• 제목/요약/키워드: normal transient

검색결과 372건 처리시간 0.036초

Experimental Identification of Input Power to the Plate Using the Transient Structural Intensity Map

  • Oey, Agustinus;Ih, Jeong-Guon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.110-112
    • /
    • 2009
  • Transient acoustic pressure in the near field of an impacted plate carries information that can be utilized for recovering the impact force history. The inverse calculation approach using BEM-based NAH, which is conventionally used for time harmonic excitation, can be applied for reconstructing the transient waves using the principle of Fourier transform and spectral analysis. Then, using the recovered velocity in normal direction of the plate surface, the corresponding structural intensity can be obtained and the identification of input power can be performed. However, several manipulations should be given to overcome numerical artifacts, such as aliasing and erratic oscillation at discontinuity, and to suppress the effect of noise. Experiment using a simply supported plate is presented for demonstration purpose.

  • PDF

보호용 CT의 과도 성능 검증에 관한 연구 (A Study on the Determination of the Transient Performance for Protective Current Transformer)

  • 김동수;박남옥;김철환;류재남
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1727-1732
    • /
    • 2010
  • The Current transformer is classified measuring CT and protective CT for their purpose. The measuring CT is required to retain a specified accuracy over the normal range of load currents, but the protective CT must be capable of providing an adequate output over wide range of fault condition. Therefore, the protective CT must determine the transient performance during fault condition. This paper measured peak instantaneous error of the TPY class CT to determine the transient performance directly and indirectly and studied the test results.

감압밸브를 사용한 탄광갱내 공조용 냉수 공급시스템의 과도현상 해석 (Simulation of Transient Flow in a Cold-Water Supply System with Pressure Reducing Valves for Cooling the Inside of a Coal Mining Pit)

  • 강신형;이택식;이상산
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.395-407
    • /
    • 1988
  • Transient flow in a cold-water supply system for cooling the inside of a coal mining pit was numerically simulated. Properly designed and presetted pressure reducing valves control the level of pressures of the piping system at normal or emergent conditions Quasi-steady relations to simulate the valve motion are obtained and the transient performance of the valve is investigated in the present paper. The present method reasonably simulate transient phenomena in the system including the pressure reducing valve. Excessive valve motion and column separation are simulated when the flow is abruptly reduced. A calculated example of the real system is also presented. The simulation can be used for the safety-check and the guidance for design and operation in emergent cases of the system.

  • PDF

The transient sputtering yield change of an amorphous Si layer by low energy $O_2^{+}$ and $Ar^{+}$ ion bombardment

  • Shin, Hye-Chung;Kang, Hee-Jae;Lee, Hyung-Ik;Moon, Dae-Won
    • 한국진공학회지
    • /
    • 제12권S1호
    • /
    • pp.92-94
    • /
    • 2003
  • The sputtering yield change of an amorphous Si layer on Si(100) was measured quantitatively for 0.5 keV $O_2^{+}$ and $Ar^{+}$ ion bombardment with in suit MEIS. In the case of 0.5 keV $O_2^{+}$ ion bombardment, at the initial stage of sputtering before surface oxidation, the sputtering yield of Si was 1.4 (Si atoms/$O_2^{+}$) and then decreased down to 0.06 at the ion dose of $3\times10^{16}O_2\;^{+}\textrm{/cm}^2$. In the case of 0.5 keV $Ar^{+}$ ion bombardment, the sputtering yield of Si for the surface normal incidence was 0.56 at the ion dose of 2.5 ${\times}$ 10$^{15}$ $Ar^{+}\textrm{cm}^2$, and rapidly saturated to 1.2 at dose of $7.5\times10^{15}Ar^+\textrm{cm}^2$. For the incidence angle of 80 from surface normal, the sputtering yield of Si was saturated to about 1.4 at the initial stage of sputtering. The surface transient effects, caused by change in sputtering yield at the initial stage of sputtering can be negligible when 0.5 keV $Ar^{+}$ ion at extremely grazing angle was used for sputter depth profiling.g.

Discrimination of Arcing Faults from Normal Distribution Disturbances by Wave form Distortion Analysis

  • Kim, C. J.
    • Journal of Electrical Engineering and information Science
    • /
    • 제1권2호
    • /
    • pp.52-57
    • /
    • 1996
  • Detection of arcing high impedance faults has been a perplexing in the power distribution protection. Transient analysis of distribution disturbances for fault discrimination from other normal events is important for a secure protection of the power system. A simple parameter of wave form distortion quantification is used to analyze the behaviors of arcing faults and normal distribution disturbances. Theoretical perspectives of the transients were studied and actual disturbances were examined. From this investigation, a discrimination guideline based on the revised crest factor is developed. The discrimination method has a high potential to enhance the reliability and security for the distribution system protection.

  • PDF

상변위에 의한 동기전동기의 과도안정도 개선 (Improvement of Synchronous Motor Transient Stability by Phase Slipping)

  • 한송엽
    • 전기의세계
    • /
    • 제21권2호
    • /
    • pp.20-24
    • /
    • 1972
  • The transient stability of the synchronous motor is generally improved by damper winding or flywheel. However the synchronous motor at full load will be pulled out from normal operation state when the period of power failure exceeds approximately ten cycle per second. This paper studies the method of improving the stability of synchronous motor by equipping the phase slipping switch between the motor and power source. This paper shows the motor does not pull out, which results from the decrease of power angle to about 30 electrical degrees by means of the switch even when the relatively long period of power failure brings the power angle to some 150 electrical degrees.

  • PDF

Intramolecular Proton Transfers of 2-hydroxy-4,5-naphthotropone

  • Du-Jeon Jang
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권4호
    • /
    • pp.441-444
    • /
    • 1991
  • The intramolecular proton transfers of 2-hydroxy-4,5-naphthotropone in room temperature solutions are studied using static and time-resolved absorption and emission spectroscopy. Dual normal and tautomer fluorescence is observed in ethanol solution, while only the tautomer fluorescence is observed in cyclohexane solution. The fluorescence lifetimes and quantum yields in ethanol and cyclohexane solutions indicate that in hydrocarbon solvents, rapid intersystem crossing competes with proton transfer in the first excited singlet state. Transient absorption spectra and kinetics indicate that proton transfer also undergoes in the first triplet state with a transfer time of ∼ 3 ns. No transient absorption from the tautomer ground state indicates a rapid back proton transfer in the ground state.

Transient Response of a Permeable Crack Normal to a Piezoelectric-elastic Interface: Anti-plane Problem

  • Kwon, Soon-Man;Lee, Kang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • 제18권9호
    • /
    • pp.1500-1511
    • /
    • 2004
  • In this paper, the anti-plane transient response of a central crack normal to the interface between a piezoelectric ceramics and two same elastic materials is considered. The assumed crack surfaces are permeable. By virtue of integral transform methods, the electro elastic mixed boundary problems are formulated as two set of dual integral equations, which, in turn, are reduced to a Fredholm integral equation of the second kind in the Laplace transform domain. Time domain solutions are obtained by inverting Laplace domain solutions using a numerical scheme. Numerical values on the quasi-static stress intensity factor and the dynamic energy release rate are presented to show the dependences upon the geometry, material combination, electromechanical coupling coefficient and electric field.

Effect of the laser pulse on transient waves in a non-local thermoelastic medium under Green-Naghdi theory

  • Sarkar, Nantu;Mondal, Sudip;Othman, Mohamed I.A.
    • Structural Engineering and Mechanics
    • /
    • 제74권4호
    • /
    • pp.471-479
    • /
    • 2020
  • This paper aims to study the effect of the elastic nonlocality on the transient waves in a two-dimensional thermoelastic medium influenced by thermal loading due to the laser pulse. The bounding plane surface is heated by a non-Gaussian laser beam. The problem is discussed under the Eringen's nonlocal elasticity model and the Green-Naghdi (G-N) theory with and without energy dissipation. The normal mode analysis method is used to get the exact expressions for the physical quantities which illustrated graphically by comparison and discussion. The effects of nonlocality and different values of time on the displacement, the stresses, and the temperature were made numerically. All the computed results obtained have been depicted graphically and explained.

탄성기반에서 과도 열탄성 접촉에 대한 열 접촉 저항의 영향 (Effect of Thermal Contact Resistance on Transient Thermoelastic Contact for an Elastic Foundation)

  • 장용훈;이승욱
    • 대한기계학회논문집A
    • /
    • 제30권7호
    • /
    • pp.833-840
    • /
    • 2006
  • The paper presents a numerical solution to the problem of a hot rigid indenter sliding over a thermoelastic Winkler foundation with a thermal contact resistance at constant speed. It is shown analytically that no steady-state solution can exist for sufficiently high temperature or sufficiently small normal load or speed, regardless of the thermal contact resistance. However the steady state solution may exist in the same situation if the thermal contact resistance is considered. This means that the effect of the large values of temperature difference and small value of force or velocity which occur at no steady state can be lessened due to the thermal contact resistance. When there is no steady state, the predicted transient behavior involves regions of transient stationary contact interspersed with regions of separation regardless of the thermal contact resistance. Initially, the system typically exhibits a small number of relatively large contact and separation regions, but after the initial transient, the trailing edge of the contact area is only established and the leading edge loses contact, reducing the total extent of contact considerably. As time progresses, larger and larger numbers of small contact areas are established, unlit eventually the accuracy of the algorithm is limited by the discretization used.