• Title/Summary/Keyword: non-$CO_2$ gas

Search Result 316, Processing Time 0.026 seconds

Analysis of Output Voltage Properties of Non-dispersive Infrared Gas Sensors According to Ambient Temperatures (주변 온도 영향에 따른 비분산 적외선 가스센서의 출력 특성 해석)

  • Park, Han-Gil;Yi, Seung-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.294-299
    • /
    • 2018
  • This article describes the output properties of non-dispersive infrared carbon dioxide($CO_2$) sensors resulting from the changes in ambient temperatures. After the developed sensor module was installed inside the gas chamber, the temperature was set to 267 K, 277 K, 300 K, and 314 K, and the concentrations of $CO_2$ gas were increased from 0 to 5,000 ppm. Then, the output voltage at each concentration was obtained. Through these experimental results, two observations were made. First, both the $CO_2$ sensor and the reference sensor showed an increase in the output voltages as the temperature rose from 0 ppm, Second, the full scale outputs of the $CO_2$ sensor grew as the temperature increased. The output characteristics were analyzed based on two factors: change in the radiant energy of the infrared light source and change in the absorptivity of $CO_2$ gas according to the ambient temperature. Additionally, temperature compensation methods were discussed.

Effects of $CO_2$ and $H_2O$ Additions on Partially Premixed Counterflow Flame by Considering Nongray Gas Radiation (비회색 가스 복사를 고려한 층류대향류 부분예혼합 화염에서의 $CO_2$$H_2O$ 첨가에 따른 영향 연구)

  • Jo, Bum-Jin;Kim, Tae-Kuk
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.3
    • /
    • pp.10-16
    • /
    • 2005
  • Detailed flame structures of the counterflow flames of $CH_4/Air$ formed with $CO_2$ and $H_2O$ addition are studied numerically. The detailed chemical reactions are modeled by using the OPPDIF and CHEMKIN-II code. Only the $CO_2$ and $H_2O$ are assumed to participate in radiative heat transfer while all other gases are assumed to be transparent. The discrete ordinates method(DOM) and the narrow band based WSGGM with a gray gas regrouping technique(WSGGM-RG) are applied for modeling the radiative transfer through non-homogeneous and non-isothermal combustion gas mixtures generated by the counter flow flames. The results compared with the SNB model show that the WSGGM-RG is successful in modeling the counterflow flames with non-gray gas mixture. The numerical results show that the addition of $CO_2$ and $H_2O$ to the oxidant nozzle lowers the peak temperature and the NO concentration in flame.

  • PDF

Effects of gas formers of flux cored wire on spattering (FCW의 가스 발생제가 스패터링에 미치는 영향)

    • Journal of Welding and Joining
    • /
    • v.16 no.5
    • /
    • pp.93-99
    • /
    • 1998
  • Effects of gas formers of MgCO$_3$, CaCO$_3$ and Li$_2$CO$_3$ on the spattering phenomena were investigated for non-shielded flux cored arc welding. Spattering phenomena were pictured using high speed camera as a speed of 3000 frames per sec. As experimental results, spattering modes were classified into 4 types. The modes were spattering by arc force, gas explosion, short circuit and pore escape. The amount of spatters by arc force was 30%, gas blowing force was 40%, short circuit 10%, pore escape was 10% and others were 10%. When Li$_2$CO$_3$ was added, the amount of spatters was largest, and it decreased in the order of CaCO$_3$ and MgCO$_3$.

  • PDF

Temperature Dependency of Non-dispersive Infrared Carbon Dioxide Gas Sensor by using Infrared Sensor for Compensation (보상용 적외선 센서를 사용한 비분산 적외선 이산화탄소 센서의 온도특성)

  • Yi, SeungHwan
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.124-130
    • /
    • 2016
  • NDIR $CO_2$ gas sensor was built with ASIC implemented thermopile sensor which included temperature sensor and unique elliptical waveguide structures in this paper. The temperature dependency of dual infrared sensor module ($CO_2$ and reference IR sensors) has been characterized and its output voltage characteristics according to the temperature and gas concentration were proposed for the first time. NDIR $CO_2$ gas and reference IR sensors showed linear output voltages according to the variation of ambient temperatures from 243 K to 333 K and their slopes were 14.2 mV/K and 8.8 mV/K, respectively. The output voltages of temperature sensor also presented a linear dependency according to the ambient temperature and could be described with V(T)=-3.191+0.0148T(V). The output voltage ratio between $CO_2$ and reference IR sensors revealed irrelevant to the changes of ambient temperatures and gave a constant value around 1.6255 with standard deviation 0.008 at 0 ppm. The output voltage of $CO_2$ gas sensor at zero ppm $CO_2$ gas consisted of two components; one is caused by the HPB (half pass-band) of IR filter and the other is attributed to the part of $CO_2$ absorption wavelength. The characteristics of output voltages of $CO_2$ gas sensor could be accurately modeled with three parameters which are dependent upon the ambient temperatures and represented small average error less than 1.5% with 5% standard deviation.

DC Electrical Current Behavior of Calcia Doped Zirconia Under Various Oxygen Containing Gases

  • Lee, Joo-Sin;Park, Tae-Woon
    • The Korean Journal of Ceramics
    • /
    • v.3 no.1
    • /
    • pp.37-42
    • /
    • 1997
  • The DC current variation of calcia doped zirconia single crystal was measured under various oxygen containing gases at high temperatures. The DC current was influenced by the gas species for oxygen activity establishment. Also, strong non-ohmic characteristics were observed in the $CO/CO_2/N_2$ gas mixtures. Based on the experimental data obtained by introducing the non-buffering gas $N_2$ into the $CO/CO_2$ mixtures, the processes occurring at the gas/solid interface during a defect relaxation process are discussed.

  • PDF

Development of a Fast-Response $CO_2$ Analyzer using NDIR Technique and Its Application to SI Engine (비분산 적외선 흡수법을 이용한 고속응답 $CO_2$ 분석기의 제작 및 엔진 적용에 관한 연구)

  • Lee, Jae-Young;Min, Kyoung-Doug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.102-107
    • /
    • 2007
  • A fast response $CO_2$ ($fCO_2$) analyzer for real-time measurement of carbon dioxide concentration during transient states of internal combustion engines has been developed. This analyzer uses non-dispersive infrared absorption (NDIR) technique for measuring $CO_2$ concentration and Kalman filter for removing noise components from output signals. The analyzer has good linearity, repeatability and drift with a response time of 11 ms; it is sufficiently fast to detect $CO_2$ concentration during transient states of internal combustion engines. The $fCO_2$ analyzer was used to measure transient $CO_2$ concentration of exhaust gas of the SI engine with a standard gas analyzer, and the signal of the $fCO_2$ analyzer was compared to that of the standard gas analyzer. The two concentrations were well matched during the steady state, and the $fCO_2$ analyzer could measure the variations of $CO_2$ concentration during the transient state.

Temperature Measurement by Radiation Wavelength of High Temperature CO2 gas (고온 CO2 가스의 복사 파장을 이용한 부분별 온도 측정)

  • Maeng, Saeromg;Yoo, Miyeon;Kim, Saewon;Lee, Changyeop
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.315-316
    • /
    • 2014
  • Combustion gases emit various radiation signals by chemical reaction and excited molecules in combustion system. Since temperature measurement of combustion system is very difficult, non-contact temperature measuring methods are being researched. In this paper, we propose optical system of simple structure and implement technique for measuring temperature partially in furnace using radiation wavelength signals of high temperature $CO_2$ gas generated during combustion.

  • PDF

Optical waveguide structure design of Non-dispersive Infrared (NDIR) CO2 gas sensor for high-sensitivity (이산화탄소 검출을 위한 고감도 비분산 적외선 가스센서의 광도파관 구조 설계)

  • Yoon, Jiyoung;Lee, Junyeop;Do, Namgon;Jung, Daewoon
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.331-336
    • /
    • 2021
  • The Non-dispersive Infrared (NDIR) gas sensor has high selectivity, measurement reliability, and long lifespan. Thus, even though the NDIR gas sensor is expensive, it is still widely used for carbon dioxide (CO2) detection. In this study, to reduce the cost of the NDIR CO2 gas sensor, we proposed the new optical waveguide structure design based on ready-made gas pipes that can improve the sensitivity by increasing the initial light intensity. The new optical waveguide design is a structure in which a part of the optical waveguide filter is inclined to increase the transmittance of the filter, and a parabolic mirror is installed at the rear end of the filter to focus the infrared rays passing through the filter to the detector. In order to examine the output characteristics of the new optical waveguide structure design, optical simulation was performed for two types of IR-source. As a result, the new optical waveguide structure can improve the sensitivity of the NDIR CO2 gas sensor by making the infrared rays perpendicular to the filter, increasing the filter transmittance.

A Study of Consequence Analysis of Physical Explosion Damage in CO2 Storage Tank (CO2 임시 저장 탱크에서의 물리적 폭발에 따른 피해영향 고찰)

  • Seo, Doo-Hyoun;Jang, Kap-Man;Lee, Jin-Han;Rhie, Kwang-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.2
    • /
    • pp.12-19
    • /
    • 2015
  • $CO_2$ is non-flammable, non-toxic gas and not cause of chemical explosion. However, various impurities and some oxides can be included in the captured $CO_2$ inevitably. While the $CO_2$ gas was temporarily stored, the pressure in a storage tank would be reached above 100bar. Therefore, the tank could occur a physical explosion due to the corrosion of vessel or uncertainty. Evaluating the intensity of explosion can be calculated by the TNT equivalent method generally used. To describe the physical explosion, it is assumed that the capacity of a $CO_2$ temporary container is about 100 tons. In this work, physical explosion damage in a $CO_2$ storage tank is estimated by using the Hopkinson's scaling law and the injury effect of human body caused by the explosion is assessed by the probit model.