• Title/Summary/Keyword: noise measuring method

Search Result 482, Processing Time 0.028 seconds

A Comparative Study on Noise Characteristics for Measuring and Evaluating Method of Exterior Traffic Noise (외부교통소음 측정 및 평가방법에 따른 소음특성 비교 연구)

  • Yang, Jae-Hoon;Kim, Kyong-Woo;Choi, Hyun-Jung;Yang, Kwan-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.480-483
    • /
    • 2007
  • Recently, many apartment houses were built in nearby road and railway. Road traffic noise level and railroad traffic noise level are important factors on apartment houses inhabitant's acoustic comforts. The measurement methods which noted by Ministry of Construction & Transportation, Ministry of Environment and Korean Industrial Standard are used for measurement of exterior noise at apartment houses. The purpose of this study compare the noise level characteristic by the measuring methods and evaluating methods. The results show that road traffic noise in the daytime appeared by not greatly noise level difference by the measuring method and evaluating methods. But railroad traffic noise appeared by greatly the noise level difference by the equivalent noise level(1hour) and continuous time.

  • PDF

A Noise Prediction Method on the Movement Measuring Points at Measurement for Aircraft Noise (항공기 소음 측정 시 이동측정지점에 대한 소음도 예측방법)

  • Woo, Jeong Ha;Lee, Byung Chan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.12
    • /
    • pp.901-906
    • /
    • 2015
  • It is difficult to measure aircraft noise at many points, because the noise measurement is need to long time, 24 hours and consecutive 7 days, which results in high costs. As an alternative, movement measuring points are set to measure aircraft noise for less than 24 hours, and so it is needed to overcome the limitation of shorter measuring time. Thus, this study measured military aircraft noise on movement measuring points and conducted a comparative analysis on the data according to each measuring time. The data of measuring noise for 24 hours and less than 24 hours were compared to suggest appropriate measuring time on the movement measuring points. As a result of comparing data of measuring noise, an error was within 3 dB in case of measuring time of 3 hours, and an error was within 1 dB in case of 6 hours of measurement.

Effect of the Stiffness on the Performance of Impact Noise Isolation Pads of a Floor (바닥충격음 방지재의 재료강성 효과)

  • Lee, Dong-Hoon;Hwang, Yoon;Kang, Moon;Kim, Min-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.425-430
    • /
    • 2000
  • This paper describes the effect of the pad stiffness on the noise reduction of impact noise isolation pads of a floor. And also a new semi-experimental method for measuring the impact noise isolation capability of a pad is introduced. The impact noise isolation pads made of wire-mesh, urethane-chip and foam rubber are used for measuring the stiffness, the vibrational insulation performance and the impact noise isolation capability. The correlation between the stiffness and impact noise isolation capability of pads is theoretically reviewed, and confirmed from the experimental results. For measuring the impact noise isolation capability of only an isolation pad, a semi-experimental method proposed in this study is more effective than the reverberation room method.

  • PDF

Development and Application of Measuring Method for Instantaneous Intensity (순시 인텐시티 측정 기법의 개발 및 응용)

  • 이장우;안병하
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.960-963
    • /
    • 2003
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these state, select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

Measurement and Control of Abnormal Sound for Refrigerator (냉장고의 이상소음에 관한 사례연구)

  • 주재만;김중래;이동현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.380-384
    • /
    • 2001
  • The household reftigerator's noise which is closely related with resident environment can hardly be evaluated its sound quality using the Korean Standards. Radiation characteristics of compressor noise consist of tonal noise in low frequency range and, or narrow band noise in high frequency range. In this study, measuring method for detecting the abnormal and low-level noise in high frequency band is presented, and control method for its reduction is proposed. After installing wall which is similar to living condition, we determined a major concerning frequency band of noise. It can be found the directivity of high frequency noise radiated from compressor by using experiment and analysis. According to isolation of noise transfer path, remarkable noise reduction is achieved.

  • PDF

Application of the Partial Discharge Measuring Method in Operating Transformer (운전중인 변압기의 부분방전 측정기법 적용)

  • 권동진;최인혁;정길조
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.94-98
    • /
    • 2000
  • This paper describes an application of the partial discharge measuring method in operating transformer. In the operating transformer, the useful PD signal may be superimposed by radio intereference voltage and impulse shaped noise signals generated by external corona or power electronics. In this paper, initial investigations after connecting the PD measuring system to the terminals of the measuring impedance showed a very high noise level of 3,700pC due to sinusoidal interferences. In order to reject these noises, this paper applied RIV and band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,700pC to 160pC.

  • PDF

A compare study on the Evaluation Method of Aircraft Noise (항공기 소음의 평가 척도에 대한 비교 연구)

  • 전지현;안병옥;송민정;장길수;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.703-706
    • /
    • 2001
  • Currently domestic criteria for the aircraft noise is being adapted WECPNL(weighted equivalent continuous perceived noise level), while internationally preferred method is which is originated from $L_{eq}$ and can evaluate even environmental noise. WECPNL used in domestic as a evaluation method is only for the aircraft noise. It is, therefore, not adequate for the evaluation of residents' injury, moreover, it is very difficult to measure the aircraft noise with WECPNL due to the complicated calculating procedures as long as automatic measuring system is not used. Accordingly, this study aims to propose alternative evaluation method for the aircraft noise. To achieve this purpose, the data measured by automatic measuring system were gathered and calculated with three evaluation methods: WECPNL, $L_{eq}$ and $L_{dn}$ and the results calculated from different methods were compared and analyzed.

  • PDF

A Study of Eliminating the Vehicle Noise of Engine RPM from the Friction Noise between Tire and Road Pavement by Using a NCPX Method (NCPX 계측방법을 이용한 타이어/노면 사이에서 발생하는 마찰소음에 대한 차량자체에서 발생하는 소음 제거 연구)

  • Han, Bong-Koo;Kim, Do Wan;Mun, Sungho;Kim, Ha-Yeon
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.31-42
    • /
    • 2013
  • PURPOSES : The purpose of this study is to eliminate the noise of the vehicle after measuring the friction noise obtained from the NCPX (Noble Close ProXimity) method. The pure friction noise between the tire and road pavement could be determined from filtering the compositeness of sound and the influence of the vehicle noise. METHODS: The noise magnitude could be determined by analyzing the sound pressure level (SPL) and sound power level (PWL) along with the noise frequency of a FFT (Fast Fourier Transform) analysis as well as CPB (Constant Percentage Bandwidth) analysis. RESULTS: When the test for measuring the friction noise originated somewhere between tire and road pavement is performed with NCPX method, it must be fulfilled by attaching the surface microphone near the tire. In this condition, the surface microphone can measure the friction noise occurred at between tire and pavement, the chassis noise from the engine and power transfer units, the fluctuating aerodynamic noise, and the turbulence noise directly affected to the surface microphone. By using the NCPX method, the noise occurred at the vehicle must be eliminated for measuring the friction noise between tire and pavement from the traffic noise. CONCLUSIONS: The vehicle's testing engine noise depends on the vehicle and road types. The effect of vehicle's engine noise is less than the friction noise occurred at between tire and pavement at less than 1% effect.

Development and Application of Measuring Method of Instantaneous Intensity (순시 인텐시티 측정 기법의 개발 및 응용)

  • 이장우;김영종;안병하;이운섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.560-563
    • /
    • 1997
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these states select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

Field Measurements on Drain Noise in Bathroom of Apartment House (공동주택 욕실 배수소음의 현장 측정방법)

  • Yang, K.C.;Lee, T.G.;Kim, S.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.345-348
    • /
    • 2005
  • The method of measurement for field tests on noise emission from water closet in bathroom of apartment house. This part of standard gives detailed descriptions for field tests on noise emission from water closet in bathroom. The measuring position have to investigated measuring for emission noise.

  • PDF