• 제목/요약/키워드: non-linear Time history analysis

검색결과 91건 처리시간 0.027초

The development of the seismic fragility curves of existing bridges in Indonesia (Case study: DKI Jakarta)

  • Veby Citra Simanjuntak;Iswandi Imran;Muslinang Moestopo;Herlien D. Setio
    • Structural Monitoring and Maintenance
    • /
    • 제10권1호
    • /
    • pp.87-105
    • /
    • 2023
  • Seismic regulations have been updated from time to time to accommodate an increase in seismic hazards. Comparison of seismic fragility of the existing bridges in Indonesia from different historical periods since the era before 1990 will be the basis for seismic assessment of the bridge stock in Indonesia, most of which are located in earthquake-prone areas, especially those built many years ago with outdated regulations. In this study, seismic fragility curves were developed using incremental non-linear time history analysis and more holistically according to the actual strength of concrete and steel material in Indonesia to determine the uncertainty factor of structural capacity, βc. From the research that has been carried out, based on the current seismic load in SNI 2833:2016/Seismic Map 2017 (7% probability of exceedance in 75 years), the performance level of the bridge in the era before SNI 2833:2016 was Operational-Life Safety whereas the performance level of the bridge designed with SNI 2833:2016 was Elastic - Operational. The potential for more severe damage occurs in greater earthquake intensity. Collapse condition occurs at As = FPGA x PGA value of bridge Era I = 0.93 g; Era II = 1.03 g; Era III = 1.22 g; Era IV = 1.54 g. Furthermore, the fragility analysis was also developed with geometric variations in the same bridge class to see the effect of these variations on the fragility, which is the basis for making bridge risk maps in Indonesia.

정적 및 동적안전성이 우수한 SUPER concrete 100MPa 활용 부잔교 개발 (Development of static and dynamic stability utilizing superior SUPER concrete 100MPa pontoon)

  • 임형주;윤식재;이상희
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2016년도 춘계학술대회
    • /
    • pp.135-136
    • /
    • 2016
  • 초고강 콘크리트를 활용한 부잔교는 강재부잔교에 비해 부식의 염려가 없어 내구성과 동적안전성이 우수하고, 일반 콘크리트에 비해 경량구조물로 건현확보가 유리하다. 현재 국내 연구개발 결과 SUPER concrete는 100MPa까지는 강섬유의 배합없이 일반골재만으로 배합이 가능하여 고부식성 환경의 항만구조물의 내구성에 적합한 강도이다. 부잔교는 상부슬래브에 작용하는 차량(DB-18) 또는 군집하중(5kN/m2)과, 외부 벽체 및 하부슬래브에 작용하는 파력의 수평과 양력성분을 견디도록 하여야 한다. 설계 파랑은 인천 연평도지역을 대상으로 50년 빈도 유의파와 주기에 해당하는 파력을 산정하여 X,Y축 위치에 따라 수평 및 양력성분을 재하하였다. 전체계 해석시 부잔교는 연직방향 경계조건이 없는 상태에서 부력 산정이 가능하도록 기하비선형 및 시간이력해석기법을 응용하였다(Strand 7). 부잔교 슬래브에 대해서는 실물모형실험을 통해 DB-18하중 재하에 따른 안전성을 확인하였다.

  • PDF

RC 골조의 내진 보강을 위한 예압 가새의 3-D 배치 (3-D Configuration Effects of Prestressing Cable Bracing Used for Retrofitting a RC Frame Subjected to Seismic Damage)

  • 이진호;오상균;히샴 엘간조리
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.183-191
    • /
    • 2003
  • 본 연구는 예압 가새로써 내진 보강된 RC 골조의 보강 효과를 3차원적으로 조사함이 그 목적이다. 이를 위해, 먼저 4층 규모의 RC 골조에 극한 하중을 가한 후 예압 가새를 이용하여 보강하되 보강 위치에 따라 3경우로 나누어 해석을 수행해보았다. 해석 방법으로써, 본 연구자가 앞서 행한 연구 결과에 의해 정적 붕괴 해석법이 비선형 동적 시간 이력 해석법의 대안책으로 훌륭히 쓰일 수 있음을 밝힌바 있기 때문에 정적 붕괴 해석만 적용하여 보강 전의 해석 및 보강 후의 영향에 대해서 평가하였다. 그 결과, 외주부에 설치한 가새가 커다란 비틀림 저항을 발휘했으며 예압 가새로 인해 골조에 균등한 강성 변화가 유도되어 급격한 파괴가 발생하지 않는 효과를 보였다.

3차원 불균질 횡등방성 매질에 대한 탄성파 초동 주시 모델링 (Seismic First Arrival Time Computation in 3D Inhomogeneous Tilted Transversely Isotropic Media)

  • 정창호;서정희
    • 지구물리와물리탐사
    • /
    • 제9권3호
    • /
    • pp.241-249
    • /
    • 2006
  • 한국의 지질 환경은 암석 분포가 매우 다양하고 복잡한 구조 활동의 영향을 받아 지하매질의 이방성 특성이 국부적으로 심하게 변화한다. 기존의 이방성 주시 모델링의 경우 지질 모델을 2차원으로 단순화시킴으로써 이러한 복잡한 지질 환경을 제대로 고려할 수 없었다. 또한 약 이방성 가정을 사용하여 실제로 나타날 수 있는 지하 매질의 심각한 이방성 영향을 주시 모델링에서 고려할 수 없었다. 이에 이 연구에서는 보다 실제적이고 복잡한 3차원 횡등방성 매질(transversely isotropic media)에서 q-P파의 초동 주시 양상을 모사할 수 있는 주시 모델링 알고리듬을 개발하였다. 이 알고리듬에서는 2차원 비선형 주시 내삽(2D nonlinear traveltime interpolation) 기법과 주시의 3차원 격자 채움법(mapping)을 이용한 직접 전파법(direct calculation)을 통해 급격한 물성의 변화에도 주시 계산이 가능하도록 하였다. 또한, 최소 주시 계산과정에서 수치 미분을 통한 최대 경사법(steepest descent method)을 사용하여 약 이방성 가정을 극복하였다. 개발된 알고리듬은 해석해와 비교하여 그 타당성을 검증하였고 3차원 2층구조에 대한 주시 계산을 수행하여 물성이 급격히 변화하는 모델에 대해서도 안정적으로 주시 계산이 이루어짐을 확인하였다. 이 연구에서 개발한 3차원 주시 모델링 알고리듬은 향후 구조보정이나 토모그래피 알고리듬 개발에 사용될 수 있을 것으로 기대한다.

액상화 가능한 지반에 근입된 지반-말뚝-구조물 동적 상호작용의 수치 모델링 (Numerical Simulation of Dynamic Soil-pile-structure Interaction in Liquefiable Sand)

  • 권선용;유민택;김석중
    • 한국지반공학회논문집
    • /
    • 제34권7호
    • /
    • pp.29-38
    • /
    • 2018
  • 액상화 시 지반-말뚝 시스템의 동적 거동을 정확히 예측하기 위해 상용 유한 차분 프로그램인 FLAC3D를 이용하여 시간영역에서 3차원 수치 모델링을 수행하였다. 지반의 전단변형에 따른 간극수압의 발달을 직접적으로 모사하기 위해 유효응력 해석법을 이용한 액상화 모델인 Finn model을 적용하였으며 Mohr-Coulomb 탄소성 모델에 접목되어 해석이 수행되었다. 이력감쇠모델을 적용하여 지반 비선형 거동을 고려하였으며 지반과 말뚝 간의 분리현상, 미끄러짐 현상을 모사하는 인터페이스 모델을 적용하였다. 경계조건으로써 단순화 연속체 모델링 기법을 도입하여 반사파의 생성을 막고 해석 효율을 증가시켰으며 적절한 최대지반탄성계수와 항복 깊이의 설정으로 비선형 거동을 정확히 모사하고자 하였다. Wilson(1998)이 수행한 원심모형시험 케이스 중 상부지반 상대밀도가 55%인 모델을 이용하여 제안된 모델링 기법의 캘리브레이션을 수행한 결과, 수치해석으로부터 도출된 깊이 별 과잉간극수압 비-시간 이력, 휨모멘트-시간이력, 말뚝 두부 변위-시간이력이 실험 결과를 잘 모사하였다. 상부지반 상대밀도가 30%인 모델의 결과를 이용하여 제안된 모델링 기법의 적용성 평가를 수행한 결과, 수치해석으로부터 도출된 지반 및 말뚝 응답이 실험 결과를 잘 모사하였으며 제안된 모델링 기법이 지반-말뚝 시스템의 액상화 거동을 적절히 모사한다고 판단되었다.

Validation of spent nuclear fuel decay heat calculation by a two-step method

  • Jang, Jaerim;Ebiwonjumi, Bamidele;Kim, Wonkyeong;Park, Jinsu;Choe, Jiwon;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.44-60
    • /
    • 2021
  • In this paper, we validate the decay heat calculation capability via a two-step method to analyze spent nuclear fuel (SNF) discharged from pressurized water reactors (PWRs). The calculation method is implemented with a lattice code STREAM and a nodal diffusion code RAST-K. One of the features of this method is the direct consideration of three-dimensional (3D) core simulation conditions with the advantage of a short simulation time. Other features include the prediction of the isotope inventory by Lagrange non-linear interpolation and the use of power history correction factors. The validation is performed with 58 decay heat measurements of 48 fuel assemblies (FAs) discharged from five PWRs operated in Sweden and the United States. These realistic benchmarks cover the discharge burnup range up to 51 GWd/MTU, 23.2 years of cooling time, and spanning an initial uranium enrichment range of 2.100-4.005 wt percent. The SNF analysis capability of STREAM is also employed in the code-to-code comparison. Compared to the measurements, the validation results of the FA calculation with RAST-K are within ±4%, and the pin-wise results are within ±4.3%. This paper successfully demonstrates that the developed decay heat calculation method can perform SNF back-end cycle analyses.

Formulation for seismic response of a ship-block system

  • Kuchaksarai, Masoud Moghaddasi;Bargi, Khosrow
    • Structural Engineering and Mechanics
    • /
    • 제23권3호
    • /
    • pp.293-308
    • /
    • 2006
  • This paper presents a complete and consistent formulation to study the seismic response of a free-standing ship supported by an arrangement of n keel blocks which are all located in a dry dock. It is considered that the foundation of the system is subjected to both horizontal and vertical in plane excitation. The motion of the system is classified in eight different modes which are Rest (relative), Sliding of keel blocks, Rocking of keel blocks, Sliding of the ship, Sliding of both keel blocks and the ship, Sliding and rocking of keel blocks, Rocking of keel blocks with sliding of the ship, and finally Sliding and rocking of keel blocks accompanied with sliding of the ship. For each mode of motion the governing equations are derived, and transition conditions between different modes are also defined. This formulation is based on a number of fundamental assumptions which are 2D idealization for motion of the system, considering keel blocks as the rigid ones and the ship as a massive rigid block too, allowing the similar motion for all keel blocks, and supposing frictional nature for transmitted forces between contacted parts. Also, the rocking of the ship is not likely to take place, and the complete ship separation from keel blocks or separation of keel blocks from the base is considered as one of the failure mode in the system. The formulation presented in this paper can be used in its entirety or in part, and they are suitable for investigation of generalized response using suitable analytical, or conducting a time-history sensitivity analysis.

Inelastic behavior of systems with flexible base

  • Fernandez-Sola, Luciano R.;Huerta-E catl, Juan E.
    • Earthquakes and Structures
    • /
    • 제14권5호
    • /
    • pp.411-424
    • /
    • 2018
  • This study explores the inelastic behavior of systems with flexible base. The use of a single degree of freedom system (ESDOF) with equivalent ductility to represent the response of flexible base systems is discussed. Two different equations to compute equivalent ductility are proposed, one which includes the contribution of rigid body components, and other based on the overstrength of the structure. In order to asses the accuracy of ESDOF approach with the proposed equations, the behavior of a 10-story regular building with reinforced concrete (RC) moment resisting frames is studied. Local and global ductility capacity and demands are used to study the modifications introduced by base flexibility. Three soil types are considered with shear wave velocities of 70, 100 and 250 m/s. Soil-foundation stiffness is included with a set of springs on the base (impedance functions). Capacity curves of the building are computed with pushover analysis. In addition, non linear time history analysis are used to asses the ductility demands. Results show that ductility capacity of the soil-structure system including rigid body components is reduced. Base flexibility does not modify neither yield and maximum base shear. Equivalent ductility estimated with the proposed equations is fits better the results of the numerical model than the one considering elastoplastic behavior. Modification of beams ductility demand due to base flexibility are not constant within the structure. Some elements experience reduced ductility demands while other elements experience increments when flexible base is considered. Soil structure interaction produces changes in the relation between yield strength reduction factor and structure ductility demand. These changes are dependent on the spectral shape and the period of the system with fixed and flexible base.

Comparison of Inflammatory Markers Changes in Patients Who Used Postoperative Prophylactic Antibiotics within 24 Hours after Spine Surgery and 5 Days after Spine Surgery

  • Youn, Gun;Choi, Man Kyu;Kim, Sung Bum
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권6호
    • /
    • pp.834-840
    • /
    • 2022
  • Objective : C-reactive protein (CRP) level, erythrocyte sedimentation rate (ESR), and white blood cell (WBC) count are inflammatory markers used to evaluate postoperative infections. Although these markers are non-specific, understanding their normal kinetics after surgery may be helpful in the early detection of postoperative infections. To compliment the recent trend of reducing the duration of antibiotic use, this retrospective study investigated the inflammatory markers of patients who had received antibiotics within 24 hours after surgery according to the Health Insurance Review & Assessment Service guidelines and compared them with those of patients who had received antibiotics for 5 days, which was proven to be non-infectious. Methods : We enrolled 74 patients, divided into two groups. Patients underwent posterior lumbar interbody fusion (PLIF) at a single institution between 2019 and 2020. Group A included 37 patients who received antibiotics within 24 hours after the PLIF procedure, and group B comprised 37 patients who had used antibiotics for 5 days. A 1 : 1 nearest-neighbor propensity-matched analysis was used. The clinical variables included age, sex, medical history, body mass index, estimated blood loss, and operation time. Laboratory data included CRP, ESR, and WBC, which were measured preoperatively and on postoperative days (POD) 1, 3, 5, and 7. Results : CRP dynamics tended to decrease after peaking on POD 3, with a similar trend in both groups. The average CRP level in group B was slightly higher than that in group A; however, the difference was not statistically significant. Multiple linear regression analysis revealed operation time, number of fused levels, and estimated blood loss as significant predictors of a greater CRP peak value (r2=0.473, p<0.001) in patients. No trend (a tendency to decrease from the peak value) could be determined for ESR and WBC count on POD 7. Conclusion : Although slight differences were observed in numerical values and kinetics, sequential changes in inflammatory markers according to the duration of antibiotic administration showed similar patterns. Knowledge of CRP kinetics allows the assessment of the degree of difference between the clinical and expected values.

코어형태에 따른 비구조요소 내진설계를 위한 층가속도 평가 (Evaluation of Floor Acceleration for the Seismic Design of Non-Structural Elements according to the Core Shape)

  • 기호석;홍기섭
    • 한국전산구조공학회논문집
    • /
    • 제35권1호
    • /
    • pp.29-34
    • /
    • 2022
  • 최근 비구조요소의 피해사례가 증가하면서 비구조요소 내진설계에 관한 많은 연구가 진행되고 있다. 하지만 대부분의 연구는 평면적 요소보다는 수직적 요소나 시스템적 요소를 변수로 층가속도를 평가하고 있다. 때문에 본 논문에서는 횡력저항에 많은 부분을 차지하는 코어를 평면적 변수로 사용하여 비구조요소 내진설계를 위한 층가속도에 대해 평가하였다. 정사각형의 2축대칭의 평면에서 코어의 형태(위치 및 비중)변화에 따라 서로 다른 5개의 평면과 각 평면마다 5층, 10층, 15층, 20층의 층수를 가진 총 20개의 모델로 선형시간이력해석을 수행하였다. 분석 결과 코어 위치에 따라 편심을 받는 평면에서는 층가속도가 최대 1.7배의 비틀림 증폭이 발생하였고 구조물의 중층부에서 비틀림의 영향이 가장 큰 것을 확인할 수 있었다. 편심이 없이 코어의 비중만 변화한 평면에서는 주기 0.4694초를 기준으로 이하일 때는 주기가 증가할수록 층가속도가 저층부에서는 감소하고 고층부에는 증가하며, 반대로 주기 0.4694초 이상일 때는 주기가 증가할수록 층가속도가 저층부에서는 증가하고 고층부에는 감소한다는 것을 확인할 수 있었다. 또한, 구조물의 층수는 최대층가속도에 영향을 주지 못하는 것을 확인하였다.