• Title/Summary/Keyword: normal adhesion

Search Result 250, Processing Time 0.028 seconds

Adhesion of clay to metal surface; Normal and tangential measurement

  • Basmenj, Amir Khabbazi;Ghafoori, Mohammad;Cheshomi, Akbar;Azandariani, Younes Karami
    • Geomechanics and Engineering
    • /
    • v.10 no.2
    • /
    • pp.125-135
    • /
    • 2016
  • Adhesion in geotechnical engineering is the interaction between cohesive soil and a solid surface which can cause clogging in mechanized tunnelling through clayey formations. Normal piston pull out and modified direct shear tests were performed on clayey soil samples to determine which type of adhesion stress, normal or tangential, could be most effectively measured. Measured values for normal adhesion ranged from 0.9 to 18 kPa. The range of tangential adhesion was 2.4 to 10 kPa. The results indicate normal adhesion results were more accurate than those for the modified direct shear test that measure tangential adhesion. Direct shear test on identical samples did not show any correlation between measured cohesion and normal adhesion values. Normal adhesion values have shown significantly meaningful variation with consistency index and so are compatible with the base of field clogging assessment criteria. But tangential adhesion and cohesion were not compatible with these assessment criteria.

Nanotribological characteristics of silicon surfaces modified by IBAD (IBAD로 표면개질된 실리콘표면의 나노 트라이볼로지적 특성)

  • 윤의성;박지현;양승호;공호성;장경영
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.127-134
    • /
    • 2001
  • Nano adhesion and friction between a Sj$_3$N$_4$ AFM tip and thin silver films were experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM(atomic force microscope) and LFM(lateral force microscope) modes in various ranges of normal load. Thin silver films deposited by IBAD (ion beam assisted deposition) on Si-wafer (100) and Si-wafer of different surface roughness were used. Results showed that nano adhesion and friction decreased as the surface roughness increased. When the Si surfaces were coated by pure silver, the adhesion and friction decreased. But the adhesion and friction were not affected by the thickness of IBAD silver coating. As the normal force increased, the adhesion forces of bare Si-wafer and IBAD silver coating film remained constant, but the friction forces increased linearly. Test results suggested that the friction was mainly governed by the adhesion as long as the normal load was low.

  • PDF

Effect of Ferulic Acid on Cell Viability and Cell Adhesion Activity in Normal Human Gingival Fibroblasts

  • Lee Joo-Hyun;Jin Byung-Jo;Son Il-Hong;Han Du-Seok
    • Biomedical Science Letters
    • /
    • v.10 no.3
    • /
    • pp.269-273
    • /
    • 2004
  • This study was designed to investigate the effect of ferulic acid on cell viability and cell adhesion activity in normal human gingival fibroblasts. The cell viability and cell adhesion activity of ferulic acid was measured by MTT assay or XTT assay, respectively, after normal human gingival fibroblasts were treated with or without ferulic acid for 48 hours. The cell viability of ferolic acid on normal human gingival fibroblasts did not show any decreasement by MTT assay and also, cell adhesion activity did not decreased by XTT assay, respectively, compared with control after cells were treated with various concentrations of ferolic acid for 48 hours. MTT/sub 50/ and XTT/sub 50/ were 2,130.0 μM and 1,773.7 μM ferolic acid, respectively. These results suggest that ferolic acid is non-toxic to normal human gingival fibroblasts by showing no significant differences in the cell viability and the adhesion activity compared with control by colorimetric assay.

  • PDF

Nano-scale adhesion and friction on Si wafer with the tip size using AFM

  • R. Arvind Singh;Yoon, Eui-Sung;Oh, Hyun-Jin;Kong, Ho-Sung
    • KSTLE International Journal
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • Nano-scale studies on adhesion and friction were conducted in Si-wafer (100) using Atomic Force Microscopy (AFM). Glass (Borosilicate) balls of radii 0.32$\mu\textrm{m}$, 1.25$\mu\textrm{m}$, and 2.5$\mu\textrm{m}$, mounted on cantilever (Contact Mode type NPS) were used as tips. Adhesion and friction between Si-wafer and glass tips were measured at ambient temperature (24${\pm}$1$^{\circ}C$) and humidity (45${\pm}$5%). Friction was measured as a function of applied normal load in the range of 0-160 nN. Results showed that, both adhesion and friction increased with the tip radii. Also, friction increased linearly as a function of applied normal load. The effect of tip size on adhesion and friction was explained as the influence of the capillary force exerted by meniscus and that of the contact area on these parameters respectively. The coefficient of friction was estimated in two different ways, as the slope from the plot of friction force against the applied normal load and as the ratio between the friction force and the applied normal load. Both these estimates showed that the coefficient of friction increased with the tip size. Further, the influence of the adhesion force on the coefficient of friction was also discussed.

Nanotribological Characteristics of Silicon Surfaces Modified by IBAD (IBAD로 표면개질된 실리콘 표면의 나노 트라이볼로지적 특성)

  • Park, Ji-Hyun;Yang, Seung-Ho;Kong, Ho-Seung;Jhang, Kyung-Young;Yoon, Eui-Sung
    • Tribology and Lubricants
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Nano adhesion and friction between a $Si_{3}N_{4}$ AFM(atomic force microscope) tip and thin silver films were experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM and LFM(lateral force microscope) modes in various range of normal loads. Thin silver films deposited by IBAD (ion beam assisted deposition) on Si-wafer (100) and other Si-wafers of different surface roughness were used. Results showed that nano adhesion and friction decreased with the surface roughness. When the Si surfaces were coated by pure silver, the adhesion and friction decreased. But the adhesion and friction were not affected by the thickness of IBAD silver coating. As the normal force increased, the adhesion forces of bare Si-wafer and IBAD silver coating film remained constant, but the friction forces increased linearly. Test results suggested that the friction was mainly governed by the adhesion as long as the load was low.

Analysis of Nano-Tribophysics (Nano-Tribophysics 해석 기술)

  • 최덕현;황운봉
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.215-218
    • /
    • 2003
  • Nano-scale experiments for adhesion force and friction force were performed with AFM/FFM. In macro-scale, the friction coefficient is constant without relating to the change of contact area. However, many papers have indicated that in nano-scale, the friction coefficient is related to the contact area. Contact area would increase with the normal force. Therefore, in this study, we analyzed the trend of the friction coefficient of Si(100) and Mica according to the normal force and then. the contact area was calculated by JKR-theory. Results showed the friction coefficient was constant under 180 nm$^2$ contact area and over 180 nm$^2$ contact area, it was degraded. Moreover. the friction coefficient was constant according to the adhesion force.

  • PDF

Characteristics and Assessment of Printer Toner Adhesion (프린터 토너의 점착력 특성 및 평가 기법)

  • Lee, Jung-Eun;Kim, Kwang-Il;Kim, Hyun-Joon;Kim, Dae-Eun
    • Transactions of the Society of Information Storage Systems
    • /
    • v.5 no.2
    • /
    • pp.82-88
    • /
    • 2009
  • Understanding the adhesion behavior and characteristics of toner film is required to achieve image and text printing with high quality resolution. Toner can be considered as a thin film coating on a media such as paper or polymer film. Quantitative measurement of adhesion characteristics of the thin film is important to assess the reliability of the system. In this work the main objective was to investigate the adhesion characteristic between the toner and the media by ramp loading scratch test method. The scratch test may be used to obtain quantitative information about the adhesion of the film to the substrate. In the scratch test a diamond tip was used to scratch the surface of the toner film under an increasing normal load until the toner detached or fractured. The critical load (LC) was obtained from the experimental results. Also, the relationship between the critical load and the adhesive strength of the interface between the substrate and the toner was obtained by measuring the normal and tangential forces during the scratch test. Finally, theoretical analysis of the toner scratch characteristics was performed based on Benjamin and Weaver theory, Plowing model, and Laugier model.

  • PDF

P-Selectin-mediated Acute Inflammation Can Be Blocked by Chemically Modified Heparin, RO-Heparin

  • Gao, Yanguang;Li, Na;Fei, Rui;Chen, Zhihong;Zheng, Sheng;Zeng, Xianlu
    • Molecules and Cells
    • /
    • v.19 no.3
    • /
    • pp.350-355
    • /
    • 2005
  • Selectins are carbohydrate-binding cell adhesion molecules that play a major role in the initiation of inflammatory responses. Heparin can bind to P-selectin, and its anti-inflammatory property is mainly due to inhibition of P-selectin. However, the strong anticoagulant activity of heparin limits its clinical use. We prepared periodate-oxidized, borohydride-reduced heparin (RO-heparin) by chemical modification and tested its anticoagulant and anti-inflammatory activities. Activated partial thromboplastin time (aPTT) assays showed that, compared with heparin, RO-heparin had greatly reduced anticoagulant activity. Intravenous administration of this compound led to reduction in the peritoneal infiltration of neutrophils in a mouse acute inflammation model. In vitro cell adhesion experiments demonstrated that the effect of RO-heparin on inflammatory responses was mainly due to inhibiting the interaction of P-selectin with its ligands. These results indicate that RO-heparin may be a safer treatment for inflammation than heparin, especially when selectin is targeted.

Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System (방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능)

  • Oh, Chang-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • A currently used roof green system with multi layers has a low constructability. Therefore a new integrated waterproof & root barrier sheet and roof green box unit system was developed using steel plate fixture and cone type fixture by electromagnetic induction heating method. This study was proceeded to evaluate adhesion performance of two types of fixtures on Engineering PE, TPO, PVC sheet in a normal condition, repeated heating and cooling condition. As a result, adhesion load on Engineering PE sheet showed the highest value. The adhesion loads of steel plate fixture showed higher value as heating temperature was getting higher. However adhesion loads of cone type fixture showed opposite tendency. Regarding to the test conditions, test results of normal condition, repeated heating and cooling condition showed same value. The cone type fixture using butyl tape showed 7 times lower adhesion load than that of cone type fixture using electromagnetic heating and 28% lower adhesion load in a repeated heating and cooling condition than a usual condition.

Adhesion Prevention with Guardix® (Sodium Hyaluronate) After Flexor Tendon Repair in Rabbits (토끼 모델에서 굴근 인대 봉합 후 가딕스®의 유착 방지 효과)

  • Kim, Hark Young;Chang, Hak;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.543-547
    • /
    • 2009
  • Purpose: Adhesion is the most common and troublesome complication after repair of flexor tendon injury. Recently, use of sodium hyaluronate derivatives for adhesion prevention is increasing. A commercial product, Guardix$^{(R)}$, sodium hyaluronate(NaHe) combined with carboxymethylcellulose(CMC) has been newly developed as a preventive material for adhesion. We have investigated its effect in rabbits. Methods: Twenty seven male New Zealand white rabbits were operated under ketamine anesthesia. After tendon repair in zone II of the hind paw, Guardix$^{(R)}$(experimental group) or normal saline(control group) was administered. Biomechanical tests were performed to estimate adhesion formation at 2, 4, 8, and 12 weeks after the operation. Maximum tensile load to flex the distal interphalangeal joint 50 degree from its resting state(MTL50) was measured, depicting the amount of adhesion formed. Subsequently, breaking strength was assessed. Results: There were no postoperative complications such as infection, wound dehiscence, or hematoma. MTL50 was significantly lower in the experimental group than in the control group at 4, 8, 12 weeks (p<0.05). Mean value of MTL50 was 6.64N in the experimental group and 28.53N in the control group at 12 weeks after surgery. There were no significant differences in breaking strength. Conclusion: Our results indicate that Guardix$^{(R)}$ is helpful in reducing adhesion formation and does not interfere with normal healing processes of the tendon.