• Title/Summary/Keyword: noise measuring method

Search Result 483, Processing Time 0.027 seconds

A New Image Processing-Based Fragment Detection Approach for Arena Fragmentation Test (Arena 시험을 위한 영상처리 기반 탄두 파편 검출 기법)

  • Lee, Hyukzae;Jung, Chanho;Park, Yongchan;Park, Woong;Son, Jihong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.599-606
    • /
    • 2019
  • The Arena Fragmentation Test(AFT) is one of the important tasks for designing a high-explosive warhead. In order to measure the statistics of a warhead in the test, fragments of a warhead that penetrate steel plates are detected by using complex and expensive measuring equipment. In this paper, instead of using specific hardware to measure the statistics of a warhead, we propose to use an image processing based object detection algorithm to detect fragments in AFT. To this end, we use a hard-thresholding method with a brightness feature and apply a morphology filter to remove noise components. We also propose a simple yet effective temporal filtering method to detect only the first penetrating fragments. We show that the performance of the proposed method is comparable to that of a hardware system under the same experimental conditions. Furthermore, the proposed method can produce better results in terms of finding exact positions of fragments.

Damage detection in steel structures using expanded rotational component of mode shapes via linking MATLAB and OpenSees

  • Toorang, Zahra;Bahar, Omid;Elahi, Fariborz Nateghi
    • Earthquakes and Structures
    • /
    • v.22 no.1
    • /
    • pp.1-13
    • /
    • 2022
  • When a building suffers damages under moderate to severe loading condition, its physical properties such as damping and stiffness parameters will change. There are different practical methods besides various numerical procedures that have successfully detected a range of these changes. Almost all the previous proposed methods used to work with translational components of mode shapes, probably because extracting these components is more common in vibrational tests. This study set out to investigate the influence of using both rotational and translational components of mode shapes, in detecting damages in 3-D steel structures elements. Three different sets of measured components of mode shapes are examined: translational, rotational, and also rotational/translational components in all joints. In order to validate our assumptions two different steel frames with three damage scenarios are considered. An iterative model updating program is developed in the MATLAB software that uses the OpenSees as its finite element analysis engine. Extensive analysis shows that employing rotational components results in more precise prediction of damage location and its intensity. Since measuring rotational components of mode shapes still is not very convenient, modal dynamic expansion technique is applied to generate rotational components from measured translational ones. The findings indicated that the developed model updating program is really efficient in damage detection even with generated data and considering noise effects. Moreover, methods which use rotational components of mode shapes can predict damage's location and its intensity more precisely than the ones which only work with translational data.

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

Design and Fabrication of an Electromagnetic Flowmeter (전자기유량계의 설계 및 제작)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.

3D Extraction Method Using a Low Cost Line Laser (라인레이저를 이용한 3D 모델 추출 방법)

  • Yun, Chun Ho;Kim, Tae Gi;Cho, Yong Wook;Nam, Gi Won;Yim, Choong Hyuk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.1
    • /
    • pp.108-113
    • /
    • 2017
  • In this paper, we proposed a three-dimensional(3D) scanning system based on laser vision technique for 3D model reconstruction. The proposed scanning system consists of line laser, camera, and turntable. We implemented the 3D scanning system using low quality elements. Although these are low quality elements, we reduced the 3D data reconstruction errors greatly using two methods. First, we developed a maximum brightness detection algorithm. This algorithm extracts the maximum brightness of the line laser to obtain the shape of the object. Second, we designed a new laser control device. This device helps to adjust the relative position of the turntable and line laser. These two methods greatly reduce the measuring noise. As a result, point cloud data can be obtained without complicated calculations.

A Control System Using Butterworth Filter for Loss-in-Weight Feeders (버터워스 필터를 이용한 감량식 정량연속공급장치 제어 시스템)

  • Kang, In-Jae;Moon, Sung-Min;Kwon, Joon Ho;Hong, Daehie
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.10
    • /
    • pp.905-911
    • /
    • 2014
  • A Loss-in-Weight (LIW) feeder, a type of automated measuring device, is a continuous feeder used in many mass production industries. Due to its versatility, there have been constant demands of LIW feeders in food production supply lines as well as chemical and pharmaceutical industries. In this paper, the process of designing a LIW feeder system with better performance will be examined and compared with commercial products. This system is characterized by low pass Butterworth filter and feed forward PI control. The filter is for noise disposal caused by dynamic condition of a LIW feeder. The feed forward PI control, based on linearity feature of feeders, is adequate for stable driving of the system. At the end, a possible evaluation method of LIW system will be proposed to verify the specific achievement of this paper.

A Study on Mean Flow Velocity Measurement by Cross Correlation of Ultrasonic Waves (초음파 상호상관 기법을 이용한 유체의 평균유속 측정 연구)

  • Kim, Chang-Ho;Lee, Dug-Ki;Paik, Jong-Seung;Jho, Moon-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.5-15
    • /
    • 1995
  • An application of the cross correlation technique by adopting ultrasonic waves for water pipe flow measuring purpose is studied. It is a non-intrusive flow metering method by determining the time of the flight of the flow turbulent noise and its non-obstructing mechanism enables to reduce process energy loss due to the flowmeter obstruction. A digital signal processor for the purpose of the real time Fourier transform was employed for the fast time calculation of the flow velocity. The overall accuracy was found as about $1\%$ for flow velocities from 0.25 m/s up to 16 m/s and for the pipe inside diameters from 50mm to 248mm. The cross correlation technique can be used for the tap water utility including most common liquid flows.

  • PDF

Structural Analysis of SLGT Platform

  • Kang, Gungwon;Ahn, Sang-Hyeon;Bae, Yeong-Bok;Kim, Chunglee;Kim, Whansun;Oh, John J.;Oh, Sang Hoon;Park, Chan;Son, Edwin J.;Jeong, Minjoong;Norton, Ronald S.;Paik, Ho Jung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.84.1-84.1
    • /
    • 2017
  • SLGT (Superconducting Low-frequency Gravitational-wave Telescope) platform has three arms whose ends support six superconducting test masses. Therefore, any motion of the platform could cause noises on measuring the displacements of test masses which contain the effect of gravitational waves passing by. Thermal motions of the platform are the main noise source, and are related to resonant motions of the platform structure. We briefly report preliminary results of nodal analysis in finite element method performed for various platform configurations including 2-m, 30-m, 50-m and 100-m arm lengths. Platform designs giving resonant frequencies outside of the signal bandwidth (e.g., 0.1~10 Hz) have been identified.

  • PDF

A study on the development of an electromagnetic flowmeter and the characterization of flow signal (전자기유량계의 개발및 신호 특성에 관한 연구)

  • Lim Ki Won;Kim Chang Ho
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.361-364
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The measuring tube of the EMF was basically designed as 100 m diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. To obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF For the characterization of EU, the uncertainty of calibrator was estimated within ${\pm}0.5{\%}$, the method of estimation was in accordance with the ISO 17025 recommendation. It was found that the flow signals between the electrodes were about ${\pm}60\;-\;{\pm}300{\mu}V$, which were sufficient for the discrimination of the flowmeter and protecting the noise. The test result against the calibrator, showed the good linearity in the range of $3 m^{3}/h\;and\;70m^{3}/h$. A commercialized design of the EMF will be technically more competitive in domestic and foreign market.

  • PDF

Autonomous Drone Path Planning for Environment Sensing

  • Kim, Beomsoo;Lee, Sooyong
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.209-215
    • /
    • 2018
  • Recent research in animal behavior has shown that gradient information plays an important role in finding food and home. It is also important in optimization of performance because it indicates how the inputs should be adjusted for maximization/minimization of a performance index. We introduce perturbation as an additional input to obtain gradient information. Unlike the typical approach of calculating the gradient from the derivative, the proposed processing is very robust to noise since it is performed as a summation. Experimental results prove the validity of the process of spatial gradient acquisition. Quantitative indices for measuring the effect of the amplitude and the frequency are developed based on linear regression analysis. Drones are very useful for environmental monitoring and an autonomous path planning is required for unstructured environment. Guiding the drone for finding the origin of the interested physical property is done by estimating the gradient of the sensed value and generating the drone trajectories in the direction which maximizes the sensed value. Simulation results show that the proposed method can be successfully applied to identify the source of the physical quantity of interest by utilizing it for path planning of an autonomous drone in 3D environment.