• Title/Summary/Keyword: nylon filter

Search Result 23, Processing Time 0.024 seconds

Influences of Detention Time, Particle Size Distribution, and Filter Medium on Waterworks Sludges Dewatering (체류시간, 입도분포 및 여재가 정수 슬러지의 탈수에 미치는 영향)

  • Kim, Kwang-Soo;Lee, Jae-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.121-128
    • /
    • 2009
  • Objectives of this study were to investigate influencing factors of detention time, particle size distribution, and filter medium characteristics for waterworks sludge dewatering. The stepped pressure filtration was carried out with lab scale apparatus and the filter press pilot test for dewatering was conducted at the water treatment plant. Effects of filter medium and polymer dose were examined through observing water content and dewatering velocity and cyclic dewatering rate with filter press pilot test. Relationships among detention time, particle size distribution and filtration resistance were analyzed. Prolongation of sludge detention time was found to cause blinding phenomenon in cake and filter medium and to decrease dewatering process efficiency. The average specific resistance increased according to detention time. In pilot test of dewatering for thickened sludge with Nylon Multi-NY840D and Nylon Mono-100% filter media, dewatering velocities were 0.92 and $0.93kg\;DS/m^2{\cdot}hr$ according to 0.1% polymer dose of dried solids weight base. And cyclic dewatering rates were 2.45 and $2.50kg\;DS/m^2{\cdot}cycle$ cycle for the Nylon Multi-NY840D and Nylon Mono-100% media. Dewatering velocity of polymer dosed sludge was observed to be higher than that of non-polymer sludge.

A Study on the Volatilization of Particulate Nitrate (NO3-) During Fine Particle (PM2.5) Measurement (미세입자(PM2.5) 측정시 발생되는 질산염(NO3-) 휘발에 관한 연구)

  • 강병욱;이학성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.297-303
    • /
    • 2002
  • Fine particles (d$_{p}$ < 2.5 $\mu$m) were measured using an annular denuder system (ADS) in Chongju. The data set was collected on fifty-eight different days with a 24-hr sampling period from October 27, 1995 through August 25, 1996. Particulate nitrate in the ADS was also measured on teflon and nylon filters in series behind denuders to collect HNO$_3$, HNO$_2$, SO$_2$and NH$_3$. From this study. the mean concentration of particulate nitrate of PM$_{2.5}$ in the ADS were seen with the following order: winter (5.05) >fall (4.36) >spring (3.92) > summer (1.10 $\mu\textrm{g}$/㎥). Nitrate losses, which calculated from the ratio of nylon filter nitrate to the sum of teflon and nylon filter nitrates, varied in the following manner summer (72.2%) > spring (42.6%) > fall (23.5%)> winter (0.4%). Especially, gaseous nitric acid was dominant at temperature higher than 8$^{\circ}C$ while particulate nitrate was major species in total nitrate below that temperature. This indicates the particulate nitrate loss is strongly correlated rather with ambient temperature.e.e.

Characteristics of water quality and extra-cellular polymeric substances in trickling filter system using plastic fiber media (끈상여재를 이용한 Trickling Filter 반응조에서의 EPS 반응특성)

  • Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.169-174
    • /
    • 2008
  • In this study a trickling filter system was developed by using polypropylene media and polypropylene nylon media that has recently been developed. The experiment analyzed an ability of water purification of the two plastic media and the effects of biomass on the final effluent. As recycling ratio increases, polypropylene nylon suspender showed higher efficiency by 20%; and, when media height was lengthened twice, efficiency increased about 10%. EPS and biomass increased in proportion to the increase of recycling ratio, and bound-TOC showed a similar trend with bound-EPS (extra-cellular polymeric substances) concentration.

Characteristics of Nitrate (NO3-) Volatilization from Fine Particles (PM2.5) at 4 Measurement Sites in Seoul (미세입자(PM2.5)의 질산염 (NO3-) 휘발 특성 분석 -서울시 4개 측정지역을 중심으로-)

  • Kim, Yoo-Jung;Jung, Sung-Woon;Kang, Choong-Min;Ma, Young-Il;Kim, Su-Hyang;Woo, Jung-Hun;SunWoo, Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.613-621
    • /
    • 2008
  • The purpose of this study is to understand the impact that temperature and relative humidity have on the volatilization loss of particulate nitrate $(NO_3^-)$ from Teflon filters during measurements of ambient fine particles $(PM_{2.5})$. Fine particles $(d_p<2.5{\mu}m)$ were measured using an annular denuder system (ADS) at four representive areas in Seoul. The measurements were made during 28 different days at 24-hr sampling intervals from February 14 to October 15, 1997. In this study, nitrate losses. calculated by the ratio of nitrate on the nylon filter to their sum in both Teflon and nylon titters, varied seasonally in the following order: summer (45.5%) > spring (23.8%) > fall (20.6%) > winter (19.7%). The results showed strong correlations with temperature, but we did not observe any significant effects of relative humidity. However, we observed that both temperature and relative humidity influenced the ambient gas/particle nitrate ratio in a different case study using a denuder.

Optimal filter materials for protist quantification via droplet digital PCR

  • Juhee Min;Kwang Young Kim
    • ALGAE
    • /
    • v.39 no.1
    • /
    • pp.51-56
    • /
    • 2024
  • The use of droplet digital polymerase chain reaction (ddPCR) has greatly improved the quantification of harmful protists, outperforming traditional methods like quantitative PCR. Notably, ddPCR provides enhanced consistency and reproducibility at it resists PCR inhibitors commonly found in environmental DNA samples. This study aimed to determine the most effective filter material for ddPCR protocols by assessing the reproducibility of species-specific gene copy numbers and filtration time across six filter types: cellulose acetate (CA), mixed cellulose ester (MCE), nylon (NY), polycarbonate (PC), polyethersulfone (PES), and polyvinylidene fluoride (PVDF). The study used two species of Chattonella marina complexes as a case study. Filtration rates were slower for NY, PC, and PVDF filters. Moreover, MCE, NY, PES, and PVDF yielded lower DNA amounts than other filters. Importantly, the CA filter exhibited the lowest variance (38-39%) and the highest determination coefficients (R2 = 0.92-0.96), indicating superior performance. These findings suggest that the CA filter is the most suitable for ddPCR quantification of marine protists, offering quick filtration and reliable reproducibility.

A Study on the Formation of Nitrate in the Atmosphere (환경 대기중 Nitrate의 생성에 관한 연구)

  • 천만영;강공언;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.68-73
    • /
    • 1992
  • A study on the formation of particulate nitrate$(NO_3^-)$ and gaseous nitrate$(HNO_3)$ in the atmosphere was carried out in Seoul from Oct 8 to 11 1991. To collect $NO_3^-$ and $HNO_3$ in the ambient air, dual filter pack sampler (47mm$\phi$) was used. In the dual filter pack sampler, the first filter was Teflon filter (poresize 1$\mum$) for collection of $NO_3^-$ and the second filter was Nylon filter (poresize 0.45 $\mum$) for $HNO_3$. Particulate nitrate$(NO_3^-)$ and Sulfate ions were analysed by Ion chromatography. $HNO_3$ concentration was higher in the day time $(9.93\mug/m^3)$ than the night time$(3.50\mug/m^3)$, and Particulate nitrate$(NO_3^-)$ concentration was higher in the night time and early morning$(6.21\mug/m^3)$ than the day time$(4.31\mug/m^3)$. The conversion rate of $NO_x$ to total nitrate$(NO_3^-, HNO_3)$ was 7.57%/hr in the day time and 4.79%/hr in the night time, and total average conversion rate was 5.60%/hr.

  • PDF

The Effects of Varying Sampling Flow Rates on the Measurements of Total Nitrate and Sulfate in Dry Acid Deposition

  • Park, Jong-Kil;Kim, Jo-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E1
    • /
    • pp.1-12
    • /
    • 2002
  • One technique for determining dry acid deposition fluxes involves measurement of time - averaged ambient concentrations of dry acid deposition species using filter packs (FP) coupled with estimates of mean deposition velocities for the exposure period. A critical problem associated with filter pack data comparisons between various field sampling networks is the use of diverse sampling flow rates and duration protocols. Field experiments were conducted to evaluate the effects of varying sampling flow rates, from 1.5 to 10 standard liters per minute, on total nitrate and sulfate measurements of specific dry acid deposition species . Collocated FP samplers were used to determine sampling and analysis data reproducibility and representativeness . Ambient air samples were simultaneously collected using groups of filter packs operated at various flow rates over identical 7 day periods. The species measured were sulfur dioxide, particulate sulfate , nitric acid and particulate nitrate. Statistical results (ANOVA; alpha level 5%) showed that neither the low nor high sampling flow rates caused a significant difference in the measurements of total sulfate and adjusted total nitrate (ATN) . However, it was concluded that for high flow rate sampling measurements, total nitrate (TN) could be affected during extended sampling durations because of potential nitric acid overloading and breakthrough. Although the previous workers (Costello, 1990; Quillian, 1990) used much higher sampling flow rates (~ 17 sLpm) than employed here, it was assumed that for a high loading (> 50$\mu\textrm{g}$ HNO$_3$) of nitric acid on the Nylon filters, a significant fraction (~10%) of nitric acid could pass through the Nylon filters and be collected on the carbonate impregnated filters. It was concluded that even at the highest sampling flow rate employed (10 sLpm) at the Cary Forest site, nitric acid breakthrough was less than 10% of the total HNO$_3$ collected. However, for a heavily polluted urban airshed or with longer sampling times , higher filter loadings could result in substantial nitric acid breakthrough and HNO$_3$concentrations would be underestimated.

A New Analytical Method for the $Eu^{+3}$ and $Tb^{+3}$ Ions Using the Luminescence Enhancement by the Treatment of o-Phenanthroline on the Nylon Membrane (Nylon Membrane Filter에서의 발광증폭을 이용한 $Eu^{+3}$$Tb^{+3}$ 이온의 극미량 분석법)

  • An, Seong-Hee;Lee, Byung-Min;Park, Jong-Mok;Kim, Hai-Dong;Jeong, Hyuk
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.9
    • /
    • pp.705-714
    • /
    • 1995
  • A new analytical luminescence method for the Eu+3 and Tb+3 ions was studied using the luminescence enhancement by the treatment of the o-phenanthroline on the nylon membrane. Compared to the specific emission intensities of the ions in aqueous(or ethanol) solution, if the aqueous ion is spotted on the nylon membrane, the luminescence intensities were extremely enhanced. There was additional enhancement effect of the luminescence intensities of the ions on the nylon membrane, if the ion on the nylon membrane is treated with o-phenanthroline. Based on the luminescence enhancement, the detection limits were lowered by more than 7 order of magnitude compared to that of solution sample, and also lowered by about 1 order of magnitude compared to that of previous TLC method. The dynamic ranges and correlation coefficients of the calibration curves near the detection limit were 2∼3 order and ∼0.99, respectively. It was also shown that the luminescence intensity was in its maximum when the ion on the nylon is treated with ∼4 mole ratio of o-phenanthroline. The energy-transfer mechanism was explained for the theoretical background of the luminescence enhancement.

  • PDF

Filtration Performance of Fibrous Air Filter under External Electric Field using Insulated Electrodes (외부전기장 적용 섬유상 에어필터의 절연 전극 사용에 따른 여과특성)

  • Ji, Sung-Mi;Sohn, Jong-Ryeul;Park, Hyun-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.675-687
    • /
    • 2012
  • Applying an external electric field across air filter media is one of methods to improve the filtration performance. Metal wire meshes have been commonly used as electrodes situated on both sides of a thick filter pad. For a thin filter medium a short circuit, known as the biggest drawback for applying an external electric field to air filter, can occur at the closest point between electrodes. In this study several types of insulated meshes were prepared by coating #50 meshes with a dielectric material, Nylon 66, and the filtration property of air filter was evaluated at the presence of external electric field using those insulated meshes as electrodes and compared with that of filters using bared meshes. The collection efficiency of tested filter was increased from 78% to 95% for singly charged 100 nm particles by application of external electric field. As a result, there was no significant difference in collection efficiency between filters with insulated and bared electrodes. Similar results could be also seen from the tests using polydisperse particles. Finally, through this study, we found that the insulation of mesh electrodes doesn't affect the filtration performance of fibrous air filter under external electric field.

Aerosol filtration and electrostatic properties of electrospun nanofiber air filters (전기방사 나노섬유 에어필터의 정전기적 특성 및 에어로졸 여과특성)

  • Park, Hyun-Seol;Lim, Koung Soo
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.71-81
    • /
    • 2009
  • In this study, Nylon 6,6 electrospun (ES) nanofiber filter media were prepared at various spinning conditions. The ES filters tested had no intrinsic electrical charges. The ES filters were triboelectrically charged in the course of filter sample handling, and the charge was drastically decayed in a few hours. On the other hand, the corona charged melt blown filter media showed a permanent electrical charge. The electrical charge state of the ES filters was also examined by comparing collection efficiencies of ES filters for uncharged and charged aerosol particles.

  • PDF