• Title/Summary/Keyword: normal measurement

Search Result 1,801, Processing Time 0.029 seconds

The Comparison Between Blind and Normal Children in Standing Position (시각장애 아동과 정상 아동의 선자세 균형 비교)

  • Kim Chung-sun;Lee Jeong-soon
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.119-154
    • /
    • 2003
  • In this paper, the proprioceptive sensitivity was compared by Foot-Hand task method and the effect of the proprioceptive sensitivity and auditory to the standing position between blind and normal children was measured using BPM for 56 children in 7, 8, 9 and 10 years old. There are three measurement methods are used for BPM : Rest, Forward Looking, 'Sound' position. The following conclusions were obtained from the above measurements. 1. In comparison of proprioceptive sensitivity between blind and normal children, there is no significant difference(p > .05). There is no significant difference in comparison of each age group and also there is no difference in each gender group(p > .05). 2. In comparison of standing position measurement between blind and normal children, there is any difference (p > .05) in three measurement(Rest, Forward Looking, 'Sound' position) but there is no significant difference in each gender difference(p > .05). There is any difference between Rest and 'Sound' position of blind children, also there is any difference between Forward Looking and ' Sound ' position, rest and 'Sound' position of normal children(p > .05). 3. There is no significant difference of correlation between proprioceptive sensitivity test and standing position measurement in Pearson correlation coefficient(p > .05).

  • PDF

Measurement of the radon and thoron exhalation rates from the water surface of Yixin lake

  • Jiulin Wu;Shuaibin Liu;Tao Hu;Fen Lin;Ruomei Xie;Shuai Yuan;Haibo Yi;Yixiang Mo;Jiale Sun;Linquan Cheng;Huiying Li;Zhipeng Liu;Zhongkai Fan;Yanliang Tan
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1538-1543
    • /
    • 2024
  • The importance of determining the radon exhalation rate from water surface is emphasized by the increased use of radon and its daughter products as tracers in large-scale circulation studies of the atmosphere. There were many methods to measure radon exhalation from water surface. With the development of radon exhalation rate measurement methods and instruments on the surface of the soil, the rock and building materials, so the radon exhalation rate from water surface can be more accurately measured by applying these improved methods and instruments. In this paper, a cuboid accumulation chamber surrounded by foam boards and a RAD7 were used to measure the radon exhalation rate on the water surface at three different positions by Yixin lake. Each measurement was performed 2 h. The radon exhalation rate from the water surface was about 6 × 10-3 Bq m-2s-1. The thoron exhalation rate from the water surface also can be estimated, it is about 0.16 Bq m-2s-1. These results hint that the radon transmission from the lake bottom soil to water and then into the atmosphere.

Oscillator Strength of Normal-incidence Intersubband Absorption in Conduction Bands of Si and Ge Quantum Wells Using Polarization

  • Lee, Chanho
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.1
    • /
    • pp.80-85
    • /
    • 1998
  • A theoretical calculation and an optical measurement method of normal-incidence absorption are proposed. By using a waveguide structure, optical interference and the problem of low level signal can be avoided in the measurement of normal-incidence absorption. The oscillator strength of intersubband absorption for a waveguide structure is calculated in Si(001), Si(110), and Ge(001) quantum wells. The polarization angle dependence of the measured and the calculated absorption strength can be obtained with the same waveguide structure, and be compared after normalization. The normal-incidence absorption in Si(110) and Ge(001) quantum wells is shown theoretically, and can be observed in the optical measurement using waveguide structures at the polarization angle of 90$^{\circ}$.

  • PDF

Measurement Error Model with Skewed Normal Distribution (왜도정규분포 기반의 측정오차모형)

  • Heo, Tae-Young;Choi, Jungsoon;Park, Man Sik
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.6
    • /
    • pp.953-958
    • /
    • 2013
  • This study suggests a measurement error model based on skewed normal distribution instead of normal distribution to identify slope parameter properties in a simple liner regression model. We prove that the slope parameter in a simple linear regression model is underestimated.

Bootstrap Confidence Intervals of Precision-to-Tolerance Ratio (PTR의 붓스트랩 신뢰구간)

  • Chang, Mu-Seong;Kim, Sang-Boo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.30 no.2
    • /
    • pp.37-43
    • /
    • 2007
  • ANOVA is widely used for measurement system analysis. It assumes that the measurement error is normally distributed, which may not be seen in certain industrial cases. In this study, the exact and bootstrap confidence intervals for precision-to-tolerance ratio (PTR) are obtained for the cases where the measurement errors are normally and non-normally distributed and the reproducibility variation can be ignored. Lognormal and gamma distributions are considered for non-normal measurement errors. It is assumed that the quality characteristics have the same distributions of the measurement errors. Three different bootstrap methods of SB (Standard Bootstrap), PB (Percentile Bootstrap), and BCPB (Biased-Corrected Percentile Bootstrap) are used to obtain bootstrap confidence intervals for PTR. Based on a coverage proportion of PTR, a comparative study of exact and bootstrap methods is performed. Simulation results show that, for non-normal measurement error cases, the bootstrap methods of SB and BCPB are superior to the exact one.

Measurement of Normal Spring Constant of Colloidal Probes for Atomic Force Microscope (원자 현미경용 콜로이드 탐침 수직 스프링 상수 측정)

  • Kim, Dae-Hyun;Kim, Min-Seok;Hahn, Junhee;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.28 no.5
    • /
    • pp.212-217
    • /
    • 2012
  • A modified thermal noise method was proposed to measure the normal spring constants of the colloidal probes for an atomic force microscope. We used commercial tipless cantilevers (length 150, width 30, nominal k 7.4 N/m) and borosilicate spheres with a diameter of 20 to fabricate colloidal probes. The inverse optical lever sensitivity of both the tipless cantilever and colloidal probes were used to measure the normal spring constant of the colloidal probes. We confirmed the accuracy and usefulness of our method by comparing the measurement results with those obtained using the nanoforce calibrator (NFC), which reportedly has an uncertainty of 1.00%. The modified thermal method showed a good agreement (~10% difference) with the NFC, allowing us to conclude that the modified thermal method could be employed for the effective measurement of the normal spring constants of colloidal probes.

A STUDY ON USEFULNESS OF THE REFERENCE LINE IN DIAGNOSIS OF THE FACIAL ASYMMETRY (안모비대칭의 진단용 기준선의 유용성에 관한 연구)

  • Ryu, Sung-Ho;Chang, Hyun-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.266-273
    • /
    • 2005
  • Purpose: To assess the relationship between soft tissue reference line and hard tissue reference line using the standardized photographs and the posteroanterior cephalometric radiographs(P-A)in facial asymmetric patients and to compare the differences of angular measurement between normal group and asymmetry group. Methods: Normal group consisted of 44 persons with normal occlusion and normal facial morphology. Asymmetry group consisted of 90 patients with facial asymmetry. Standardized facial photographs and P-A were taken in all subjects. The horizontal reference lines were bipupillary line in photographs and latero-orbitale line in P-A respectively. The vertical reference line were the line from the midpoint of horizontal reference line perpendicularly. Angular measurement of otobasion canting, lip canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in photographs. And angular measurement of mastoid canting, mandibular canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in P-A. Results: 1. The variables of photographs and P-A were significantly related in the asymmetry group. 2. Significant differences between all variables except for PT2 and PA2 were shown in the asymmetry group and between PT1 and PA1, PT3 and PA3 in the normal group respectively. 3. Comparison measurement scores of angular difference between control group and experimental group concerning each variable showed significant difference except for PA1. Conclusions: Soft tissue components may not compensate for underlying skeletal imbalance in nose deviation and chin deviation. The horizontal reference lines in photographs were significant related with the P-A, but angular variables between the two studies show significant differences. Therefore, we do not recommend use photography in the assessment the facial asymmetry as complemented in the P-A.

Test-retest Reliability of Balance Tests in Older Adults (노인들에 대한 균형검사의 검사-재검사 신뢰도)

  • Kang, Soon-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.4
    • /
    • pp.49-57
    • /
    • 2009
  • Background: The purpose of this study was to assess the test-retest reliability of balance measurements in older adults using balance measurement system(Good Balance). Methods: The subjects consisted of 49 female and 20 male in community-dwelling older adults. This study used a repeated-measure design. Each subject completed all the different tests once and they were then repeated with 2 minutes in between. Repeated two-ways analysis of variance(ANOVA), representing two test times and both sexes, was calculated for each of the two dependent variables. Intraclass correlation coefficients(ICCs) were used to assess the test-retest reliability. Results: 1) There was not significant difference between test and retest for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There was not significant difference between males and females for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There were not the interaction effects between genders and test time under three conditions. 2) The reproducibility between test and retest was excellent for anterioposterior sway speed(ICC=.77) under condition of normal standing with eyes open, and for mediolateral sway speed(ICC=.76) and anterioposterior sway speed(ICC=.84) under condition of semitandem standing with eyes open. The reproducibility between test and retest was fair to good for mediolateral sway speed(ICC=.64) under condition of normal standing with eyes open, for mediolateral sway speed(ICC=.63) and anterioposterior sway speed(ICC=.75) under condition of normal standing with eyes closed. Conclusion: Balance tests in older adults using balance measurement system(Good Balance) demonstrated acceptable levels of reliability.

  • PDF

Comparison of Distance of Subacromial Space Using Ultrasonographic Measurement on Arm Positions of Shoulder Injured Patients (견부손상환자의 팔의 자세에 따른 초음파 영상을 이용한 견봉하공간 거리의 비교)

  • Jee, Eun-Mi;Kim, Suhn-Yeop;Park, Ji-Whan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.397-406
    • /
    • 2011
  • Purpose : Recently ultrasound images has been used to measure the subacromial space with a linear measurement of the acromiohumeral distance. The purpose of this study was to comparison of distance of subacromial space using ultrasonographic measurement on arm positions of shoulder injured patients. Methods : The subjects were 30 shoulder injured patients (19 males and 11 females). Ultrasonography was performed to measure subacromial space during each shoulder resting position, $45^{\circ}$ abduction, internal rotation with $45^{\circ}$ abduction and external rotation with $45^{\circ}$ abduction. Results : Subacromial space was a significantly difference between injured arm and normal arm at shoulder resting position. At $45^{\circ}$ abduction, subacromial space was narrowing significantly between injured arm and normal arm. At external rotation with $45^{\circ}$ abduction, subacromial space were wider in normal arm than in injured arm but it was not significantly. Intra-observer reliability for ultrasonography measurement of subacromial distance was excellent (.96~.99). Conclusion : These results identified that positions of injured shoulder was related to subacromion space.

Relationship between Normal Measurement and Error Rate of Output Voltage Linear Ratio of Seismic Accelerometer in Use (사용 중 지진 가속도계의 정상 측정과 출력전압 선형비 오차율 관계 분석)

  • Min-Jun Kim;Seong-Cheol Cho;Yong-Hun Jung;Jeong-Hun Won
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.65-74
    • /
    • 2024
  • We analyzed the relationship between the normal measurement of the seismic accelerometer (SA) and the error rate of the output voltage linear ratio to propose an evaluation method to determine whether the SA in use is measuring normally. Utilizing a test bed, the regular operation of SA in use was evaluated using acceleration data measured through impact tests since there are no regulations regarding performance testing of SA in use. For the used SA, the error rate of the output voltage linear ratio, which is a major performance criterion, was evaluated. We analyzed common characteristics of the SA that satisfied the impact test and the performance criteria of the output voltage linear ratio error rate. The results indicated that we must consider the decreasing trend and convergence of the error rate as the measurement angle increases, ensuring that the average value of the output voltage linear ratio error rate is within 1%.