• Title/Summary/Keyword: numerical protection

Search Result 390, Processing Time 0.034 seconds

The Study on the Combat Placement Availability of the Reinforce Concrete Box-type Artillery Positions (철근콘크리트조 박스형 포상의 전력화 가능성에 관한 연구)

  • Baek, Jonghyuk;Kim, Sukbong;Park, Young Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.88-89
    • /
    • 2013
  • For the purpose of launching strikes, initial survivability of self-propelled artilleries is of crucial importance despite the fact that they are mobility weapon systems. This study identifies the combat placement possibility of the reinforced concrete box-type artillery positions, which might enable the replacement of the current igloo-types, in terms of cost and protection capability. In the numerical analysis the obtained numerical values have proved that these facilities have sufficient protection capability. In addition, it could be concluded that these facilities are also cost-competitive, if more than five positions are constructed simultaneously.

  • PDF

Design of A Downlink Power Control Scheme in Unequal Error Protection Multi-Code CDMA Mobile Medicine System

  • Lin, Chin-Feng;Lee, Hsin-Wang;Hung, Shih-Ii;Li, Ching-Yi
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.335-338
    • /
    • 2005
  • In this paper, we propose a downlink power control scheme to apply in the unequal error protection multi-code CDMA mobile medicine system. The mobile medicine system contains (i) blood pressure and body temperature measurement value, (ii) ECG medical signals measured by the electrocardiogram device, (iii) mobile patient's history, (iv) G.729 audio signal, MPEG-4 CCD sensor video signal, and JPEG2000 medical image. By the help of the multi-code CDMA spread spectrum communication system with downlink power control scheme and unequal error protection strategy, it is possible to transmit mobile medicine media and meet the quality of service. Numerical analysis and simulation results show that the system is a well transmission platform in mobile medicine.

  • PDF

Optimum Location of Electrode of Cathodic Protection System by using Boundary Element Method (BEM을 이용한 Cathode 방식 시스템에서 전극 위치 최적화)

  • Lee, Kwang-Ho;Chung, Koon-Seok;Baik, Dong-Chul;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.772-774
    • /
    • 2000
  • The objective of a cathodic protection system (CP) is to protect the buried metallic structure against the corrosion caused by chemical reaction between the buried structure and the surrounding medium, such as soil. This paper presents a boundary element application to determine the optimal impressed current densities in a cathodic protection system. The potential within the electrolyte is described by the Laplace's equation with nonlinear boundary conditions which are enforced based on experimentally determined electrochemical polarization curves. The optimal impressed current densities are determined in order to minimize the power supply for protection. The solution is obtained by using the conjugate gradient method in which the governing equations and the protecting conditions are taken into account by the penalty function method. Numerical example are presented to demonstrate the practical applicability of the proposed method.

  • PDF

Numerical Investigation on Fire of Stage in Theater: Effects of Natural Smoke Vent Area and Fire Source Location (공연장 무대부 화재에 대한 전산해석 연구: 자연 배연구 면적과 화원 위치 영향)

  • Park, Min Yeong;Lee, Chi Young
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • This numerical study investigates the effects of the size of the natural smoke vent area (10% and 1% of the floor area) and the location of the fire source (i.e., at the side and center of the stage) on the temperature distribution in the compartment and velocity distribution and mass flow rate of flow through a natural smoke vent for a reduced-scale model of a theater stage. Then, the mass flow rate of outflow through the natural smoke vent in the event of a fire for a real-scale theater stage was examined. The case with the larger natural smoke vent area and central fire source location showed lower temperature distributions and higher mass flow rates of outflow and inflow than the case with the smaller natural smoke vent area and side fire source location. The trends of the temperature distributions were closely related to those of the mass flow rates for the outflow and inflow. Additionally, the case with the larger natural smoke vent area and central fire source location exhibited the most non-uniform flow velocity distribution in all cases tested. A bidirectional flow, in which the outflow and inflow occur simultaneously, was observed through the natural smoke vent. In the event of a fire situation in a real-scale theater stage, it was predicted that the case with the larger natural smoke vent area and central fire source location would have a mass flow rate of outflow that is 43.53 times higher than that of the case with the smaller natural smoke vent area and side fire source location. The present results indicate that the natural smoke vent location should be determined by considering the location in a theater stage where a fire can occur.

Behavior of Geotextile Tube by Plane Strain Analysis and 3-Dimensional Finite Element Method (평면변형해석과 3-D FEM 기법을 통한 지오텍스타일 튜브의 거동해석)

  • 신은철;오영인
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.233-241
    • /
    • 2003
  • Geotextile tube is hydraulically filled with dredged materials and has been applied to coastal protection and scour protection, dewatering method of slurry, and isolation of contaminated material. Recently, geotextile tube technology is no longer alternative construction technique but suitable desired solution. In this paper, the numerical analysis was performed to investigate the behavior of geotextile tube with various properties of geotextile sheet and hydraulic pumping conditions. Numerical analysis was executed to compare with the results from the large-scale field model tests, and also with those of plane strain analysis and 3-D FEM analysis. A geotextile tube was modeled using the commercial finite element analysis program ABAQUS and the one-quarter of tube was modeled. Behavior of geotextile tube during the hydraulic pumping procedure was analyzed by comparing the large-scale field model test and numerical analysis. The shape variation and maximum tube height between the numerical analysis results and large-scale filed test results are turned out to be in a good agreement.

An Analysis Results of Agricultural Ultrasonic Twin-fluid Nozzle (농업용 액체 분무용 초음파 분사 시스템 해석)

  • Chung, Jin-Do
    • Journal of ILASS-Korea
    • /
    • v.8 no.3
    • /
    • pp.1-9
    • /
    • 2003
  • The objective of this study is to compare atomization characteristics for differently made an ultrasonic twin-fluid nozzle. A spray system, an ultrasonic system, and three different type(Nozzle type, Tube type. Conventional type)are made and compared experimental and numerical results. In this investigation, the measurement and numerical analysis of spray droplet are to analyze the effects of ultrasonic energy on the agricultural atomization spray system in order to protection of dispersion droplets. It is clarified that ultrasonic energy forcing into a nozzle is valid to obtain atomization enchancement. As the result of comparing the experimental and numerical result, it is confirmed that nozzle type is highest efficiency than that of tube type and conventional type, also well fit, respectively.

  • PDF

Numerical formulation of P-I diagrams for blast damage prediction and safety assessment of RC panels

  • Mussa, Mohamed H.;Mutalib, Azrul A.;Hao, Hong
    • Structural Engineering and Mechanics
    • /
    • v.75 no.5
    • /
    • pp.607-620
    • /
    • 2020
  • A numerical study is carried out to assess the dynamic response and damage level of one- and two-way reinforced concrete (RC) panels subjected to explosive loads by using finite element LS-DYNA software. The precision of the numerical models is validated with the previous experimental test. The calibrated models are used to conduct a series of parametric studies to evaluate the effects of panel wall dimensions, concrete strength, and steel reinforcement ratio on the blast-resistant capacity of the panel under various magnitudes of blast load. The results are used to develop pressure-impulse (P-I) diagrams corresponding to the damage levels defined according to UFC-3-340-02 manual. Empirical equations are proposed to easily construct the P-I diagrams of RC panels that can be efficiently used to assess its safety level against blast loads.

Invention and Hydraulic Model Test of Combined Block System in River Bank Protection (일체형 하천호안블럭의 개발 및 모형실험 적용)

  • Jang, Suk-Hwan;Lee, Chang-Hae;Park, Sang-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.449-453
    • /
    • 2008
  • This research focused on analyzing and comparing between the results of hydraulic physical modeling and the results of numerical modeling of Grass Concrete which is newly developed in-situ block system. The physical model was built as a scale of 1:50 by Froude similitude measuring the water levels and the water velocities for before and after vegetation and the effects were analyzed after reviewing the results. In consequence, the water velocities were observed to decrease meanly 19.1%, and the water depth were determined to increase meanly 27.8% in case of the of design flood, $Q=200m^3/sec$. Moreover, the velocities were produced reduction effects of 27.2%, and the water levels were derived from addition effects of the highest 31.3% in case of the probability maximum flood(PMF), $Q=600m^3/sec$. To verifying the hydraulic physical modeling, the numerical modeling was conducted for a close examination of before and after vegetation. HEC-RAS model was for 1 dimensional numerical analysis and RMA-2 was for 2 dimensional numerical analysis. The results of the numerical simulation, under the condition of roughness coefficient calibration, shows similar results of the physical modeling. These satisfactory results show that the accomplished results of hydraulic modeling and the predicted results of numerical modeling corresponded reasonably each others.

  • PDF

The effect of vegetation parameter characteristics of the multi-layer vegetation model on wind for numerical simulation of micro-meteorology (미기상 수치모의를 위한 다층식생모델의 식생 팍라메타가 바람에 미치는 영향)

  • 오은주;이화운;정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.6
    • /
    • pp.605-613
    • /
    • 2003
  • In order to make use of the protection effect against wind by the vegetation, it examined whether it should make what vegetation form and arrangement using the 2-dimensional non-hydrostatic model. When the foliage shielding factor increases, it becomes hard to take in protection effect against wind in a residential section. When it makes height of vegetation high, it becomes hard to take in protection effect against wind with height. In the comparison in the case where vegetation high is gradually made low toward wind-stream from a vegetation, and the case of making it low gradually, although former tends to receive the protection effect against wind by the vegetation, attenuation of wind velicity becomes large. In the comparison in the case where foliage shielding factor and distribution of density of leaf are gathered gradually toward wind-stream from a vegetation. It has been understood to evaluate to height the influence that the vegetation multi-layer model by which the heat revenue and expenditure in the direction of the vegetation height is considered is used, and to characterize the vegetation group by the parameter setting.