• Title/Summary/Keyword: nuclear facilities

Search Result 734, Processing Time 0.022 seconds

The capacity loss of a RCC building under mainshock-aftershock seismic sequences

  • Zhai, Chang-Hai;Zheng, Zhi;Li, Shuang;Pan, Xiaolan
    • Earthquakes and Structures
    • /
    • v.15 no.3
    • /
    • pp.295-306
    • /
    • 2018
  • Reinforced concrete containment (RCC) building has long been considered as the last barrier for keeping the radiation from leaking into the environment. It is important to quantify the performance of these structures and facilities considering extreme conditions. However, the preceding research on evaluating nuclear power plant (NPP) structures, particularly considering mainshock-aftershock seismic sequences, is deficient. Therefore, this manuscript serves to investigate the seismic fragility of a typical RCC building subjected to mainshock-aftershock seismic sequences. The implementation of the fragility assessment has been performed based on the incremental dynamic analysis (IDA) method. A lumped mass RCC model considering the tri-linear skeleton curve and the maximum point-oriented hysteretic rule is employed for IDA analyses. The results indicate that the seismic capacity of the RCC building would be overestimated without taking into account the mainshock-aftershock effects. It is also found that the seismic capacity of the RCC building decreases with the increase of the relative intensity of aftershock ground motions to mainshock ground motions. In addition, the effects of artificial mainshock-aftershock ground motions generated from the repeated and randomized approaches and the polarity of the aftershock with respect to the mainshock on the evaluation of the RCC are also researched, respectively.

Finite Element Method Analysis of Eddy Current Array Probe According to Defects Variation of Steam Generator (배열와전류프로브를 이용한 증기발생기 세관의 결함 변화에 따른 유한요소해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.54-58
    • /
    • 2009
  • In this paper, the ECT(eddy current testing) signal analysis of eddy current array probe for inspection of SG(steam generator) tube in NPP(nuclear power plant) using electromagnetic FEM(finite element method) was performed. To obtain the electromagnetic characteristics of probes, the governing equation was derived from Maxwell's equation, and the problem was solved by using the 3-dimensional FEM. The types of defects were FBH(flat bottomed hole) and OD groove, Spiral groove, natural defects(pitting, SCC, multiple SCC, wear). The depth of FBH defects were 20%, 40%, 60%, 80%, 100 of SG tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequency of 100kHz, 300kHz and 400kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the variation of size and depth on FBH defects and operation frequencies. The results in this paper can be helpful when the ECT signals from EC array probe are evaluated and analyzed.

  • PDF

The Demands for Housing Regeneration of the Permanent Rental Apartment Dwellers -With Special Reference to Man-soo 7 Complex in Incheon- (영구임대아파트 거주자 주거지 재생 수요조사 연구 - 인천 만수주공 7단지 거주자를 중심으로 -)

  • Kim, Mi-Hee;Park, Byong-Gyu;Noh, Se-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.137-142
    • /
    • 2009
  • The purpose of this study is to collect baseline data about the demands for housing regeneration of the permanent rental apartment dwellers. Self-administered questionaires and interviews were provided to 144 dwellers in Incheon Man-soo 7 complex from 2008 December 29th to 31st. The collected data was used to conduct comparative and descriptive statistical analysis: frequency, t-test, and $X^2$-test. The main findings are as follows : 1. House repairing and papering is most common used service by respondents. They also have much need for economic support. 2. Residents were satisfied with general environment of house. This survey showes that the highest satisfaction was about using food waste disposal sites. and the lowest satisfaction was about soundproof facilities on the other hand, among the questions. 3. Dwellers wanted to remodeling such as bathroom, restroom, a flower garden, space of landscape architecture. More than half dwellers preferred to leave among themselves living at permanent rental apartment as it is. 4. There is important difference in the demands of housing regeneration as the family trait. and variables of those were nuclear family or elderly/handicapped-family.

  • PDF

The Demands for Housing Regeneration of the Permanent Rental Apartment Dwellers - With Special Reference to Man-soo 7 Complex in Incheon - (영구임대아파트 거주자 주거지 정비 수요조사 연구 - 인천 만수주공 7단지 거주자를 중심으로 -)

  • Kim, Mi-Hee;Park, Byong-Gyu;Noh, Se-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.43-51
    • /
    • 2010
  • The purpose of this study is to collect baseline data about the demands for housing regeneration of the permanent rental apartment dwellers. Self-administered questionnaires and interviews were provided to 144 dwellers in Incheon Man-soo 7 complex from 2008 December 29th to 31 st. The collected data was used to conduct comparative and descriptive statistical analysis: frequency, t-test, and $\chi^2$-test. The main findings are as follows: 1. House repairing and papering is most common used service by respondents. They also have much need for economic support. 2. Residents were satisfied with general environment of house. This survey shows that the highest satisfaction was about using food waste disposal sites, and the lowest satisfaction was about soundproof facilities on the other hand, among the questions. 3. Dwellers wanted to remodeling such as bathroom, restroom, a flower garden, space of landscape architecture. More than half dwellers preferred to leave among themselves living at permanent rental apartment as it is. 4. There is important difference in the demands of housing regeneration as the family trait, and variables of those were nuclear family or elderly, handicapped-family.

A Study on Measurement of Internal Defects of Pressure Vessel by Digital Shearography and Finite Element Method (전자 전단 간섭법과 유한요소법을 이용한 압력용기의 내부결함 측정에 관한 연구)

  • 강영준;강형수;채희창
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.2
    • /
    • pp.29-37
    • /
    • 2001
  • The application of laser in pipelines was started from the base of using laser in nuclear facilities industries and power plants. Because laser can be delivered to a remote area without any difficulties, the application of laser in many industries can solve many difficulties from limitation of access in danger area and reduced the risks of workers. Therefore, we developed a new experimental technique to measure internal defects of pressure vessels with a combination of shearog-raphy and image processing technique. Conventional NDT methods have been taken relatively much time, money and manpower because of performing as the method of contact with objects to be inspected. But digital shearography is laser-based optical method which allows full-field observation of surface displacement derivatives. This method has many advantages in practical use, such as low sensitivity to environmental noise, simple optical configuration and real time mea-surement. In this paper, we find the optimum shearing magnitude with EFM and experiment and measured internal crack length of the pressure vessels at a real time and estimated the error of the results.

  • PDF

The Case of Novel Attack Detection using Virtual Honeynet (Virtual Honeynet을 이용한 신종공격 탐지 사례)

  • Kim, Chun-Suk;Kang, Dae-Kwon;Euom, Ieck-Chae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.2
    • /
    • pp.279-285
    • /
    • 2012
  • Most national critical key infrastructure, such like electricity, nuclear power plant, and petroleum is run on SCADA (Supervisory Control And Data Acquisition) system as the closed network type. These systems have treated the open protocols like TCP/IP, and the commercial operating system, which due to gradually increasing dependence on IT(Information Technology) is a trend. Recently, concerns have been raised about the possibility of these facilities being attacked by cyber terrorists, hacking, or viruses. In this paper, the method to minimize threats and vulnerabilities is proposed, with the virtual honeynet system architecture and the attack detection algorithm, which can detect the unknown attack patterns of Zero-Day Attack are reviewed.

Two phase convective heat transfer augmentation in swirl flow with non-boiling (비비등 선회유동에서의 2상 대류열전달 증가)

  • ;;Kim, J. G.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2586-2594
    • /
    • 1995
  • Two phase flow phenomena are observed in many industrial facilities and make much importance of optimum design for nuclear power plant and various heat exchangers. This experimental study has been investigated the classification of the flow pattern, the local void distribution and convective heat transfer in swirl and non-swirl two phase flow under the isothermal and nonisothermal conditions. The convective heat transfer coefficients in the single phase water flow were measured and compared with the calculated results from the Sieder-Tate correlation. These coefficients were used for comparisons with the two-phase heat transfer coefficients in the flow orientations. The experimental results indicate, that the void probe signal and probability density function of void distribution can used into classify the flow patterns, no significant difference in voidage distribution was observed between isothermal and non-isothermal condition in non-swirl flow, the values of two phase heat transfer coefficients increase when superficial air velocities increase, and the enhancement of the values is observed to be most pronounced at the highest superficial water velocity in non-swirl flow. Also two phase heat transfer coefficients in swirl flow are increased when the twist ratios are decreased.

Development of decontamination equipment to remove hot particulates contaminated in hot cell at KAERI

  • Kim Gye-Nam;Narayan M.;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.258-268
    • /
    • 2005
  • A new approach has been adopted to remove the hot particulates from nuclear facilities, KAERI, South Korea, by using the new compact cyclone train, made of steel ness steel, with optional vortex finder length. Flow rate results showed a dramatic change in removal efficiency, performance was changed with the change of exit tube length. The 15 m/s flow rate was found suitable one for new equipment with the 49 mm optimum exit tube length for 76 mm cyclone body diameter. Results shows the removal efficiency for $1\;{\mu}m$ was more than $65\%$ and for $10\;{\mu}m$ was seen ${\~}97\%$. Over 15 m/s flow rate, was not shown much different in removal efficiency. The removal efficiency increased with the flow rate, and pressure drop. Cut size diameter decrease with the inlet flow rate. Cut size diameter found lowest with 49 mm exit tube length and 15 m/s flow rate. For filters the performance decreased with the inlet velocity increased.

  • PDF

Consideration on the helium leak detection in a large vacuum chamber (대형 진공용기의 헬륨 누설검사 방법에 대한 고찰)

  • In, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.235-243
    • /
    • 2007
  • Nowadays, in our country, large vacuum chambers for huge experimental facilities such as the tokamak fusion device, high power neural beam test stand, and space simulator have been constructed. In such a vacuum chamber of very large size, it is quite complicate to check on leakage quantitatively, while the probability of a leak is relatively high. To investigate the feasibility of applying reliably a helium leak detection to the huge vacuum chambers, and to find a reasonable methodology of choosing an optimum set-up for leak detection, several virtual constructions of the leak detection system have been analyzed by calculating the pressure distribution in the system and the helium level in the sensor part.

Photonic sensors for micro-damage detection: A proof of concept using numerical simulation

  • Sheyka, M.;El-Kady, I.;Su, M.F.;Taha, M.M. Reda
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.483-494
    • /
    • 2009
  • Damage detection has been proven to be a challenging task in structural health monitoring (SHM) due to the fact that damage cannot be measured. The difficulty associated with damage detection is related to electing a feature that is sensitive to damage occurrence and evolution. This difficulty increases as the damage size decreases limiting the ability to detect damage occurrence at the micron and submicron length scale. Damage detection at this length scale is of interest for sensitive structures such as aircrafts and nuclear facilities. In this paper a new photonic sensor based on photonic crystal (PhC) technology that can be synthesized at the nanoscale is introduced. PhCs are synthetic materials that are capable of controlling light propagation by creating a photonic bandgap where light is forbidden to propagate. The interesting feature of PhC is that its photonic signature is strongly tied to its microstructure periodicity. This study demonstrates that when a PhC sensor adhered to polymer substrate experiences micron or submicron damage, it will experience changes in its microstructural periodicity thereby creating a photonic signature that can be related to damage severity. This concept is validated here using a three-dimensional integrated numerical simulation.