• 제목/요약/키워드: noise source

검색결과 2,336건 처리시간 0.029초

평탄부 선로에서 철도소음의 전파예측에 관한 연구 (A Study on the Predition of Train Noise Propagation from a Level Railroad)

  • 주진수;박병전
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.187-194
    • /
    • 1998
  • In order to predict the train noise propagation from a level railroad, this paper presents the model of train noise source and the prediction model based on the results by using the sound intensity method. The prediction model gives the effects of geometric attenuation, ground attenuation, and barrier attenuation of noise. There are several principal assumption in developing model: (a) the train noise is primarily rolling noise; (b) the rail head and wheels are in good condition; (c) the height of source is 10cm above track; (d) the directivity pattern of train noise sources is a dipole source. Calculated results based on this model are compared with available field data and good agreement has been obtained.

  • PDF

Blind 신호원 분류를 갖는 능동 소음 제거기 (An Active Noise Canceller with Blind Source Separation)

  • 손준일;이민호
    • 한국음향학회지
    • /
    • 제18권6호
    • /
    • pp.3-8
    • /
    • 1999
  • 본 연구에서는 신호원에 대한 사전 정보 없이 혼합된 신호로부터 잡음 신호만을 선택적으로 제거할 수 있는 새로운 형태의 능동 소음 제거기(Active noise canceller)를 제안한다. 음성신호와 같은 동특성을 갖는 신호의 분리에 효과적으로 사용되는 동적 재귀 신경망(Dynamic recurrent neural network)을 원하는 신호원에 섞인 잡음신호를 분리하여 선택적으로 제거하기 위한 능동 소음 제거기의 전처리기로 이용한다. 능동 소음 제거기는 분리된 잡음 신호에 대한 역위상 신호를 적응적으로 발생함으로써 특정 위치에서 원하는 신호만을 선택적으로 남길 수 있도록 한다. 컴퓨터 시뮬레이션을 통하여 제안된 시스템이 선택적인 소음제거에 효과적임을 보인다.

  • PDF

왕복동식 공기압축기의 소음 발생원 분석 연구 (Noise Source Evaluation for Reciprocating Type Air Compressor)

  • 이광길;최승주
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.20-26
    • /
    • 2011
  • This paper is to investigate noise source for reciprocating type air compressors. The reciprocating type air compressors are widely used in the small and medium sized enterprise and many employees are affected and irritated by their noise during working. The investigation and analysis of the noise source were made according to the ISO 1680/1 and MIL-STD 7410-1 and noise evaluation of each part of compressors was made. Noise emitted from the intake and exhaust valve and the air receiver tank were dominant compared with those from other parts of compressor. Noise from the motor and the revolution of crank mechanism was negligible relatively with the noise sources as mentioned above.

Study on Noise Reduction of AV Projector

  • Kim, Sang-Hoon;Bok, Ki-So;Lee, Seung-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1155-1158
    • /
    • 2007
  • To reduce acoustic noise level of an AV projector, primary noise sources of AV projector were analyzed. Based on the analyzed result, methods to control each source are presented and tried. Structure-borne noise can be controlled by anti vibration design of mounting system, and air-borne noise by reducing flow resisitvity.

  • PDF

부산 지하철 2호선 소음 특성 연구 (The Study of Sound Level Specification of Subway Line II in Busan)

  • 정경원;윤나나;김주인;곽진;김영태
    • 한국환경과학회지
    • /
    • 제15권3호
    • /
    • pp.287-292
    • /
    • 2006
  • The purpose of this paper is to evaluate the noise level and source, reduce the subway line II noise. As a result of measurement of subway line II in Busan the highest value section of uproad line was from Jigegol to Motgol by 89 dB(A). The sections of conversation and listening interference(over 80 dB(A)) were 21 sections(55%) of 38 sections. Among these sections, 15 sections(71%) were produced rolling noise, 3 sections(14%) squeal noise, 2 sections(10%) braking noise and 1 section(5%) fan noise, and then a main noise source was the rolling noise. In case of downroad line, the highest value section was from Busan Metro Art Museum to Centum city, Motgol to Jigegol by 88 dB(A). The sections of conversation and listening interference(over 80 dB(A)) were 18 sections(47%) of 38 sections. Among these sections, 15 sections(83%) produced rolling noise, 2 sections(11%) squeal noise and 1 section(6%) braking noise were investigated in this study. and then a main noise source was the rolling noise.

On the Linear Harmonic Analysis of Engine Exhaust and Intake Systems

  • Peat, Keith
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.27-33
    • /
    • 2001
  • Linear harmonic analysis is a convenient and generally accurate method to use for the acoustic analysis of intake and exhaust silencers for IC engines. The major uncertainty in this form of modelling is the characterisation of the source, which is inherently nonlinear and time-variant. Experimental methods are generally used to determine the source characteristics, and in particular the indirect method is most suitable for an IC-engine source. With reference to an idealised linear time-variant source, it is found that the characteristics of a time-variant source as determined by the indirect method have no physical relevance. The direct method of experimental measurement appears to have some advantage over the indirect method, although in practice it is difficult to apply to an IC engine source. Again, an idealised linear time-variant source can be used to indicate that the characteristics of a time-variant source as determined by the direct method also have no physical relevance. Strangely, these meaningless measured source properties can nevertheless be used to accurately predict the radiated noise from an IC engine and silencer system.

  • PDF

Duct ANC 시스템에서 2차음원 방향별 소음감소효과 (An attenuation effect of noise according to the direction of secondary sound source in duct ANC system)

  • 이형석;이응석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.497-502
    • /
    • 2008
  • In this paper, we studied on an attenuation effect of automobile exhaust noise according to the direction of secondary sound source in duct ANC system. Automobile exhaust noise was recorded at 800rpm. 3500rpm and 5000rpm of a diesel engine. Directions of loudspeaker(second sound source) can be exchanged to $30^{\circ}$, $90^{\circ}$ and $150^{\circ}$ against the primary noise flow by acrylic ducts to be made for experimentation. DSP board with TMS320C6416 chip of Texas Instrument Co used to control adaptive ANC system. This ANC system is based on the single-channel FxLMS algorithm. In experiment result, when the loud speaker direction was $150^{\circ}$, the attenuation effect showed largely. In case of $90^{\circ}$ duct, the noise was a little increased. In case of $30^{\circ}$ duct, the noise was a little increased or decreased according to the frequency range and the sound pressure(dB) of exhaust noise to comply with engine rpm.

  • PDF

복소음향인텐시티법을 이용한 HVAC의 소음원 검출 (Identification of Noise Source of the HVAC Using Complex Acoustic Intensity Method)

  • 양정직;이동주
    • 한국소음진동공학회논문집
    • /
    • 제20권11호
    • /
    • pp.1089-1096
    • /
    • 2010
  • The relation between the vibration induced from machinery and the radiated sound is complicated. Acoustic intensity method is widely used to obtain the accuracy of noise measurement and noise identification. In this study, as groundwork, the complex acoustic intensity method is performed to identify noise source and transmission path on different free space point source fields. As an industrial application, the complex acoustic intensity method is applied to HVAC to identify sound radiation characteristics in the near field. Experimental complex acoustic intensity method was applied to HVAC, it is possible to identify noise sources in complicated sound field characteristics which noise sources are related with each other, and certificate the validity of complex acoustic intensity. Especially, it can be seen that complex acoustic intensity method using both of active and reactive intensity is vital in devising a strategy for identification of noise. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

오리피스 구조내에서 발생한 공동소음의 음향학적 스케일링에 관한 연구 (A study on the acoustic scalings of cavitation noise in an orifice configuration and a constant flow control valve)

  • 이재환;이승배;유선학
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.81-89
    • /
    • 1999
  • The major source of noise in the process of transporting liquids is related to the cavitation phenomenon. The control valve noise is mostly dominated by bubble dynamics under cavitating conditions. In this investigation, an orifice configuration is set-up to correlate its flow-field and acoustic signatures with those from a control valve device. The performance and noise characteristics form the orifice configuration in anechoic surroundings were measured to reveal the noise sources depending on pressure differences across the orifice configuration. The sound powers from the orifice configuration are effectively normalized using proposed scaling parameters. Flow-excited dynamic systems for which there is no strong coupling between the flow and the system response can be described using a linear source-filter model. On this assumption, the normalized sound powers can be decomposed of noise source function and a response function. To find noise sources, pressure spectra measured over a range of pressure differences are transformed into the product of two non-dimensional frequency function : $P_{ss}(He,f_{ca},x/D) = F(f_{ca})\;G(He,x/D)$. This scheme of finding noise sources is shown to be applicable to the cavitation noise from the control valve effectively Two kinds of cavitating modes based on our experimental data are found and discussed.

  • PDF