• Title/Summary/Keyword: noises

Search Result 1,949, Processing Time 0.025 seconds

Extraction of Renal Glomeruli Region using Genetic Algorithm (유전적 알고리듬을 이용한 신장 사구체 영역의 추출)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.2
    • /
    • pp.30-39
    • /
    • 2009
  • Extraction of glomeruli region plays a very important role for diagnosing nephritis automatically. However, it is not easy to extract glomeruli region correctly because the difference between glomeruli region and other region is not obvious, simultaneously unevennesses that is brought in the sampling process and in the imaging process. In this study, a new method for extracting renal glomeruli region using genetic algorithm is proposed. The first, low and high resolution images are obtained by using Laplacian-Gaussian filter with ${\sigma}=2.1$ and ${\sigma}=1.8$, then, binary images by setting the threshold value to zero are obtained. And then border edge is detected from low resolution images, the border of glomeruli is expressed by a closed B-splines' curve line. The parameters that decide the closed curve line with this low resolution image prevent the noises and the border lines from breaking off in the middle by searching using genetic algorithm. Next, in order to obtain more precise border edges of glomeruli, the number of node points is increased and corrected in order from eight to sixteen and thirty two from high resolution images. Finally, the validity of this proposed method is shown to be effective by applying to the real images.

Degenerative myopathy of the supracoracoideus (DMS) in turkeys and broiler chickens, Review (칠면조와 육계에서 청색증 발생기전에 관한 고찰)

  • Song, Hee-Jong;Lee, Myung-Woo;Ryu, Kyeong-Sun;Jang, Hyung-Kwan
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.1
    • /
    • pp.161-166
    • /
    • 2008
  • Deep pectoral myopathy (DPM), also known as Oregon muscle disease or green muscle disease, was first described in 1968 by Dickinson et al as "degenerative myopathy" in turkeys. Even though this condition was first recognized in adult meat-type turkey and chicken breeders, it is becoming more and more common in meat-type growing birds. DPM occurs exclusively in birds that have been specially selected for breast muscle development. It is generally recognized that DPM is an ischemic necrosis that develops in the deep pectoral muscle (supracoracoideus or pectoralis minor muscle) mainly because this muscle is surrounded by inelastic fascia and the sternum, which do not allow the muscle mass to swell in response to the physiological changes occurring when muscle are exercised, as in wing flapping. The lesion does not impair the general health of birds and is generally found during cut-up and deboning, moreover, it can be both unilateral or bilateral, affecting just one or both pectoralis minor muscle, respectively. No public health significance is associated to DPM, but it is aesthetically undesirable. The fillet should be removed, whereas the rest of the carcass is still fit for human consumption. However, the required trimming operations determine the downgrading of the products and produce an economic loss for the industry, especially because it affects the more valuable part of the carcass. The incidence of DPM increases with market weight in broilers, with more cases reported in higher-yielding strains and in males. Increased bird activity (flock nervousness, flightiness, struggle, and wing flapping) induced by factors such as feed or water outages, lighting programs and intensity, human activity, and excessive noises in and around chicken houses should be looked at as a trigger for the development of DPM in broiler. However, most of the studies conducted to evaluate the incidence of DPM in poultry are concerned with parental commercial breeding stocks under experimental conditions (Bianchi et al. 2006. Poult Sci 85 : 1843-1846). There is a possible genetic relationship between the selection for large-breasted birds and this condition. Management procedures that discourage excessive wing flapping would reduce the incidence (Jordan and Pattison. 1998. Poultry diseases. 398-399).

The Dynamic Basement Amplification Characteristics of a Dam Site using a Reference Site Method (기준관측소 방법을 이용한 댐체 기반암의 동적 지반증폭특성)

  • Wee, Soung-Hoon;Kim, Jun-Kyoung;Yoo, Seong-Hwa
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.161-171
    • /
    • 2017
  • Observed ground motions are composed of three factors such as, seismic source, attenuation, and site amplification effect. Among them, the site amplification characteristics should be considered significantly when estimating seismic source and attenuation characteristics with more confidence. The site effect is also necessary when estimating not only seismic hazard in seismic design engineering but also rock mechanical properties. This study uses the method of H/V spectral ratio of observed ground motion between target site and reference site called a reference site method. In addition to using the vertical Fourier spectrum of the reference site, we try out the horizontal Fourier spectrum as a new method in this study. We analyze H/V spectral ratio of six ground motions respectively, observed at four sites close to Yedang Reservoir. We then compare site amplification effects at each site using 3 kinds of seismic energies including S waves, Coda waves energy, and background noise. The results suggest that each site showed similar site amplification patterns in S waves and Coda waves energy. However, the site amplification of background noise shows much different characteristics from those of S waves and Coda wave energy, which suggests that the background noises at each site have their own developing mechanism. Each station shows its own characteristics of specific resonance frequency and site amplification properties in low, high and specific resonance frequency ranges. Comparison of the method used in this study to the others that used different methods can provide us with more information about the dynamic amplification of a site characteristics and site classification.

Low Frequency Noise and It's Psychological Effects

  • Eom, Jin-Sup;Kim, Sook-Hee;Jung, Sung-Soo;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.39-48
    • /
    • 2014
  • Objective: This entire study has two parts. Study I aimed to develop a psychological assessment scale and the study II aimed to investigate the effects of LFN (low frequency noise) on the psychological responses in humans, using the scale developed in the study I. Background: LFN is known to have a negative impact on the functioning of humans. The negative impact of LFN can be categorized into two major areas of functioning of humans, physiological and psychological areas of functioning. The physiological impact can cause abnormalities in threshold, balancing and/or vestibular system, cardiovascular system and, hormone changes. Psychological functioning includes cognition, communication, mental health, and annoyance. Method: 182 college students participated in the study I in development of a psychological assessment scale and 42 paid volunteers participated in the study II to measure psychological responses. The LFN stimuli consisted of 12 different pure tones and 12 different 1 octave-band white noises and each stimulus had 4 different frequencies and 3 different sounds pressure levels. Results: We developed the psychological assessment scale consisting of 17 items with 3 dimensions of psychological responses (i.e., perceived physical, perceived physiological, and emotional responses). The main findings of LFN on the responses were as follows: 1. Perceived psychological responses showed a linear relation with SPL (sound pressure level), that is the higher the SPL is, the higher the negative psychological responses were. 2. Psychological responses showed quadric relations with SPL in general. 3. More negative responses at 31.5Hz LFN than those of 63 and 125Hz were reported, which is deemed to be caused by perceived vibration by 31.5Hz. 'Perceived vibration' at 31.5Hz than those of other frequencies of LFN is deemed to have amplified the negative psychological response. Consequently there found different effects of low frequency noise with different frequencies and intensity (SPL) on multiple psychological responses. Conclusion: Three dimensions of psychological responses drawn in regard to this study differed from others in the frequencies and SLP of LFN. Negative psychological responses are deemed to be differently affected by the frequency, SPL of the LFN and 'feel vibration' induced by the LFN. Application: The psychological scale from our study can be applied in quantitative psychological measurement of LFN at home or industrial environment. In addition, it can also help design systems to block LFN to provide optimal conditions if used the study outcome, .i.e., the relations between physical and psychological responses of LFN.

A Study of a Module of Wrist Direction Recognition using EMG Signals (근전도를 이용한 손목방향인식 모듈에 관한 연구)

  • Lee, C.H.;Kang, S.I.;Bae, S.H.;Kwon, J.W.;LEE, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.1
    • /
    • pp.51-58
    • /
    • 2013
  • As it is changing into aging society, rehabilitation, welfare and sports industry markets are being expanded fast. Especially, the field of vital signals interface to control welfare instruments like wheelchair, rehabilitation ones like an artificial arm and leg and general electronic ones is a new technology field in the future. Also, this technology can help not only the handicapped, the old and the weak and the rehabilitation patients but also the general public in various application field. The commercial bio-signal measurement instruments and interface systems are complicated, expensive and large-scaled. So, there are a lot of limitations for using in real life with ease. this thesis proposes a wireless transmission interface system that uses EMG(electromyogram) signals and a control module to manipulate hardware systems with portable size. We have designed a hardware module that receives the EMG signals occurring at the time of wrist movement and eliminated noises with filter and amplified the signals effectively. DSP(Digital Signal Processor) chip of TMS320F2808 which was supplied from TI company was used for converting into digital signals from measured EMG signals and digital filtering. We also have used PCA(Principal Component Analysis) technique and classified into four motions which have right, left, up and down direction. This data was transmitted by wireless module in order to display at PC monitor. As a result, the developed system obtains recognition success ratio above 85% for four different motions. If the recognition ratio will be increased with more experiments. this implemented system using EMG wrist direction signals could be used to control various hardware systems.

  • PDF

Adjacent Pixels based Noise Mitigation Filter in Salt & Pepper Noise Environments (Salt & Pepper 잡음 환경에서 인접 픽셀 기반 잡음 완화 필터)

  • Seong, Chi Hyuk;Shin, Soo Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.65-71
    • /
    • 2017
  • Digital images and videos are subject to various types of noise during storage and transmission. Among these noises, Salt & Pepper noise degrades the compression efficiency of the original data and causing deterioration of performance in edge detection or segmentation used in an image processing method. In order to mitigate this noise, there are many filters such as Median Filter, Weighted Median Filter, Center Weighted Median Filter, Switching Weighted Median Filter and Adaptive Median Filter. However these methods are inferior in performance at high noise density. In this paper we propose a new type of filter for noise mitigation in wireless communication environment where Salt & Pepper noise occurs. The proposed filter detects the location of the damaged pixel by Salt & Pepper noise detection and mitigates the noise by using adjacent pixel values which are not damaged in a certain area. Among the proposed filters, the performance of the filter using the $3{\times}3$ error mask is compared with that of the conventional methods and it is confirmed that when density of noise in the image is 95%, their performances are improved as 13.24 dB compared to MF and 13.09 dB compared to AMF.

A Study on the Development of Urine Analysis System using Strip and Evaluation of Experimental Result by means of Fuzzy Inference (스트립을 이용한 요분석시스템의 개발과 퍼지추론에 의한 검사결과 평가에 관한 연구)

  • Jun, K. R.;Lee, S. J.;Choi, B. C.;An, S. H.;Ha, K.;Kim, J. Y.;Kim, J. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.477-486
    • /
    • 1998
  • In this paper, we implemented the urine analysis system capable of measuring a qualitative and semi-quantitative and assay using strip. The analysis algorithm of urine analysis was adopted a fuzzy logic-based classifiers that was robust to external error factors such as temperature and electric power noises. The spectroscopic properties of 9 pads In a strip were studied to developing the urine analysis system was designed for robustnesss and stability. The urine analysis system was consisted of hardware and software. The hardware of the urine analysis system was based on one-chip microprocessor, and Its peripherals which composed of optic modulo, tray control, preamplifier, communication with PC, thermal printer and operating status indicator. The software of the urine analysis system was composed of system program and classification program. The system program did duty fort system control, data acquisition and data analysis. The classification program was composed of fuzzy inference engine and membership function generator. The membership function generator made triangular membership functions by statical method for quality control. Resulted data was transferred through serial cable to PC. The transferred data was arranged and saved be data acquisition program coded by C+ + language. The precision of urine analysis system and the stability of fuzzy classifier were evaluated by testing the standard urine samples. Experimental results showed a good stability states and a exact classification.

  • PDF

Fast Median Filtering Algorithms for Real-Valued 2-dimensional Data (실수형 2차원 데이터를 위한 고속 미디언 필터링 알고리즘)

  • Cho, Tai-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2715-2720
    • /
    • 2014
  • Median filtering is very effective to remove impulse type noises, so it has been widely used in many signal processing applications. However, due to the time complexity of its non-linearity, median filtering is often used using a small filter window size. A lot of work has been done on devising fast median filtering algorithms, but most of them can be efficiently applied to input data with finite integer values like images. Little work has been carried out on fast 2-d median filtering algorithms that can deal with real-valued 2-d data. In this paper, a fast and simple median 2-d filter is presented, and its performance is compared with the Matlab's 2-d median filter and a heap-based 2-d median filter. The proposed algorithm is shown to be much faster than the Matlab's 2-d median filter and consistently faster than the heap-based algorithm that is much more complicated than the proposed one. Also, a more efficient median filtering scheme for 2-d real valued data with a finite range of values is presented that uses higher-bit integer 2-d median filtering with negligible quantization errors.

Development of a Three-Dimensional, Semi-Implicit Hydrodynamic Model with Wetting-and-Drying Scheme (조간대 처리기법을 포함한 3차원 Semi-Implicit 수역학모델 개발)

  • Lee, Kyung-Sun;Park, Kyeong;Oh, Jeong-Hwan
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.12 no.2
    • /
    • pp.70-80
    • /
    • 2000
  • Princeton Ocean Model (POM) is modified to construct a three-dimensional, semi-implicit hydro¬dynamic model with a wetting-and-drying scheme. The model employs semi-implicit treatment of the barotropic pressure gradient terms and the vertical mixing terms in the momentum equations, and the velocity divergence term in the vertically-integrated continuity equation. Such treatment removes the external mode and thus the mode splitting scheme in POM, allowing the semi-implicit model to use a larger time step. Applied to hypothetical systems, both the semi-implicit model and POM give nearly the same results. The semi-implicit model, however, runs approximately 4.4 times faster than POM showing its improved computational efficiency. Applied to a hypothetical system with intertidal flats, POM employing the mode splitting scheme produces noises at the intertidal flats, that propagate into the main channel resulting in unstable current velocities. Despite its larger time step, the semi-implicit model gives stable current velocities both at the intertidal flats and main channel. The semi-implicit model when applied to Kyeonggi Bay gives a good reproduction of the observed tides and tidal currents throughout the modeling domain, demonstrating its prototype applicability.

  • PDF

Speech Activity Detection using Lip Movement Image Signals (입술 움직임 영상 선호를 이용한 음성 구간 검출)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.4
    • /
    • pp.289-297
    • /
    • 2010
  • In this paper, A method to prevent the external acoustic noise from being misrecognized as the speech recognition object is presented in the speech activity detection process for the speech recognition. Also this paper confirmed besides the acoustic energy to the lip movement image signals. First of all, the successive images are obtained through the image camera for personal computer and the lip movement whether or not is discriminated. The next, the lip movement image signal data is stored in the shared memory and shares with the speech recognition process. In the mean time, the acoustic energy whether or not by the utterance of a speaker is verified by confirming data stored in the shared memory in the speech activity detection process which is the preprocess phase of the speech recognition. Finally, as a experimental result of linking the speech recognition processor and the image processor, it is confirmed to be normal progression to the output of the speech recognition result if face to the image camera and speak. On the other hand, it is confirmed not to the output the result of the speech recognition if does not face to the image camera and speak. Also, the initial feature values under off-line are replaced by them. Similarly, the initial template image captured while off-line is replaced with a template image captured under on-line, so the discrimination of the lip movement image tracking is raised. An image processing test bed was implemented to confirm the lip movement image tracking process visually and to analyze the related parameters on a real-time basis. As a result of linking the speech and image processing system, the interworking rate shows 99.3% in the various illumination environments.