• Title/Summary/Keyword: non potable water

Search Result 10, Processing Time 0.023 seconds

A Study on Standardization Method Establishment of Multi Water-Loop System using Multi Water Resources (다중수원을 활용한 멀티워터 루프시스템의 표준화방안 구축에 관한 연구)

  • Lee, Hyundong;Lee, Joonhyung;Kwak, Pilljae
    • KCID journal
    • /
    • v.21 no.1
    • /
    • pp.109-117
    • /
    • 2014
  • Multi water-loop system is the efficient customer centered facilities of water supply by utilizing the multi water resources. Multi water-loop system is divided into various types. The system is classified potable and non-potable type. Mostly, the potable type utilizes surface water and ground water. However, the non-potable type utilize the multi water resources, such as rain water, sea water, reclaimed water, etc. Selective intake is possible when characteristics of region, physiographic condition and purpose of use are considered. For instance, downtown type, new-city type, agriculture type, island type are available. For development and application of these multi water-loop system, standardization is needed. For standardization, several methods are given; design principles, selection and composition method of multi water-loop system structure, BIM/GIS application method, safety inspection method. Consequently, a road map of design standardization method can be established. In this road map, there are three parts for the standardization of multi water-loop system. Three parts are the considerations, base material and ways of standardization. Design standardization become close when this road map followed by someone who plan the multi water-loop system. In this way, loop system's development is more efficient and economic. In hereafter research, each type's characteristic will be analysed and standardization methods can be established.

  • PDF

Municipal wastewater reclamation for non-potable use using hollow- fiber membranes

  • Waghmare, Sujata;Masid, Smita;Rao, A. Prakash;Roy, Paramita;Reddy, A.V.R.;Nandy, T.;Rao, N.N.
    • Membrane and Water Treatment
    • /
    • v.1 no.3
    • /
    • pp.207-214
    • /
    • 2010
  • Approximately 80% of water used in urban areas reappears as municipal wastewater (MWW). Reclamation of MWW is an attractive proposition under the present scenario of water stressed cities in India. In this paper, we attempted to reclaim MWW using lab-scale hollow- fiber (HF) membrane modules for possible reuse in non-potable applications. Experiments were conducted to evaluate the efficiency of virgin HF ($M_1$) and modified HF ($M_2$) modules. The $M_2$ module consists of HF modified with a skin layer formed through interfacial polymerization of m-phenylenediamine with trimesoyl chloride (MPD-TMC). The molecular weight cut-off (MWCO) of $M_1$ was 44000 g/mol and that of $M_2$ 10000 -14000 g/mol on the basis of rejection of polyethylene glycol. The combination of $M_1$ and $M_2$ modules was able to reduce concentrations of most of the pollutants in sewage and improved the treated water quality to the acceptable limits for non potable reuse applications. It is found that about 98-99% of the initial flux is recovered by the backwashing process, which was approximately two times in a month when operated continuously.

The Observation and a Quantitative Evaluation of Viable but Non-Culturable Bacteria in Potable Groundwater Using Epifluorescence Microscopy (형광현미경을 이용한 음용 지하수내 배양불능 세균의 관찰 및 정량적 평가)

  • ;Takashi Someya
    • Korean Journal of Microbiology
    • /
    • v.38 no.3
    • /
    • pp.180-185
    • /
    • 2002
  • The direct viable count (DVC) and plate count (PC) methods was used to measure the number of bacteria in potable groundwater samples collected from bottled water from the market, mineral water, and edible groundwater near the urban areas and the stock farming congested areas. As a result, the number of living bacteria by DVC was comprised 30~80% of the total direct count (TDC), whereas the number of living bacteria by PC was around l~30% of DVC. Such results show that viable but non-culturable (VBNC) bacteria exist in the potable groundwater with high percentages. On the other hand, upon measuring the value from the conventional nutrient broth (NB), $10^-2$ fold diluted nutrient broth (DNB), and R2A broth, the values from the DNB and R2A showed 2~50 times higher than the conventional NB medium. These results indicate that oligotrophic bacterial groups which can multiply in the low nutrient broth abundantly exist in the oligotrophic environment like potable groundwater.

Analysis on Rainwater Harvesting System as a Source of Non-Potable Water for Flood Mitigation in Metro Manila (마닐라의 홍수저감을 위한 잡용수 대체자원으로서의 가정용우수저류시설 분석)

  • Necesito, Imee V.;Felix, Micah Lourdes A.;Kim, Lee-Hyung;Cheong, Tae Sung;Jeong, Sangman
    • Journal of Wetlands Research
    • /
    • v.15 no.2
    • /
    • pp.223-231
    • /
    • 2013
  • Excessive precipitation, drought, heat waves, strong typhoons and rising sea levels are just some of the common indicators of climate change. In the Philippines, excessive precipitation never failed to devastate and drown the streets of Metro Manila, a highly urbanized and flood-prone area; such problems are expected to occur frequently. Moreover, the water supply of Metro Manila is dependent only to Angat Reservoir. Rainwater harvesting can serve as an alternative source of raw water and it can mitigate the effects of flooding. The harvested rainwater can be used for: potable consumption if filtered and disinfected; and non-potable consumptions (e.g., irrigation, flushing toilets, carwash, gardening, etc.) if used untreated. The rainfall data were gathered from all 5 rainfall stations located in Metro Manila namely: Science Garden, Port Area, Polo, Nangka and Napindan rain gauge stations. To be able to determine the potential volume of rainwater harvested and the potentiality of rainwater harvesting system as an alternate source of raw water; in this study, three different climatic conditions were considered, the dry, median and wet rainfall years. The frequent occurrence of cyclonic events in the Philippines brought significant amount of rainwater that causes flooding in the highly urbanized region of Metro Manila. Based from the results of this study, the utilization of rainwater harvesting system can serve as an alternative source of non-potable water for the community; and could also reduce the amount of surface runoff that could result to extreme flooding.

Assessment of Rainwater Harvesting Potential in Ibadan, Nigeria

  • Lade, Omolara;Oloke, David
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.91-94
    • /
    • 2013
  • Recently Ibadan in southwestern Nigeria has been facing severe water shortage due to the increase of population, social and economic activities. In order to meet the shortfall, attempts to utilize rainwater harvesting (RWH) have been made to provide an alternative source of water supply. A desk study was conducted to review various RWH technologies locally, regionally and globally. A hydrological analysis was also carried out using rainfall data for 30 years from two meteorological stations, with the aim of providing a more sustainable RWH system for water supply to private individuals, organizations, and government agencies. RWH is found to be technically feasible based on the prevailing rainfall pattern with over 90% of households having a rooftop constructed from technically appropriate materials. Results of the study indicate that an average roof of $80m^2$ will collect 82,835 L/yr (45 L/person/day) for a family of five people which is about the required water demand for drinking and cooking purposes. Hence, the capacity of storage tanks and the catchment area required for an all-purpose water supply system based on RWH are quite large. These can be reduced to affordable sizes, by collecting and storing water for cooking and drinking only while non-potable uses are supplemented by water from other sources. However, it must be highlighted that due to the type of roofing material, rainwater should go through proper treatment in order to be used for potable purposes. This study clearly shows that Ibadan city has a good rainwater harvesting potential.

Application of Rainwater Harvesting System Reliability Model Based on Non-parametric Stochastic Daily Rainfall Generator to Haundae District of Busan (비모수적 추계학적 일 강우 발생기 기반의 빗물이용시설 신뢰도 평가모형의 부산광역시 해운대 신시가지 적용)

  • Choi, ChiHyun;Park, MooJong;Baek, ChunWoo;Kim, SangDan
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.634-645
    • /
    • 2011
  • A newly developed rainwater harvesting (RWH) system reliability model is evaluated for roof area of buildings in Haeundae District of Busan. RWH system is used to supply water for toilet flushing, back garden irrigation, and air cooling. This model is portable because it is based on a non-parametric precipitation generation algorithm using a markov chain. Precipitation occurrence is simulated using transition probabilities derived for each day of the year based on the historical probability of wet and dry day state changes. Precipitation amounts are selected from a matrix of historical values within a moving 30 day window that is centered on the target day. Then, the reliability of RWH system is determined for catchment area and tank volume ranges using synthetic precipitation data. As a result, the synthetic rainfall data well reproduced the characteristics of precipitation in Busan. Also the reliabilities of RWH system for each of demands were computed to high values. Furthermore, for study area using the RWH system, reduction efficiencies for rooftop runoff inputs to the sewer system and potable water demand are evaluated for 23%, 53%, respectively.

Rainwater for Water Scarcity Management: An Experience of Woldia University (Ethiopia)

  • ANDAVAR, Venkatesh;ALI, Bayad Jamal;ALI, Sazan Ahmed
    • Asian Journal of Business Environment
    • /
    • v.10 no.4
    • /
    • pp.29-34
    • /
    • 2020
  • Purpose: Town of Woldia, a semi-arid region in the Northern Wollo region of Ethiopia, faces water supply shortage in general, though the town possesses a running stream of clean water throughout the year. This study is aimed at analyzing the possibility of using rainwater for water scarcity and non-potable water needs of the Woldia University. A careful study and analysis have been made to assess the feasibility of using rainwater in place of the tap water supply. Research design and methodology: This study was done inside the main campus of Woldia University located in Woldia town. The runoff water from the roof of buildings was studied, by the time of rainfall in the town. Also, the budget needed for implementing a rainwater harvesting system was calculated. Results: The findings of the study clearly indicates that the requirements of the water to use for flushing, cleaning, and washing toilets in the administrative buildings and classrooms can be satisfied by using rainwater as an alternative to tap water. Conclusion: Based on the results the study finds it is benefitable for the Woldia University to install the rainwater harvesting system at the earliest to solve the water problems prevailing in the current situation.

Influence of mixed liquor suspended solids on the removal efficiency of a hybrid membrane bioreactor

  • Palmarin, Matthew J.;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.11-22
    • /
    • 2016
  • The characterization of treatment performance with respect to mixed liquor suspended solids (MLSS) concentration enables greater control over system performance and contaminant removal efficiency. Hybrid membrane bioreactors (HMBRs) have yet to be well characterized in this regard, particularly in the context of greywater treatment. The aim of this study, therefore, was to determine the optimal MLSS concentration for a decentralized HMBR greywater reclamation system under typical loading conditions. Treatment performance was measured at MLSS concentrations ranging from 1000 to 4000 mg/L. The treated effluent was characterized in terms of biochemical oxygen demand ($BOD_5$), chemical oxygen demand (COD), turbidity, ammonia ($NH_3$), total phosphorus (TP), total kjeldahl nitrogen (TKN), and total nitrogen (TN). An MLSS concentration ranging from 3000 to 4000 mg/L yielded optimal results, with $BOD_5$, COD, turbidity, $NH_3$, TP, TKN, and TN removals reaching 99.2%, 97.8%, 99.8%, 99.9%, 97.9%, 95.1%, and 44.8%, respectively. The corresponding food-to-microorganism ratio during these trials was approximately 0.23 to 0.28. Operation at an MLSS concentration of 1000 mg/L resulted in an irrecoverable loss of floc, and contaminant residuals exceeded typical guideline values for reuse in non-potable water applications. Therefore, it is suggested that operation at or below this threshold be avoided.

A Study on the Water Reuse Systems (중수도개발연구(中水道開發研究))

  • Park, Chung Hyun;Lee, Seong Key;Chung, Jae Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.113-125
    • /
    • 1984
  • Water supply has been mainly dependent on the construction of the dams in Korea. It is difficult, however, to continue to construct dams for many reasons, such as the decrease of construction sites, the increase of construction costs, the compensation of residents in flooded areas, and the environmental effects. Water demands have increased and are expected to continue increasing due to the concentration of people in the cities, the rise of the living standard, and rapid industrial growth. It is acutely important to find countermeasures such as development of ground water, desalination, and recycling of waste water to cope with increasing water demands. Recycling waste water includes all means of supplying non-potable water for their respective usages with proper water quality which is not the same quality as potable water. The usages of the recycled water include toilet flushing, air conditioning, car washing, yard watering, road cleaning, park sprinkling, and fire fighting, etc. Raw water for recycling is obtained from drainage water from buildings, toilets, and cooling towers, treated waste water, polluted rivers, ground water, reinfall, etc. The water quantity must be considered as well as its quality in selecting raw water for the recycling. The types of recycling may be classified roughly into closed recycle systems and open recycle systems, which can be further subdivided into individual recycle systems, regional recycle systems and large scale recycle system. The treatment methods of wastewater combine biochemical and physiochemical methods. The former includes activated sludge treatment, bio-disc treatment, and contact aeration treatment, and the latter contains sedimentation, sand filtration, activated carbon adsorption, ozone treatment, chlorination, and membrane filter. The recycling patterns in other countries were investigated and the effects of the recycling were divided into direct and indirect effects. The problems of water reuse in recycle patterns were also studied. The problems include technological, sanitary, and operational problems as well as cost and legislative ones. The duties of installation and administrative organization, structural standards for reuse of water, maintenance and financial disposal were also studied.

  • PDF

Estimation of Pesticide Leaching Potential Using GUS, RF and AF Index in Cheju Citrus Orchard Soils (제주도 감귤원 토양에서 GUS, RF, AF 지수를 이용한 농약의 용탈잠재성 평가)

  • Oh, Sang-Sil;Moon, Doo-Khil;Chung, Jong-Bae;Hyun, Hae-Nam
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.1
    • /
    • pp.7-16
    • /
    • 2002
  • Contamination of groundwater by agrochemicals used in the regional-scale Is now a major environmental problem, and this is especially true for Cheju island where virtually all potable water is from groundwater. The objective of this study was to assess leaching potential of eight pesticides in soils of citrus orchards using groundwater ubiquity score (GUS), retardation factor (RF) and attenuation factor (AF). Considering GUS estimated in 30 citrus orchard soils, metribuzin and metolachlor were classified as leacher, alachlor in volcanic ash soils and linuron in non-volcanic soils were classified as leacher, but chlorothalonil and chlorpyrifos were classified as non-leacher. For RF values, metribuzin was classified to be mobile in soils of low organic carbon, metolachlor and alachlor were classified to be moderately immobile in most soils, but linuron, diuron, diniconazole, chlorothalonil and chlorpyrifos were all classified to be very immobile. For AF values, diniconazole, chlorothalonil, and chlorpyrifos were classified to be very unlikely leachable in all of the soils, metribuzin was classified to be likely leachable, and metolahclor, alachlor, linuron and diuron were classified to be leachable only in non-volcanic soils. Although there were some variations in the relative potential of teachability of pesticides estimated with the three different indices, the ranking was essentially determined on the base of the intrinsic properties of the chemicals and environmental properties. Among the eight pesticides, metribuzin, metolachlor, and alachlor, which have high water solubility and low $K_{oc}$ values, have a significant leaching potential especially in non-volcanic ash soils of low organic carbon. But diniconazole, chlorothalonil, and chlorpyrifos, which have low water solubility and high $K_{oc}$ values, were classified to be very immobile in all of the soils. Therefore, to lower the possibility of pesticide contamination of the groundwater in Cheju island, those pesticides which have high water solubility and low $K_{oc}$ values should be used with care in soils of low organic carbon including non-volcanic ash soils.