• 제목/요약/키워드: objective mirror

검색결과 61건 처리시간 0.12초

승용차용 후사경의 진동 저감을 위한 강건최적설계 (Robust Optimization of the Automobile Rearview Mirror for Vibration Reduction)

  • 황광현;이광원;박경진
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.198-206
    • /
    • 1999
  • An automobile outside rear view mirror system has been analyzed and designed to reduce vibration with a finite element model. model analysis is conducted for the calculation of natural frequencies. harmonic analysis is utilized to estimate the displacements of the glass surface under dynamic loads. The model is verified with the vibration experiment of the parts and the assembled body. The structure of the mirror system is optimized for the robustness defined by the Taguchi concept. At first, many potential design variables are defined. Final design variables are selected based on the amount of contribution on the objective function. That is, sensitive variables are chose. The SN ratio in the Taguchi method is replaced by an objective function with the mean and the standard deviation of the quality characteristic. The defined objective function is appropriate in the structural design in that the vibration displacements are minimized while the robustness is improved.

  • PDF

인공위성 카메라 주반사경의 위상최적화 (Topology Optimization of the Primary Mirror of a Multi-Spectral Camera)

  • 박강수;장수영;이응식;윤성기
    • 대한기계학회논문집A
    • /
    • 제26권6호
    • /
    • pp.1194-1202
    • /
    • 2002
  • A study on the topology optimization of a multi-spectral camera for space-use is presented. The optimization is carried out under self-weight and polishing pressure loading. A multi-spectral camera for space-use experiences degradation of optical image in the space, which can not be detected on the optical test bench on the earth. An optical surface deformation of a primary mirror, which is a principal component of the camera system, is an important factor affecting the optical performance of the whole camera system. In this study, topology optimization of the primary mirror of the camera is presented. As an objective function, a measure of Strehl ratio is used. Total mass of the primary mirror is given as a constraint to the optimization problem. The sensitivities of the objective function and constraint are calculated by direct differentiation method. Optimization procedure is carried out by an optimality criteria method. For the light-weight primary mirror design, a three dimensional model is treated. As a preliminary example, topology optimization considering a self-weight loading is treated. In the second example, the polishing pressure is also included as a loading in the topology optimization of the mirror. Results of the optimized design topology for the mirror with various mass constraints are presented.

리어뷰 미러의 실차 동특성 및 주행시 동적 안정성(회전각)에 대한 평가 (On the Evaluation of In-Vehicle Dynamic Characteristics and On-Road Dynamic Stability(Angle of Rotation) of Rearview Mirror)

  • 정승균;이근수;김증한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.385-386
    • /
    • 2008
  • Dynamic stability of the vehicle rearview mirror is an important factor for the driver's visual perception (image blur) when driving down the road and regarded as one of the vehicle level N&V performance of visible component vibration. Several projects within GM identified a set of objective metrics and validation methods that can replace current existing subjective evaluation of mirror stability. This paper presents objective evaluation results for assessing dynamic stability (angle of rotation) of the vehicle rearview mirrors using both in-lab FRF measurements and on-road testing.

  • PDF

인공위성 카메라 주반사경의 위상 최적화 (Topology Optimization of the Primary Mirror of a Multi-Spectral Camera)

  • 박강수;장수영;이응식;윤성기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.920-925
    • /
    • 2001
  • A study on the topology optimization of a multi-spectral camera for space-use is presented. A multi-spectral camera for space-use experiences degradation of optical image in the space, which can not be detected on the optical test bench on the earth. An optical surface deformation of a primary mirror, which is a principal component of the camera system, under the self-weight loading is an important factor affecting the optical performance of the whole camera system. In this study, topology optimization of the primary mirror of the camera is presented. Total mass of the primary mirror is given as a constraint to the optimization problem. The sensitivities of the objective function and constraint are calculated by direct differentiation method. Optimization procedure is carried out by an optimality criterion method using the sensitivities of the objective function and the constraint. As a preliminary example, topology optimization considering a self-weight loading is treated. For practical use, the polishing pressure is included as a loading in the topology optimization of the primary mirror. Results of the optimized design topology for the primary mirror with varying mass ratios are presented.

  • PDF

A study of the mirror design and the fabrication for an X-ray microscope

  • Kim, Woo-Soon;Kim, Kyong-Woo;Yoon, Kwon-Ha;Kim, Dong-Hyun;Namba, Yoshiharu
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.59-64
    • /
    • 2002
  • One of the exciting research areas of the X-ray microscope is the observation of a living cell. In order to study a living cell with high resolution the order of the several tens nm, we need to improve the efficiency of mirrors which are components of an X-ray microscope system. In this paper we present the mirror design and manufacture to give a high resolution and reflectivity. We designed Wolter type I the condenser and objective mirror with the several tens of nm resolution. According to mirror design. we made the program using the visual basic. Using the new processing method as well as the ultra-precision diamond cutting, we directly processed the inside of an aluminum hulk in order to manufacture mirrors. From the experimental result, we think that the new processing method will improve a high reflectivity through the improved cutting tools and optimum cutting conditions.

  • PDF

경량화 반사경의 최적설계에 관한 연구 (A study on optimum design of a lightweight mirror)

  • 박강수;박현철;조지현;윤성기;이준호
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.443-448
    • /
    • 2003
  • 인공위성 카메라에 장착되는 반사경의 경량화 설계를 위해 최적설계법을 적용하였다. 최적설계 과정에서 목적함수로는 카메라가 탑재된 인공위성의 발사비용을 줄이기 위해 반사경의 무게를 최소화하는 것으로 설정하였다. 반사경의 자중에 의한 변형(피크-밸리값) 및 고유진동수의 크기를 제한조건으로 두었다. 최적화 프로그램은 DOT(Design Optimization Tools)를 이용하여 유한차분법으로 설계변수에 따른 목적함수와 제한조건의 민감도를 구하였고 구성한 최적설계 프로그램의 검증을 위해 검증예제를 다루었다. 또한 최적설계로 부터 얻은 결과값으로 부터 반사경의 유한요소모델을 구성하고 유한요소해석 및 광학적 물성치 해석프로그램을 연계한 통합프로그램을 통하여 최적설계 결과 검증을 수행하였다. 최종적으로 위의 최적설계 프로그램을 이용하여 유효직경이 600mm인 반사경을 설계하였다.

반사형 Focal Reducer를 가지는 높은 개구수의 대물렌즈 설계 (Optical Design of a High-numerical-aperture Objective with a Reflective Focal Reducer)

  • 이종웅
    • 한국광학회지
    • /
    • 제34권6호
    • /
    • pp.248-260
    • /
    • 2023
  • 낮은 NA의 굴절형 대물렌즈와 반사형 focal reducer로 구성된 NA 0.5의 굴절-반사 대물렌즈를 설계하였다. 굴절형 대물렌즈로는 NA 0.25인 Lister 대물렌즈가 사용되고, 반사형 focal reducer는 구면수차, 코마, 비점수차가 보정된 2구면경계가 사용되었다. 설계된 굴절-반사 대물렌즈는 높은 NA를 가졌음에도 18 mm의 긴 작동거리와 NA 0.25의 Lister 대물렌즈보다 개선된 결상성능을 가지고 있다.

Video Based Behavioral Analysis to Observe Attention during Mirror Therapy in Hemiplegic Patients : Preliminary Study

  • Kim, Jinmin;Song, Changho
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권2호
    • /
    • pp.212-216
    • /
    • 2021
  • Objective: Mirror therapy is one of the promising methods suggested for the upper limb rehabilitation of stroke patients. While mirror therapy was presented to be effective in improving motor function of stroke patients, problems were raised as preceding studies had various methods in applying mirror therapy. Some studies even reported no effect in mirror therapy. Our supposition for the reason of such problems was a decrease of attention on the illusive image during mirror therapy of stroke patients, and we aimed to observe this. Design: A cross-sectional preliminary study. Methods: Three hemiplegic acute patients were recruited for the traditional mirror therapy. It lasted for 30 minutes, and 12 different tasks were asked to perform. All procedures were video-recorded, and Observer XT was used to analyse mirror-gazing time, gaze-distracted time, preparation time, frequency of mirror gazing, frequency of distraction, frequency of preparation for treatment. Results: Subjects spent an average of 4-5 minutes having instructions about the mirror therapy intervention (preparation duration), an average of 11 minutes watching the mirror during therapy (mirror-gazing duration), and the rest of 14-15 minutes looking around the environment (gaze-distracted duration). During the mirror therapy, the number of distracted moments (frequency of distraction) was eight times more than focusing on the mirror (frequency of mirror gazing). Conclusions: Once the patient looks at the mirror, it only lasts about 5 seconds on average. Thus, we confirmed that patients could not concentrate on the illusion during the session and therefore it may have affected the effectiveness of the therapy.

자동차 블랙박스를 위한 미러 비전 (Mirror vision for car Black box)

  • 김은호;임명섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.369-372
    • /
    • 2007
  • about commercial business of car black box, mirror vision for car black box deal with analysis of Existing Car Black boxes in market to provide the objective information associated with surrounding scene of car instead of witness, we experimented on suitable structure of all direction to cover surrounding of car considering dead zone where can't see at short distance and realized simple structure of gathering scene using mirror and lens and by saving the number of camera and MUX of pre-circut

  • PDF

거울영상을 이용한 3차원 좌표해석에 관한 연구 (A Study on Three-dimensional Coordinates Analysis Using Mirror Images)

  • 유복모;이현직;정영동;오창수
    • 한국측량학회지
    • /
    • 제4권1호
    • /
    • pp.25-36
    • /
    • 1986
  • 지상사진으로 3차원 대상물에 대한 모든면의 절대좌표를 구하기 위해서는 최소 세쌍 이상의 모델이 필요하게 된다. 본 연구에서는 거울을 영상매개체로 이용하여 한쌍의 입체모델을 촬영하므로서 대상물의 모든면에 대한 3차원 좌표를 분석할 수 있는 기법을 연구하였으며, 거울면의 왜곡을 보정하기 위한 오차보정함수를 도입하여 거울영상기법의 정확성과 효용성을 증진시키는데 목적이 있다. 거울평면 방정식을 이용하여 거울에 투영된 점을 실제대상물상의 동일점으로 변환한 결과 X좌표의 오차가 가장크게 나타났으며, Y, Z좌표에서는 1mm 정도의 절대좌표오차를 나타내었고, 좌우거울의 보정함수를 도입하여 거울에 의한 왜곡을 보정하므로서 근거리 사진측량의 기대정확도에 만족됨을 알 수 있었다.

  • PDF