• Title/Summary/Keyword: nsF5

Search Result 60, Processing Time 0.028 seconds

Recognizing F5-like stego images from multi-class JPEG stego images

  • Lu, Jicang;Liu, Fenlin;Luo, Xiangyang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.11
    • /
    • pp.4153-4169
    • /
    • 2014
  • To recognize F5-like (such as F5 and nsF5) steganographic algorithm from multi-class stego images, a recognition algorithm based on the identifiable statistical feature (IDSF) of F5-like steganography is proposed in this paper. First, this paper analyzes the special modification ways of F5-like steganography to image data, as well as the special changes of statistical properties of image data caused by the modifications. And then, by constructing appropriate feature extraction sources, the IDSF of F5-like steganography distinguished from others is extracted. Lastly, based on the extracted IDSFs and combined with the training of SVM (Support Vector Machine) classifier, a recognition algorithm is presented to recognize F5-like stego images from images set consisting of a large number of multi-class stego images. A series of experimental results based on the detection of five types of typical JPEG steganography (namely F5, nsF5, JSteg, Steghide and Outguess) indicate that, the proposed algorithm can distinguish F5-like stego images reliably from multi-class stego images generated by the steganography mentioned above. Furthermore, even if the types of some detected stego images are unknown, the proposed algorithm can still recognize F5-like stego images correctly with high accuracy.

Characteristics of Partial Discharge Under HVDC in SF6 Gas (SF6 가스 중 직류 고전압 하에서 부분방전 특성)

  • Kim, Min-Su;Kim, Sun-Jae;Jeong, Gi-Woo;Jo, Hyang-Eun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.4
    • /
    • pp.238-243
    • /
    • 2014
  • This paper dealt with the measurement and analysis of partial discharge (PD) under high voltage direct current (HVDC) in SF6 gas. Electrode systems such as a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack on epoxy plate and a free particle (FP) were fabricated to simulate the insulation defects. The analysis system was designed with a Time-Frequency (T-F) map algorithm programed based on LabVIEW. This can arrange the acquired PD pulses into frequency and time domain. A HVDC power source is composed of a transformer (220 V/50 kV), a diode (100 kV) and a capacitor (50 kV, 0.5 ${\mu}F$). The gap between the electrodes is 3 mm, and the $SF_6$ gas was set at 5 bar. PD pulses were detected by a 50 ${\Omega}$ non-inductive resistor. In the analysis, PD pulses were distributed below 0.5 MHz and 20 ns ~ 35 ns for the POC, 0.7 MHz ~ 1.7 MHz, below 0.6 MHz and 10 ns ~ 40 ns and 60 ns ~125 ns for the POE, below 0.1 MHz and 135 ns ~ 215 ns for the crack, and below 1.6 MHz and 250 ns for the FP.

Systematic Identification of Hepatocellular Proteins Interacting with NS5A of the Hepatitis C Virus

  • Ahn, Ji-Won;Chung, Kyung-Sook;Kim, Dong-Uk;Won, Mi-Sun;Kim, Li-La;Kim, Kyung-Shin;Nam, Mi-Young;Choi, Shin-Jung;Kim, Hyoung-Chin;Yoon, Mi-Chung;Chae, Suhn-Kee;Hoe, Kwang-Lae
    • BMB Reports
    • /
    • v.37 no.6
    • /
    • pp.741-748
    • /
    • 2004
  • The hepatitis C virus is associated with the development of liver cirrhosis and hepatocellular carcinomas. Among the 10 polyproteins produced by the virus, no function has been clearly assigned to the non-structural 5A (NS5A) protein. This study was designed to identify the hepatocellular proteins that interact with NS5A of the HCV. Yeast two-hybrid experiments were performed with a human liver cDNA prey-library, using five different NS5A derivatives as baits, the full-length NS5A (NS5A-F, amino acid (aa) 1~447) and its four different derivatives, denoted as NS5A-A (aa 1~150), -B (aa 1~300), -C (aa 300~447) and D (aa 150~447). NS5A-F, NS5A-B and NS5A-C gave two, two and 10 candidate clones, respectively, including an AHNAK-related protein, the secreted frizzled-related protein 4 (SFRP4), the N-myc downstream regulated gene 1 (NDRG1), the cellular retinoic acid binding protein 1 (CRABP-1), ferritin heavy chain (FTH1), translokin, tumor-associated calcium signal transducer 2 (TACSTD2), phosphatidylinositol 4-kinase (PI4K) and $centaurin{\delta}$ 2 ($CENT{\delta}2$). However, NS5A-A produced no candidates and NS5A-D was not suitable as bait due to transcriptional activity. Based on an in vitro binding assay, CRABP-1, PI4K, $CENT{\delta}2$ and two unknown fusion proteins with maltose binding protein (MBP), were confirmed to interact with the glutathione S-transferase (GST)/NS5A fusion protein. Furthermore, the interactions of CRABP-1, PI4K and $CENT{\delta}2$ were not related to the PXXP motif (class II), as judged by a domain analysis. While their biological relevance is under investigation, the results contribute to a better understanding of the possible role of NS5A in hepatocellular signaling pathways.

Bipolar Integrated Optical Link Receiver with Low Supply Voltage (바이폴라 집적된 저전압구동 광연결 수신기)

  • 장지근;이상열
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.4
    • /
    • pp.9-14
    • /
    • 2003
  • The new optical link receiver with data transfer rate higher than 10Mbps at the supply voltage of 1.8V was designed and fabricated using bipolar technology. The fabricated IC showed the dissipation current of 4.6mA under high level input voltage of 1.5V. The high level output voltage($V_{OH}$) and the low level output voltage($V_{OL}$) were 1.15V and 0V, respectively, for a given 10 Mbps signal which has duty ratio of 50%, $V_{IL}$(low level input voltage) of 0.5V, and $V_{IH}$(high level input voltage) of 1.5V, The duty ratio of output waveform was 52.6%. The rising time(t$_{r}$) and the falling time(t$_{f}$) were 9.5ns and 6.8ns, respectively. The propagation delay difference($t_{PHC}-t_{PLH}$) and the jitter($t_j$) were 11.7ns and 4.3ns, respectively.y.

  • PDF

Optimization of the Large Scale Magnetic Pulse Compression System of 100 ns-order (100 ns급 대용량 자기펄스 압축시스템의 최적화)

  • 이용우;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.442-445
    • /
    • 2003
  • In this study, we developed the 40 J-class MPC(magnetic pulse compression) system for exciting excimer laser and investigated the optimal conditions of each stage of MPC circuit. This system consists of a DC power supply, a pulse transformer and four saturable inductors. The number of turns of saturable inductors at each stage of MPC circuit are 140, 25, 5, 1 and the optimal storage capacitance of each stage are 34 nF, 28.9 nF, 22.1 nF, respectively. In the improvement MPC system, we have obtained an output voltage of 43 kV, a current of 8.25 kA and a pulse duration of 360 ns. Also, the maximum pulse compression ratio of 77.7 and the current gain of 71.7 were obtained.

  • PDF

A Study on Laryngeal Behavior of Persons Who Stutter with Fiber-Optic Nasolaryngoscope (후두 내시경(Fiber-Optic Nasolaryngoscope)을 이용한 말더듬인의 후두양상에 관한 연구)

  • Jung, Hun;Ahn, Jong-Bok;Choi, Byung-Heun;Kwon, Do-Ha
    • Speech Sciences
    • /
    • v.15 no.3
    • /
    • pp.159-173
    • /
    • 2008
  • The purpose of this study was to use fiber-optic nasolaryngoscope to find out differences in laryngeal behavior between persons who stutter(PS) and those who do not stutter(NS) upon their utterance. To meet the goal above, this study took 5 NS and 5 PS respectively as a part of sampling, so that they were all asked to join an experiment hereof. As a result, this study came to the following findings: First, there was not any significant difference in laryngeal behavior of uttering spoken languages between stuttering group and control. Second, there were some differences in laryngeal behavior of repetition and prolongation, which were a sort of disfluency revealed in the utterance of nonfluent spoken languages between stuttering group and control. Third, as reported by prior studies, it was found that there were differences in laryngeal abehavior of stutterer group's nonfluent spoken languages depending upon stuttering types. In this study, a variety of laryngeal behavior unreported in prior studies could be found. In addition, it was notable that stutterers showed different laryngeal behavior depending on their personal stuttering types. On block condition, Subject 1 showed laryngeal behavior of fAB, INT and fAD; Subject 2 showed laryngeal behavior of fAB, fAD and rAD; Subject 3 showed laryngeal behavior of fAD and rAD; Subject 4 showed only laryngeal behavior of fAD; and Subejct 5 showed laryngeal behavior of fAB, fAD and rAD. Summing up, these findings imply that when stutterers utter nonfluent words, they may reveal a variety of laryngeal behavior depending on their personal stuttering types. Moreover, it is found that there are more or less differences in the utterance of nonfluent spoken languages between NS and stuttering ones. In particular, it is interesting that one common trait of nonfluent spoken languages uttered by PS is evidently excessive laryngeal stress, no matter which type of stuttering they reveal.

  • PDF

Simulation Anaysis on the Output Characteristics of XeF$(C\rightarrowA$ Excimer Laser Pumped by Electron-Beam (전자빔여기 XeF$(C\rightarrowA$ 엑시머 레이저의 출력특성에 대한 시뮬레이션 해석)

  • 류한용;이주희
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.201-213
    • /
    • 1995
  • By the use of computer simulation including collisional mixing kinetic processes of the B- and C-state in the upper laser level the output characteristics of electron-beam pumped XeF$(C\rightarrowA$ excimer laser are analyzed. We compared the results between experiments and simulations for the $XeF^*(C)$ formation that correlated the number of densities of the $XeF^*(B)$. We obtained good agreement$(28.5 mJ\pm5%)$ with comparisons between experiment and simulation and confirmed the optimal gas mixing ratio of $Xe/F_2/Ar=5.26/0.49/94.28%$ at atmospheric pressure laser medium under the condition of 70 ns [FWHM] electron-beam (800 kV, 21 kA). Also through the simulation we have investigated that the $XeF^*(C)$ formation channel, the $XeF^*(C)$ relaxation channel, and the absorption channel of bluegreen wavelength region as a function of F2 halogen donor and Xe partial pressure. ssure.

  • PDF

Output Characteristics of XeF$(C\rightarrowA$ Laser for the variation of Xe concentration under the pressures of broad region (넓은 범위의 압력에서 Xe 농도 변화에 대한 XeF$(C\rightarrowA$ 레이저의 출력특성)

  • 류한용;이주희
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.214-221
    • /
    • 1995
  • When the broad pressure region (0.5-3.5 atm) of laser media is pumped by 70 ns [FWHM] electronbeam accelerator (800 kV, 21 kA), the correlation between free-runnuing XeF$(C\rightarrowA$ excimer laser output and Xe concentration are studied. The resonator consisted of dichroic output coupler, and the laser output is optimized with laser media $(Xe/F_2/Ar)$ as functions of total pressure and gas mixing ratio. Under the condition of F2 0.46% fixed, the laser intrinsic efficiencies of 0.38%, 1.03%, and 0.29% are obtained at 1. 2, and 3 atm, respectively. So then the peaks of laser intrinsic efficiency occured to the higher Xe concentration with decreasing total gas pressure. By analyzing the kinetics for the $XeF^*(C)$ formation efficiency and XeF$(C\rightarrowA$ laser extraction efficiency the dependence of Xe concentration on their correlation is explained. As the results we propose efficient operation of an atmosphericpressure XeF$(C\rightarrowA$ laser. laser.

  • PDF

The Phylogenetic Analysis of the NS-5 Region Sequence of Hepatitis G Viruses Isolated in Korea (국내에서 분리된 G형 간염바이러스 NS-5 Region 염기서열의 계통학적 분석)

  • Jee, Young-Mee;Kim, Ki-Soon;Cheon, Doo-Sung;Park, Jeong-Koo;Kang, Young-Hwa;Lee, Yoon-Sung;Chung, Yoon-Suk;Kim, Ji-Eun;Yoon, Jae-Deuk
    • The Journal of Korean Society of Virology
    • /
    • v.29 no.1
    • /
    • pp.45-53
    • /
    • 1999
  • We examined the hepatitis G virus infections among 227 Koreans who were healthy or were suspected of hepatitis and determined the phylogenetic relationship based on a part of the NS-5 region of 5 positive samples. Viral RNA was extracted from sera and cDNA was synthesized and subsequently amplified by RT-PCR (reverse transcription-polymerase chain reaction) or RT-nested PCR using random hexamer and NS-5 specific primers (470-20-1-77F, 470-20-1-211R, HGVNESTFO, HGVNESTRE). Five positives were found to belong to samples of patients showing symptoms of viral hepatitis. Primers used for PCR or nested PCR were derived from the NS-5 region. On the other hand, no amplification was detected using primers derived from the 5'-NCR (G-146F, G-401R). We performed TA cloning and sequencing of 5 amplified fragments, and their sequences were compared with those of foreign isolates of HGV. The phylogenetic analysis using MegAlign programme of DNAstar has shown that the Korean isolates are clustered on the phylogenetic tree. In summary, we confirmed the hepatitis G virus infection in 5 cases out of 12 patients showing the symptoms of viral hepatitis. The phylogenetic analysis of sequences of 5 amplified fragments showed that their relations to each other were closer than those to the foreign HGV isolates reported.

  • PDF

Study on Sensitivity of Burst-Mode Optical Receiver Depending on Photodiode Capacitance (포토다이오드의 정전용량에 따른 버스트모드 광 수신소자의 수신감도 연구)

  • Lee, Jung-Moon;Kim, Chang-Bong
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.343-348
    • /
    • 2008
  • This study was carried out to commercialize FTTH by developing a burst mode optical receiver for E-PON. The optical receiver was manufactured by minimizing the capacitance of a photodiode to improve sensitivity for meeting 10, 20 km OLT Rx standard of E-PON at the transmission speed of 1.25 Gb/s. When bit-error ratio is $10^{-12}$ and PRBS is $2^5-1$, sensitivity is -26 dBm, loud/soft ratio is 23 dB. Both preamble time and guard time were set to 102.4 ns (128 bit). After comparing a photodiode whose capacitance is 0.53 pF with another photodiode whose capacitance has been minimized to 0.26 pF, we could see that sensitivity improved to 0.7 dBm and so did bandwidth to 190 MHz of burst mode for the optical receiver manufactured by the photodiode whose capacitance is 0.26 pF.