• Title/Summary/Keyword: nonpoint sources

Search Result 152, Processing Time 0.022 seconds

Optimum Capacity of Retention Basin for Treating Nonpoint Pollutants and Its Removal Efficiency in Industrial Complex Areas (산업단지내 비점오염물질 처리를 위한 적정 저류조 용량 산정 및 처리효율)

  • Kim, Lee-Hyung;Lee, Byung-sik;Kwon, Soo-Youl
    • Journal of Wetlands Research
    • /
    • v.7 no.3
    • /
    • pp.75-85
    • /
    • 2005
  • The Construction of industrial complex areas means the increase of imperviousness rate and the increase of nonpoint pollutant emissions during a rainfall. Generally the retention basin can become the alternative for removing and controling these nonpoint pollutants. Recently Ministry of Environment are trying to change the purpose of retention basins from flooding control to nonpoint pollutant control. In order to propel the stormwater management program, administration plan of stormwater management is enacted in Spring, 2005. Hereafter, in a newly developing area, the best management practices should be established to control the nonpoint pollutant. Landuses of the research area are classified to the categories of the 1st manufacturing industry, metal industry, fiber and chemical product manufacturing industry, etc. Therefore, this research was performed to understand washed-off characteristics of stormwater and to suggest the controling method of nonpoint pollutants. The optimum capacity of the retention basin can be determined by analyzing the relationships among data of rainfall, runoff, washed-off pollutants from the areas. The rainfall analysis using the data of normal year, recent 2, 5 and 10 years shows that the 80% rainfall frequency was occurred on 10mm accumulated rainfall, but which is not considered the first flush effect. However, by considering the first flush effect, the appropriate treatment capacity of rainfall can be decreased to 4-5mm accumulated rainfall. Using the criteria, the optimum capacity of retention basin is determined to $12,000m^3$ in the research area. The washed-off nonpoint pollutant loading from the areas have beeb calculated to 435ton/yr for TSS, 238ton/yr for COD, 8,518kg/yr for TKN and 1,816kg/yr for TP. The mass of 78.3ton/yr for TSS, 20.4ton/yr for BOD, 128.6ton/yr for COD, 4.6ton/yr for TKN and 980kg/yr for TP can be reduced by constructing the retention basin. The sediment accumulation rate is also calculated by $6.53kg/m^2-hr$.

  • PDF

Analysis of Stream Water Quality Improvement Using Surface-flow Wetland (자유수면형 인공습지에 의한 저농도 고유량의 하천수질개선 효과 분석)

  • Ham, Jong-Hwa;Yoon, Chun G.;Koo, Won-Seck;Kim, Hyung-Chul;Shin, Hyum-Bhum
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.1
    • /
    • pp.79-91
    • /
    • 2005
  • Wetland systems are widely accepted natural water purification systems around the world in nonpoint sources pollution control. Constructed wetlands have become a popular technology for treating contaminated surface and wastewater. In this study, the field experiment to reduce nonpoint source pollution loadings from polluted stream waters using wetland system was performed from June 2002 to March 2004, including winter performance using four newly constructed wetlands. The Dangjin stream water flowing into Seokmun estuarine lake was pumped into wetlands, and inflow and hydraulic residence time of the system was $500m^{3}{\~}1500m^{3}/day\;and\;2{\~}5$ days respectively. After 3 years operation plant-coverage was about $80~90\%$ from zero at initial stage even with no plantation. Average water quality of the influent in growing season was BOD_{5}\;3.96mg/L$, TSS 22.98 mg/L, T-N 3.29 mg/L, T-P 0.30 mg/L. The average removal rate of four wetlands for $BOD_{5},\;TSS,\;T-N\;and\;T-P$ in growing season was $24\%$, $62\%$, $54\%$, and $51\%$, respectively. And average water quality of the influent in winter season was $BOD_{5}$ 4.92 mg/L, TSS 12.47 mg/L, T-N 5.54 mg/L, and T-P 0.32 mg/L, respectively. The average removal rate of four wetlands for them was $-21\%$. $23\%$, $33\%$, and $53\%$, respectively. The reason of higher BOD_{5} effluent concentration in winter season might be that low temperature restrained microorganism activity and a organic body from the withered plant and algae was flown out. Except the result of $BOD_{5}$, the effectiveness of water quality improvement in winter season was satisfactory for treating polluted stream waters, and $BOD_{5}$ variation was within the range of background concentration. Performance of the experimental system was compared with existing data base (NADB), and it was within the range of general system performance. Overall, the wetland system was found to be satisfactory for NPS control such as improvement of polluted stream water.

Estimation of Pollutant EMCs and Loadings in Highway Runoff (국내 고속도로 강우 유출수의 EMCs 및 유출 부하량 산정)

  • Kim, Lee-Hyung;Ko, Seok-Oh;Lee, Byung-Sik;Kim, Sunggil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2B
    • /
    • pp.225-231
    • /
    • 2006
  • The nonpoint source control is based on TPLMS (Total Pollution Load Management System) program. Recently, the Ministry of Environment in Korea has programed TPLMS for 4 major large rivers to improve the water quality in rivers by controling the total pollutant loadings from the watershed area. Usually the urbanization is the main pollutant sources, particularly for nonpoint pollutants, because of high imperviousness and high pollutant mass emissions. The stormwater runoff from urban areas is containing various pollutants such as sediments, metals and toxic chemicals due to human and vehicle activities. Of the various landuses, the highways are highly polluted landuses because of high pollutant accumulation rate by vehicle activities during dry periods. Therefore, this research is achieved to provide pollutant EMCs (Event Mean Concentrations) and mass loadings washed-off from highways during rainfall periods. Five monitoring locations were equipped with an automatic rainfall gage and an flow meter. The results show that the EMC ranges for 95% confidence intervals in highway land use are 45.52-125.76 mg/L for TSS, 52.04-95.48 mg/L for COD, 1.77-4.48 mg/L for TN, 0.29-0.54 mg/L for TP. The ranges of washed- off mass loading are $712.7-2,418.4mg/m^2$ for TSS and $684.1-1,779.6mg/m^2$ for COD.

Characteristics of Non-Point Sources Pollutant Loads at Paddy Plot Located at the Valley Watershed during Irrigation Periods (관개기 곡간지 유역 필지논에서의 비점원오염물질 유출특성)

  • Han, Kuk-Heon
    • KCID journal
    • /
    • v.18 no.1
    • /
    • pp.94-102
    • /
    • 2011
  • The aim of this study was to evaluate the load of non-point sources pollutant at a paddy plot located at the valley watershed during irrigation period. Irrigation, runoff and water quality data in the paddy plot were analyzed periodically from June 1 to October 31 in 2005. The observed amount of precipitation, irrigation, runoff for the experimental paddy plot during the irrigation period was 1,297.8, 223.2, and 825.4mm, respectively. Total-N concentrations ranged from 3.73 to 18.10mg/L, which was generally higher than the quality standard of agricultural water (1.0mg/L). Total-P concentrations ranged from 0.111 to 0.243mg/L and the average was 0.139mg/L. The observed runoff pollutants loadings from the paddy plot were measured as 34.4 kg/ha for T-N, 1.0 kg/ha for T-P and 213.8 kg/ha for SS. The non-point sources pollutant load in drainage water depends on rainfall and surface drainage water amount from the paddy plot. We are considering that these results were affected by rainfall as well as hydrological condition, soil management, whether or not fertilizer application, cropping, rice straw and plowing.

  • PDF

The effect of phosphorus removal from sewage on the plankton community in a hypertrophic reservoir

  • Jung, Sungmin;Kim, Kiyong;Lee, Yunkyoung;Lee, Jaeyong;Cheong, Yukyong;Reza, Arif;Kim, Jaiku;Owen, Jeffrey S.;Kim, Bomchul
    • Journal of Ecology and Environment
    • /
    • v.40 no.1
    • /
    • pp.66-74
    • /
    • 2016
  • Background: When developing water quality improvement strategies for eutrophic lakes, questions may arise about the relative importance of point sources and nonpoint sources of phosphorus. For example, there is some skepticism regarding the effectiveness of partial reductions in phosphorus loading; because phosphorus concentrations are too high in hypertrophic lakes, in-lake phosphorus concentrations might still remain within typical range for eutrophic lakes even after the reduction of phosphorus loading. For this study, water quality and the phytoplankton and zooplankton communities were monitored in a hypertrophic reservoir (Lake Wangsong) before and after the reduction of phosphorus loading from a point source (a sewage treatment plant) by the installation of a chemical phosphorus-removal process. Results: Before phosphorus removal, Lake Wangsong was classified as hypertrophic with a median phosphorus concentration of $0.232mg\;L^{-1}$ and a median chlorophyll-a concentration of $112mg\;L^{-1}$. The dominant phytoplankton were filamentous cyanobacteria for the most of the ice-free season. Following the installation of the advanced treatment process, phosphorus concentrations were reduced to $81mg\;L^{-1}$, and the N/P atomic ratio increased from 42 to 102. Chlorophyll-a concentrations decreased to $42{\mu}g\;L^{-1}$, and the duration of cyanobacterial dominance was confined to the summer season. Cyanobacteria in spring and autumn were replaced by diatoms and cryptomonads. Filamentous cyanobacteria in summer were replaced by colony-forming unicellular Microcystis spp. It was remarkable that zooplankton biomass increased despite the decrease in phytoplankton biomass, and especially cladoceran zooplankton which increased drastically. These responses to the reduction of point source P loading to Lake Wangsong imply that reducing the point source P loading can have a big impact even when nonpoint sources account for a large fraction of the total annual phosphorus loading. Conclusions: Our results also show that the phytoplankton community can shift to decreased cyanobacterial dominance and the zooplankton community can shift to higher cladoceran dominance, even when phosphorus concentrations remain within the typical range for eutrophic lakes following the reduction of phosphorus loading.

Selection of Best Management Practices for Urban Watershed Corresponding to the Runoff Characteristics from Non-point Pollution Sources (도시지역의 비점오염유출특성을 고려한 도시하천 적정관리방안)

  • Chi, Hong-Jin;Shin, Gwy-Am
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.31-40
    • /
    • 2016
  • The purpose of this study was to analyse the runoff characteristics of non-point pollution sources in an urban watershed and determine the effectiveness of newly installed riverwater treatment system to reduce water pollution caused by storm runoff in the urban watershed. The results of this study showed that the levels of BOD5 and suspended solid were highly influenced by first-flush effect and the pollutant load of those two parameters were also very high in the urban watershed. Meanwhile, the effectiveness of riverwater treatment system to reduce the levels of BOD5 and suspended solid was relatively high, but those to reduce the levels of T-N and T-P was low, which needs some additional unit treatment process such as filtration and coagulation. Nonetheless, the riverwater treatment system tested was relatively simple in installation and operation, effective in removing many water pollutants and, most importantly, does not require much space as other treatment systems, so it could be an attractive alternative option to reduce riverwater pollution caused by storm runoff in urban watersheds.

Calibration of HSPF Model from Mangyeong River Watershed (만경강유역에서의 HSPF 모형의 보정)

  • Jung, Jae-Woon;Jang, Jeong-Ryeol;Jung, Ji-Yeon;Choi, Kang-Won;Lim, Byung-Jin;Kim, Sang-Don;Kim, Kap-Soon;Yoon, Kwang-Sik
    • KCID journal
    • /
    • v.18 no.1
    • /
    • pp.58-67
    • /
    • 2011
  • The HSPF (Hydrological Simulation Program-Fortran) model was applied to Mangyeong river watershed to examine its applicability through calibration using monitoring data. For the model application, digital maps were constructed for watershed boundary, land-use, Digital Elevation Model of Mangyeong river watershed using BASINS (Better Assessment Science for Intergrating point and Nonpoint Sources) program. The observed runoff was 1976.4mm while the simulated runoff was 1913.4mm from 2007 to 2008. The model results showed that the simulated runoff was in a good agreement with the observed data and indicated reasonable applicability of the model. In terms of water quality, trends of the observed value were in a good agreement with simulated value despite its model performance lower than expected. However, its reliability and performance were with the expectation considering complexity of the watershed, pollutant sources and land use intermixed in the watershed. Overall, we identified application of HSPF model as reliable evidence by model performance.

  • PDF

Determination of Nonpoint pollutant Unit Loads in Toll-gate of Highway (고속도로 영업소 토지이용에서의 비점오염원 원단위 산정)

  • Son, Hyun-Geun;Lee, Eun-Ju;Lee, So-Young;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.10 no.1
    • /
    • pp.69-75
    • /
    • 2008
  • Toll-gate in highways often received the pollution impact from transportation/vehicular activities. Thus, concentrated pollutants carried by stormwater runoff are directed to nearby streams affecting the water quality and ecosystem. In order to determine the environmental impact on nearby waterbodies and predict the future impact by stormwater runoff, the unit pollutant loads from various landuses are really important. This research was performed to characterize the stormwater runoff and to provide the unit loads from Toll-gate landuses in Korea. The monitoring was conducted at toll gate locating in Gaeryoung City during 2006-2007. The water quality parameters including TSS, COD, DOC, TN, and TP were analyzed and also the flow rates were measured during the monitoring. In this paper, EMCs will be calculated by using the monitored water quality concetraions and flow rates, which will be used to determine the unit pollutant loads from the toll-gate of highway.

  • PDF

Water Pollution in Some Agricultural Areas along Nakdong River (낙동강 수계 주요 농업지대 소유역의 수질 오염)

  • Chung, Jong-Bae;Kim, Bok-Jin;Kim, Jeong-Kook
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.2
    • /
    • pp.187-192
    • /
    • 1997
  • We carried out a survey on tributary streams in some agricultural areas along Nakdong River to evaluate the effects of agricultural practices on pollution of stream water and groundwater. General properties, nutrient materials and heavy metals in water samples were measured. General physicochemical properties of tributary stream waters were at levels favorable for agricultural water. Heavy metals, except Zn, were mostly not detected. Total-N contents were much higher than the criteria of agricultural water, and nitrate-N accounts for more than a half of total-N. Phosphorus contents were higher than the lower level of P for algae growth and the contents were high especially in summer. In ground waters which are used for irrigation, P were mostly at same levels as those in streams, and nitrate contents were higher than 10mg/L in some samples. In these results only those N and P contents in stream and ground waters higher than pollution criteria are problematic and they are traceable to agricultural nonpoint sources-fertilizers, livestock farms and sewage. Further researches are needed to evaluate contributions of each nonpoint source on stream water pollutions.

  • PDF

Status of Water Quality and Future Plans in the Philippines (필리핀의 수질현황 및 미래 관리계획)

  • Gorme, Joan B.;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.11 no.3
    • /
    • pp.89-103
    • /
    • 2009
  • The Philippines is abundant with rich natural resources such as water. Because of rapid urbanization in the country, most of the water bodies are polluted as a result of domestic, agricultural and industrial activities. The Environmental Management Bureau (EMB) is the main government arm responsible for monitoring and inspection of affected water bodies. Only water bodies with at least four sampling events during dry and wet seasons were included in the assessment of water bodies that passed the DAO 90-34 water quality criteria. Water bodies were monitored for dissolved oxygen (DO), biochemical oxygen demand (BOD), total suspended solids (TSS), and total dissolved solids (TDS), heavy metals, fecal coliform contamination and nitrates. High pollutant concentrations from domestic, agricultural, industrial and nonpoint sources were observed from monitoring events due to inadequate sewage services and treatment facilities in the country. The objective of this paper was to present and evaluate the quality of the water bodies in the Philippines.

  • PDF