• 제목/요약/키워드: non-linear connection

검색결과 127건 처리시간 0.027초

계층 구조의 비선형 피드포워드 수열 발생기 (Layered Nonlinear feed-forward Sequence Generator)

  • 은유창;홍윤표;진석용;송홍엽
    • 한국통신학회논문지
    • /
    • 제29권5C호
    • /
    • pp.595-600
    • /
    • 2004
  • 선형복잡도(linear complexity)가 크고 균형(balance) 특성이 좋은 수열은 스트림 암호(stream cipher) 또는 보안성이 요구되는 대역 확산 통신(spread spectrum communication) 등에 이용될 수 있다. 이러한 수열을 발생하기 위하여, 최대길이 수열(m-sequence)을 계층 구조의 비선형 피드포워드 로직(NLFFL; Non-Linear Feed-Forward Logic) 필터 함수에 통과 시켜 랜덤 수열을 얻는 방법이 Groth에 의해 제안되었다. 본 논문에서는 Groth의 계층 구조를 변형하여 Langford 연결법과 같은 특별한 비선형 연결 방법 없이도 잡음 특성이 좋은 수열을 발생시킬 수 있는 방법을 제시한다.

Behavior and modeling of single bolt lap-plate connections

  • Rex, Clinton O.;Easterling, W. Samuel
    • Steel and Composite Structures
    • /
    • 제2권4호
    • /
    • pp.277-296
    • /
    • 2002
  • A research investigation of single bolt lap-plate connection load-deformation behavior is presented. Each important characteristic of this behavior is evaluated and two methods for analytically approximating the behavior are developed and presented. The first of these methods is a component method in which the behavior of the connection is modeled as a combination of the behavior of the parts. The second method utilizes a number of parametric relationships that relate the connection parameters to coefficients of two non-linear continuous analytical curves. The test results from four independent experimental programs that investigated the behavior of single bolt lap-plate connections are used in the development and verification of these methods.

A Modified Shooting Method Technique for the Analysis of the Limited Slip Capacity of UHPFRC-NC Composite Structure

  • Han, Sang-Mook;Wu, Xiangguo;Kim, Sung-Wook;Kang, Su-Tae
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1061-1064
    • /
    • 2008
  • Shear connectors have a finite slip capacity because of the mechanism by which they transfer the shear between UHPFRC and NC elements. At high degree of shear connection, non-linear analysis techniques are required to allow for compressive plasticity and tensile cracking behaviour of the elements. As with all non-linear problems, a closed form solution is difficult to find. A Modified Shooting Method Technique is developed here for non-linear analysis of UHPFRC/concrete composite. The initial effective moment is derived according to the prestressing force. The composite structure is divided into small segments which length is much less than the length of the structure and it can be assumed that the forces and displacements within each segment are constant. An equivalent analysis in composite girders would be to fix the slip strain in each segment and develop a moment curvature relationship for this slip strain in each segment. Additive forces and moment analysis on each section of the segments are analyzed by MSMT. Finally the ultimate slippage of the interface can be evaluated by the MSMT model. This paper presents a nonlinear analysis method for limited slip capacity of UHPFRC-NC interface.

  • PDF

Experimental and numerical analysis of the global behaviour of the 1:9 scale model of the Old Bridge in Mostar

  • Kustura, Mladen;Smoljanovic, Hrvoje;Nikolic, Zeljana;Krstevska, Lidija
    • Coupled systems mechanics
    • /
    • 제10권1호
    • /
    • pp.1-19
    • /
    • 2021
  • Composite nature of the masonry structures in general causes complex and non-linear behaviour, especially in intense vibration conditions. The presence of different types and forms of structural elements and different materials is a major problem for the analysis of these type of structures. For this reason, the analysis of the behaviour of masonry structures requires a combination of experimental tests and non-linear mathematical modelling. The famous UNESCO Heritage Old Bridge in Mostar was selected as an example for the analysis of the global behaviour of reinforced stone arch masonry bridges. As part of the experimental research, a model of the Old Bridge was constructed in a scale of 1:9 and tested on a shaking table platform for different levels of seismic excitation. Non-linear mathematical modelling was performed using a combined finite-discrete element method (FDEM), including the effect of connection elements. The paper presents the horizontal displacement of the top of the arch and the failure mechanism of the Old Bridge model for the experimental and the numerical phase, as well as the comparison of the results. This research provided a clearer insight into the global behaviour of stone arch masonry structures reinforced with steel clamps and steel dowels, which is significant for the structures classified as world cultural heritage.

Coupling of nonlinear models for steel-concrete interaction in structural RC joints

  • Dominguez, Norberto;Perez-Mota, Jesus
    • Coupled systems mechanics
    • /
    • 제3권2호
    • /
    • pp.195-211
    • /
    • 2014
  • When strong seismic forces act on reinforced concrete structures, their beam-column connections are very susceptible to damage during the earthquake event. The aim of this numerical work is to evaluate the influence of the internal steel reinforcement array on the nonlinear response of a RC beam-column connection when it is subjected to strong cyclic loading -as a seismic load. For this, two specimens (extracted from an experimental test of 12 RC beam-column connections reported in literature) were modeled in the Finite Element code FEAP considering different stirrup's arrays. In order to evaluate the nonlinear response of the RC beam-column connection, the 2D model takes into account the nonlinear thermodynamic behavior of each component: for concrete, a damage model is used; for steel reinforcement, it is adopted a classical plasticity model; in the case of the steel-concrete bonding, this one is considered perfect without degradation. At the end, we show a comparison between the experimental test's responses and the numerical results, which includes the distribution of shear stresses and damage inside the concrete core of the beam-column connection; in the other hand, the effects on the connection of a low and high state of confinement are analyzed for all cases.

하이브리드 프리캐스트 보-기둥 접합부의 해석적 연구 (Analytical Study on Hybrid Precast Concrete Beam-Column Connections)

  • 최창식;김승현;최윤철;최현기
    • 콘크리트학회논문집
    • /
    • 제25권6호
    • /
    • pp.631-639
    • /
    • 2013
  • 이 연구에서는 기존에 수행된 시공성과 경제성이 향상되고 중진 지역에서 사용 가능한 새로운 프리캐스트 콘크리트 보-기둥 접합상세의 비선형 유한요소해석이 수행되었다. 해당 상세는 복합구조를 기반으로 함으로써 기둥 내에는 각관을 보유하고 있으며 보에는 강판이 매입되어 있는 복잡한 단면을 보유하고 있다. 또한 콘크리트와 강재뿐만 아니라 ECC라는 새로운 재료를 사용함에 따라 요소의 선택 및 재료모델의 결정에 대한 방법론을 제시하였다. 비선형 유한요소해석은 상용 유한요소해석 프로그램인 ABAQUS를 통해 수행되었으며 요소 및 재료 모델은 ABAQUS에서 제공하는 모델들을 사용하였다. 비선형 유한요소해석 결과 기 수행되었던 실험 결과에 유사하거나 보수적으로 평가함으로써 변수분석에 사용할 수 있을 것으로 판단하였다. 구축된 유한요소해석 모델을 통해 해당 상세의 성능에 대한 압축력의 영향, 휨강도비의 영향에 대해 분석하였다. 압축력의 경우 기둥 압축강도의 10~20%에서 가장 좋은 성능을 발휘할 수 있었으며, 휨강도비 1.2 이상에서 기둥의 항복 없이 보의 소성힌지를 유도할 수 있음을 확인하였다.

T 스티프너를 이용한 CFT기둥-H 형강보 실대형 접합부의 비선형 해석 (Non-linear Analysis of Full Scaled CFT Column to H-Beam Connections with T-Stiffeners)

  • 이승우;김영주;신경재;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제14권6호
    • /
    • pp.835-843
    • /
    • 2002
  • 본 논문은 외부 T스티프너로 보강한 콘크리트 충전각형강관-H형강보 접합부의 응력전달 메카니즘을 유한요소해석을 통해 정확히 이해하고, T스티프너에 관한 설계기본자료를 제공하는데 그 목적이 있다. 따라서 선행된 실대형 접합부의 실험결과와 비선형 유한요소해석의 결과를 비교함으로써 유한요소해석의 신뢰도를 높였다. 유한요소해석에서 접합부의 응력전달 메카니즘을 이해하기 위해 여러 가지의 응력 및 변형도 지수를 사용하였고, 유한요소해석을 통하여 실험에서 발견된 보플랜지와 수평스티프너 접합부의 응력집중을 감소시킬수 있는 방안을 모색하였다.

고장력 볼트 이음부의 3차원 유한요소 해석 (3D Finite Element Analysis of High Tension Bolted Joints)

  • 심재수;김춘호;김동조
    • 한국강구조학회 논문집
    • /
    • 제16권4호통권71호
    • /
    • pp.407-414
    • /
    • 2004
  • 공용중인 교량은 시공시에 비해 이음부재 및 볼트에 각종 하중이 작용하는 상태이고, 시공중에 결함이 발생하였거나 시간이 지남에 따른 각종 결함이 발생되고 있다. 실험적인 연구에 의해 이러한 결함들이 있는 고장력볼트 이음부의 역학적 성질을 규명하기 위해서는 많은 재비용이 필요한 실정이므로 실험적으로 밝혀내기 어려운 결함이 있는 고장력볼트 이음부의 거동과 구조적 특성을 유한요소 해석을 통하여 규명하고 차후 실험에 의한 연구시 충분한 실험결과의 예측, 시험체의 설계 및 경제적인 실험적 연구의 수행을 위한 자료를 제공하는데 본 연구의 목적이 있다. 각종 결함이 발생하고 있는 교량을 대상으로 현장조사를 하여 결함의 발생위치 및 유형을 분석하고 가장 많이 발생하는 결함을 중심으로 표준모델에 결함을 주어 내부응력 분포 및 미끄러짐 거동에 대한 해석을 수행하였다. 정상체결된 고장력 볼트 이음부 및 볼트간격, 모재두께, 연단거리, 볼트 구멍 크기, 확공에 따른 결함을 가정하여 내부응력분포에 대한 구조해석을 수행하였다. 또한 고장력볼트 이음부의 미끄러짐 거동에 대해 해석하였는데 이 해석은 대변형을 고려한 기하학적 비선형, 접촉면의 비선형을 고려한 경계 비선형, 미끄러짐에 의해 항복강도를 초과하는 부분이 생길 수 있으므로 재료적 비선형 문제를 고려하여 해석하였다. 정상적으로 체결된 고장력볼트 이음부 및 볼트 축력의 감소에 따른 미끄러짐 해석을 수행하였다.

PHC파일간 연결 시공성 개선 이음판형 기계적 연결부의 연결저항 (Connection Resistance of Mechanical Joint using Connection plate for Improvement of Connectivity between PHC piles)

  • 안진희;문홍득;하민균;조광일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.25-32
    • /
    • 2019
  • PHC 파일의 파일간 연결공법으로 용접이음과 볼트이음을 이용한 기계적 이음들이 적용되고 있으나 시공과정 등에서 품질 및 성능 확보에 어려움이 발생할 수 있다. 본 연구는 기존 PHC파일 연결부가 가지는 단점을 개선하고 PHC 파일 연결부 성능을 확보할 수 있는 무용접 이음판형 기계적 PHC파일 연결부를 제안하고 비선형 구조해석과 실제 PHC파일 연결부 실험을 통하여 제안된 PHC 파일 연결부의 연결성능을 평가하였다. 제안된 PHC파일 연결부의 비선형 구조해석 결과 연결부는 휨, 압축, 인장, 전단, 편심압축 하중 상태에서 충분한 연결성능을 확보하는 것으로 평가되었으며, 실제 휨하중 재하실험에서 PHC파일의 균열 및 휨 모멘트 수준 이상에서도 안정적인 선형거동을 가지고 있는 것으로 나타났다. 따라서 제안한 무용접 이음판형 기계적 PHC파일 연결부는 충분한 연결성능을 확보할 수 있는 것으로 판단된다.

Steady-State Harmonic Domain Matrix-Based Modeling of Four-Quadrant EMU Line Converter

  • Wang, Hui;Wu, Mingli;Agelidis, Vassilios G.;Song, Kejian
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.572-579
    • /
    • 2014
  • As a non-linear time variant system, the four-quadrant line converter of an electric multiple unit (EMU) was expressed by linear time periodic functions near an operating point and modeled by a steady-state harmonic domain matrix. The components were then combined according to the circuit connection and relations of the feedback control loops to form a complete converter model. The proposed modeling method allows the study of the amplitude of harmonic impedances to explore harmonic coupling. Moreover, the proposed method helps provide a better design for the converter controllers, as well as solves the problem in coordination operation between the EMUs and the AC supply. On-site data from an actual $CRH_2$ high-speed train were used to validate the modeling principles presented in the paper.