kim, Hae-Jong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.79-84
    • /
    • 2008
  • We are developing a small-sized high temperature superconducting magnetic energy storage (HTS-SMES) magnet with the nominal storage capacity of 600 kJ, which provides electric power with high quality to sensitive electric loads. Critical current and N-value of a high temperature superconductor with large current, which was selected for the development of the 600 kJ HTS-SMES magnet, were investigated in various oblique external magnetic fields. Based on the critical current and N-value measured for the short sample conductor, we discussed the DC V - I characteristic of a model coil fabricated with the same conductor of 500 m. The results show that the measured critical current and N-value of the conductor for parallel field are constant in external magnetic fields less than about 0.2 T. However, for oblique fields, its critical current and N -value abruptly decrease in all external magnetic fields. Moreover, the measured critical current of the model coil well agrees with the numerically calculated one based on the DC V - I characteristic measured for the short sample conductor. This suggest that losses and critical currents for an HTS-SMES magnet made up of a high temperature superconductor with anisotropic characteristic are predictable from the data of a short sample conductor.

OBLIQUE TRANSCRANIAL RADIOGRAPHIC ANALYSIS OF CHANGES IN CONDYLE POSITION FOLLOWING SAGITTAL SPLIT RAMUS OSTEOTOMY IN MANDIBULAR PROGNATHISM (측사위경두개방사선사진(Oblique Transcranial Radiograph)을 이용한 하악전돌증환자의 하악지 시상골절단술후 하악과두위치변화 분석)

  • Kwon, Tae-Geon;Jang, Hyun-Jung;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.1
    • /
    • pp.32-45
    • /
    • 1995
  • This study was intended to evaluate condyle position and the relationship of condyle position change and post surgical relapse following the sagittal split ramus osteotomy for mandible setback in 25 patients by paired t-test and multiple regression analysis. We used oblique transcranial and cephalometric radiographs taken before operation, immediate after operation, and at least 6 months post operatively. 1. In oblique transcranial view, posterior joint space was decreased immediate after operation and increased 6 months after operation. To compare the measurement before and 6 months after operation, there was no statistically significant change in over all joint spaces(P>0.05). 2. The joint spaces changed under the 0.2mm were 30%, 0.2mm to 1.0mm were 60.7%, above 1.0mm were 9.3%. This result reveals that condyle position was relatively reproduced to pre-operative state. 3. Statistically, the amount of mandible set back didn't influence the post operative relapse(P>0.05). 4. Statistically, the amount of mandible set back didn't influence the condylar displacement(P>0.05), and the amount of joint space change didn't influence the post operative relapse.(P>0.05) The changes in joint space is in the standard tracing error or within the adaptive capacity of the individual, it was too small to influence the stability of surgery.

  • PDF

Usefulness of the Oblique Radiographic View in Ankle Fractures (족근 관절 골절에서 사면상 단순 방사선 사진의 유용성)

  • Cho, Duck-Yun;Song, Sang-Jun;Yoon, Hyung-Ku;Han, Soo-Hong;Chang, Ji-Hoon;Yoon, Byung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.94-98
    • /
    • 2005
  • Purpose: To compare the radiographic evaluations between two radiographic views (AP and lateral views) and four radiographic views (AP, lateral and both oblique views) in ankle fractures. Materials and Methods: From January 2000 to June 2002, 60 cases of ankle fractures were treated with open reduction and internal fixation and its followed up periods were at least 2 years. All cases were classified into three groups according to the method of preoperative radiographic evaluation. Two radiographic views (AP and lateral views) were taken in group A and four radiographic views (AP, lateral and both oblique views) were taken in group B. 12 Cases were evaluated with three dimensional computed tomography (3D CT). Four radiographic views and 3D CT were taken in group C. All cases were classified according to the Danis-Weber and Lauge-Hansen classification. Displacement of fracture fragment of medial, lateral, posterior malleolus and size of fracture fragment of posterior malleous were measured using picture archiving communication system (PACS). Results: Although kappa value between two or four radiographic views were good or excellent in Danis-Weber classification and Lauge-Hansen classification of ankle fractures, the displacements of medial and lateral malleoli were statistically different. Four radiographic views evalulated the degree of displacement of medial and lateral fragments more accurately compared to two radiographic views. Conclusion: Four radiographic views will be more useful than two radiographic views to decide the method of treatment and operation considering the displacement of fracture fragment.

  • PDF

Report of the Oblique Ionospheric Sounding Results from Korea to Japan

  • Bae, Seok-Hee;Park, Chung-Rim;Wee, Kyu-Jin;Akira Ohtani;Mikitoshi Nagayama;Kiyoshi Igarashi
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.22 no.1
    • /
    • pp.1.2-5
    • /
    • 1994
  • Ionospheric sounding experiments have been conducted at RRL (Radio Research Laboratory), Ministry of Communications, using Digisonde 256 since its installation in 1990. Routine observations of the vertical sounding are carried out 48 times (or 39 times) a day, at every 24 hour. In addition, we also made oblique sounding experiments to obtain the real time data of Maximum Usable Frequency (MUF) and detect the anomalous HF propagation, as a part of the joint study between RRL and CRL (Communications Research Laboratory) of Japan. The two stations involved in the study were Anyang (RRL, Korea) and Kokubunji (CRL, Japan). The ionosondes used in both stations were Digisonde 256, developed by ULCAR (University of Lowell, Center for Atmospheric Research), U. S. A. , and the synchronization of time was accomplished with the help of GPS receiver. During most part of the experiments RRL transmitted non-modulated pulses, and CRL received them. The experiment was scheduled from October 25 through October 29, 1993. However, the ionosphere was not developed well enough to conduct the experiment with pre-set operation parameters. The experiment became successful (from 0500 UT to 0800 UT, October 29) only after the operation parameters had been changed, and the continuous ionograms were obtained by CRL at 0718 UT and 0733 UT in October 29, 1993. We believe this type of experiment will ensure the qualitative enhancement of solar-terrestrial physics research and a routine observation of the oblique ionospheric sounding. In this report, we present the results of the fore-mentioned oblique sounding as well as the vertical sounding results obtained by Digisonde 256 at Anyang station of RRL.

  • PDF

Variations in Stroke Patients' Muscle Activity during Head Rotation in Non-Paretic-Side Weight Bearing

  • Lee, Kwan-Sub;Choe, Han-Seong;Lee, Byung-Joo
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.159-163
    • /
    • 2015
  • Purpose: This study aimed to determine the interaction among the neck, trunk, and lower extremities on the non-paretic side in head rotation along with non-paretic-side weight shifting of stroke patients. To compare stroke patients' ability to control posture through muscle activity variation related to pertubation during head rotation along with the non-paretic limb. Methods: We tested 15 hemiplegic patients and 15 normal individuals. Each group's muscle activity was measured by electromyography in neutral head position and head rotation position. We compared each group's resu lt based on measured values in patients' non-paretic neck muscles, trunk muscles, and lower limbs muscles activation. Results: The study showed that muscle activity increased in the sternocleidomastoid muscle (102.26%, 53.00%), splenius capitis muscle (97.93%, 54.93%), erector spinae muscle (241.00%, 127.60%), external oblique abdominal muscle (256.66%, 152.00%), and internal oblique abdominal muscle (252.80%, 152.6%), peroneus longus muscle (117.53%, 137.13%) and gastrocnemius muscle (119.06%, 137.20%), while the results for the sternocleidomastoid muscle, splenius capitis muscle, erector spinae muscle, external oblique abdominal muscle, internal oblique abdominal muscle, peroneus longus muscle, and gastrocnemius muscle showed a statistically significant difference (p<0.05). Conclusion: It is hard for stroke patients to engage in normal movement control under suggested conditions because of the insufficient movement against gravity on the stroke patient's non-paretic side and impaired cooperative patterns. To solve these problems, patients need their bodies to improve through effective movement, resulting in advanced control of their effective and functional activity.

The Effects of Varying Degrees of Backrest on Abdominal Muscles and Back Extensor Activation During Lower Extremity Exercise (하지운동 시 등받이의 각도가 복근과 요부 신전근의 활성도에 미치는 영향)

  • Cynn, Won-Suk;Lee, Young-Rok;Chang, Young-Jin;Choi, In-Yong
    • Physical Therapy Korea
    • /
    • v.11 no.1
    • /
    • pp.19-25
    • /
    • 2004
  • The purpose of this study was to investigate the effects of backrests of varying degrees ($90^{\circ}$, $100^{\circ}$, $110^{\circ}$) on three abdominal muscles (upper rectus abdominis, external oblique, internal oblique) and back extensor activation during lower extremity exercise. The three different conditions during bilateral knee extention exercise were: (1) leaning on a chair with a $90^{\circ}$ backrest, (2) leaning on a chair with a $100^{\circ}$ backrest, (3) leaning on a chair with a $110^{\circ}$ backrest. Fifteen healthy muscle subjects (mean age=24.2 years [SD=2.96], mean height=175.6 cm [SD=7.46], mean weight=69.1 kg [SD=7.36]) with no history of neuromusculoskeletal disease voluntarily participated in this study. Electromyography was used to collect muscle activation, and the muscle activation was expressed as a percentage of maximal voluntary isometric contraction (%MVIC). Repeated one-way analysis of variance (ANOVA) was used to determine the statistical significance. The results were as follows: (1) upper rectus abdominis, external oblique, internal oblique activation measured significantly lower. (2) measured significantly lower when lower degree.

  • PDF

Performance Comparison of Pressure Sensitive Paint and Pressure Field Measurement of Oblique Impinging Jet (Pressure Sensitive Paint의 성능비교 및 경사충돌분류의 압력장 측정)

  • Lee, Sang-Ik;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.7
    • /
    • pp.1031-1038
    • /
    • 2002
  • The pressure sensitive paint (PSP) has recently received a considerable attention in the fields of aerodynamics and fluid mechanics as a new revolutionary optical technique to measure pressure fields on a body surface. In this study, the feasibility and effectiveness of the PSP pressure field measurement technique have been investigated experimentally. Seven different PSP formulations including two porphyrins(PtOEP and PtTFPP) and four polymers(Polystyrene, cellulous acetate butyrate, GP-197 and Silicon-708) were tested to check the performance and characteristics of each combination. The static calibration of each PSP formulation was carried out in a constant-pressure chamber. The PSP technique was applied to an oblique impinging jet flow to measure variation of pressure field on the impinging plate at on oblique jet angle of ${\theta}=60^{\circ}$. Pressure field images were captured by an 12bit intensified CCD(ICCD, $1K{\times}1K$)camera. As a result, the dynamic response of PSP depends on the oxygen permeability of polymer and the photochemical interaction between luminophore and polymer as well as the reaction of luminophore itself. The reaction of luminophore was changed by employing different polymers. In conclusion, Among 7 PSP formulation tested, the combination of PtTFPP and cellulous acetate butyrate show the best performance. In addition, the detail pressure field of an oblique high-speed impinging jet was measured effectively using the PSP technique.

3-D Numerical Study on a Oblique Jet Impingement for Fluid flows and Heat Transfer Characteristics Using ${\kappa}-{\varepsilon}-\bar {{\upsilon}'^ 2}$ Model (${\kappa}-{\varepsilon}-\bar {{\upsilon}'^ 2}$ 모델을 이용한 경사진 충돌제트의 유동장 및 열전달 특성에 대한 3차원 수치해석적 연구)

  • Choi, Bong-Jun;Lee, Jung-Hee;Choi, Young-Ki
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.789-794
    • /
    • 2000
  • The Paper studies the flow and heat transfer characteristics to a jet impinging at different oblique angles, to a plane surface by numerical methods. The flowfield and heat transfer rate associated with the oblique Impingement of an axisymmetric jet are of interest as a result of its presence in numerous technological Problems. For the computation of heat transfer rate, the standard ${\kappa}-{\varepsilon}$ and ${\kappa}-{\varepsilon}-\bar {{\upsilon}'^ 2}$ turbulent model were adapted. The accuracy of the numerical calculations was compared with various experimental data reported in the literature. ${\kappa}-{\varepsilon}-\bar {{\upsilon}'^ 2}$ model showed better agreement with experimental data than standard ${\kappa}-{\varepsilon}$ model in prediction of the turbulent intensity and the heat transfer rate. In the case of computation of flowfield, the study carries on the ${\alpha}=45$ deg, h/D=4.95. The jet Reynolds number based on the nozzle diameter(D), was 48,000. For the computation of heat transfer rate, the Re=20,000, the jet orifice-to-plate spacings(L/D) are 4, 6 and 10, and the angle between the axis of the jet orifice and the plate surface is set at 30, 45, 60, or 90 deg. For the smaller spacings, the near-peak Nusselt numbers are not significantly effected by the initial decreases in the Jet angle. The overall shape of the local Nusselt number x-axis profile is influenced by both the jet orifice-to-plate spacing and the jet angle.

  • PDF

Effects of the Abdominal Hollowing Technique Applied during Plank Exercises at Different Angles between Ground and the Humerus on Abdominal Stabilization Muscle Activity

  • Kim, Jeong Wook;Park, Min Chull
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.2
    • /
    • pp.94-100
    • /
    • 2020
  • Purpose: This study examined the effects of the abdominal hollowing technique applied during plank exercises at different shoulder angles between the ground and the humerus on the abdominal muscle activity Methods: The subjects were 36 male volunteers. They were randomized to perform plank exercises or plank exercises using the hollowing technique at 80˚, 90˚, 100˚, and 110˚ between the ground and the humerus. The abdominis muscles were measured using a surface electromyogram. Independent t-tests examined the changes in the activity of these muscles according to the two exercise methods at each angle. The changes in muscle activity were examined according to the selected angles by one-way analysis of variance. Results: The activity of abdominal muscles was investigated according to the angle between the ground and the humerus during the plank exercise. As a result, the muscle activity increased significantly with decreasing angle in the rectus abdominis, external oblique, and internal oblique·transverse abdominis muscles (p<0.05). In terms of the changes in abdominal muscle activity after hollowing plank exercises at the given angles between the ground and the humerus, an increase in angle resulted in a statistically significant increase in the rectus abdominis muscle activity (p<0.05). The activities of the rectus abdominis, external oblique, and internal oblique/transverse abdominis muscles after hollowing plank exercises showed statistically significant increases (p<0.05) compared to those after plank exercises. Conclusion: The hollowing technique and the increase in the angle between the ground and the humerus may be an effective exercise method for increasing the muscle activity of the abdominis muscles.

The usability of the image according to the frequency encoding gradient direction conversion in fixation using the non magnetic metal screw (비 자성 금속 screw를 이용한 고정술에서 주파수 부호화 경사 방향 변환에 따른 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-So
    • Journal of Digital Contents Society
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Because of causing the geometrical transformation of the magnetic field, the patient implementing the fixation using the nonmagnetic metal screw causes the magnetic susceptibility artifact at an image. Thus, in this research, the distortion measure of the image according to the frequency oblique direction conversion tried to be compared in the magnetic susceptibility artifact occurence. First, the itself phantom inserting the nonmagnetic metal screw of the titanium component was made and the region of interest was set up and the frequency oblique direction the anterior - back side was converted to the right-to-left direction in the axial image and a right-to-left was converted to the upper side - bottom side in the coronal plane and the upper - bottom side was converted to the anterior - back side in the sagittal plane and the distortion measure of the region of interest was compared, it observed. In a result, when converting the frequency oblique direction, the distortion difference of the region of interest could be confirmed and it is considered to enhance the diagnostics efficiency changing the oblique direction appropriately.