• 제목/요약/키워드: noise type

검색결과 2,638건 처리시간 0.031초

아파트의 내부 생활소음레벨 및 소음종류 실태 (Present Condition on Noise Level and Types Including Residents' Living Noise in Apartment Units)

  • 최윤정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.427-430
    • /
    • 2008
  • The present study is a preliminary research improving the dwelling quality of apartment house as a kind of multi-family housing. The purpose of the study is to find out the present condition on noise level and types including residents' living noise in apartment units. The method was field survey consisted of field measurements on equivalent noise level, observation on noise type, and interview on residents' responses. The results are as follows. 1) Averages of indoor noise levels of subject houses were measured as $43.9{\sim}62.2\;dB(A)_{Leq5min}$, the average of each house except one was higher than the permissible level, 45 dB(A). 2) The noise types observed were mostly residents' living noise and classified as 'water hammer', 'living equipment noise', 'noise by family', 'hood noise', and 'kitchen noise' in own unit, 'walking and talking noise in stairs and corridors', 'noise by neighborhood house', 'noise by the upper story' in building, and outdoor noise. 3) The residents show slightly non-positive responses at 'noise by the upper story', 'noise by neighborhood house', 'water hammer', and 'noise by family'. Therefore, it is required to plan for preventing deterioration of the sound environment quality by residents' living noise in own unit as well as by neighborhood houses.

  • PDF

건설공사장 이동식 방음시설물의 음향특성 (Site Mitigation Plan for Noise Sources from Construction Sites by Developing Movable Noise Barriers)

  • 이성찬;정진연;임정빈
    • 한국소음진동공학회논문집
    • /
    • 제25권1호
    • /
    • pp.58-64
    • /
    • 2015
  • There are a lot of different types of noise from construction site and it depends on construction stage, equipment type and number of operating equipments. The problem is that the almost noise from construction site is high level and some kinds of noise levels are over 100 dB. In addition, if construction site is located in downtown, there are a few options to reduce noise level. Therefore several site mitigation plans were developed to reduce different types of construction noises such as breaker work, gang form and asphalt saw. They were applied in site and evaluated noise reduction performance. The test result of site insertion loss was between 4~8 dB depends on the equipment and type of work.

Mixed Weighted Filter for Removing Gaussian and Impulse Noise

  • Yinyu, Gao;Kim, Nam-Ho
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.379-381
    • /
    • 2011
  • The image signal is often affected by the existence of noise, noise can occur during image capture, transmission or processing phases. noises caused the degradation phenomenon and demage the original signal information. Many studies are being accomplished to restore those signals which corrupted by mixed noise. In this paper, we proposed mixed weighted filter for removing Gaussian and impulse noise. we first charge the noise type, then, Gaussian is removed by a weighted mean filter and impulse noise is removed by self-adaptive weighted median filter that can not only remove mixed noise but also preserve the details. And through the simulation, we compared with the conventional algorithms and indicated that proposed method significant improvement over many other existing algorithms and can preserve image details efficiently.

  • PDF

Cascode Low Noise Amplifiers with Coplanar Waveguide Structure for Wireless LAN Application

  • Kim, Jong-Ho;Kim, Ki-Byoung;Lee, Jong-Chul;Kim, Jong-Heon;Lee, Byungje;Kim, Nam-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제3권1호
    • /
    • pp.12-16
    • /
    • 2003
  • In this paper, low noise amplifiers with coplanar waveguide structure are presented for Wireless LAN data communication application. For comparison of microwave performance, LNAs of cascode type and balanced type using cascode cell with the same substrate and same bias conditions are designed and implemented. A cascode type of LNA shows the gain of 12.45 ㏈, input return loss of 11.63 ㏈, and noise figure of 1.52㏈. A balanced type of LNA using cascode cell shows the gain of 6.58 ㏈, input return loss of 16.6 ㏈, and noise figure of 1.18 ㏈.

피스톤 펌핑 위상이 텐덤형 사판식 액셜 피스톤 펌프의 진동 ${\cdot}$ 소음에 미치는 영향에 관한 연구(1) (A Study on Effects of Piston Pumping Phase on Vibration and Noises of Tandem Swash Plate Type Axial Piston Pump(1))

  • 박성환;이진걸
    • 한국정밀공학회지
    • /
    • 제16권5호통권98호
    • /
    • pp.74-82
    • /
    • 1999
  • To meet the needs of the hydraulic excavator of large capacity, tandem axial type piston pump which is high pressure and high speed have been developed. But inevitably we can not help facing the problem of noise at that time. In order to reduce the noise of this pump, many researchers have been studying the problem of oil distribution manner. But they are not interested in the symmetric structure of tandem type pump. So, focusing on the symmetric structure of tandem type pump, this paper analyzed unbalanced force developed in the pump chamber and verified the effect of the pumping phase of the piston on vibration and noise of the tandem axial type piston pump theoretically.

  • PDF

다구찌 법을 이용한 에어컨용 회전압축기 공명기에 관한 실험적 연구 (Experimental Analysis Using Taguchi Method on the Resonator in the Rotary Compressor for Air Conditioner)

  • 이병찬;김진동
    • 한국소음진동공학회논문집
    • /
    • 제14권1호
    • /
    • pp.3-9
    • /
    • 2004
  • This paper introduces the experimental analysis of the resonator in the rolling piston type compressor for air conditioner. The resonator located between cylinder and hearing is a major factor in the noise reduction of the rotary compressor. Several shapes for the resonator which can be built in the space limitations are derived. Then optimal resonator type for the noise reduction is determined by noise tests. 6 design parameters of the type are found and optimal level for each design factor is deduced from Taguchi method.

고속철도와 일반철도소음의 성가심 반응에 대한 청감실험 비교 연구 (Jury Evaluation Test for Annoyance Response of KTX (Korea Train Express) and Ordinary Train Noise)

  • 전형준;김득성;고준희;이건;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1134-1139
    • /
    • 2007
  • In recent years, public complaints about railroad noise by KTX and Ordinary train are increasing. Restriction of railways uses same standard without distinguishing the type of railways. According to the type of railways, the frequency characteristics of emitting noise is different. Therefore it is requested to know how vary the public response to each types of railway. The noise annoyance to three types of trains (KTX, Electric train, Diesel train) was analyzed by Jury Evaluation Test for assessing the effect of frequency characteristics. The numerical results by a Semantic Differential Method showed that annoyance response to three type of trains depended on the frequency characteristics. As a result, this study proposed that the KTX could have a bonus level of maximum 2.9dB(A) to ordinary train.

  • PDF

다공판이 내장된 반사형 소음기의 소음저감 성능 (Noise Reduction Performance of a Reactive type Silencer with Perforated Panels)

  • 이선기;이영철;송화영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1415-1418
    • /
    • 2007
  • When a high voltage COS fuse becomes a short circuit by the over current, the impulse noise over 150 dB(A) with the strong pulse jet is radiated from the COS fuse of an electric transformer. For the purpose of the impulse noise reduction, in this study, a reactive type silencer with perforated panels are considered. The transmission loss of the silencer are calculated by transfer matrix method. The effect of the porosity, the distance between panels, and the number of perforated panel on the sound transmission loss is investigated and discussed.

  • PDF

드럼세탁기 방사소음의 소스 및 기여도 분석 (Analysis of Sources and Contribution for the Radiated Noise of Drum-type Washing Machine)

  • 김지만;정병규;허소정;안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제24권8호
    • /
    • pp.628-635
    • /
    • 2014
  • The procedure to estimate the sources of noise and vibrations in a typical drum-type washing machine was presented. The sources should be identified to predict the radiated noise with computational model of structure. Source identification techniques based on singular decomposition were implemented using the measured signals of accelerometers and microphones. The finite element analysis and indirect boundary element analysis were implemented to predict the structural vibrations and the acoustic pressures at the field points. The predicted results by only structural sources were compared with those by both structural and acoustical sources. It was verified that not only the structural-borne source but also air-borne source should be considered to predict the radiated noise with better accuracy. The contribution analysis with respect to the transfer path was also preformed.