• Title/Summary/Keyword: normal value

Search Result 3,448, Processing Time 0.032 seconds

A Study of Psychometric Function Curve for Korean Standard Monosyllabic Word Lists for Preschoolers (KS-MWL-P) (한국표준 학령전기용 단음절어표 (Korean Standard Monosyllabic Word Lists for Preschoolers, KS-MWL-P)의 심리음향기능곡선 연구)

  • Shin, Hyun-Wook;Kim, Jin-Sook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.534-541
    • /
    • 2009
  • Word recognition test (WRT) for the children can be useful for diagnosing the degree of communication disability, prescribing hearing instruments, planning aural rehabilitation and speech therapy, and determination of site of lesions. The Korean standard monosyllabic word lists for preschoolers (KS-MWL-P) were developed considering the criteria given by the literatures. However, the authors of KS-MWL-P suggested more children should be included to verify homogeneity of the lists using psychometric function curve since only 8 children participated in the developing process. The purpose of this study was to explore the homogeneity of KS-MWL-P for supplementing the limitations of the lists employing psychometric analysis. To 23 preschoolers who have normal-hearing, 100 monosyllabic KS-MWL-P words were examined with the pictures. Psychometric function curve with linear slopes of 20% and 80%'s correct rates through accounting recognition scores of each monosyllabic word at variable intensities from -10 to 40 dBHL was obtained and analyzed. As a result, s-shaped psychometric function curve was presented with increasing correct rate depending on intensity and showed no statistical significant differences among each word and list. The congruous graph shapes among lists also indicated good homogeneity and the list 1,2,3,4's average slopes were 4.48, 3.86, 4.65, 4.50. It was verified that the homogeneity was suitable because the analysis of variance showed no statistical significance among lists (p>0.05). However, KS-MWL-P's order of slope according to the order of the number of items, $1{\sim}10$, $1{\sim}20$, $1{\sim}25$ showed no difference with the p-value of 0.93, 0.59, 0.91, 0.70 for the lists 1,2,3, and 4, respectively. Although KS-MWL-P was assumed that the lower-numbered items were easy for testing younger ages, this study's results could not agree with the author's conclusion. Considering this matter, rearranging of the number of items should be performed according to the analysis of slope suggested by this study for testing younger children with easier items. Other than this, in conclusion, KS-MWL-P was proved to be useful for clinical and rehabilitative evaluating and training tools for preschoolers.

A Study on the Continuous Usage Intention Factors of O2O Service (O2O 서비스의 지속사용의도에 미치는 영향요인 연구)

  • Sung Yong Jung;Jin Soo Kim
    • Information Systems Review
    • /
    • v.20 no.4
    • /
    • pp.1-23
    • /
    • 2018
  • A smart phone has been widely spread around world and makes people enjoy online shopping in any time and any place. Recently it also changes the distribution environment. O2O (Online-to-Offline) service becomes new normal due to its convenience of ease shopping of product and services. O2O service market shows steady and steep growth, It is reported that, however, 80% of the businesses has been discontinued within the first year because of unstable business models, customer dissatisfaction and distrust of service. Therefore, it is very important research issue to find out influential factors promoting continuous usage intention of O2O service. Previous study shows that it only considers online characteristics and lack of analysis about offline characteristics and social impact factors. The purpose of this paper is to find out continuous usage intention factors of O2O services by literature review, case analysis, and empirical test. A comprehensive research model and related hypothesis are developed and tested by using a structural equation, Survey was carried out among users who have used O2O service including payment service for at least once. Finally 611 samples are selected out of total 813 surveys. The result shows that the model is theoretically proved and 12 out of 17 hypotheses are accepted. The contribution of this paper is that it provides a new theoretical research model about continuous usage intention factors as well as practical guidelines about promoting continuous usage and growth strategies of O2O service.

The Value of Interleukin-12 as an Activity Marker of Pulmonary Sarcoidosis (폐유육종증의 활동성 지표로서 IL-12의 효용성에 관한 연구)

  • Kim, Tae-Hyung;Jeon, Yong-Gam;Shim, Tae-Sun;Lim, Chae-Man;Koh, Yun-Suck;Lee, Sang-Do;Kim, Woo-Sung;Kim, Won-Dong;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.2
    • /
    • pp.215-228
    • /
    • 1999
  • Background: Sarcoidosis is a chronic granulomatous inflammatory disease of unknown etiology often involving the lungs and intrathoracic lymph nodes. The natural course of sarcoidosis is variable from spontaneous remission to significant morbidity or death. But, the mechanisms causing the variable clinical outcomes or any single parameter to predict the prognosis was not known. In sarcoidosis, the number and the activity of CD4 + lymphocytes are significantly increased at the loci of disease and their oligoclonality suggests that the CD4 + lymphocytes hyperreactivity may be caused by persistent antigenic stimulus. Recently, it has been known that CD4+ lymphocytes can be subdivided into 2 distinct population(Th1 and Th2) defined by the spectrum of cytokines produced by these cells. Th1 cells promote cellular immunity associated with delayed type hypersensitivity reactions by generating IL-2 and IFN-$\gamma$. Th2 cells playa role in allergic responses and immediate hypersensitivity reactions by secreting IL-4, IL-5, and IL-10. CD4+ lymphocytes in pulmonary sarcoidosis were reported to be mainly Th1 cells. IL-12 has been known to play an important role in differentiation of undifferentiated naive T cells to Th1 cells. And, Moller et al. observed increased IL-12 in bronchoalveolar lavage fluid(BALF) in patients with sarcoidosis. So it is possible that the elevated level of IL-12 is necessary for the continuous progression of the disease in active sarcoidosis. This study was performed to test the assumption that IL-12 can be a marker of active pulmonary sarcoidosis. Methods: We measured the concentration of IL-12 in BALF and in conditioned medium of alveolar macrophage(AM) using ELISA(enzyme-linked immunosorbent assay) method in 26 patients with pulmonary sarcoidosis(10 males, 16 females, mean age: $39.8{\pm}2.1$ years) and 11 normal control. Clinically, 14 patients had active sarcoidosis and 12 patients had inactive. Results: Total cells counts, percentage and number of lymhocytes, number of AM and CD4/CD8 lymphocyte ratio in BALF were significantly higher in patients with sarcoidosis than in control group. But none of these parameters could differentiate active sarcoidosis from inactive disease. The concentration of IL-12 in BALF was significantly increased in sarcoidosis patients ($49.3{\pm}9.2$ pg/ml) than in normal control ($2.5{\pm}0.4$ pg/ml) (p<0.001). Moreover it was significantly higher in patients with active sarcoidosis ($70.3{\pm}14.8$ pg/ml) than in inactive disease ($24.8{\pm}3.l$ pg/ml) (p=0.001). Also, the concentration of IL-12 in BALF showed significant correlation with the percentage of AM(p<0.001), percentage(p<0.001) and number of lymphocyte(p<0.001) in BALF, suggesting the close relationship between the level of IL-12 in BALF and the inflammatory cell infiltration in the lungs. Furthermore, we found a significant correlation between the level of IL-12 and the concentration of soluble ICAM-1 : in serum(p<0.001) and BALF (p=0.001), and also between IL-12 level and ICAM-1 expression of AM(p<0.001). The AM from patients with pulmonary sarcoidosis secreted significantly larger amount of IL-12 ($206.2{\pm}61.9$ pg/ml) than those of control ($68.3{\pm}43.7$ pg/ml) (p<0.008), but, there was no difference between inactive and active disease group. Conclusion : Our data suggest that the BALF IL-12 level can be used as a marker of the activity of pulmonary sarcoidosis.

  • PDF

The Role of Tumor Necrosis Factor-$\alpha$ and Interleukin-$1{\beta}$ as Predictable Markers for Development of Adult Respiratory Distress Syndrome in Septic Syndrome (패혈증 증후군환자에서 성인성 호흡곤란 증후군 발생의 예측 지표서의 혈중 Tumor Necrosis Factor-$\alpha$와 Interleukin-$1{\beta}$에 관한 연구)

  • Koh, Youn-Suck;Jang, Yun-Hae;Kim, Woo-Sung;Lee, Jae-Dam;Oh, Soon-Hwan;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.452-461
    • /
    • 1994
  • Background: Tumor necrosis factor(TNF)-$\alpha$ and Interleukin(lL)-$1{\beta}$ are thought to play a major role in the pathogenesis of the septic syndrome, which is frequently associated with adult respiratory distress syndrome(ARDS). In spite of many reports for the role of TNF-$\alpha$ in the pathogenesis of ARDS, including human studies, it has been reported that TNF-$\alpha$ is not sensitive and specific marker for impending ARDS. But there is a possibility that the results were affected by the diversity of pathogenetic mechanisms leading to the ARDS because of various underlying disorders of the study group in the previous reports. The purpose of the present study was to evaluate the roles of TNF-$\alpha$ and IL-$1{\beta}$ as a predictable marker for development of ARDS in the patients with septic syndrome, in which the pathogenesis is believed to be mainly cytokine-mediated. Methods: Thirty-six patients of the septic syndrome hospitalized in the intensive care units of the Asan Medical Center were studied. Sixteens suffered from ARDS, whereas the remaining 20 were at the risk of developing ARDS(acute hypoxemic respiratory failure, AHRF). In all patients venous blood samples were collected in heparin-coated tubes at the time of enrollment, at 24 and 72 h thereafter. TNF-$\alpha$ and IL-$1{\beta}$ was measured by an enzyme-linked immunosorbent assay (ELISA). All data are expressed as median with interquartile range. Results: 1) Plama TNF-$\alpha$ levels: Plasma TNF-$\beta$ levels were less than 10pg/mL, which is lowest detection value of the kit used in this study within the range of the $mean{\pm}2SD$, in all of the normal controls, 8 of 16 subjects of ARDS and in 8 in 20 subjects of AHRF. Plasma TNF-$\alpha$ levels from patients with ARDS were 10.26pg/mL(median; <10-16.99pg/mL, interquartile range) and not different from those of patients at AHRF(10.82, <10-20.38pg/mL). There was also no significant difference between pre-ARDS(<10, <10-15.32pg/mL) and ARDS(<10, <10-10.22pg/mL). TNF-$\alpha$ levels were significantly greater in the patients with shock than the patients without shock(12.53pg/mL vs. <10pg/mL) (p<0.01). There was no statistical significance between survivors(<10, <10-12.92pg/mL) and nonsurvivors(11.80, <10-20.8pg/mL) (P=0.28) in the plasma TNF-$\alpha$ levels. 2) Plasma IL-$1{\beta}$ levels: Plasma IL-$1{\beta}$ levels were less than 0.3ng/mL, which is the lowest detection value of the kit used in this study, in one of each patients group. There was no significant difference in IL-$1{\beta}$ levels of the ARDS(2.22, 1.37-8.01ng/mL) and of the AHRF(2.13, 0.83-5.29ng/mL). There was also no significant difference between pre-ARDS(2.53, <0.3-8.34ngfmL) and ARDS(5.35, 0.66-11.51ng/mL), and between patients with septic shock and patients without shock (2.51, 1.28-8.34 vs 1.46, 0.15-2.13ng/mL). Plasma IL-$1{\beta}$ levels were significantly different between survivors(1.37, 0.4-2.36ng/mL) and nonsurvivors(2.84, 1.46-8.34ng/mL). Conclusion: Plasma TNF-$\alpha$ and IL-$1{\beta}$ level are not a predictable marker for development of ARDS. But TNF-$\alpha$ is a marker for shock in septic syndrome. These result could not exclude a possibility of pathophysiologic roles of TNF-$\alpha$ and IL-$1{\beta}$ in acute lung injury because these cytokine could be locally produced and exert its effects within the lungs.

  • PDF

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

A Pilot Study for the Feasibility of F-18 FLT-PET in Locally Advanced Breast Cancer: Comparison with F-18 FDG-PET (국소진행성 유방암에서 F-18 FLT-PET 적용 가능성에 대한 예비 연구: F-18 FDG-PET와 비교)

  • Hyuen, Lee-Jai;Kim, Euy-Nyong;Hong, Il-Ki;Ahn, Jin-Hee;Kim, Sung-Bae;Ahn, Sei-Hyun;Gong, Gyung-Yup;Kim, Jae-Seung;Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.29-38
    • /
    • 2008
  • Purpose: The aim of this study was to investigate the feasibility of 3 ' -[F-18]fluoro-3 ' -deoxythymidine positron emission tomography(FLT-PET) for the detection of locally advanced breast cancer and to compare the degree of FLT and 2' -deoxy-2 ' -[F-18]fluoro-d-glucose(FDG) uptake in primary tumor, lymph nodes and other normal organs. Material & Methods: The study subjects consisted of 22 female patients (mean age; $42{\pm}6$ years) with biopsy-confirmed infiltrating ductal carcinoma between Aug 2005 and Nov 2006. We performed conventional imaging workup, FDG-PET and FLT PET/CT. Average tumor size measured by MRI was $7.2{\pm}3.4$ cm. With visual analysis, Tumor and Lymph node uptakes of FLT and FDG were determined by calculation of standardized uptake value (SUV) and tumor to background (TB) ratio. We compared FLT tumor uptake with FDG tumor uptake. We also investigated the correlation between FLT tumor uptake and FDG tumor uptake and the concordant rate with lymph node uptakes of FLT and FDG. FLT and FDG uptakes of bone marrow and liver were measured to compare the biodistribution of each other. Results: All tumor lesions were visually detected in both FLT-PET and FDG-PET. There was no significant correlation between maximal tumor size by MRI and SUVmax of FLT-PET or FDG-PET (p>0.05). SUVmax and $$SUV_{75} (average SUV within volume of interest using 75% isocontour) of FLT-PET were significantly lower than those of FDG-PET in primary tumor (SUVmax; $6.3{\pm}5.2\;vs\;8.3{\pm}4.9$, p=0.02 /$SUV_{75};\;5.3{\pm}4.3\;vs\;6.9{\pm}4.2$, p=0.02). There is significant moderate correlation between uptake of FLT and FDG in primary tumor (SUVmax; rho=0.450, p=0.04 / SUV75; rho=0.472, p=0.03). But, TB ratio of FLT-PET was higher than that of FDG-PET($11.7{\pm}7.7\;vs\;6.3{\pm}3.8$, p=0.001). The concordant rate between FLT and FDG uptake of lymph node was reasonably good (33/34). The FLT SUVs of liver and bone marrow were $4.2{\pm}1.2\;and\;8.3{\pm}4.9$. The FDG SUVs of liver and bone marrow were $1.8{\pm}0.4\;and\;1.6{\pm}0.4$. Conclusion: The uptakes of FLT were lower than those of FDG, but all patients of this study revealed good FLT uptakes of tumor and lymph node. Because FLT-PET revealed high TB ratio and concordant rate with lymph node uptakes of FDG-PET, FLT-PET could be a useful diagnostic tool in locally advanced breast cancer. But, physiological uptake and individual variation of FLT in bone marrow and liver will limit the diagnosis of bone and liver metastases.

Estimation of Productivity for Quercus variabilis Stand by Forest Environmental Factors (삼림환경인자(森林環境因子)에 의한 굴참나무임분(林分)의 생산력추정(生産力推定))

  • Lee, Dong Sup;Chung, Young Gwan
    • Journal of Korean Society of Forest Science
    • /
    • v.75 no.1
    • /
    • pp.1-18
    • /
    • 1986
  • This study was initiated to estimate productivity of Quercus variabilis stand. However the practical objective of this study was to provide some information to establish the basis of selecting the suitable site for Quercus variabilis. The productivity measured in terms of DBH, height, basal area and stem volume was hypothesized, respectively, to be a function of a group of factors. This study considered 32 factors, 20 of which were related to the forest environmental factors such as tree age, latitude, percent slope, etc. and the rest of which were related to soil factors such as soil moisture, total nitrogen, available $P_2O_5$, etc. The data on 4 productivity measurements of Quercus variabilis growth and related factors cited were collected from 99 sample plots in Kyeongbook and chungbook provinces. Some factors considered were, in nature, discrete variables and the others continuous variables. Each kind of factor was classified into 3 or 4 categories and total numbers of such categories were eventually amounted to 110. Then each category was treated as an independent variable. This is amounted to saying that individual variable was treated a dummy variable and assigned a value 1 or 0. However the first category of each factor was deleted from the normal equation for statistical consideration. First of all, each of 4 productivity measurements of Quercus variabilis growth was regressed and, at the same time, those 110 categories. Secondly, the partial correlation coefficients were measured between each pair of 4 productivity measurements and 32 individual foctors. Finally, the relative scores were estimated in order to derive the category ranges. The result of these statistical analyses could be summarized as follows: 1) Growth measurement in terms of height seems to be a more significant criterion for estimation of productivity of Quercus variabilis. 2) Productivity of forest on stocked land may better be estimated in terms of forest environmental factors, on the other hand, that of unstocked land may be estimated in terms of physio-chemical factors of soil. 3) The factors that a strongly positive relation to all growth factors of tree are age group, effective soil, soil moisture, etc. This implies that these factors might effectively be used for criteria for selecting the suitable site for Quercus variabilis. 4) Parent rock, latitude, total nitrogen, age group, effective soil depth, soil moisture, organic matter, etc., had more significant category range for tree growth. Therefore, the suitable site for Quercus variabilis may be selected, based on this information. In conclusion, the above results obtained by the multivariable analysis can be not only the important criteria for estimating the growth of Quercus variabilis but also the useful guidance for selecting the suitable sites and performing the rational of Quercus variabilis forest.

  • PDF

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF

Comparison of Treadmill and Cycle Ergometer in Male Korean College Students (한국 남자 대학생을 대상으로 시행한 Cardiopulmonary Exercise Test에서 Treadmill과 Cycle Ergometer의 비교 분석)

  • Chang, Yoon-Soo;Park, Jae-Min;Choi, Seung-Won;Ahn, Gang-Hyun;Lee, Jun-Gu;Yang, Dong-Kyu;Kim, Se-Kyu;Chang, Jun;Ahn, Chul-Min;Kim, Seong-Kyu;Lee, Won-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.26-34
    • /
    • 1999
  • Background : Generally $VO_2$ max is higher in treadmill exercise than cycle ergometer exercise. According to Hassen and Wasserman, $VO_2$ max with treadmill exercise is higher at ratio of 1.11 than that with cycle ergometer. $VO_2$ max also is influenced by race, sociocultural background, exercise habit In this study, $VO_2$ max and AT were evaluated between Treadmill and cycle exercise in male Korean college students. Method: Study subjects were 44 male college students. We randomized them into 2 groups; 24 students did treadmill exercise at first and 1 week later did cycle ergometer. Another 20 students did in opposite method. They made symptom limited maximal exercise. Author defined maximal exercise as followings: 1) respiratory exchange ratio(RER)> 1.1, 2) plateau>30 sec, 3) heart rate reserve(HRR) <15%, or 4) breathing reserve (BR)<30%. Otherwise their results are excluded as submaximal exercise. Anaerobic threshold(AT) was estimated by V-slope method. Results: $VO_2$ max and AT was $45.1{\pm}6.66m\ell$/kg/min and $26.0{\pm}6.78m\ell$/kg/min in treadmill and $34.9{\pm}5.89m\ell$/kg/min, $19.5{\pm}4.77m\ell$/kg/min in Cycle Ergometer. The measured-$VO_2max$/pred-$VO_2max$ was $98.8{\pm}13.24%$ in treadmill; $84.4{\pm}13.42%$ in cycle ergometer. Comparing $VO_2$ max in treadmill with that obtained by Hassen's method, there were significant differences.(p<0.01). At maximal exercise there were differences in HRR, $O_2$/pulse, BR, $V_E$/MVV, $V_E/VCO_2$ between treadmill and cycle but not in $V_E/VO_2$, Vd/Vt, Ti/Ttot. At AT there were differences in $O_2$/pulse, BR, $V_E$/MVV, Ti/Ttot between treadmill and cycle, otherwise not. Conclusion: According to the result of this study, there are larger gap between treadmill and cycle ergometer in normal Korean adults than foreign data, and it needs further study to obtain reference value of Korea.

  • PDF