• Title/Summary/Keyword: normal plate

Search Result 690, Processing Time 0.026 seconds

Source Parameters of Two Moderate Earthquakes at the Yellow Sea Area in the Korean Peninsula on March 22 and 30, 2003 (한반도 황해 해역에서 발생한 2003년 3월 23일, 3월 30일 중규모 지진의 지진원 상수)

  • Choi, Ho-Seon
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.235-242
    • /
    • 2010
  • Two moderate earthquakes with local magnitude 4.9 and 5.0 at the Yellow Sea area occurred successively around Hong island on March 22, 2003 and Baengnyeong island on March 30, 2003, respectively, close to the Korean Peninsula. Focal mechanisms by the waveform inversion analysis are strike slip faulting with a thrust component for the March 22 event, and normal faulting for the March 30 event. The direction of P-axes of two events were ENE-WSW which were similar to previous studies on that of P-axes in and around the Korean Peninsula. Moment magnitudes determined by the waveform inversion analysis were 4.7 and 4.5, respectively, whereas those determined by spectral analysis were 4.8 and 4.6, respectively. As regards the March 22 event, regional stress by combined tectonic forces from compressions of plates colliding to the Eurasian plate, rather than mere local stress, was indicated. However, it was estimated that the March 30 event took place when the weak zone generated from the existing collision zone was reactivated when subjected to local stress in the tensile direction. This seismological observation indirectly supports the idea that the collision zone may extend to the Korean Peninsula.

High-resolution Seismic Imaging of Shallow Geology Offshore of the Korean Peninsula: Offshore Uljin (신기 지구조운동의 해석을 위한 한반도 근해 천부지질의 고해상 탄성파 탐사: 울진 주변해역)

  • Kim, Han-Joon;Jou, Hyeong-Tae;Yoo, Hai-Soo;Kim, Kwang-Hee;You, Lee-Sun
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.2
    • /
    • pp.127-132
    • /
    • 2011
  • We acquired and interpreted more than 650 km of high-resolution seismic reflection profiles in the Hupo Basin, offshore east coast of Korea at $37^{\circ}N$ in the East Sea (Japan Sea) to image shallow and basement deformation. The seismic profiles reveal that the main depocenter of the Hupo Basin in the study area is bounded by the large offset Hupo Fault on the east and an antithetic fault on the west; however, the antithetic fault is much smaller both in horizontal extension and in vertical displacement than the Hupo Fault. Sediment infill in the Hupo Basin consists of syn-rift (late Oligocene. early Miocene) and post-rift (middle Miocene.Holocene) units. The Hupo Fault and other faults newly defined in the Hupo Basin strike dominantly north and show a sense of normal displacement. Considering that the East Sea has been subjected to compression since the middle Miocene, we interpret that these normal faults were created during continental rifting in late Oligocene to early Miocene times. We suggest that the current ENE direction of maximum principal compressive stress observed in and around the Korean peninsula associated with the motion of the Amurian Plate induces the faults in the Hupo Basin to have reverse and right-lateral, strike-slip motion, when reactivated. A recent earthquake positioned on the Hupo Fault indicates that in the study area and possibly further in the eastern Korean margin, earthquakes would occur on the faults created during continental rifting in the Tertiary.

Shear Behavior of Sands Depending on Shear Box Type in Direct Shear Test (직접전단실험시 전단상자의 종류에 따른 모래시료의 전단거동)

  • Hong, Young-Ho;Byun, Yong-Hoon;Chae, Jong-Gil;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.3
    • /
    • pp.51-62
    • /
    • 2015
  • Shear behavior obtained by direct shear tests is dependent on shear box and boundary condition. The objective of this study is to analyze problems of conventional direct shear test (type-A) and provide the reliable results by developing type-C direct shear apparatus. Experimental tests are carried out for Ulleung sand by using type-A and -C direct shear devices. The soil specimens, which are prepared at the relative density of 60%, and are applied to vertical confining stresses of 50, 100, 200, 300, and 400 kPa, are sheared at a constant shear strain rate of 0.5 mm/min. By comparing the results obtained by type-A and -C direct shear apparatus under constant normal load (CNL) condition, the performance of new one is verified. In addition, two constrained conditions including constant normal load (CNL) and constant pressure (CP) are applied to type-C one. Experimental results show that type-A direct shear apparatus has some problems such as rotating of loading plate and upper shear box, and the frictional forces between soil and inner wall of upper shear box. Thus, the shear strengths obtained by type-A device are overestimated or underestimated depending on shear box and boundary condition. On the other hand, type-C device produces clear and consistent test results regardless of constrained conditions. This study represents that type-C direct shear apparatus not only can solve the problems of type-A direct shear apparatus but provide the reliable results.

Experimental Effects of Mahwangkanghwal-tang(Mahuangqianghuo-tang) on the Adjuvant Arthritis in Rats (마황강활탕(麻黃羌活湯)이 Adjuvant 관절염에 미치는 실험적 효과)

  • Sul, Jae-Uk;Shin, Mi-Suk;Choi, Jin-Bong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.15 no.2
    • /
    • pp.55-65
    • /
    • 2005
  • Objectives : Mahwangkanghwal-tang(Mahuangqianghuo-tang;MKT) is a prescription that treat clinically arthritis. The purpose of this study is to investigate effects of MKT extract on the adjuvant arthritis in pathological rats induced by Freund's complete adjvant($0.2m{\ell}/kg$). Methods : Experimental groups were divided into 4 groups ; Normal group were administered DDW $1.0m{\ell}$ to normal rats for 14 days, Control group were administered DDW $1.0m{\ell}$ to arthritic rats for 14 days, Sample A group were administered MKT $300m{\ell}/kg$ $1.0m{\ell}$ to arthritic rats for 14 days, Sample B group were administered MKT $500m{\ell}/kg$ $1.0m{\ell}$ to arthritic rats for 14 days. The present author observed body weight, inhibitory effect of edema, analgesic effects by hot plate, WBC, RBC, hemoglobin, hematocrit, platelet, total serum protein level and total serum cholesterol level. Results : 1. All sample group were increased body weight compared with control group, sample B group were significantly increased body weighty compared with control group. 2. All sample group significantly inhibited the rated of paw edema compared with control group. 3. All sample group significantly prolongated the escaping time compared with control group, sample B group significantly prolongated the paw licking time compared with control group. 4. All sample group were significantly decreased WBC compared with control group, sample B group were significantly decreased RBC compared with control group. 5. All sample group ware decreased hemoglobin and hematocrit compared with control group. 6. All sample group ware increased total serum cholesterol compared with control group, sample B group were significantly decreased platelet compared with control group. 7. All sample group ware significantly decreased total serum protein level compared with control group. 8. All sample group ware increased total serum cholesterol compared with control group, sample B group were significantly increased total serum cholesterol level compared with control group. Conclusions : We thought that Mahwangkanghwal-tang(Mahuangqianghuo-tang) could be used for curing rheumatoid arthritis, anti-inflammatory effect was somewhat better in much than small dosage.

Grid Tests for Large Eddy Simulation of Transitional Flows around Turbulence Stimulators (난류 촉진기 주위 천이 유동의 대형 와 모사를 위한 격자 테스트)

  • Lee, Sang Bong;Park, Dong Woo;Paik, Kwang-Jun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.1
    • /
    • pp.112-121
    • /
    • 2017
  • Large eddy simulations of transitional flows around a stud installed on a flat plate have been performed to investigate an influence of grid resolution on turbulence stimulation by the stud. Because streamwise vortical structures generated by the stud played an important role in turbulence stimulation of boundary layer, streamwise vorticity was compared in the wake region behind the stud when the number of grids increased or decreased by a ratio of ${\sqrt{2}}$ in streamwise, wall-normal and spanwise directions respectively. The streamwise vorticity was shown to be mainly affected by spanwise grid resolution (${\Delta}z^+$) rather than streamwise and wall-normal grid resolution. In a viewpoint of numerical efficiency as well as physical resolution, ${\Delta}x^+{_{min}}=7.6$, ${\Delta}x^+{_{max}}=41$, ${\Delta}y^+{_{wall}}=0.25$ and ${\Delta}z^+=7.6$ was found to be desirable. Once a grid resolution was determined in each direction, a grid verification was carried out by increasing or decreasing the grid resolution y a ratio of ${\sqrt{2}}$ in all directions. The grid uncertainties of pressure and drag coefficients were 21.6 % and 2.8 % while the corrected uncertainties were 2 % and 0.3 %, respectively.

3-D Free Vibration Analysis of Exponential and Power-law Functionally Graded Material(FGM) Plates (지수 및 멱 법칙 점진기능재료 판의 3차원 자유진동해석)

  • Lee, Won-Hong;Han, Sung-Cheon;Ahn, Jin-Hee;Park, Weon-Tae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.553-561
    • /
    • 2015
  • The exponential and power law functionally graded material(FGM) theory is reformulated considering the refined shear and normal deformation theory. This theory has ability to capture the both normal deformation effect and exponential and power law function in terms of the volume fraction of the constituents for material properties through the plate thickness. Navier's method has been used to solve the governing equations for all edges simply supported plates on Pasternak elastic foundation. Numerical solutions of vibration analysis of FGM plates are presented using this theory to illustrate the effects of power law index and 3-D theory of exponential and power law function on natural frequency. The relations between 3-D and 2-D higher-order shear deformation theory are discussed by numerical results. Further, effects of (i) power law index, (ii) side-to-thickness ratio, and (iii) elastic foundation parameter on nondimensional natural frequency are studied. To validate the present solutions, the reference solutions are discussed.

Petrology of the Volcanic Rocks in Geoje Island, South Korea (거제도 화산암의 암석학적 연구)

  • 윤성효;이준동;이상원;고정선;서윤지
    • The Journal of the Petrological Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.1-18
    • /
    • 1997
  • Andesitic pyroclastics and lava flows are deposited as a part of composite volcanoes by Cretaceous volcanic activity in Geojae Island, off the coast of Korea. The andesitic pyroclastics are composed of tuff breccia and lapilli tuff minor intercalated tuff. Lava flows are divided into dense and porphyritic andesite containing phenocrysts of plagioclase, pyroxene, and/or hornblende. The andesitic rocks represent charactersitcs of carc-alkaline BAR association with basalt, basaltic andesite, andesite, and dacite to rhyolite. Major element variations of the volcanic rocks show that $Al_2O_3$, total FeO, CaO, MgO and $TiO_2$ decrease with increasing $SiO_2$ but $K_2O$ and total alkalis increase, and represent differntiation trend of calc-alkaline rock series. In spider diagram, contents of Sr, K, Rb, Ba, and Th are relatively high, but contents of Nb, P, Ti and Cr are low. These petrochemcial characteristics are similar to those of rocks from island arc or continental margein related to plate subduction. Chondrite-normalized REE patterns of volcanic rocks are paralle to subparallel, with LREE enriched than HREE, and show gradual increase of negative Eu anomaly from basalt to dacite and rhyolite, suggesting comagmatic fractional crystallization with minor effects of assimilation and magma mixing. Andesitic rocks are assumed medium-K orogenic andesites that formed in the tectomagmatic environment of subduction zone under normal continental margin arc.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

Synthetic Hydrogel as an Implant Material with Enhanced Biocompatibility and Biostability (생체적합성 및 생체안정성이 향상된 이식용 합성 수화젤)

  • 최진현;박보형;한영아;김수정;임정옥
    • Polymer(Korea)
    • /
    • v.28 no.1
    • /
    • pp.86-91
    • /
    • 2004
  • Hydrogels with enhanced biocompatibility and biostability were prepared by copolymerization of 2-hydroxyethyl methacrylate (HEMA) and sodium methacrylate (SMA) at high monomer concentration to replace a sponge which has limited applications as an implant material. It was found that incorporation of SMA moiety suppressed cytotoxicity. P(HEMA-co-SMA) hydrogel prepared at SMA feed ratio of 0.05 showed minimal cytotoxicity as compared with a normal cell culture plate. The adhesion and the spreading of cells were preferred on the surface of the hydrogel prepared with SMA feed ratio of 0.01. On the other hand, the hydrogel prepared with SMA feed ratio of 0.05 showed lower cell adhesion. Histological findings revealed no evidence of significant foreign body reaction in the tissues around the copolymer hydrogels. Conclusively, it is suggested that the hydrogels prepared by copolymerization of HEMA and SMA at high monomer concentration are strong candidates for an implant material with excellent biocompatibility and biostability.

Portland-Blended Cement with Reduced CO2 using Trass Pozzolan (화산회 가루를 사용함에 의한 CO2-저방출 포트랜드-혼합 시멘트 제조)

  • Manaf, A.;Indrawati, V.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.3
    • /
    • pp.490-494
    • /
    • 2011
  • This paper reports the use of supplementary cementing materials (SCMs) derived from local resources, for the partial replacement of Portland cement to reduce $CO_2$ emission during cement production. Replacement of Portland clinkers up to 20 wt.% with SCMs in normal cements reduced $CO_2$ emission by 0.18 kg $CO_2$/kg. The compressive strength exceeded the standard specification for Portland cement ASTM C-150. Blended cement samples containing 20% Portland clinker replacement had compressive strengths of 37 MPa after 28 days of curing time. The microstructure evolution of blended cement at a composition of 80:20 was similar to that of the 100% Portland cement, where the structure between days 28 and 56 reached a steady state. Blended cements with compositions of 70:30 and 60:40 still showed progress of CSH plate formation and the lack of massive structure development. It is shown that the use of supplementary cementing materials could be as one of alternative ways to reduce $CO_2$ emissions during cement production.