Manufacturing Characteristics of Cement-Bonded Wood Composite Board as Sound Absorption Type-Noise Barrier

  • Suh, Jin-Suk;Kang, Eun-Chang;Park, Jong-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.50-56
    • /
    • 2004
  • This study was conducted to investigate the performance of sound absorption type-noise barriers manufactured with a combination of wood particles used for particleboard, recycled waste newspaper, and cement. An average density of wood-combined cement board was in the range from 0.83 to 0.96 g/cm3, showing relatively low-density board. Regardless of types of cement bonded board or wooden board, the board with concave holes(凹)-formed surfaces showed greater sound absorption coefficient compared to those of flat surface boards. The board density was not related with those coefficients. Accordingly, it was concluded that concave or deep corrugated surface structure has played an important role in sound absorption for the application of sound absorption type-noise barrier.

A Study on the Adaptive Observer/Adaptive Identifier in the Presence of Noise (잡음하에서의 적응관측자 및 적응식별기에 관한 연구)

  • 최종호;남석우
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.1
    • /
    • pp.83-91
    • /
    • 1990
  • An adaptive observer which is applicable to discrete linear time invariant systems of ARMA type in the presence of noise is proposed. It first estimates the system parameters of the MA type by applying only the system input to the observer. Then it estimates the output which corresponds to the output of the system without any noise. This is a special case of Suzuki's adaptive observer. This estimated output is applied to Suzuki's adaptive observer to estimate the system parameters of ARMA type and the states. The proposed method can make the estimate errors of the system parameters sufficiently small even in the presence of noise in the system. It can also make the estimate errors of the states of the system sufficiently small when there is no process noise. These properties of the proposed adaptive observer is certified by computer simulation.

  • PDF

Active Noise Control in a Duct Using Smart Foam (스마트 폼을 이용한 덕트 내부의 능동 소음 제어)

  • 김표재;강연준;조영만
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.422-427
    • /
    • 2001
  • In this paper is presented passive-active noise control in a duct using a ring-type smart foam. The ring-type smart foam is comprised of a PVDF film embedded in elastic noise control foam of lining shape. The embeddedPVDF element acts as an actuator to reduce noise at lower frequencies and the foam absorbs noise at higher frequencies. By implementing an adaptive filtered-x LMS algorithm, experiments are performed to reduce both tonal and broadband noise in a duct with one end closed and the other end open.

  • PDF

Traffic Noise Reducing Technology using RSBS(Radial type SBS) Modifiers Into Double Layer Pavement (RSBS(Radial type SBS)를 이용한 복층포장구조에 의해 도로교통소음을 저감하는 기술)

  • Kim, Byung Chae;Park, Jin Su;Hwang, Kyung Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.568-572
    • /
    • 2013
  • This is traffic noise reducing technology with higher porosity and durability by using small aggregate in upper layer and big aggregate in lower layer utilizing RSBS modifier. We can reduce average 9dB(A) of traffic noise compare to normal pavement by double layer structure with higher durability using small gap over bigger gap. Also, it increases a porosity more than 22% with more durability by RSBS modifier.

  • PDF

Active Noise Control in a Circular Duct Using Smart Foam (원형 덕트 내에서 스마트 폼을 이용한 능동 소음 제어)

  • Han, Je-Heon;Kim, Pyo-Jae;Kang, Yeon-June
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.641-645
    • /
    • 2001
  • In this paper, it is discussed that active noise control in a circular duct using smart foam. Firstly, it is demonstrated that the potential of the conventional smart foam, proposed by Fuller, for active noise control in a duct. Conventional smart foam is not applicable to active noise control in a duct having flow. Thus, this paper presents a ring-type smart foam as an alternative. The ring-type smart foam consists of polyurethane acoustic foam of lining shape and PVDF film embedded in the foam. The embedded PVDF element acts as an actuator to reduce noise at lower frequencies and the foam absorbs noise at higher frequencies. A filtered-x LMS controller is used to minimize the signal from the error microphone. Experiments are executed to reduce broadband and tonal noise.

  • PDF

A Study on Reduction of Refirigerant Noise in Household Refrigerator (냉장고 냉매 소음의 저감에 관한 연구)

  • Choi, Seong-Won;Hwang, Won-Gul;Sul, Seoung-Yun;Im, Hyung-Eun;Kim, Sang-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1062-1066
    • /
    • 2004
  • In this study, refrigerant noise at connection of capillary tube and evaporator is investigated. Mechanism of refrigerant noise generation is examined in side-by-side type home refrigerator with two evaporators. It is found that the refrigerant noise is generated during refrigeration room fan-off (R-fan of) for that type refrigerator. The reason is that mass flow rate gets down during R-fan of and flow pattern is changed at outlet of capillary tube. We suggest designs for reduction of refrigerant noise with horizontal double expansion device, muffler, and accumulator. To evaluate those improved designs, sound quality index is used.

  • PDF

A Study on The Improvement Effects of Road Traffic Noise by The Noise Barrier Facilities Using a Noise Map Simulation (소음지도를 활용한 방음시설별 도로교통소음 개선효과에 관한 연구)

  • Jeong, Jea-Hun;Park, Jin-Ho;Kwon, Woo-Taeg;Kim, Hyung-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.4
    • /
    • pp.213-224
    • /
    • 2008
  • Since 1970's rapid urbanization and economic growth, the population was highly increased and residential type was changed from single detached house to high density and high-rise apartment. Recently more high-rise residential building generates more traffic volumes and it makes spatial concentration. The highly traffic volumed road and high residential building was constructed nearby, it occurs noise problem. The purpose of this study is comparing the performance of three type noise barrier between noise source and receiver using a noise map simulation. Three types were composed as road side planting trees, building side planting trees and noise barrier wall. Planting trees is less effective than noise barrier wall as a noise barrier. And they are all effective under 3 stories than over 5 stories, especially noise barrier function can't work over 5 stories.

A Study on Radiation Characteristics of Noise Sources for Korean Train Express (한국형 고속철도의 소음 방사특성에 관한 연구)

  • Kim, Jae-Chul;Koo, Dong-Heo;Moon, Kyeong-Ho;Lee, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.323-327
    • /
    • 2002
  • In order to control the railway noise, the radiation characteristic of the noise during the train passage should be analyzed. Generally, the major noise sources for Korean Train Express are the rolling noise and power unit noise up to 300km/h. In this paper, we describe on a train model that is considered to be a row of point sources to calculate the radiation characteristic. The calculation results are compared with short distance measurement. It is shown that the radiation characteristic of the rolling noise is dipole type. The noise generated by the power unit is radiated as the cosine type. The noise level at an observer is increased in the direction of motion and reduced in the direction opposite to the motion with increasing of the train speed. The calculation results including the moving effect of the noise source at 300km/h show in good agreement.

  • PDF

Environmental Noise Prediction and Countermeasures for Packaged Power Station (육상용 디젤엔진 발전플랜트의 환경소음 영향 평가 및 저감 대책)

  • Song, Keun-Bok;Kim, Won-Hyun;Kim, Dong-Hae;Bae, Jong-Gug
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.6-11
    • /
    • 2007
  • Packaged power station (PPS) is a stationary diesel engine generator set and developed for the supply of electric power to small villages, islands and factories etc. Therefore, the PPS is closely installed to residence area and sometimes cause the environmental noise problems. In this paper, environmental noise analysis was performed for the power plant with 28 sets of PPS. The initial analysis results showed the some difference between the measurement and analysis because of the inaccurate noise source data. To improve the accuracy of analysis, main noise sources were inversely estimated using the in-situ measurement data in the vicinity of PPS and steam boiler. As the results of re-analysis, the good agreement was obtained and it was concluded that the noise levels exceed the specified noise limit in residence area. In order to reduce the noise, the several methods such as geometry alteration of inlet duct, application of hybrid-type silencer and noise protection barrier were suggested and verified with the confirmed analysis model.