• Title/Summary/Keyword: nuclear magnetic resonance imaging

Search Result 123, Processing Time 0.029 seconds

CT and MRI Image Fusion Reproducibility and Dose Assessment on Treatment Planning System (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Choi, Jae-Hyock;Park, Cheol-Soo;Seo, Jeong-Min;Cho, Jae-Hwan;Choi, Cheon-Woong
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.191-196
    • /
    • 2014
  • The purpose of this study is to evaluate the reproducibility and usefulness of an image through the fusion of the computed tomography image and the magnetic resonance image by using a self-produced phantom when planning the treatment, and also to compare and analyze the target dose on the acquired image. The size of small hole and the reproducibility of capacity existed in the phantom on the image of the phantom obtained by the computed tomography and the magnetic resonance image of the phantom scanning with different intensity of magnetic field are compared, and the change of dose in the random target is compared and analyzed.

Use of Imaging and Biopsy in Prostate Cancer Diagnosis: A Survey From the Asian Prostate Imaging Working Group

  • Li-Jen Wang;Masahiro Jinzaki;Cher Heng Tan;Young Taik Oh;Hiroshi Shinmoto;Chau Hung Lee;Nayana U. Patel;Silvia D. Chang;Antonio C. Westphalen;Chan Kyo Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1102-1113
    • /
    • 2023
  • Objective: To elucidate the use of radiological studies, including nuclear medicine, and biopsy for the diagnosis and staging of prostate cancer (PCA) in clinical practice and understand the current status of PCA in Asian countries via an international survey. Materials and Methods: The Asian Prostate Imaging Working Group designed a survey questionnaire with four domains focused on prostate magnetic resonance imaging (MRI), other prostate imaging, prostate biopsy, and PCA backgrounds. The questionnaire was sent to 111 members of professional affiliations in Korea, Japan, Singapore, and Taiwan who were representatives of their working hospitals, and their responses were analyzed. Results: This survey had a response rate of 97.3% (108/111). The rates of using 3T scanners, antispasmodic agents, laxative drugs, and prostate imaging-reporting and data system reporting for prostate MRI were 21.6%-78.9%, 22.2%-84.2%, 2.3%-26.3%, and 59.5%-100%, respectively. Respondents reported using the highest b-values of 800-2000 sec/mm2 and fields of view of 9-30 cm. The prostate MRI examinations per month ranged from 1 to 600, and they were most commonly indicated for biopsy-naïve patients suspected of PCA in Japan and Singapore and staging of proven PCA in Korea and Taiwan. The most commonly used radiotracers for prostate positron emission tomography are prostate-specific membrane antigen in Singapore and fluorodeoxyglucose in three other countries. The most common timing for prostate MRI was before biopsy (29.9%). Prostate-targeted biopsies were performed in 63.8% of hospitals, usually by MRI-ultrasound fusion approach. The most common presentation was localized PCA in all four countries, and it was usually treated with radical prostatectomy. Conclusion: This survey showed the diverse technical details and the availability of imaging and biopsy in the evaluation of PCA. This suggests the need for an educational program for Asian radiologists to promote standardized evidence-based imaging approaches for the diagnosis and staging of PCA.

Molecular Imaging in the Age of Genomic Medicine

  • Byun, Jong-Hoe
    • Genomics & Informatics
    • /
    • v.5 no.2
    • /
    • pp.46-55
    • /
    • 2007
  • The convergence of molecular and genetic disciplines with non-invasive imaging technologies has provided an opportunity for earlier detection of disease processes which begin with molecular and cellular abnormalities. This emerging field, known as molecular imaging, is a relatively new discipline that has been rapidly developed over the past decade. It endeavors to construct a visual representation, characterization, and quantification of biological processes at the molecular and cellular level within living organisms. One of the goals of molecular imaging is to translate our expanding knowledge of molecular biology and genomic sciences into good patient care. The practice of molecular imaging is still largely experimental, and only limited clinical success has been achieved. However, it is anticipated that molecular imaging will move increasingly out of the research laboratory and into the clinic over the next decade. Non-invasive in vivo molecular imaging makes use of nuclear, magnetic resonance, and in vivo optical imaging systems. Recently, an interest in Positron Emission Tomography (PET) has been revived, and along with optical imaging systems PET is assuming new, important roles in molecular genetic imaging studies. Current PET molecular imaging strategies mostly rely on the detection of probe accumulation directly related to the physiology or the level of reporter gene expression. PET imaging of both endogenous and exogenous gene expression can be achieved in animals using reporter constructs and radio-labeled probes. As increasing numbers of genetic markers become available for imaging targets, it is anticipated that a better understanding of genomics will contribute to the advancement of the molecular genetic imaging field. In this report, the principles of non-invasive molecular genetic imaging, its applications and future directions are discussed.

Correlation Between Unidentified Bright Objects on Brain Magnetic Resonance Imaging (MRI) and Cerebral Glucose Metabolism in Patients with Neurofibromatosis Type 1

  • Sohn, Young Bae;An, Young Sil;Lee, Su Jin;Choi, Jin Wook;Jeong, Seon-Yong;Kim, Hyon-Ju;Ko, Jung Min
    • Journal of Genetic Medicine
    • /
    • v.9 no.2
    • /
    • pp.84-88
    • /
    • 2012
  • Purpose: Neurofibromatosis type 1 (NF1), which is caused by mutations of the NF1 gene, is the most frequent single gene disorder to affect the nervous system. Unidentified bright objects (UBOs) are commonly observed on brain magnetic resonance imaging (MRI) in patients with NF1. However, their clinical and pathologic significance is not well understood. The purpose of this study was to investigate the correlation between UBOs and cerebral glucose metabolism measured by $^{18}F$-2-Fluoro-2-deoxy-D-glucose ($^{18}F$-FDG) positron emission tomography (PET) in Korean patients with NF1. Materials and Methods: Medical records of 75 patients (34 males and 41 females) with NF1 who underwent brain MRI and PET between 2005 and 2011 were evaluated retrospectively. Clinical data including demographics, neurological symptoms, and brain MRI and PET findings, were reviewed. Results: UBOs were detected in the brain MRI scans of 31 patients (41%). The region most frequently affected by UBOs was the basal ganglia. The most frequent brain PET finding was thalamic glucose hypometabolism (45/75, 60%). Of the 31 patients with UBOs, 26 had thalamic glucose hypometabolism on brain PET, but the other 5 had normal brain PET findings. Conversely, of the 45 patients with thalamic glucose hypometabolism on brain PET, 26 showed UBOs on their brain MRI scans, but 19 had normal findings on brain MRI scans. Conclusion: UBOs on brain MRI scans and thalamic glucose hypometabolism on PET appear to be 2 distinctive features of NF1 rather than correlated symptoms. Because the clinical significance of these abnormal imaging findings remains unclear, a longitudinal follow-up study of changes in clinical manifestations and imaging findings is necessary.

Prognostic value of $^{18}F$-fluorodeoxyglucose positron emission tomography, computed tomography and magnetic resonance imaging in oral cavity squamous cell carcinoma with pathologically positive neck lymph node

  • Jwa, Eunjin;Lee, Sang-Wook;Kim, Jae-Seung;Park, Jin Hong;Kim, Su Ssan;Kim, Young Seok;Yoon, Sang Min;Song, Si Yeol;Kim, Jong Hoon;Choi, Eun Kyung;Ahn, Seung Do
    • Radiation Oncology Journal
    • /
    • v.30 no.4
    • /
    • pp.173-181
    • /
    • 2012
  • Purpose: To evaluate the prognostic value of preoperative neck lymph node (LN) assessment with $^{18}F$-fluorodeoxyglucose positron emission tomography ($^{18}F$-FDG PET), computed tomography (CT), and magnetic resonance imaging (MRI) in oral cavity squamous cell carcinoma (OSCC) patients with pathologically positive LN. Materials and Methods: In total, 47 OSCC patients with pathologically positive LN were retrospectively reviewed with preoperative $^{18}F$-FDG PET and CT/MRI. All patients underwent surgical resection, neck dissection and postoperative adjuvant radiotherapy and/or chemotherapy between March 2002 and October 2010. Histologic correlation was performed for findings of $^{18}F$-FDG PET and CT/MRI. Results: Thirty-six (76.6%) of 47 cases were correctly diagnosed with neck LN metastasis by $^{18}F$-FDG PET and 32 (68.1%) of 47 cases were correctly diagnosed by CT/MRI. Follow-up ranged from 20 to 114 months (median, 56 months). Clinically negative nodal status evaluated by $^{18}F$-FDG PET or CT/MRI revealed a trend toward better clinical outcomes in terms of overall survival, disease-free survival, local recurrence-free survival, regional nodal recurrence-free survival, and distant metastasis-free survival rates even though the trends were not statistically significant. However, there was no impact of neck node standardized uptake value ($SUV_{max}$) on clinical outcomes. Notably, $SUV_{max}$ showed significant correlation with tumor size in LN (p < 0.01, $R^2$ = 0.62). PET and CT/MRI status of LN also had significant correlation with the size of intranodal tumor deposit (p < 0.05, $R^2$ = 0.37 and p < 0.01, $R^2$ = 0.48, respectively). Conclusion: $^{18}F$-FDG PET and CT/MRI at the neck LNs might improve risk stratification in OSCC patients with pathologically positive neck LN in this study, even without significant prognostic value of $SUV_{max}$.

Are There Any Additional Benefits to Performing Positron Emission Tomography/Computed Tomography Scans and Brain Magnetic Resonance Imaging on Patients with Ground-Glass Nodules Prior to Surgery?

  • Song, Jae-Uk;Song, Junwhi;Lee, Kyung Jong;Kim, Hojoong;Kwon, O Jung;Choi, Joon Young;Kim, Jhingook;Han, Joungho;Um, Sang-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.4
    • /
    • pp.368-376
    • /
    • 2017
  • Background: A ground-glass nodule (GGN) represents early-stage lung adenocarcinoma. However, there is still no consensus for preoperative staging of GGNs. Therefore, we evaluated the need for the routine use of positron emission tomography/computed tomography (PET)/computed tomography (CT) scans and brain magnetic resonance imaging (MRI) during staging. Methods: A retrospective analysis was undertaken in 72 patients with 74 GGNs of less than 3 cm in diameter, which were confirmed via surgery as malignancy, at the Samsung Medical Center between May 2010 and December 2011. Results: The median age of the patients was 59 years. The median GGN diameter was 18 mm. Pure and part-solid GGNs were identified in 35 (47.3%) and 39 (52.7%) cases, respectively. No mediastinal or distant metastasis was observed in these patients. In preoperative staging, all of the 74 GGNs were categorized as stage IA via chest CT scans. Additional PET/CT scans and brain MRIs classified 71 GGNs as stage IA, one as stage IIIA, and two as stage IV. However, surgery and additional diagnostic work-ups for abnormal findings from PET/CT scans classified 70 GGNs as stage IA, three as stage IB, and one as stage IIA. The chest CT scans did not differ from the combined modality of PET/CT scans and brain MRIs for the determination of the overall stage (94.6% vs. 90.5%; kappa value, 0.712). Conclusion: PET/CT scans in combination with brain MRIs have no additional benefit for the staging of patients with GGN lung adenocarcinoma before surgery.

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

Ex Vivo ${1}^H$ MR Spectroscopy: Normal gastric and cancer tissue (정상 위 조직과 위암 조직의 시험관 내 수소자기공명분광)

  • Cho Ji Youn;Shin Oon Jae;Choi Ki Seung;Kim Su Hyun;Eun Choong Ki;Yang Young Il;Lee Jung Hee;Mun Chi Woong
    • Journal of Gastric Cancer
    • /
    • v.3 no.3
    • /
    • pp.151-157
    • /
    • 2003
  • Purpose: In this study, we attempted to ascertain the proton magnetic resonance spectroscopy (${1}^H$ MRS) peak characteristics of human gastric tissue layers and finally to use the metabolic peaks of MRS to distinguish between normal and abnormal gastric specimens. Materials and Methods: Ex-vivo ${1}^H$ MRS examinations of thirty-five gastric specimens were performed to distinguish abnormal gastric tissues invaded by carcinoma cells from normal stomach-wall tissues. High-resolution 400-MHz (9.4-T) ${1}^H$ nuclear magnetic resonance (NMR) spectra of two gastric layers, a proper muscle layer, and a composite mucosasubmucosa layer were compared with those of clinical 64- MHz (1.5-T) MR spectra. Three-dimensional spoiled gradient recalled (SPGR) images were used to determine the size and the position of a voxel for MRS data collection. Results: For normal gastric tissue layers, the metabolite peaks of 400-MHz ${1}^H$ MRS were primarily found to be as follows: lipids at 0.9 ppm and 1.3 ppm; alanine at 1.58 ppm; N-acetyl neuraminic acid (sialic acid) at 2.03 ppm; and glutathione at 2.25 ppm in common. The broad and featureless featureless spectral peaks of the 64-MHz MRS were bunched near 0.9, 1.3, and 2.0, and 2.2 ppm in human specimens without respect to layers. In a specimen (Borrmmann type III) with a tubular adenocarcinoma, the resonance peaks were measured at 1.26, 1.36 and 3.22 ppm. All the peak intensities of the spectrum of the normal gastric tissue were reduced, but for gastric tumor tissue layers, the lactate peak split into 1.26 and 1.39 ppm, and the peak intensity of choline at 3.21 ppm was increased. Conclusion: We found that decreasing lipids, an increasing lactate peak that split into two peaks, 1.26 ppm and 1.36 ppm, and an increasing choline peak at 3.22 ppm were markers of tumor invasion into the gastric tissue layers. This study implies that MR spectroscopy can be a useful diagnostic tool for gastric cancer.

  • PDF

Difficulties in Differentiating Cardiac Lymphoma and Metastasis Based on Radiologic Features: Two Case Reports (영상 소견으로 감별이 어려운 원발성 심장 림프종과 심장 전이암: 2예 보고)

  • Hyun Jae Lim;Song Soo Kim;Kye Taek Ahn;Kun Ho Kim;Jin Hwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1575-1580
    • /
    • 2021
  • Cardiac tumors are rare diseases with various imaging findings. However, differentiating cardiac tumors based on imaging findings is challenging because of similarities in imaging features. We present two cases of cardiac tumors, including primary cardiac lymphoma and cardiac metastasis, in which the differential diagnosis was difficult.

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.