• Title/Summary/Keyword: non-linear characteristics

Search Result 1,045, Processing Time 0.03 seconds

Characteristics Analysis for Voltage, Current & Capacity of Condenser at Voltage Unbalance (전압 불평형시 콘덴서 전압, 전류, 용량 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.145-151
    • /
    • 2010
  • Voltage unbalance is regarded as a power quality problem of significant at the user application. Although the voltages are quite well balanced at the transmission system, the voltage level of utilization can be unbalanced due to the unequal system impedances and the unequal distribution of single phase loads. Capacitor is generally used for power-factor compensation and reducing harmonics of non linear load with reactor. If voltage unbalance exists, current unbalance is generated and it will be reflected in the capacity variance. When the reactor and condenser are used at the same location, generally its trouble rate is high. And it is very important checking out that how the variance of voltage, current and capacity of condenser is proceeded by the voltage unbalance. In this paper, we calculated that voltage, current and capacity of condenser are within the tolerance limit of official regulations in the event of voltage unbalance with/without reactor.

Quantitative Assay of Recombinant Hepatitis B Surface Antigen by Using Surface Plasmon Resonance Biosensor (Surface plasmon resonance 바이오센서를 이용한 재조합 B형 간염 표면항원의 정량분석)

  • Lee, E. K.;Ahn, S. J.;Yoo, C. H.;Ryu, K.;Jeon, J. Y.;Lee, H. I.;Choi, S. C.;Lee, Y. S.
    • KSBB Journal
    • /
    • v.17 no.1
    • /
    • pp.20-25
    • /
    • 2002
  • We performed a basic experiment for rapid, on-line, real-time measurement of HBsAg by using a surface plasmon resonance biosensor to quantify the recognition and interaction of biomolecules. We immobilized the anti-HBsAg polyclonal antibody to the dextran layer on a CM5 chip surface which was pre-activated by N-hydroxysuccinimide for amine coupling. The binding of the HBsAg to the immobilized antibody was measured by the mass increase detected by the change in the SPR signal. The binding characteristics between HBsAg and its antibody followed typical monolayer adsorption isotherm. When the entire immobilized antibody was interacted, there was no additional, non-specific binding observed, which suggested the biointeraction was very specific as expected and independent of the ligand density. No significant steric hindrance was observed at 17.6 nm/$mm^2$ immobilization density. The relationship between the HBsAg concentration in the sample solution and the antigen bound to the chip surface was linear up to ca. $40\mu\textrm{g}$/mL, which is much wider than that of the ELISA method. It appeared the antigen-antibody binding was increased as the immobilized ligand density increased, but verification is warranted. This study showed the potential of this biosensor-based method as a rapid, simple, multi-sample, on-line assay. Once properly validated, it can serve as a more powerful method for HBsAg quantification replacing the current ELISA method.

Prediction of the turning and zig-zag maneuvering performance of a surface combatant with URANS

  • Duman, Suleyman;Bal, Sakir
    • Ocean Systems Engineering
    • /
    • v.7 no.4
    • /
    • pp.435-460
    • /
    • 2017
  • The main objective of this study is to investigate the turning and zig-zag maneuvering performance of the well-known naval surface combatant DTMB (David Taylor Model Basin) 5415 hull with URANS (Unsteady Reynolds-averaged Navier-Stokes) method. Numerical simulations of static drift tests have been performed by a commercial RANS solver based on a finite volume method (FVM) in an unsteady manner. The fluid flow is considered as 3-D, incompressible and fully turbulent. Hydrodynamic analyses have been carried out for a fixed Froude number 0.28. During the analyses, the free surface effects have been taken into account using VOF (Volume of Fluid) method and the hull is considered as fixed. First, the code has been validated with the available experimental data in literature. After validation, static drift, static rudder and drift and rudder tests have been simulated. The forces and moments acting on the hull have been computed with URANS approach. Numerical results have been applied to determine the hydrodynamic maneuvering coefficients, such as, velocity terms and rudder terms. The acceleration, angular velocity and cross-coupled terms have been taken from the available experimental data. A computer program has been developed to apply a fast maneuvering simulation technique. Abkowitz's non-linear mathematical model has been used to calculate the forces and moment acting on the hull during the maneuvering motion. Euler method on the other hand has been applied to solve the simultaneous differential equations. Turning and zig-zag maneuvering simulations have been carried out and the maneuvering characteristics have been determined and the numerical simulation results have been compared with the available data in literature. In addition, viscous effects have been investigated using Eulerian approach for several static drift cases.

Vibration control of small horizontal axis wind turbine blade with shape memory alloy

  • Mouleeswaran, Senthil Kumar;Mani, Yuvaraja;Keerthivasan, P.;Veeraragu, Jagadeesh
    • Smart Structures and Systems
    • /
    • v.21 no.3
    • /
    • pp.257-262
    • /
    • 2018
  • Vibrational problems in the domestic Small Horizontal Axis Wind Turbines (SHAWT) are due to flap wise vibrations caused by varying wind velocities acting perpendicular to its blade surface. It has been reported that monitoring the structural health of the turbine blades requires special attention as they are key elements of a wind power generation, and account for 15-20% of the total turbine cost. If this vibration problem is taken care, the SHAWT can be made as commercial success. In this work, Shape Memory Alloy (SMA) wires made of Nitinol (Ni-Ti) alloys are embedded into the Glass Fibre Reinforced Polymer (GFRP) wind turbine blade in order to reduce the flapwise vibrations. Experimental study of Nitinol (Ni-Ti) wire characteristics has been done and relationship between different parameters like current, displacement, time and temperature has been established. When the wind turbine blades are subjected to varying wind velocity, flapwise vibration occurs which has to be controlled continuously, otherwise the blade will be damaged due to the resonance. Therefore, in order to control these flapwise vibrations actively, a non-linear current controller unit was developed and fabricated, which provides actuation force required for active vibration control in smart blade. Experimental analysis was performed on conventional GFRP and smart blade, depicted a 20% increase in natural frequency and 20% reduction in amplitude of vibration. With addition of active vibration control unit, the smart blade showed 61% reduction in amplitude of vibration.

Nonlinearity of semiconductor optical amplifier and gain-clamping effects of Iaser-injected semiconductor optical amplifier in wavelength division mulitiplexing (파장 다중 광통신에서의 반도체 광증폭기의 비선형성과 연속파동 레이저가 입사된 반도체 광증폭기의 이득고정 효과)

  • 김동철;유건호;김형문;주흥로;한선규;주관종
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • We have numerically solved rate-equations of semiconductor optical amplifier (SOA) to understand the characteristics of SOA. The rate-equations we have used can describe injection carrier density, amplified spontaneous emission and signal photon density in spatial and time domain by dividing the cavity into multi-section. We have investigated injection carrier density, amplified spontaneous emission and signal photon density as a function of position and time in the case of single channel input in the form of square pulse. Also we have analyzed the non-linear phenomena of SOA in the case of injecting multi-channel wavelengths as in WDM. Intermodulation distortion (IMD) caused by beat among channels has significant effects on the signal distortion as the channel spacing becomes narrower, and channel crosstalk becomes larger as the power of signals increases. In the case of the injection of another CW laser whose wavelength is far enough from the signal wavelengths, the crosstalk and the output signal distortion can be significantly reduced. duced.

  • PDF

Clinical Utility of Pre-B-Cell Colony-Enhancing Factor in Bronchoalveolar Lavage Fluid of Acute Critical Ill Patients with Lung Infiltrates (폐 침윤을 동반한 급성 중증 환자의 기관지 폐포 세척액에서 측정한 Pre-B-Cell Colony-Enhancing Factor의 임상적 유용성)

  • Lee, Kwangha;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.5
    • /
    • pp.402-408
    • /
    • 2009
  • Background: Pre-B-cell colony enhancing factor (PBEF) has been suggested as a novel biomarker in sepsis and acute lung injury. We measured the PBEF in bronchoalveolar lavage (BAL) fluid of acute critically ill patients with lung infiltrates in order to evaluate the clinical utility of measuring PBEF in BAL fluid. Methods: BAL fluid was collected by bronchoscope from 185 adult patients with lung infiltrates. An enzyme-linked immunosorbent assay was then performed on the collected fluids to measure the PBEF. Results: Mean patient age was 59.9 ${\pm}$14.5 years and 63.8% of patients were males. The mean concentration of PBEF in BAL fluid was 17.5 ${\pm}$88.3 ng/mL, and patients with more than 9 ng/mL of PBEF concentration (n=26, 14.1%) had higher Acute Physiology and Chronic Health Evaluation (APACHE) II and Sequential Organ Failure Assessment (SOFA) scores on the BAL exam day. However, there were no significant differences in clinical characteristics between survivors and non-survivors. In patients with leukocytosis (n=93) seen on the BAL exam day, the linear regression analysis revealed a significant, positive relationship between PBEF and APACHE II ($r^2$=0.06), SOFA score ($r^2$=0.08), Clinical Pulmonary Infection Score ($r^2$=0.05), and plateau pressure in patients on ventilators ($r^2$=0.07) (p<0.05, respectively). In addition, multivariate regression analysis with PBEF as a dependent variable showed that the plateau pressure ($r^2$=0.177, p<0.05) was correlated positively with PBEF. Conclusion: The PBEF level in the BAL fluid may be a useful, new biomarker for predicting the severity of illness and ventilator-induced lung injury in critically ill patients with lung infiltates and leukocytosis.

Compression Strength Size Effect on Carbon-PEEK Fiber Composite Failing by Kink Band Propagation

  • Kim, Jang-Ho
    • KCI Concrete Journal
    • /
    • v.12 no.1
    • /
    • pp.57-68
    • /
    • 2000
  • The effect of structure size on the nominal strength of unidirectional fiber-polymer composites, failing by propagation of a kink band with fiber microbuckling, is analyzed experimentally and theoretically. Tests of novel geometrically similar carbon-PEEK specimens, with notches slanted so as to lead to a pure kink band (without shear or splitting cracks), are conducted. The specimens are rectangular strips of widths 15.875, 31.75. and 63.5 mm (0.625, 1.25 and 2.5 in and gage lengths 39.7, 79.375 and 158.75 mm (1.563, 3.125 and 6.25 in.). They reveal the existence of a strong (deterministic. non-statistical) size effect. The doubly logarithmic plot of the nominal strength (load divided by size and thickness) versus the characteristic size agrees with the approximate size effect law proposed for quasibrittle failures in 1983 by Bazant This law represents a gradual transition from a horizontal asymptote, representing the case of no size effect (characteristic of plasticity or strength criteria), to an asymptote of slope -1/2 (characteristic of linear elastic fracture mechanics. LEFM) . The size effect law for notched specimens permits easy identification of the fracture energy of the kink bandand the length of the fracture process zone at the front of the band solely from the measurements of maximum loads. Optimum fits of the test results by the size effect law are obtained, and the size effect law parameters are then used to identify the material fracture characteristics, Particularly the fracture energy and the effective length of the fracture process zone. The results suggest that composite size effect must be considered in strengthening existing concrete structural members such as bridge columns and beams using a composite retrofitting technique.

  • PDF

Design of Simple-structured Fuzzy Logic Systems for Quad-Copter (쿼드콥터를 위한 단순구조 퍼지논리제어시스템 설계)

  • Yoo, Hyun-Ho;Choi, Byung-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.6
    • /
    • pp.600-606
    • /
    • 2015
  • Applications of the drone have been enlarged and study on the quad-copter system has been widely progressed. Quad-copter system is raised vertically with four propellers, and it is free to move side to side, and upper and lower. It is also a typical example of non-linear systems. In this paper, we design two-input fuzzy logic control systems in order to control the quad-copter that is complex nonlinear system. And then we analyze their control rule tables and derive some characteristics that they present skew symmetric property and the control actions are enhanced as the distance from the diagonal band. This property enables the design of other control systems. We here design simple-structured fuzzy logic control systems and simulate them. We confirm some effects of the proposed systems and finally discuss about them.

Lessons Learned from a Comparative Analysis of Surgical Outcomes of and Learning Curves for Laparoscopy-Assisted Distal Gastrectomy

  • Moon, Jun-Seok;Park, Man Sik;Kim, Jong-Han;Jang, You-Jin;Park, Sung-Soo;Mok, Young-Jae;Kim, Seung-Joo;Kim, Chong-Suk;Park, Seong-Heum
    • Journal of Gastric Cancer
    • /
    • v.15 no.1
    • /
    • pp.29-38
    • /
    • 2015
  • Purpose: Before expanding our indications for laparoscopic gastrectomy to advanced gastric cancer and adopting reduced port laparoscopic gastrectomy, we analyzed and audited the outcomes of laparoscopy-assisted distal gastrectomy (LADG) for adenocarcinoma; this was done during the adoptive period at our institution through the comparative analysis of short-term surgical outcomes and learning curves (LCs) of two surgeons with different careers. Materials and Methods: A detailed comparative analysis of the LCs and surgical outcomes was done for the respective first 95 and 111 LADGs performed by two surgeons between July, 2006 and June, 2011. The LCs were fitted by using the non-linear ordinary least squares estimation method. Results: The postoperative morbidity and mortality rates were 14.6% and 0.0%, respectively, and there was no significant difference in the morbidity rates (12.6% vs. 16.2%, P=0.467). More than 25 lymph nodes were retrieved by each surgeon during LADG procedures. The LCs of both surgeons were distinct. In this study, a stable plateau of the LC was not achieved by both surgeons even after performing 90 LADGs. Conclusions: Regardless of the experience with gastrectomy or laparoscopic surgery for other organs, or the age of surgeon, the outcome was quite acceptable; the learning process differ according to the surgeon's experience and individual characteristics.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND PRELOAD OF DIFFERENT CONNECTION TYPES IMPLANT WITH INITIAL CLAMPING (임플랜트의 체결방식에 따른 초기조임력에 의한 응력분포 및 전하중에 관한 연구)

  • Lee Bum-Hyun;Chun Heoung-Jae;Lee Soo-Hong;Han Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • Statement of problem: One of common problems associated with single teeth dental implant prosthetic is the loosening of screws that retain the implants. Purpose: The maintenance of screw joint stability is considered a function of the preload achieved in the screw when the suggested initial tightening torque is applied. The purpose of this study was to investigate acquired preload after initial clamping torque for estimating screw joint stability. Material and methods: A comparative study on the effect of initial clamping of two types of implant systems with different connections was conducted Three dimensional non-linear finite element analysis is adopted to compare the characteristics of screw preloads and stress distributions between two different types of implant systems composed with abutment, screw, and fixture under the same loading and boundary conditions. Results: 1. When the initial clamping torque of 32Ncm was applied to the implant systems, all types of implants generated the maximum effective stress at the first helix region of screw. 2. Morse taper connection types of implants generate lower stress distributions compared to those by butt joint connection types or implants due to large contact surface between abutment and fixture. 3. The internal types of implant systems with friction grip type implant systems have higher resistance to screw loosening than that of the external types of implant systems since the internal types of implant systems generated larger preload than that generated by the external types for the same tightening moments.