• Title/Summary/Keyword: objective assessment

Search Result 2,673, Processing Time 0.027 seconds

Comparison Between Contrast-Enhanced Computed Tomography and Contrast-Enhanced Magnetic Resonance Imaging With Magnetic Resonance Cholangiopancreatography for Resectability Assessment in Extrahepatic Cholangiocarcinoma

  • Jeongin Yoo;Jeong Min Lee;Hyo-Jin Kang;Jae Seok Bae;Sun Kyung Jeon;Jeong Hee Yoon
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.983-995
    • /
    • 2023
  • Objective: To compare the diagnostic performance and interobserver agreement between contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CE-MRI) with magnetic resonance cholangiopancreatography (MRCP) for evaluating the resectability in patients with extrahepatic cholangiocarcinoma (eCCA). Materials and Methods: This retrospective study included treatment-naïve patients with pathologically confirmed eCCA, who underwent both CECT and CE-MRI with MRCP using extracellular contrast media between January 2015 and December 2020. Among the 214 patients (146 males; mean age ± standard deviation, 68 ± 9 years) included, 121 (56.5%) had perihilar cholangiocarcinoma. R0 resection was achieved in 108 of the 153 (70.6%) patients who underwent curative-intent surgery. Four fellowship-trained radiologists independently reviewed the findings of both CECT and CE-MRI with MRCP to assess the local tumor extent and distant metastasis for determining resectability. The pooled area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of CECT and CE-MRI with MRCP were compared using clinical, surgical, and pathological findings as reference standards. The interobserver agreement of resectability was evaluated using Fleiss kappa (κ). Results: No significant differences were observed between CECT and CE-MRI with MRCP in the pooled AUC (0.753 vs. 0.767), sensitivity (84.7% [366/432] vs. 90.3% [390/432]), and specificity (52.6% [223/424] vs. 51.4% [218/424]) (P > 0.05 for all). The AUC for determining resectability was higher when CECT and CE-MRI with MRCP were reviewed together than when CECT was reviewed alone in patients with discrepancies between the imaging modalities or with indeterminate resectability (0.798 [0.754-0.841] vs. 0.753 [0.697-0.808], P = 0.014). The interobserver agreement for overall resectability was fair for both CECT (κ = 0.323) and CE-MRI with MRCP (κ = 0.320), without a significant difference (P = 0.884). Conclusion: CECT and CE-MRI with MRCP showed no significant differences in the diagnostic performance and interobserver agreement in determining the resectability in patients with eCCA.

Tc-99m DMSA SPECT for Follow-Up of Non-Operative Treatments in Renal Injuries: A Prospective Single-Center Study

  • Sang-Geon Cho;Ki Seong Park;Jahae Kim;Jang Bae Moon;Ho-Chun Song;Taek Won Kang;Seong Hyeon Yu
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1017-1027
    • /
    • 2023
  • Objective: The assessment of cortical integrity following renal injuries with planar Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy depends on measuring relatively decreased cortical uptake (i.e., split renal function [SRF]). We analyzed the additive values of the volumetric and quantitative analyses of the residual cortical integrity using single-photon emission computed tomography (SPECT) compared to the planar scintigraphy. Materials and Methods: This prospective study included 47 patients (male:female, 32:15; age, 47 ± 22 years) who had non-operatively managed renal injuries and underwent DMSA planar and SPECT imaging 3-6 months after the index injury. In addition to planar SRF, SPECT SRF, cortical volume, and absolute cortical uptake were measured for the injured kidney and both kidneys together. The correlations of planar SRF with SPECT SRF and those of SRF with volumetric/quantitative parameters obtained with SPECT were analyzed. The association of SPECT parameters with renal function, grades of renal injuries, and the risk of renal failure was also analyzed. Results: SPECT SRF was significantly lower than planar SRF, with particularly higher biases in severe renal injuries. Planar and SPECT SRF (dichotomized with a cutoff of 45%) showed 19%-36% of discrepancies with volumetric and quantitative DMSA indices (when dichotomized as either high or low). Absolute cortical uptake of the injured kidney best correlated with glomerular filtration rate (GFR) at follow-up (ρ = 0.687, P < 0.001) with significant stepwise decreases by GFR strata (90 and 60 mL/min/1.73 m2). Total renal cortical uptake was significantly lower in patients with moderate-to-high risk of renal failure than those with low risk. However, SRF did not reflect GFR decrease below 60 mL/min/1.73 m2 or the risk of renal failure, regardless of planar or SPECT (count- or volume-based SRF) imaging. Conclusion: Quantitative measurements of renal cortical integrity assessed with DMSA SPECT can provide more clinically relevant and comprehensive information than planar imaging or SRF alone.

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

Quality of Radiomics Research on Brain Metastasis: A Roadmap to Promote Clinical Translation

  • Chae Jung Park;Yae Won Park;Sung Soo Ahn;Dain Kim;Eui Hyun Kim;Seok-Gu Kang;Jong Hee Chang;Se Hoon Kim;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.77-88
    • /
    • 2022
  • Objective: Our study aimed to evaluate the quality of radiomics studies on brain metastases based on the radiomics quality score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) checklist, and the Image Biomarker Standardization Initiative (IBSI) guidelines. Materials and Methods: PubMed MEDLINE, and EMBASE were searched for articles on radiomics for evaluating brain metastases, published until February 2021. Of the 572 articles, 29 relevant original research articles were included and evaluated according to the RQS, TRIPOD checklist, and IBSI guidelines. Results: External validation was performed in only three studies (10.3%). The median RQS was 3.0 (range, -6 to 12), with a low basic adherence rate of 50.0%. The adherence rate was low in comparison to the "gold standard" (10.3%), stating the potential clinical utility (10.3%), performing the cut-off analysis (3.4%), reporting calibration statistics (6.9%), and providing open science and data (3.4%). None of the studies involved test-retest or phantom studies, prospective studies, or cost-effectiveness analyses. The overall rate of adherence to the TRIPOD checklist was 60.3% and low for reporting title (3.4%), blind assessment of outcome (0%), description of the handling of missing data (0%), and presentation of the full prediction model (0%). The majority of studies lacked pre-processing steps, with bias-field correction, isovoxel resampling, skull stripping, and gray-level discretization performed in only six (20.7%), nine (31.0%), four (3.8%), and four (13.8%) studies, respectively. Conclusion: The overall scientific and reporting quality of radiomics studies on brain metastases published during the study period was insufficient. Radiomics studies should adhere to the RQS, TRIPOD, and IBSI guidelines to facilitate the translation of radiomics into the clinical field.

Impact of Collateral Circulation on Futile Endovascular Thrombectomy in Acute Anterior Circulation Ischemic Stroke

  • Yoo Sung Jeon;Hyun Jeong Kim;Hong Gee Roh;Taek-Jun Lee;Jeong Jin Park;Sang Bong Lee;Hyung Jin Lee;Jin Tae Kwak;Ji Sung Lee;Hee Jong Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.31-41
    • /
    • 2024
  • Objective : Collateral circulation is associated with the differential treatment effect of endovascular thrombectomy (EVT) in acute ischemic stroke. We aimed to verify the ability of the collateral map to predict futile EVT in patients with acute anterior circulation ischemic stroke. Methods : This secondary analysis of a prospective observational study included data from participants underwent EVT for acute ischemic stroke due to occlusion of the internal carotid artery and/or the middle cerebral artery within 8 hours of symptom onset. Multiple logistic regression analyses were conducted to identify independent predictors of futile recanalization (modified Rankin scale score at 90 days of 4-6 despite of successful reperfusion). Results : In a total of 214 participants, older age (odds ratio [OR], 2.40; 95% confidence interval [CI], 1.56 to 3.67; p<0.001), higher baseline National Institutes of Health Stroke Scale (NIHSS) scores (OR, 1.12; 95% CI, 1.04 to 1.21; p=0.004), very poor collateral perfusion grade (OR, 35.09; 95% CI, 3.50 to 351.33; p=0.002), longer door-to-puncture time (OR, 1.08; 95% CI, 1.02 to 1.14; p=0.009), and failed reperfusion (OR, 3.73; 95% CI, 1.30 to 10.76; p=0.015) were associated with unfavorable functional outcomes. In 184 participants who achieved successful reperfusion, older age (OR, 2.30; 95% CI, 1.44 to 3.67; p<0.001), higher baseline NIHSS scores (OR, 1.12; 95% CI, 1.03 to 1.22; p=0.006), very poor collateral perfusion grade (OR, 4.96; 95% CI, 1.42 to 17.37; p=0.012), and longer door-to-reperfusion time (OR, 1.09; 95% CI, 1.03 to 1.15; p=0.003) were associated with unfavorable functional outcomes. Conclusion : The assessment of collateral perfusion status using the collateral map can predict futile EVT, which may help select ineligible patients for EVT, thereby potentially reducing the rate of futile EVT.

Physical habitat characteristics of freshwater crayfish Cambaroides similis (Koelbel, 1892) (Arthropoda, Decapoda) in South Korea

  • Jin-Young Kim;Yong Ju Kwon;Ye Ji Kim;Yeong-Deok Han;Jung Soo Han;Chae Hui An;Yong Su Park;Dongsoo Kong
    • Journal of Ecology and Environment
    • /
    • v.47 no.4
    • /
    • pp.200-210
    • /
    • 2023
  • Background: Cambaroides similis is an endangered candidate species living in the stream of South Korea. Freshwater crayfish is known to decline rapidly not only domestically, but also internationally. Its decline is projected to be further exacerbated due to climate change. Understanding physical characteristics of the habitat is crucial for the conservation of an organism. However, comprehensive data regarding the distribution and physical habitat characteristics of C. similis are currently unavailable in South Korea. Thus, the objective of this study was to ascertain preferred ranges for water depth, current velocity, and streambed substrate of C. similis using Weibull model. Results: In this study, C. similis was found at 59 sites across 12 regions in South Korea. Its optimal water depth preferences ranged from 11.9 cm to 30.1 cm. Its current velocity preferences ranged from 9.8 cm s-1 to 29.1 cm s-1. Its substrate preferences ranged from -5.1 𝜱m to -2.5 𝜱m. Median values of central tendency were determined as follows: water depth of 21.4 cm, current velocity of 21.2 cm s-1, and substrate of -4.1 𝜱m. Mean values of central tendency were determined as follows: water depth of 21.8 cm, current velocity of 22.0 cm s-1, and substrate of -4.4 𝜱m. Mode values of central tendency were determined as follows: water depth of 21.7 cm, current velocity of 20.1 cm s-1, and substrate of -3.7 𝜱m. Conclusions: Based on habitat suitability analysis, physical microhabitat characteristics of C. similis within a stream were identified as Run section with coarse particle substrate, low water depth, and slow current velocity. Due to high sensitivity of these habitats to environmental changes, prioritized selection and assessment of threats should be carried out as a primary step.

Assessment of the Severity of Coronavirus Disease: Quantitative Computed Tomography Parameters versus Semiquantitative Visual Score

  • Xi Yin;Xiangde Min;Yan Nan;Zhaoyan Feng;Basen Li;Wei Cai;Xiaoqing Xi;Liang Wang
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.998-1006
    • /
    • 2020
  • Objective: To compare the accuracies of quantitative computed tomography (CT) parameters and semiquantitative visual score in evaluating clinical classification of severity of coronavirus disease (COVID-19). Materials and Methods: We retrospectively enrolled 187 patients with COVID-19 treated at Tongji Hospital of Tongji Medical College from February 15, 2020, to February 29, 2020. Demographic data, imaging characteristics, and clinical data were collected, and based on the clinical classification of severity, patients were divided into groups 1 (mild) and 2 (severe/critical). A semiquantitative visual score was used to estimate the lesion extent. A three-dimensional slicer was used to precisely quantify the volume and CT value of the lung and lesions. Correlation coefficients of the quantitative CT parameters, semiquantitative visual score, and clinical classification were calculated using Spearman's correlation. A receiver operating characteristic curve was used to compare the accuracies of quantitative and semi-quantitative methods. Results: There were 59 patients in group 1 and 128 patients in group 2. The mean age and sex distribution of the two groups were not significantly different. The lesions were primarily located in the subpleural area. Compared to group 1, group 2 had larger values for all volume-dependent parameters (p < 0.001). The percentage of lesions had the strongest correlation with disease severity with a correlation coefficient of 0.495. In comparison, the correlation coefficient of semiquantitative score was 0.349. To classify the severity of COVID-19, area under the curve of the percentage of lesions was the highest (0.807; 95% confidence interval, 0.744-0.861: p < 0.001) and that of the quantitative CT parameters was significantly higher than that of the semiquantitative visual score (p = 0.001). Conclusion: The classification accuracy of quantitative CT parameters was significantly superior to that of semiquantitative visual score in terms of evaluating the severity of COVID-19.

Histological Validation of Cardiovascular Magnetic Resonance T1 Mapping for Assessing the Evolution of Myocardial Injury in Myocardial Infarction: An Experimental Study

  • Lu Zhang;Zhi-gang Yang;Huayan Xu;Meng-xi Yang;Rong Xu;Lin Chen;Ran Sun;Tianyu Miao;Jichun Zhao;Xiaoyue Zhou;Chuan Fu;Yingkun Guo
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1294-1304
    • /
    • 2020
  • Objective: To determine whether T1 mapping could monitor the dynamic changes of injury in myocardial infarction (MI) and be histologically validated. Materials and Methods: In 22 pigs, MI was induced by ligating the left anterior descending artery and they underwent serial cardiovascular magnetic resonance examinations with modified Look-Locker inversion T1 mapping and extracellular volume (ECV) computation in acute (within 24 hours, n = 22), subacute (7 days, n = 13), and chronic (3 months, n = 7) phases of MI. Masson's trichrome staining was performed for histological ECV calculation. Myocardial native T1 and ECV were obtained by region of interest measurement in infarcted, peri-infarct, and remote myocardium. Results: Native T1 and ECV in peri-infarct myocardium differed from remote myocardium in acute (1181 ± 62 ms vs. 1113 ± 64 ms, p = 0.002; 24 ± 4% vs. 19 ± 4%, p = 0.031) and subacute phases (1264 ± 41 ms vs. 1171 ± 56 ms, p < 0.001; 27 ± 4% vs. 22 ± 2%, p = 0.009) but not in chronic phase (1157 ± 57 ms vs. 1120 ± 54 ms, p = 0.934; 23 ± 2% vs. 20 ± 1%, p = 0.109). From acute to chronic MI, infarcted native T1 peaked in subacute phase (1275 ± 63 ms vs. 1637 ± 123 ms vs. 1471 ± 98 ms, p < 0.001), while ECV progressively increased with time (35 ± 7% vs. 46 ± 6% vs. 52 ± 4%, p < 0.001). Native T1 correlated well with histological findings (R2 = 0.65 to 0.89, all p < 0.001) so did ECV (R2 = 0.73 to 0.94, all p < 0.001). Conclusion: T1 mapping allows the quantitative assessment of injury in MI and the noninvasive monitoring of tissue injury evolution, which correlates well with histological findings.

Task-Oriented Approaches to Developmental Coordination Disorder: A Literature Review (발달성협응장애와 과제-중심 접근법(task-oriented approach)에 대한 문헌 고찰)

  • Lee, Seung-Jin;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.22 no.1
    • /
    • pp.69-84
    • /
    • 2024
  • Objective : This study aimed to provide an overview of task-oriented approaches for children with developmental coordination disorder, including its definition, diagnosis, causes, and assessment, through a literature review. Subject : Eighteen international articles published between January 2000 and September 2023 were analyzed to explore the intervention strategies of Neuromotor Task Training (NTT) and Cognitive Orientation to daily Occupational Performance (CO-OP). The objectives of the interventions mentioned in the reviewed articles were categorized according to the criteria of the Occupational Therapy Practice Framework-4 (OTPF-4). The results showed that NTT more frequently set goals in the area of client factors, while CO-OP set goals only in the area of occupation. This difference in goal setting can be explained by the strategy differences between the two interventions. Conclusion : A broader and deeper understanding of strategies for interventions with task-oriented approaches to developmental coordination disorder can increase awareness of the disorder and provide a more solid basis for evidence-based practice.

Development of an Efficiency Calibration Model Optimization Method for Improving In-Situ Gamma-Ray Measurement for Non-Standard NORM Residues (비정형 공정부산물 In-Situ 감마선 측정 정확도 향상을 위한 효율교정 모델 최적화 방법 개발)

  • WooCheol Choi;Tae-Hoon Jeon;Jung-Ho Song;KwangPyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.471-479
    • /
    • 2023
  • In In-situ radioactivity measurement techniques, efficiency calibration models use predefined models to simulate a sample's geometry and radioactivity distribution. However, simplified efficiency calibration models lead to uncertainties in the efficiency curves, which in turn affect the radioactivity concentration results. This study aims to develop an efficiency calibration optimization methodology to improve the accuracy of in-situ gamma radiation measurements for byproducts from industrial facilities. To accomplish the objective, a drive mechanism for rotational measurement of an byproduct simulator and a sample was constructed. Using ISOCS, an efficiency calibration model of the designed object was generated. Then, the sensitivity analysis of the efficiency calibration model was performed, and the efficiency curve of the efficiency calibration model was optimized using the sensitivity analysis results. Finally, the radiation concentration of the simulated subject was estimated, compared, and evaluated with the designed certification value. For the sensitivity assessment of the influencing factors of the efficiency calibration model, the ISOCS Uncertainty Estimator was used for the horizontal and vertical size and density of the measured object. The standard deviation of the measurement efficiency as a function of the longitudinal size and density of the efficiency calibration model decreased with increasing energy region. When using the optimized efficiency calibration model, the measurement efficiency using IUE was improved compared to the measurement efficiency using ISOCS at the energy of 228Ac (911 keV) for the nuclide under analysis. Using the ISOCS efficiency calibration method, the difference between the measured radiation concentration and the design value for each simulated subject measurement direction was 4.1% (1% to 10%) on average. The difference between the estimated radioactivity concentration and the design value was 3.6% (1~8%) on average when using the ISOCS IUE efficiency calibration method, which was closer to the design value than the efficiency calibration method using ISOCS. In other words, the estimated radioactivity concentration using the optimized efficiency curve was similar to the designed radioactivity concentration. The results of this study can be utilized as the main basis for the development of regulatory technologies for the treatment and disposal of waste generated during the operation, maintenance, and facility replacement of domestic byproduct generation facilities.