• Title/Summary/Keyword: noise exposure

Search Result 517, Processing Time 0.021 seconds

A Study on the Physical Environment of Middle School Classrooms in Winter -Focusing on the Classrooms in Cheju City- (겨울철 중학교교실의 물리적 학습환경실태에 관한 연구 -제주시를 중심으로-)

  • 오인순
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.3
    • /
    • pp.193-204
    • /
    • 1997
  • The purpose of this study is to measure some physical environmental factors and to doucument students' perceptions of them. 11 middle schools in Cheju City were divided into four areas according to their locations and two schools were selected for the study. 144 thirteen-year-old students in two middle school in a overcrowded area in Cheju City-one middle school building is insulated and the other is not insulated-were taken for the questionnaire survey. The finding of the study are as follows: 1) The classrooms were not equipped with any heating equipment. The buildings are not insulated well. As a result, the room temperature was much lower(12.9-16.2℃) than comfortable indoor temperature in winter(21.5-24.5℃). The classroom were found to be colder(12.9-16.2℃) than usual pleasant indoor temperature(21.5-24.5℃) in winter. 2) The classroom were so far from the street(20m) that there was little noise from traffic. Nevertheless, the noise level was higher(62.5-66.2 dB(A), when the windows were open; 51.7-62.8dB(A), when closed than the noise tolerance level specified in the Environment Protection Laws(50.0dB(A)). 3) As for the visual environment, the location of classroom, the adequate sun exposure, and the total states of windows in classrooms influenced on the illuminance. While standard indoor illuminance is 300 Lux, the classrooms facing south had illuminance of 231 Lux, from day light: and the ones facing west, 380 Lux. 4) Students generally found other aspects of the physical environment of their classrooms unsatisfactory. Chalk dust was generated to a serious extent near the main chalkboard(0.25mg/㎥) of classrooms.

  • PDF

A Study on Various Automatic Exposure Control System in Multi-Detector Computed Tomography by Using Human Phantom (인체 모형을 이용한 다중 검출기 컴퓨터단층촬영기기의 다양한 자동노출제어 시스템에 대한 연구)

  • Kim, Yong-Ok;Seoung, Youl-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1714-1720
    • /
    • 2012
  • The purpose of the study was to evaluation of the radiation dose reduction and the possibility of the maintainability of the adequate image quality using various automatic exposure control (AEC) systems in multi-detector computed tomography (MDCT). We used three AEC systems for the study: General Electric Healthcare (Auto-mA 3D), Philips Medical systems (DoseRight) and Siemens Medical Solutions (Care Dose 4D). The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using human phantom. The image quality of the phantom was evaluated with measuring the image noise (standard deviation) by insert regions of interests. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the Auto-mA 3D, 58.2% in the DoseRight, and 48.6% in the Care Dose 4D. And, there was not statistical significant difference among the image quality in the Strong/Weak of the Care Dose 4D(P=.269). This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

Comprehensive Analysis of Exposed Adverse Factors in Disaster Response Activities - Focused on Fire - (재난 대응 활동 시 노출가능 유해인자 종합분석 -화재 현장을 중심으로-)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.420-430
    • /
    • 2014
  • Firefighters performing disaster response activities such as Fire Suppression Rescue First Aid in fire are being exposed in various adverse factors, heat, smoke, toxic gases, emotional stress, biological toxic factors and physical overload by unnatural ergonomic posture required for firefighters. But so far, there is the study for this problem only separately. There is no study about comprehesive analysis of exposed adverse factors in fire-related disaster response activities and countermeasures. The purpose of this study is to contiribute to solving the health problems and prevention of accidents of firefighters by extracting hazardous agents in disaster such as fire and by proposing countermeasures. After analyzing circumstances such as fire-suppression, rescue first aid and life-environment, exposure factors of fire are derived and exposure status is suggested according to physical chemical biological psychological aspects. The countermeasure against the noise of the physical exposure factors are proposed. The countermeasures such as protective equipment and clean room in chemical factors, infection prevention education, vaccination and periodic check system in biological factors, PTSD alleviation booth and mentoring in psychological factors are proposed.

Trace level analysis of Pb in plasma by inductively coupled plasma/mass spectrometry (유도결합플라즈마 질량분석법을 이용한 혈장 중 극미량 납 분석)

  • Lee, Sung-Bae;Yang, Jeong-Sun;Choi, Sung-Bong;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.190-196
    • /
    • 2012
  • The human exposure of lead has usually detected the amount of lead in the whole blood, however, this method has a shortcoming to give the information on the short-term exposure to lead. In that sense, it is desirable to estimates the level of lead in plasma to draw the chronic bio-marker of lead exposure even though it is difficult to measure lead of several ng/L. An inductively coupled plasma-mass spectrometry (ICP-MS) method was developed for determining lead in plasma as the chronic bio-marker of lead of workers. To minimize the contamination of lead from the environment, we constructed class 1,000 clean room and compared the amount of floating dust before and after the operation of the clean room. The limit of detection (LOD) and the limit of quantification (LOQ) of lead in fetal bovine serum were 4.3 ng/L and 12.2 ng/L by NIOSH method (statistical calculation method) and 7.0 ng/L and 22.1 ng/L by signal/noise ratio, respectively. The accuracy was in a range of 92.3-101.3%, and the precision of the assay was less than 4% in the samples spiked in the concentration of 20 ng/L and 2,000 ng/L. The method was simple, reproducible and sensitive enough to permit reliable analysis of lead to the ng/L level in plasma and/or serum. The method was also useful for the biological monitoring of chronic exposure to lead.

Ride Quality Assessment of Automative Seats by Simultaneous 3-Axis Excitation (동시 3축 가진에 의한 자동차 의자류의 승차감 평가)

  • 정완섭;우춘규;박세진;김수현
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.143-152
    • /
    • 1997
  • This paper introduces experimental results of the ride qulaity characteristics of automotive seats fixed on the vibration table that is noving simultaneously to the three-axis in a similar way to the real running condition. Vibration experiment was carried out for five different automotive seats and four Korean individuals. The assessment of the ride quality characteristics for each seat and indiviual was made not only from the analysis of vibration measurements but also from the evaluation of weighied vibration signals, which were obtained using the frequency weighting function and the multiplication factor dependent on the position and axis of vibration exposure to wehole-body. The usefulness of those assessment results in analysis of the ride quality of seats is discussed and their limitation is also pointed out in this paper.

  • PDF

POSSIBLE DERIVATIONS OF ORTHO- AND PARA-$H_2$ RATIOS IN THE ATMOSPHERES OF THE GIANT PLANETS USING THE $2\mu m$ SPECTRAL STRUCTURES OF $(H_2)_2$

  • Kim, Sang-Joon;Lee, Yong-Sik
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.2
    • /
    • pp.95-100
    • /
    • 2001
  • We have presented an ab initio model of the $2{mu}m$ spectral features of $(H_2)_2$ based on the far-infrared models of McKellar & Schaefer (1991). We have shown that the intensity variations of the $2{mu}m;(H_2)_2$ features depend on the ortho/para ratios of $H_2$ We have discussed the applicability of the variations to the atmospheres of the giant planets for the derivations of the ortho/para ratios. The signal to noise ratios of currently available spectra of the giant planets are not sufficient enough to derive accurate ortho/para ratios of these planets. Observations with longer exposure times and larger telescope apertures are required to obtain better spectra for the derivations of the ortho/para ratios of $H_2$ in the atmospheres of the giant planets.

  • PDF

Real-Time Digital Image Stabilization for Cell Phone Cameras in Low-Light Environments without Frame Memory

  • Luo, Lin-Bo;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.34 no.1
    • /
    • pp.138-141
    • /
    • 2012
  • This letter proposes a real-time digital image stabilization system for cell phone cameras without the need for frame memory. The system post-processes an image captured with a safe shutter speed using an adaptive denoising filter and a global color correction algorithm. This system can transfer the normal brightness of an image previewed under long exposure to the captured image making it bright and crisp with low noise. It is even possible to take photos in low-light conditions. By not needing frame memory, the approach is feasible for integration into the size-constrained image sensors of cell phone cameras.

Fabrication of $0.25 \mu\textrm{m}$ P-HEMT for X-band Low Noise Amplifier (X-밴드 저잡음 증폭기용 $0.25 \mu\textrm{m}$ T-형 게이트 P-HEMT 제작)

  • 이강승;정윤하
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.17-20
    • /
    • 2000
  • We have enhanced the yield of 0.25 ${\mu}{\textrm}{m}$ T-gate $Al_{0.25}$G $a_{0.75}$As/I $n_{0.2}$G $a_{0.8}$As P-HEMT using three-layer E-beam lithography process and selective etching process. The three-layer resist structure (PMMA/copolymer/ PMMA=2000 $\AA$/3000 $\AA$/2000 $\AA$) and three developers (Benzene:IPA=1:1,Methanol:IPA =1:1,MIBK:IPA=1:3) were used for fabrication of a wide-head T-gate by the conventional double E-beam exposure technology. Also 1 wt% citric acid: $H_2O$$_2$:N $H_{4}$OH(200m1:4ml:2.2ml) solution were used for uniform gate recess. The etching selectivity of GaAs over $Al_{0.25}$G $a_{0.75}$As is measured to be 80. So these P-HEMT processes can be used in X-band MMIC LNA fabrication.ion.ion.ion.

  • PDF

HIGH RESOLUTION NEAR-INFRARED SPECTRA OF NEARBY QUASAR, PG1426+015

  • Le, Huynh Anh Nguyen;Pak, Soo-Jong;Im, Myung-Shin;Ho, Luis C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.51.1-51.1
    • /
    • 2012
  • We observed low-z quasar PG1426+015 (z=0.086), using the near-IR high resolution echelle spectrometer, IRCS, at the SUBARU 8.2 m telescope. Using an Adoptive Optics system, the full width at half maximum of the point spread function was about 0.3 arcsec, which can effectively separate the quasar spectra from the host galaxy spectra. We also maximize the total exposure time up to several hours per target, and develop data reduction methods to increase the signal-to-noise ratios. This poster presents the data reduction processes and sample spectra from the quasar and its host galaxy. These spectral lines will be used to study the physical mechanism of quasars, and the velocity dispersions of the stars in the bugle of the host galaxy.

  • PDF

Recent Development in Low Dose Nuclear Medicine Gamma Camera Imaging (저선량 핵의학 감마카메라 영상장치의 최근 발전)

  • Hwang, Kyung Hoon;Lee, Byeong-il;Kim, Yongkwon;Lee, Haejun;Sun, Yong Han
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.123-127
    • /
    • 2015
  • Recently, new gamma camera systems enabling low radiation dose imaging have been developed. We reviewed the recent development of these low dose gamma camera systems including high sensitivity detectors, device structures, noise reduction filters, efficient image reconstruction algorithms, low dose protocols, and so on. It is expected that further technological advances reduce both radiation dose and imaging time in gamma camera imaging especially for radiation-sensitive patients such as pediatric patients.