• Title/Summary/Keyword: noise occur

Search Result 406, Processing Time 0.032 seconds

Regression Analysis of an Excavator Sound Power Level (굴착기의 음향파워레벨 회귀분석)

  • Gu, Jin-Hoi;Lee, Jae-Won;Seo, Chung-Youl;Jang, Seong-Ki;Choi, Kyung-Hee;Han, Jin-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.3
    • /
    • pp.203-207
    • /
    • 2012
  • The noise emitted from an excavator has long been a cause of environmental disputes, while causing displeasure to the nearby residents. So, the ministry of environment adopted the construction machinery noise labeling system to encourage the construction machinery manufacturing companies to develop the low noise construction machinery voluntarily. But, as the quality of life improves, a growing number of people desire the comfortable and quite environment to live in. Under the situation, noise from the construction machinery has been a major cause for stress and complaints. When the noise dispute happened in the construction site, the sound pressure level of the construction machinery like a excavator was measured at the lot boundary of the noise victim's residence to judge how much noise damage occur. But the sound pressure level of the construction machinery is measured differently according to the acoustic environment of construction site and the measuring position, respectively, which makes it difficulty to judge whether the noise damage occur or not. As the sound power level of noise source is not affected by the acoustic environment of construction site and the measuring position, if we use the information of the sound power level, it will be easy to judge whether the noise damage occur and to establish the soundproofing measures. Therefore, we derive the sound power level regression model of the excavator to judge whether the noise emitted from the excavator damages to residents near the construction site. Also, the sound power level regression model of the excavator drawn in this paper will help construction companies to plan the noise reduction program in the construction sites.

A Study on Vibration and Noise through Finite Element Analysis of Large High Speed Press (대형 고속프레스의 유한요소해석을 통한 진동 및 소음에 대한 연구)

  • Seung-Soo Kim;Chul-Jae Jung;Chun-Kyu Lee
    • Design & Manufacturing
    • /
    • v.17 no.4
    • /
    • pp.14-23
    • /
    • 2023
  • The electric vehicle market is developing rapidly around the world. Also, parts of electric vehicles require precision.In order to produce high-precision motor cores,Press equipment must also have good precision. Drive motor cores are an important technology for electric vehicles. It uses a large high-speed press to mass-produce drive motor cores. Because it's a large high-speed press, there are many reasons why the precision is not good. One of the causes is vibration and noise. Recently, as environmental demands have become stricter, regulations on noise and vibration have been strengthened. It is important for press machines to reduce vibration first for sound insulation and dust proofing. This is because the "breakthrough" phenomenon occurs in the press. Dynamic precision is the precision under the load of the press, Design considering strain and stiffness shall be made. Vibration and noise may occur due to SPM of high-speed press,And vibration and noise can cause structural deformation of the press. Structural deformation of the press can affect the precision of the product.Noise and vibration also cause problems for workers and work environments. Problems with vibration and noise occur during press processing, and vibration and noise lead to damage to the mold or defects in the product. Reliability in high-quality technology must be secured with low noise and low vibration during press processing. Modular shape and deformation energy effects were analyzed through finite element analysis. In this study, a study on vibration and noise countermeasures was conducted through finite element analysis of a large high-speed press.

The Trouble Analysis of Electric wave Antenna Using GIS (GIS를 이용한 전파안테나 장애분석)

  • Kang, Joon-Mook;Kang, Young-Mi;Choi, Joon-Seuk;Lee, Ju-Dae
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.2 s.29
    • /
    • pp.3-9
    • /
    • 2004
  • The Broadcasting system is very important part of human lift that preceding to people news, nation plan, sport, drama, leisure and politics. The product of maded by brocasting system conveyed the whole country by radio signal. A brocasting station operate the brocast product radio trial network in the mountain. Recently a height of new building, concrete structure is very large and higher then old one. Since one does or says, noise occur to radio and TV signal whole nation. In this study, Taejun Sikjang mountain and Cheunan-Heuksung mountain where occurred radio noise chosen as a sample, and analysis 3D simulation and plane check. Accordingly come to conclusion condition of noise occurred radio antenna.

  • PDF

Analysis of curve squeal noise for KTX train (KTX 차량 곡선부 스퀼 소음 특성)

  • Lee, Chan-Woo;Kim, Jae-Chul
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1187-1190
    • /
    • 2009
  • CURVE SQUEAL NOISE IS THE INTENSE HIGH FREQUENCY TONAL THAT CAN OCCUR WHEN A RAILWAY VEHICLE TRAVERSES A CURVE OR A SWITCH. THE HIGH NOISE LEVEL CAUSES ANNOYANCE FOR PEOPLE WHO LIVE IN THE NEIGHBOURHOOD OF THE SQUEALING RAILWAY TRACK AS WELL AS FOR THE PASSENGERS IN CARS WITH CURVES. THIS PAPER EXAMINES THE SPECTRAL SOUND DISTRIBUTION IN CURVES FOR KTX TRAIN. THE FREQUENCY RANGE IS FROM AROUND 4,000 TO ALMOST 16,000Hz, WITH NOISE LEVELS UP TO 92dB IN CURVE R400.

  • PDF

An interior noise characteristic analysis of Busan Metro Line 3 (부산 도시철도 3 호선 실내소음 특성분석)

  • Ahn, Chan-Woo;Hong, Do-Kwan;Han, Geun-Jo;Gang, Hyeon-Uk;Lee, Kwon-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.362-367
    • /
    • 2010
  • This paper deals with the correlation between the interior noise and the floor vibration of the train from rolling, impulse and friction in Busan Metro line 3. The correlation is verified by sound and vibration measurement causing friction between the railway and the wheel. If ANC(Active Noise Control) system can reduce 5 dB in below 500 Hz, the sound pressure level of the whole band pass can be reduced about 1.8-4.8 dB in squeal noise. Curve squeal noise is the intense high frequency tonal that can occur when a railway vehicle transverses a curve. The frequency range is from around 500 to almost 20,000 Hz, with noise levels up to about 15 dB in curve.

  • PDF

Mixed Weighted Filter for Removing Gaussian and Impulse Noise

  • Yinyu, Gao;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.379-381
    • /
    • 2011
  • The image signal is often affected by the existence of noise, noise can occur during image capture, transmission or processing phases. noises caused the degradation phenomenon and demage the original signal information. Many studies are being accomplished to restore those signals which corrupted by mixed noise. In this paper, we proposed mixed weighted filter for removing Gaussian and impulse noise. we first charge the noise type, then, Gaussian is removed by a weighted mean filter and impulse noise is removed by self-adaptive weighted median filter that can not only remove mixed noise but also preserve the details. And through the simulation, we compared with the conventional algorithms and indicated that proposed method significant improvement over many other existing algorithms and can preserve image details efficiently.

  • PDF

A Study of Noise Sources Analysis for High Speed EMU (분산형 고속철도 차량의 소음원 분석 연구)

  • Hong, Yun-Hyuck;Kim, Jeung-Tae;Kim, Jung-Soo
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1026-1032
    • /
    • 2010
  • In this paper, To estimate the train exterior noise and environment noise which are occur when High-Speed EMU is driving with the speed of 370km/h, Estimated sound source about noise that is appeared during operation based upon noise SPL values. Based on aero-dynamic noise source and wheel-rail noise source, these were already used to the existed research, we have estimated each sound power about measured noise, and computed the sound source to apply on the High-Speed EMU, and also calculated the sound power in case of the maximum operation speed of 370km/h.

  • PDF

A Study on the Noise Performance of Silencer Fused with Hole-Cavity Resonance Technology and Micro-Sphere Stainless Chip Sintering Technology (Hole-Cavity 공명기술과 미세공 스테인레스칩 소결 융합 소음기의 소음성능에 관한 연구)

  • Cho, Dong-Hyun;BacK, Nam-Do
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.101-108
    • /
    • 2019
  • In this study, the hole-cavity resonance technology and the micro pore stainless chip sintering technology were fused to develop silencers with excellent noise attenuation performance even at fluid pressures exceeding 30 bar for the first time at home and abroad. As a result of this study, the noise attenuation performance was greatly improved as reflection, loss, and resonance were made to occur thousands of times simultaneously when fluids pass through the sintered micro pore stainless steel chip sound absorber. The noise of the gas emitted from the bomb without the silencer was shown to be 125dB. And noise test conducted after installation of the silencer showed the noise of 67dB. Given the study results, the amount of noise was greatly reduced in the sintered silencer.

Measurements and Evaluations of a Maglev Train Noise (자기부상열차 소음 측정 및 평가)

  • Kim, Hyun-Sil;Kim, Sang-Ryul;Kim, Bong-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.763-766
    • /
    • 2006
  • The principal of a Maglev train is that floats on a magnetic field and is propelled by a linear induction motor. One of advantages is that it generates less noise compared to the wheel-on-rail train, because there are no wheels running along the rail. However, noises due to aero-dynamic disturbance and electrical system such as VVVF inverter and SLIM still occur. In this study, the Maglev cabin noises are measured during running and zero speed conditions. Pass-by noise measurements are performed to obtain outside noise during the operation of the train on the test tract. Data include a single microphone measurement as well as microphone array measurements. The array data are useful for sound source localization and more detailed noise reduction planning.

  • PDF