• Title/Summary/Keyword: objective evaluation

Search Result 5,085, Processing Time 0.038 seconds

Development and Analyses of Effects of ICT Teaching: Learning Process Plan for 'Designing My Home' unit of Technology.Home Economic in High School (ICT활용 교수.학습 과정안 개발 및 효과 분석: 고등학교 기술.가정 "나의 주거 공간꾸미기" 단원을 중심으로)

  • Park Hyun-Sook;Cho Jae-Soon
    • Journal of Korean Home Economics Education Association
    • /
    • v.18 no.2 s.40
    • /
    • pp.15-27
    • /
    • 2006
  • The purpose of this research was to develop and analyze the effects of ICT based teaching learning process plans for 'Designing My Home' unit of Technology Home Economics subject in High School. The seven housing contents were selected from 8 textbooks and 8 teaching resources at the analyses stage. A specific homepage(ieduhome.cafe.com) was built to utilize the eight ICT teaching learning process plan as well as many other resources at the planning & development stages. The number of 68 highschool students have participated for the application stage during September 4-26, 2003 and the same number have studied the same contents through regular teaching learning plans as a comparison group. Experimental groups have significantly more increased in the knowledge and understanding of the housing contents than have comparison groups. The same results occurred in the interests in Home Economics, Housing, and Internet utilized study. The Design reports were not statistically differed between two groups based on the objective evaluation criteria. The results of this study generally supported previous research and showed that the In teaching learning plans were more effective in various aspects than were the regular plans.

  • PDF

Estimation of Load-Settlement Curves of Embedded Piles Combining Results of End of Initial Driving and Restrike Dynamic Pile Tests (초기항타 및 재항타 동재하시험 결과를 조합한 매입말뚝의 하중-침하량 곡선 산정)

  • Seo, Mi Jeong;Park, Jong-Bae;Park, Min-Chul;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.7
    • /
    • pp.15-28
    • /
    • 2020
  • As the skin friction of an embedded pile is produced by the cement paste injected into the borehole, the skin friction cannot be evaluated by the end of initial driving test, which is conducted before the cement paste is cured. In addition, the total resistance of an embedded pile may not be properly evaluated during the restrike test if the base resistance is not fully mobilized because of the insufficient driven energy. The objective of this study is to suggest a new load-settlement curve of embedded piles by combining the results of the end of initial driving and restrike tests. Test piles are installed at fields by using the embedded pile method, and the results of the dynamic pile tests are analyzed using CAse Pile Wave Analysis Program (CAPWAP) after the end of initial driving and restrike tests are conducted. A new load transfer curve, which combines the behaviors of the pile base at the end of initial driving and of the pile shaft at the restrike, is suggested, and a new load-settlement curve is obtained. Subsequently, the resistances of the test piles are evaluated using the combined load-settlement curve, and compared with the results from the end of initial driving and restrike tests. The results showed that the resistances, which are evaluated using the combined load-settlement curve, may overcome the underestimation of the resistance because of the insufficient driven energy. In addition, the resistance resulted from the combined load-settlement curve may be more similar to that from the static load test because the suggested load transfer curve is closer to the behavior of the embedded pile compared to the results of end of initial driving and restrike tests. Therefore, this study demonstrates that the combined load-settlement curve may be effectively used for the evaluation of the bearing capacity of embedded piles.

Quality Evaluation of Juanbyeo as Aseptic-packaged Cooked Rice (무균포장밥 가공 적합품종 주안벼의 식미특성)

  • Oh, Sea-Kwan;Kim, Dae-Jung;Cheun, A-Reum;Yoon, Mi-Ra;Hong, Ha-Cheol;Choi, Im-Soo;Oh, Yea-Jin;Oh, Ki-Back;Kim, Yeon-Kyu
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.721-726
    • /
    • 2010
  • The objective of this study was to evaluate several varieties of aseptic-packaged cooked rice including Juanbyeo. Quality evaluations, such as by amylose, setback, toyo values and amylograms, were significantly higher in the Juanbyeo as compared to other samples. In addition, the Juanbyeo aseptic-packeged cooked rice showed significantly higher palatability characteristics and had a greater water absorption ratio than the other samples. For cold cooked rice, the relationship between palatability and texture was significantly high (p<0.01). Ilpumbyeo showed high scores for taste as a hot cooked rice, but as a cold cooked rice taste scores were lower than other samples. In the case of Juanbyeo cold cooked rice flavor was improved. When the Juanbyeo aseptic-packaged cooked rice was reheated in a microwave oven, it had better palatability than other varieties. Thus, the results of this study suggested that Juanbyeo can be effectively utilized as aseptic-packaged cooked rice.

Primary Synchronous Lung Cancer Detected using Autofluorescence Bronchoscopy (자가 형광 기관지 내시경을 이용한 동시성 원발성 폐암의 진단)

  • Kwon, Sun Jung;Lee, Yun Seun;Joung, Mi Kyong;Lee, Yu Jin;Jang, Pil Soon;Lee, Jeung Eyun;Chung, Chae Uk;Park, Hee Sun;Jung, Sung Soo;Kim, Sun Young;Kim, Ju Ock
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.645-652
    • /
    • 2006
  • Objective: Patients with lung cancer have a relative high risk of developing secondary primary lung cancers. This study examined the additional value of autofluorescence bronchoscopy (AFB) for diagnosing synchronous lung cancers and premalignant lesions. Methods: Patients diagnosed with lung cancer from January 2005 to December 2005 were enrolled in this study. The patients underwent a lung cancer evaluation, which included white light bronchoscopy (WLB), followed by AFB. In addition to the primary lesions, any abnormal or suspicious lesions detected during WLB and AFB were biopsied. Results: Seventy-six patients had non-small cell lung cancer (NSCLC) and 23 had small cell lung cancer (SCLC). In addition to the primary lesions, 84 endobronchial biopsies were performed in 46 patients. Five definite synchronous cancerous lesions were detected in three patients with initial unresectable NSCLC and in one with SCLC. The secondary malignant lesions found in two patients were considered metastatic because of the presence of mediastinal nodes or systemic involvement. One patient with an unresectable NSCLC, two with a resectable NSCLC, and one with SCLC had severe dysplasia. The detection rate for cancerous lesions by the clinician was 6.0% (6/99) including AFB compared with 3.0% (3/99) with WLB alone. The prevalence of definite synchronized cancer was 4.0% (4/99) after using AFB compared with 2.0% (2/99) before, and the staging-up effect was 1.0% (1/99) after AFB. Since the majority of patients were diagnosed with advanced disease, the subjects with newly detected cancerous lesions did not have their treatment plans altered, except for one patient with a stage-up IV NSCLC who did not undergo radiotherapy. Conclusions: Additional AFB is effective in detecting early secondary cancerous lesions and is a more precise tool in the staging workup of patients with primary lung cancer than with WLB alone.

Genotype $\times$ Environment Interaction of Rice Yield in Multi-location Trials (벼 재배 품종과 환경의 상호작용)

  • 양창인;양세준;정영평;최해춘;신영범
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.6
    • /
    • pp.453-458
    • /
    • 2001
  • The Rural Development Administration (RDA) of Korea now operates a system called Rice Variety Selection Tests (RVST), which are now being implemented in eight Agricultural Research and Extension Services located in eight province RVST's objective is to provide accurate yield estimates and to select well-adapted varieties to each province. Systematic evaluation of entries included in RVST is a highly important task to select the best-adapted varieties to specific location and to observe the performance of entries across a wide range of test sites within a region. The rice yield data in RVST for ordinary transplanting in Kangwon province during 1997-2000 were analyzed. The experiments were carried out in three replications of a random complete block design with eleven entries across five locations. Additive Main effects and Multiplicative Interaction (AMMI) model was employed to examine the interaction between genotype and environment (G$\times$E) in the biplot form. It was found that genotype variability was as high as 66%, followed by G$\times$E interaction variability, 21%, and variability by environment, 13%. G$\times$E interaction was partitioned into two significant (P<0.05) principal components. Pattern analysis was used for interpretation on G$\times$E interaction and adaptibility. Major determinants among the meteorological factors on G$\times$E matrix were canopy minimum temperature, minimum relative humidity, sunshine hours, precipitation and mean cloud amount. Odaebyeo, Obongbyeo and Jinbubyeo were relatively stable varieties in all the regions. Furthermore, the most adapted varieties in each region, in terms of productivity, were evaluated.

  • PDF

Effect of DEHP Administration on Reproduction in Pregnant Mice Ⅱ. Effect of DEHP Administration on Reproductive Characteristic and Blood Components in Pups Born after DEHP Administration in Pregnant Mice (임신중인 생쥐에 DEHP 투여가 번식현상에 미치는 영향 Ⅱ. 임신중인 생쥐에 DEHP 투여가 자손의 번식특성과 혈액성분에 미치는 영향)

  • Park, Dong-Heon;Jang, Hyun-Yong;Park, Choon-Keun;Cheong, Hee-Tae;Kim, Choung-Ik;Yang, Boo-Keun
    • Development and Reproduction
    • /
    • v.8 no.2
    • /
    • pp.91-97
    • /
    • 2004
  • The objective of this study was to assess that the effects of DEHP administration on reproductive characteristics and blood hematological and chemical values in pups born after DEHP administration in pregnant mice. DEHP was administrated to pregnant mice by intraperitoneally injection with 0, 0.5, 1.0 and 10.0mg/kg B.W, 5 times at 3 days interval from Day 1 to Day 16 in the gestation period. The body weight and reproductive organ weight(testis, epididymis and coagulating gland) in male pups on 45 day after birth was not affected in all experimental groups, but vesicular gland in DEHP groups was significantly lower than that of control group(P<0.05). The semen characteristics of male pups were not affected in DEHP treatment groups. The WBC, HB, HT, MCH and albumin values in male pups were not affected in all experimental groups, but RBC MCV, MCHC, PLT and total protein values were significantly different among the experimental groups(P<0.05). In female pups, the effects of DEHP administration were not affected the body and uterus weight, but the left ovary in 10.0mg DEHP group was significantly heavier than in control and 0.5mg DEHP group(P<0.05). The WBC, MCV, MCH, MCHC, PLT, albumin, BUN and total protein values in female were not different in all experimental groups. The RBC, HB and HT values were significantly different among the experimental gruop(P<0.05). The historical evaluation of testis in male pups that were grown to 45 days after birth was not different in all experimental groups. The ovary in female pups had many corpus luteum in 10.0mg DEHP group. The endometriosisi of uterus was significantly decreased in DEHP group. There results suggest that low concentration of DEHP administration in pup born after DEHP administration in pregnant mice was not affered on reproductive characteristic, but was affected on blood hematological and chemical values.

  • PDF

Development of processed food database using Korea National Health and Nutrition Examination Survey data (국민건강영양조사 자료를 이용한 가공식품 데이터베이스 구축)

  • Yoon, Mi Ock;Lee, Hyun Sook;Kim, Kirang;Shim, Jae Eun;Hwang, Ji-Yun
    • Journal of Nutrition and Health
    • /
    • v.50 no.5
    • /
    • pp.504-518
    • /
    • 2017
  • Purpose: The objective of this study was to develop a processed foods database (DB) for estimation of processed food intake in the Korean population using data from the Korea National Health and Nutrition Survey (KNHANES). Methods: Analytical values of processed foods were collected from food composition tables of national institutions (Development Institute, Rural Development Administration), the US Department of Agriculture, and previously reported scientific journals. Missing or unavailable values were substituted, calculated, or imputed. The nutrient data covered 14 nutrients, including energy, protein, carbohydrates, fat, calcium, phosphorus, iron, sodium, potassium, vitamin A, thiamin, riboflavin, niacin, and vitamin C. The processed food DB covered a total of 4,858 food items used in the KNHANES. Each analytical value per food item was selected systematically based on the priority criteria of data sources. Results: Level 0 DB was developed based on a list of 8,785 registered processed foods with recipes of ready-to-eat processed foods, one food composition table published by the national institution, and nutrition facts obtained directly from manufacturers or indirectly via web search. Level 1 DB included information of 14 nutrients, and missing or unavailable values were substituted, calculated, or imputed at level 2. Level 3 DB evaluated the newly constructed nutrient DB for processed foods using the 2013 KNHANES. Mean intakes of total food and processed food were 1,551.4 g (males 1,761.8 g, females 1,340.8 g) and 129.4 g (males 169.9 g, females 88.8 g), respectively. Processed foods contributed to nutrient intakes from 5.0% (fiber) to 12.3% (protein) in the Korean population. Conclusion: The newly developed nutrient DB for processed foods contributes to accurate estimation of nutrient intakes in the Korean population. Consistent and regular update and quality control of the DB is needed to obtain accurate estimation of usual intakes using data from the KNHANES.

The Comparison of Knee Joint Displaying between The Anteroposterior Weight Bearing View and the Metatarsophalangeal View with Osteoarthritis Patients (골관절염 환자의 촬영방법에 대한 고찰 : AP-WB(Weight-bearing AP), MTP(semiflexed) 촬영법의 비교 고찰을 중심으로)

  • Jeon, Ju-Seob;Park, Hwan-Sang;Moon, Il-Bong;Moon, Ju-Wan;Choi, Nam-Kil;Kim, Chang-Bok;Eun, Sung-Jong
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Objective : The aim of this study was to compare the knee joint displaying between the anteroposterior weight bearing(AP-WB) View and the metatarsophalangeal(MTP) view for assessing joint space narrowing(JSN) and osteophytes in osteoarthritis patients. Subjects and Materials : Two hundreds of twenty patients(38 men) who came rheumatoid caused by knee pain, had both AP-WB and MTP views taken on a day. Radiographs were evaluated independently by 13 experienced observers(3 orthopedics surgeon, 2 rheumatogist, 3 radiologist, 5 radiological technologist) They assessed JSN and osteophytes using by PACS monitor JSN was scored by the optic evaluation to the nearest at the narrowest point in medial compartments of the tibiofemoral joint in both knees. Osteophytes were graded 0 to 3(bad 0, not bad 1, good 2 and very good 3) according to a standard atlas. All exam was using by Philips(Buckey Diagnostic-TH) X-ray material. Exposure condition was 60 kv, 8 mAs and 100 cm focus to film distance. Results : JSN was scored $1.32{\pm}0.050$ in AP-WB view, $2.51{\pm}0.046$ in MTP view. MTP view of JSN score is higher to AP-WB view significantly(p<0.05). Osteophytes scored $2.14{\pm}0.054$ in AP-WB view, $2.10{\pm}0.054$ in MTP view. There was no difference(p<0.05) between MTP view and AP-WB view in osteophytes. But MTP view was more reproducible than AP-WB view Conclusions : Joint space narrowing is most important factor to diagnosis with knee joint Osteoarthritis patients. This study was summarized as follows; In comparision of JSN, MTP view was more widely displayed than AP-WB view. In comparision of Osteophytes, there was no difference between MTP view and AP-WB view. It was concluded MTP view was more useful method to diagnosis of knee joint Osteoarthritis patients.

  • PDF

Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2 (뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • Acoustic noise during magnetic resonance imaging (MRI) is the main source for patient discomfort. we report our preliminary experience with this technique in neuroimaging with regard to subjective and objective noise levels and image quality. 60 patients(29 males, 31 females, average age of 60.1) underwent routine brain MRI with 3.0 Tesla (MAGNETOM Tim Trio; Siemens, Germany) system and 12-channel head coil. Q-$T_2$ and $T_2$ sequence were performed. Measurement of sound pressure levels (SPL) and heart rate on Q-$T_2$ and $T_2$ was performed respectively. Quantitative analysis was carried out by measuring the SNR, CNR, and SIR values of Q-$T_2$, $T_2$ and a statistical analysis was performed using independent sample T-test. Qualitative analysis was evaluated by the eyes for the overall quality image of Q-$T_2$ and $T_2$. A 5-point evaluation scale was used, including excellent(5), good(4), fair(3), poor(2), and unacceptable(1). The average noise and peak noise decreased by $15dB_A$ and $10dB_A$ on $T_2$ and Q-$T_2$ test. Also, the average value of heartbeat rate was lower in Q-$T_2$ for 120 seconds in each test, but there was no statistical significance. The quantitative analysis showed that there was no significant difference between CNR and SIR, and there was a significant difference (p<0.05) as SNR had a lower average value on Q-$T_2$. According to the qualitative analysis, the overall quality image of 59 case $T_2$ and Q-$T_2$ was evaluated as excellent at 5 points, and 1 case was evaluated as good at 4 points due to a motion artifact. Q-$T_2$ is a promising technique for acoustic noise reduction and improved patient comfort.

Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF