• Title/Summary/Keyword: non-woven fabric

Search Result 149, Processing Time 0.032 seconds

Development of nonwoven fabric and new adhesive system to manufacture hybrid corrugated board (농산물용 복합 골판지 제조를 위한 부직포 및 신규 접착시스템에 대한 연구)

  • Lee, Ji-Young;Yoon, Hee-Youl;Oh, Seok-Ju;Sung, Yong-Joo;Kim, Byeong-Ho;Lim, Gi-Baek;Choi, Jae-Sung;Kim, Sun-Young
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.3
    • /
    • pp.49-55
    • /
    • 2012
  • Even though corrugated boards are the most common packaging materials for agricultural products, conventional corrugated boards are not able to maintain the freshness of agricultural products. In order to overcome the limitations of conventional corrugated boards, a new hybrid corrugated board-composed of linerboard, a corrugating medium, and non-woven fabric-was designed to possess antibacterial, high porous and shock-absorbing properties. In this study, we compared the physical properties of non-woven fabric to those of the base papers of conventional corrugated boards and developed a new adhesive system as a first step toward manufacturing the hybrid corrugated board. We found that the non-woven fabric, which had relatively high elongation, was applicable in the corrugated board process, and that the manufacturing conditions must be controlled in order to prevent the break of the non-woven fabric. The mixture of starch and styrene-butadiene (SB) latex showed high adhesive strength, but the addition level of SB latex should not exceed 30% in starch solution.

WASTEWATER TREATMENT USING COMBINATION OF MBR EQUIPPED WITH NON-WOVEN FABRIC FILTER AND OYSTER-ZEOLITE COLUMN

  • Jung, Yoo-Jin;Koh, Hyun-Woong;Shin, Won-Tae;Sung, Nak-Chang
    • Environmental Engineering Research
    • /
    • v.10 no.5
    • /
    • pp.247-256
    • /
    • 2005
  • A combination of the submerged membrane activated-sludge bioreactor(SMABR) equipped with non-woven fabric filter and oyster-zeolite (OZ) packed-bed adsorption column was studied to evaluate the advanced tertiary treatment of nitrogen and phosphorous. The non-woven filter module was submerged in the MBR and aeration was operated intermittently for an optimal wastewater treatment performance. Artificial wastewater with $COD_{Cr}$ of 220 mg/L, total nitrogen (T-N) of 45 mg/L, and total phosphorous (T-P) of 6 mg/L was used in this study. MLSS was maintained about $4,000\;{\sim}\;5,000\;mg/L$ throughout the experiments. The experiments were performed for 100-day with periodic non-woven filter washing. The results showed that $COD_{Cr}$ could be effectively removed in SMABR alone with over 94% removal efficiency. However, T-N and T-P removal efficiency was slightly lower than expected with SMABR alone. The permeate from SMABR was then passed through the OZ column for tertiary nutrients removal. The final effluent analysis confirmed that nutrients could be additionally removed resulting in over 87% and 46% removal efficiencies for T-N and T-P, respectively. The results of this study suggest that the waste oyster-shell can be effectively reclaimed as an adsorbent in advanced tertiary wastewater treatment processes in combination with SMABR equipped with non-woven fabric filter.

Temperature History of Slab Concrete Depending on Insulation Curing Method in Cold Weather Concreting (한중시공시 단열양생방법 변화에 따른 슬래브 콘크리트의 온도이력 특성)

  • Kim Jong-Back;Lim Choon-Goun;Park Koo-Byoung;Kim Seoung-Soo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.17-20
    • /
    • 2005
  • This paper reported the temperature history of concrete placed at deck plate slab under cold climate condition by varying with surface insulating type. No curing sheet and simple insulation curing including non-woven fabric, double layer bubble sheet, the combination of double layer bubble sheet and non-woven fabric dropped temperature below zero within 24 hours, which caused frost damage at early age. On the other hand, the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam maintained minimum temperature above $4^{\circ}C\;and\;8^{\circ}C$, respectively. Based on core test results compressive strength of concrete with the combination of double layer bubble sheet and non-woven fabric and double layer bubble sheet and styrofoam was higher than those with other curing method due to good insulation effect.

  • PDF

Removal Characteristics of Rainwater Including Non-point Pollutants Using Pre-filter of Wasted-tire and Non-woven Fabric (폐타이어와 부직포를 이용한 프리필터에 의한 비점오염원 포함 우수 처리 특성)

  • Yoo, Kyuseon;Han, Hakyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.655-659
    • /
    • 2005
  • Pre-filter system that was consisted of wasted-tire, non-woven fabrics, and sponge was developed as a primary treatment process prior to rainwater reservation or a pre-treatment process of rainwater reuse system for reclamation. By using this system, SS concentration, TOC, COD, and turbidity could decreased by 86.7%, 62.6%, 69.1% and 66.5%, respectively. From the results of particle size distribution of treated water, the particles over than $30{\mu}m$ of diameter were completely removed by pre-filter system. But 90% of particles less than $20{\mu}m$ of diameter were passed through pre-filter. Optimal depth of wasted-tire and non-woven fabrics were 15cm and 2.4cm, respectively. Pre-filter system was considered as an effective alternative for pre-treatment of rainwater including non-point pollutants and it could be also applied for the treatment of combined sewer overflow (CSO).

Fiber network with superhydrophilic Si-DLC coating

  • Kim, Seong-Jin;Mun, Myeong-Un;Lee, Gwang-Ryeol;Kim, Ho-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.363-363
    • /
    • 2010
  • The high capillarity of a plastic fiber network having superhydrophilic Si-DLC coating is studied. Although the superhydrophilic surface maximize wetting ability on the flat surface, there remains a requirement for the more wettable surface for various applications such as air-filters or liquid-filters. In this research, the PET non-woven fabric surface was realized by superhydrophilic coating. PTE non-woven fabric network was chosen due to its micro-pore structure, cheap price, and productivity. Superhydrophobic fiber network was prepared with a coating of oxgyen plasma treated Si-DLC films using plasma-enhanced chemical vapor deposition (PECVD). We first fabricated superhydrophilic fabric structure by using a polyethylene terephthalate (PET) non-woven fabric (NWF) coated with a nanostructured films of the Si-incorporated diamond-like carbon (Si-DLC) followed by the plasma dry etching with oxygen. The Si-DLC with oxygen plasma etching becomes a superhydrophilic and the Si-DLC coating have several advantages of easy coating procedure at room temperature, strong mechanical performance, and long-lasting property in superhydrophilicity. It was found that the superhydrophobic fiber network shows better wicking ability through micro-pores and enables water to have much faster spreading speed than merely superhydrophilic surface. Here, capillarity on superhydrophilic fabric structure is investigated from the spreading pattern of water flowing on the vertical surface in a gravitational field. As water flows on vertical flat solid surface always fall down in gravitational direction (i.e. gravity dominant flow), while water flows on vertical superhydrophilic fabric surface showed the capillary dominant spreading.

  • PDF

A study on the Internal machining of a large-diameter Stainless pipe for Semiconductor Using Experimental Design Method (실험계획법을 이용한 반도체용 대구경 스테인레스관의 내경 가공에 관한 연구)

  • 김창근;이은상
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.71-76
    • /
    • 2003
  • This paper describes the characteristic of a large-diameter pipe to obtain smooth surface using Electropolishing after grinding using a non-woven fabric. Grinding using a non-woven fabric is possible under lower load and fine effect comparing with Wheel grinding. Also, the ion from the surface of the metal is eliminated by means of an electrical potential and current in Electropolishing. Electropolishing is used for leveling the surface, improving the physical appearance of the part, promoting corrosion properties and reducing contamination and adhesion of the surface. Therefore, the aim of the present study is to investigate the internal machining of a large-diameter pipe for semiconductor using experimental design method.

  • PDF

Effects of Layers of Non-woven Fabric on the Growth and Flowering of Edile Flower Tropaeolum majus L. in the Vertical Greening System for Lower Maintenance Urban Agriculture (저관리 도시농업을 위한 벽면녹화 부직포 처리가 식용꽃인 한련화(Tropaeolum majus L.)의 생육과 개화에 미치는 영향)

  • Park, Jae-Hyeon;Yoon, Young-Han;Lee, Jae-Man;Song, Hee-Yeon;Ju, Jin-Hee
    • Journal of Environmental Science International
    • /
    • v.28 no.6
    • /
    • pp.545-552
    • /
    • 2019
  • Tropaeolum majus, with a high decorative and food demand for vertical greening systems, has been utilized to revitalize urban agriculture. The effects of number of non-woven fabrics in a non-water environment and the adaptability of T. majus to this system were investigated. Planting ground composition of the container-type wall vertical greening system was made using non-woven fabric in one, two, three, or four layers. The results showed that the soil water content remained the highest when the non-woven fabric comprised 4 sheets. The morphological properties showed more growth with the 4 sheets than with 1, 2, and 3 sheets. In terms of physiological characteristics, chlorophyll content was mostly high in the 4 sheets, while shoot fresh weight value was in the order of 3 > 4 > 2 > 1 sheet, and root fresh weight value was in the order of 4 > 2 > 1 > 3 sheets. The dry weight of the measured values in the shoot was in the order of 4 > 3 > 2 > 1 sheet while no clear difference was found in the root of each treatment. The difference in the flowring characteristics was not different, but in evaluating the characteristics as a whole, the growth in the three layers of non-waven fabric was the best. In addition, the soil moisture contents and the growth characteristics were statistically significant as a positive correlation between the groups. Thus, greater the non-woven fabric, the higher is the adaptability of T. majus to dry stress under soil water-free conditions by maintaining soil moisture content. This showed that it represented an effective alternative as a method of vertical greening system for lower maintenance urban agriculture.

Studies on the Optimum Pulping Condition of Ramie and the Mechanical Properties of Ramie/Cotton Non-woven Fabric as Hygienic Uses (Ramie의 최적 펄핑 조건 및 위생용 ramie/면 부직포의 물리적 특성 연구)

  • Choi, Si-Hyuk;Kim, Hyun-Chel
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.6
    • /
    • pp.16-25
    • /
    • 2014
  • This study was investigated in optimum condition of pulping of ramie and the mechanical properties of non-woven fabric for the performance of ramie/cotton panty liner. The result of pulping condition on ramie was most suitable for type I (mixed NaOH with $Na_2CO_3$ in 30%:70%). The sample (I) was showed yield value of 68.2% and the best fibrillation and lignin removal rate. The non-woven fabrics of ramie/cotton were made in range of ramie content of 0, 15 and 30%. As ramie content increased, so were increased in air permeability, compressive strength and compression recovery rate. But surface roughness and compressional energy were decreased. Therefore, the non-woven fabrics of ramie/cotton are very suitable in hygienic goods for female panty liner. The ramie panty liner showed a little decrease in absorption and strength, as increasing the amount of ramie. But the performance of ramie panty liner was appeared beyond standard values used by usual panty liner.

Effect of Storage Conditions on Graft of Polypropylene Non-woven Fabric Induced by Electron Beam (전자선 조사된 폴리프로필렌 부직포의 그라프트에 있어 보관조건이 미치는 영향)

  • Lee, Jin Young;Jeun, Joon-Pyo;Kang, Phil-Hyun
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.57-62
    • /
    • 2015
  • In this study, we fabricated effect of storage conditions on graft of polypropylene (PP) non-woven fabric induced by electron beam. The electron beam irradiations on PP non-woven fabric were carried out over a range of irradiation doses from 25 to 100 kGy to make free radicals on fabric surface. The radical measurement was established by electron spin resonance (ESR) for confirming the changes of the alkyl radical and peroxy radical according to effect of storage time, storage temperature and atmosphere. It was observed that the free radicals were increased with irradiation dose and decreased with storage time due to the continuous oxidation. However, the radical extinction was significantly delayed due to reduced mobility of radicals at extremely low temperature. The degree of graft based on the analysis of ESR was investigated. The conditions of graft reaction were set at a temperature: $60^{\circ}C$, reaction time: 6 hours and styrene monomer concentration: 20 wt%.

Plasma Treatment Effect of Organic/Organic Core-Shell Acrylic Adhesive Binder (II) (Organic/Organic Core-Shell 아크릴 접착바인더의 플라즈마 처리영향 (II))

  • Seul, Soo-Duk
    • Polymer(Korea)
    • /
    • v.34 no.2
    • /
    • pp.89-96
    • /
    • 2010
  • Adhesive binders with core-shell structure of organic/organic pair were prepared by emulsion polymerization of acrylic monomers, such as methyl methacrylate(MMA), ethyl acrylate(EA), n-butyl acrylate(BA), and styrene(St). Ammonium persulfate (APS) was used as an water soluble initiator in the presence of an anionic surfactant, sodium dodecyl benzene sulfonate (SDBS). Non-woven fabric and leather were impregnated with the adhesive binder. The surface of the impregnated fabric and leather were treated with plasma technique and then kinetics analysis and mechanical properties were measured. The conversions of the polymerization of core-shell binder (MMA/EA, MMA/BA) were greater than 90%. When the core-shell binder was prepared at equimolar conditions, the increasing effect of the core-shell binder on the state peel strength of the impregnated and plasma-treated non-woven/non-woven fabric has the order of MMA/St, EA/BA, BA/MMA, EA/St, and EA/MMA. When the core-shell binder was prepared at non-equimolar conditions, the increasing effect of the core-shell binder on the state peel strength of the non-woven fabric/leather has the order of MMA/BA, BA/EA, MMA/EA, St/MMA, and EA/St.