• Title/Summary/Keyword: numerical evaluation

Search Result 2,636, Processing Time 0.032 seconds

Analysis and structural behavior of shield tunnel lining segment (쉴드터널 라이닝 세그멘트의 해석과 거동 특성)

  • Jung, Du-Hwoe;Lee, Hwan-Woo;Kim, Gwan-Soo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.1
    • /
    • pp.37-47
    • /
    • 2007
  • The shield tunneling method has been increasingly employed to minimize environmental damages and civil complaints in the populated and developed area. A lining segment, which is a main structure of the shield tunnel, consists of joints. Conventional foreign and domestic design data have been commonly used for design practices without a specific verification of structural analysis models, design load, and the effect of soil characteristics on the performance of lining segment. In this study, the suitability of existing analytic models used for the design of shield tunnel lining segment has been evaluated through a comparison between analytical and numerical solutions. Based on the evaluation of their suitability performed in the study, a full-circumferential beam jointed spring model (1R-S0) is proposed for design practices by considering user's convenience, the applicability of field conditions and the accuracy of analysis result. By using the proposed model, the parameter analysis was performed to investigate the effects of joint stiffness, ground rigidity, joint distribution and the number of joints on the behavior of lining segment. Parameters considered in the investigation have been appeared to affect the behavior of lining segment. Among those parameters, joint stiffness has been appeared to have the most significant effect on the bending moment and displacement of lining segment.

  • PDF

Development of Uneven Excavation Method for Reinforcement of Ground Slope (사면보강을 위한 요철형 암반굴착 공법개발)

  • Kim, Hyun-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.259-266
    • /
    • 2020
  • In this study, required drill bits and excavation methods were developed for an uneven drilling method that can solve the problem of performance degradation of rock bolts. The developed drill bit's excavation performance was verified using rock with a strength of 100 MPa or more. In addition, for the relative evaluation of the uneven excavation method, experimental specimens were prepared for models with and without irregularities, and tests were performed. As a result of the experiment, the model with unevenness exhibited an average critical draw resistance of 801.6 kN, which is about 1.7 times the value of 468.7 kN for the model without unevenness, thus confirming the effect sufficiently. Therefore, it is expected that the resistance performance will significantly increase despite an increase in the uneven hole diameter of 20 mm. In the future, the results of this study could be used as basic data when performing other studies using numerical analysis models and performance verification through experiments to obtain an optimized rock forming method.

Numerical Study of Turbulent Heat Transfer in Helically Coiled Tubes (나선형 튜브내의 난류 열전달에 대한 수치적 연구)

  • Yoon, Dong-Hyeog;Park, Ju-Yeop;Seul, Kwang-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.783-789
    • /
    • 2012
  • In this study, turbulent flow and heat transfer characteristics in a helically coiled tube have been numerically investigated. Helically coiled tubes are commonly used in heat exchange systems to enhance the heat transfer rate. Accordingly, they have been widely studied experimentally; however, most studies have focused on the pressure drop and heat transfer correlations. The centrifugal force caused by a helical tube increases the wall shear stress and heat transfer rate on the outer side of the helical tube while decreasing those on the inner side of the tube. Therefore, this study quantitatively shows the variation of the local Nusselt number and friction factor along the circumference at the wall of a helical tube by varying the coil diameter and Reynolds number. It is seen that the local heat transfer rate and wall shear stress greatly decrease near the inner side of the tube, which can affect the safety of the tube materials. Moreover, this study verifies the previous experimental correlations for the friction factor and Nusselt number, and it shows that the correlation between the two in a straight tube can be applied to a helical tube. It is expected that the results of this study can be used as important data for the safety evaluation of heat exchangers and steam generators.

Development of Pedestrian Delay Model at Signalized Intersections (신호교차로 보행자 지체모형 개발)

  • Chang, Hyun-ho;Yoon, Byoung-jo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.283-294
    • /
    • 2018
  • An accurate pedestrian-delay model is essential for the pedestrian-oriented evaluation of signalized intersection (SI). The crossing behaviors of pedestrians at signalized pedestrian crosswalks (SPCs) are various, and their arrival behaviors consist of two types, random and platoon. It is natural, hence, that the behaviors of pedestrian crossing and arrival should be considered in order to estimate accurate pedestrian delay. Despite this necessity, a simple pedestrian-delay model that cannot explain these behaviors of pedestrian movements is still recommended in Highway Capacity Manual (HCM). For these reasons, a pedestrian-delay model, suitable for various SPCs and SIs, is required to make pedestrian-oriented decisions on the design and operation of various SPCs and SIs. This paper proposes a novel pedestrian-delay model that is based on the behaviors of pedestrian crossing and arrival. The proposed model consists of two sub models: the one for SPC and the other for SI. The SPC delay model was developed based on the behaviors of pedestrian crossing during pedestrian green time. The SI delay model was designed based on the behaviors of pedestrian crossing and platoon arrival. The results of a numerical simulation showed that the proposed delay model can successfully overcome the under- and overestimation problems of the HCM model with explaining various behaviors of pedestrian crossing and arrival.

Analysis of Impact on the Circulating Water System due to an Installation of Helical Current Turbine at the Discharge Channel of the Power Plant (헬리컬 조류수차 설치로 인한 발전소 배수로 계통 영향 분석)

  • Kim, Ji-Young;Kang, Keum-Seok;Ryu, Moo-Sung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.2
    • /
    • pp.67-72
    • /
    • 2010
  • In this study, the impact on the circulating water system has been analyzed due to an installation of helical turbine to develop hydro-kinetic energy at the discharge channel of the power plant. Numerical simulations of velocity and pressure variations have been performed when one set of $3.6\;m\;{\times}\;1.5\;m$ sized helical turbine is installed at the outlet of discharge culvert. In case of mean sea level, change of downstream water surface elevation does not affect upstream elevation of the weir because its propagation is blocked by the seal well weir. However in case of highest high water level, change of downstream elevation affects upstream elevation because flow pattern in discharge culvert becomes the full pipe flow with submerged weir. Although an unstable pressure change occurs in upstream of the weir during the intial 10 minutes after beginning of the discharge, it becomes stable after that time. In addition, a rise of water surface elevation by 0.2 m is observed but it is concluded that it hardly affects the safety of circulating water pump (CWP) although its required power is increased more or less. Therefore, the increase of required power of CWP needs to be considered for evaluation of the helical turbine applicability.

A High-resolution Numerical Simulation and Evaluation of Oak Pollen Dispersion Using the CMAQ-pollen Model (CMAQ-pollen 모델을 이용한 참나무 꽃가루 확산 고해상도 수치모의 및 검증)

  • Oh, Inbo;Kim, Kyu Rang;Bang, Jin-Hee;Lim, Yun-Kyu;Cho, Changbum;Oh, Jae-Won;Kim, Yangho;Hwang, Mi-Kyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.1
    • /
    • pp.31-44
    • /
    • 2017
  • The aim of this study is to evaluate the accuracy and variability of the oak pollen concentrations over the Seoul metropolitan region (SMR) simulated by the Community Multiscale Air Quality (CMAQ)-based pollen dispersion model, which is the CMAQ-pollen model integrated with the improved oak pollen emission model(PEM-oak). The PEM-oak model developed is based on hourly emission flux parameterization that includes the effects of plant-specific release, meteorological adjustment, and diurnal variations of oak pollen concentrations. A 33 day-run for oak pollen simulation was conducted by the CMAQ-pollen model with a 3 km spatial resolution for the SMR during the 2014 spring pollen season. Modeled concentrations were evaluated against the hourly measurements at three Burkard sampling sites. Temporal variations of oak concentrations were largely well represented by the model, but the quantitative difference between simulations and measurements was found to be significant in some periods. The model results also showed that large variations in oak pollen concentrations existed in time and space and high concentrations in the SMR were closely associated with the regional transport under strong wind condition. This study showed the effective application of the CMAQ-pollen modeling system to simulate oak pollen concentration in the SMR. Our results could be helpful in providing information on allergenic pollen exposure. Further efforts are needed to further understand the oak pollen release characteristics such as interannual variation of the oak pollen productivity and its spatio-temporal flowering timing.

A Practical standard Air Flow Generator System to Calibrate and Compare Performance of Two Different Respiratory Air Flow Measurement Modules (호흡기류 계측모듈의 교정과 성능 비교를 위한 실용적인 표준기류 생성 시스템)

  • Lee, In-Kwang;Park, Mi-Jung;Lee, Sang-Bong;Kim, Kyoung-Ok;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.115-122
    • /
    • 2015
  • A standard air flow generator system was developed to generate air flows of various levels simultaneously applied to two different air flow transducer modules. Axes of two identical standard syringes for spirometer calibration were connected with each other and driven by a servo-motor. Linear displacement transducer was also connected to the syringe axis to accurately acquire the volume change signal. The user can select either sinusoidal or square waveform of volume change and manually input any volume as well as maximal flow rate levels ranging 0~3 l and 0~15 l/s, respectively. Various volume and flow levels were input to operate the system, then the volume signal was acquired followed by numerical differentiation to obtain the air flow signal. The measured volumes and maximal air flow rates were compared with the user input data. The relative errors between the user-input and the measured stroke volumes were all within 0.5%, demonstrating very accurate driving of the system. In case of the maximal flow rate, relatively large error was observed when the syringe was driven very fast within a very short time duration. However, except for these few data, most measured flow rates revealed relative errors of approximately 2%. When the measure and user-input stroke volume and maximal flow rate data were analyzed by linear regression analysis, respectively, the correlation coefficients were satisfactorily higher than 0.99 (p < 0.0001). These results demonstrate that the servo-motor controls the syringes with enough accuracy to generate standard air flows. Therefore, the present system would be very much practical for calibration process as well as performance evaluation and comparison of two different air flow transducer modules.

A Study on Optimum Ventilation System in the Deep Coal Mine (심부 석탄광산의 환기시스템 최적화 연구)

  • Kwon, Joon Uk;Kim, Sun Myung;Kim, Yun Kwang;Jang, Yun Ho
    • Tunnel and Underground Space
    • /
    • v.25 no.2
    • /
    • pp.186-198
    • /
    • 2015
  • This paper aims for the ultimate goal to optimize the work place environment through assuring the optimal required ventilation rate based on the analysis of the airflow. The working environment is deteriorated due to a rise in temperature of a coal mine caused by increase of its depth and carriage tunnels. To improve the environment, the ventilation evaluation on J coal mine is carried out and the effect of a length of the tunnel on the temperature to enhance the ventilation efficiency in the subsurface is numerically analyzed. The analysis shows that J coal mine needs $17,831m^3/min$ for in-flow ventilation rate but the total input air flowrate is $16,474m^3/min$, $1,357m^3/min$ of in-flow ventilation rate shortage. The temperatures were predicted on the two developed models of J mine, and VnetPC that is a numerical program for the flowrate prediction. The result of the simulation notices the temperature in the case of developing all 4 areas of -425ML as a first model is predicted 29.30 at the main gangway 9X of C section and in the case of developing 3 areas of -425ML excepting A area as a second model, it is predicted 27.45 Celsius degrees.

A Study on Mine Ventilation Network (광산 통기 네트워크 연구)

  • Kim, Soo Hong;Kim, Yun Kwang;Kim, Sun Myung;Jang, Yun Ho
    • Tunnel and Underground Space
    • /
    • v.27 no.4
    • /
    • pp.217-229
    • /
    • 2017
  • This study focuses on the improvement of the working environment in domestic collieries where temperature is increasing due to heat of the earth that is caused by the long-term mining. In order to improve the working environment of the mine, a ventilation evaluation was carried out for Hwasoon Mining Industry. In order to increase the ventilation efficiency of the mine, numerical analysis of the effect on temperature was carried out by using climsim, a temperature prediction program. The analysis shows that A coal mine needs $6,152m^3/min$ for in-flow ventilation rate but the total input air flowrate is $4,710m^3/min$, $1,442m^3/min$ of in-flow ventilation rate shortage. The 93 m hypothetical ventilation shaft from -395 ML to -488 ML could result about $3^{\circ}C$ temperature drop in the coal mine of -488 ML far. As a result of predicting the $CO_2$ concentration at -523 ML development using artificial neural network, the emission of $CO_2$ increased as the amount of coal and coal bed thickness increased. The factors that have the greatest effect on the amount of $CO_2$ emissions were coal layer thickness and coal mining. And, as the air quantity increases, it has a great effect on the decrease of carbon dioxide concentration.

Assessment of the Habitability for a Cabinet Fire in the Main Control Room of Nuclear Power Plant using Sensitivity Analysis (민감도 분석을 이용한 원전 주제어실의 케비닛 화재에 대한 거주성 평가)

  • Han, Ho-Sik;Lee, Jae-Ou;Hwang, Cheol-Hong;Kim, Joosung;Lee, Sangkyu
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.52-60
    • /
    • 2017
  • Numerical simulations were performed to evaluate the habitability of an operator for a cabinet fire in the main control room of a nuclear power plant presented in NUREG-1934. To this end, a Fire Dynamics Simulator (FDS), as a representative fire model, was used. As the criteria for determining the habitability of operator, toxic products, such as CO, were also considered, as well as radiative heat flux, upper layer temperature, smoke layer height, and optical density of smoke. As a result, the probabilities of exceeding the criteria for habitability were evaluated through the sensitivity analysis of the major input parameters and the uncertainty analysis of fire model for various fire scenarios, based on V&V (Verification and Validation). Sensitivity analyses of the maximum heat release rate, CO and soot yields, showed that the habitable time and the limit criterion, which determined the habitability, could be changed. The present methodology will be a realistic alternative to enhancing the reliability for a habitability evaluation in the main control room using uncertain information of cabinet fires.