• 제목/요약/키워드: noise exposure

검색결과 514건 처리시간 0.027초

소방 공무원의 시간활동 양상과 직무에 따른 소음 노출 특성 (Noise Exposure according to the Time Activity Pattern and Duties of Firefighters)

  • 이임규;강태선;함승헌;김정인;양영숙;윤충식
    • 한국환경보건학회지
    • /
    • 제37권2호
    • /
    • pp.94-101
    • /
    • 2011
  • Objectives: The purpose of this study is to evaluate the noise exposures of firefighters according to their time-dependent activity patterns. Methods: Personal exposure levels were measured for six days and nights using noise dosimeters; three days and nights for on-duty tasks, the other days and nights for off-duty activities. Results: The total amount of time spent in the workplace was 13,677 min (67%), outside areas 4,833 min (23%), in transit 1,002 min (5%), and other indoor area 807 min (4%) during a working period. However, during off-days they spent 10,858 min (76%) at home, 1,382 min (10%) outdoors, 1,225 min (9%) other indoors, and 493 min (3%) in transit. As a result of individual exposure levels, TWA did not exceed 90 dBA of the occupational exposure limit for the majority of the firefighters, whereas the levels of Lmax were 119 dBA, which were higher than the noise levels of firefighters in USA. Sometimes during dispatching the levels of Lpeak exceeded the ACGIH exposure standard (140 dBC). The Leq levels in transit were higher than the levels in home and other indoors even though the activity time is short. Conclusions: This paper characterized the noise exposure patterns of firefighters in Korea. We suggest that special noise sources, including sirens and speaker phones, should be readjusted to reduce noise exposure.

Noise Exposure Assessment in a Dental School

  • Choosong, Thitiworn;Kaimook, Wandee;Tantisarasart, Ratchada;Sooksamear, Puwanai;Chayaphum, Satith;Kongkamol, Chanon;Srisintorn, Wisarut;Phakthongsuk, Pitchaya
    • Safety and Health at Work
    • /
    • 제2권4호
    • /
    • pp.348-354
    • /
    • 2011
  • Objectives: This cross-sectional study was performed in the Dental School of Prince of Songkla University to ascertain noise exposure of dentists, dental assistants, and laboratory technicians. A noise spectral analysis was taken to illustrate the spectra of dental devices. Methods: A noise evaluation was performed to measure the noise level at dental clinics and one dental laboratory from May to December 2010. Noise spectral data of dental devices were taken during dental practices at the dental services clinic and at the dental laboratory. A noise dosimeter was set following the Occupational Safety and Health Administration criteria and then attached to the subjects' collar to record personal noise dose exposure during working periods. Results: The peaks of the noise spectrum of dental instruments were at 1,000, 4,000, and 8,000 Hz which depended on the type of instrument. The differences in working areas and job positions had an influence on the level of noise exposure (p < 0.01). Noise measurement in the personal hearing zone found that the laboratory technicians were exposed to the highest impulsive noise levels (137.1 dBC). The dentists and dental assistants who worked at a pedodontic clinic had the highest percent noise dose (4.60 ${\pm}$ 3.59%). In the working areas, the 8-hour time-weighted average of noise levels ranged between 49.7-58.1 dBA while the noisiest working area was the dental laboratory. Conclusion: Dental personnel are exposed to noise intensities lower than occupational exposure limits. Therefore, these dental personnel may not experience a noise-induced hearing loss.

소음측정방법에 따른 평가소음도 비교 (A Comparison of Noise Level by Noise Measuring Methods)

  • 심철구;노재훈;박정균
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.128-136
    • /
    • 1995
  • The purpose of this study is to evaluate the difference of noise level according to noise measuring methods in the noisy working environments. Sound pressure level(SPL), equivalence sound level(Leq) and personal noise exposure dose(Dose) in the fifty-nine unit workplaces of the twenty-eight industries were measured and relating factors which were affected noise level were investigated. The results were as follows ; 1. The noise levels were $88.70{\pm}5.68dB(A)$ by SPL, $89.07{\pm}5.41dB(A)$ by Leq and $89.07{\pm}5.69$ by Dose. The differences of noise levels by three measuring methods were statistically significant(P<0.001) by repeated measure ANOV A. 2. Comparing with noise levels by general classes of noise exposure, noise levels of continuous noise were $89.14{\pm}5.19dB(A)$ by SPL, $89.45{\pm}4.65dB(A)$ by Leq and $90.04{\pm}5.09$ by Dose. Noise levels of intermittent noise were $87.90{\pm}6.52dB(A)$ by SPL, $88.40{\pm}6.63dB(A)$ by Leq and $90.10{\pm}6.80$ by Dose. The differences noise level of noise measuring methods by general classese of noise exposure were statistically not significant by repeated measure ANOV A. 3. Interaction between general classese of noise exposure and noise measuring methods for noise level was not statistically significant by repeated measure ANOVA. And the noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001) 4. Comparing with noise levels by unit workplace size, noise levels of large unit workplace were $90.73{\pm}5.87dB(A)$ by SPL, $91.32{\pm}5.50dB(A)$ by Leq and $91.82{\pm}6.06$ by Dose and noise levels of middle unit workplace were $88.31{\pm}5.26dB(A)$ by SPL, $88.41{\pm}4.83dB(A)$ by Leq and $89.69{\pm}5.05$ by Dose. And noise levels of small unit workplace were $94.89{\pm}4.10dB(A)$ by SPL, $85.35{\pm}4.11dB(A)$ by Leq and $86.87{\pm}4.98$ by Dose. The noise level differences of noise measuring methods by unit workplace size were statistically significant by repeated measure ANOV A(P<.05). 5. The noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001). But Interaction between workplace size and noise level measuring methods for noise level was not statistically significant by repeated measure ANOVA. According to the above results, there was a difference of the noise level among the three measuring methods. Therefore we must use the personal noise exposure dose using by noise dose meter, possible, to prvent occupational hearing loss in noisy working environment.

  • PDF

목재판넬 제조공정의 환경위험성평가 (Environmental Hazardous Assessment on Wood Panel Manufacturing Process)

  • 이수길;이내우
    • 한국안전학회지
    • /
    • 제22권3호
    • /
    • pp.13-21
    • /
    • 2007
  • Personal and static sampling for formaldehyde, wood dust and noise monitoring, in accordance to the equipment running on the day, were carried out throughout wood panel manufacturing process. Even though the exposure level of formaldehyde and wood dust were below than exposure criteria, but the personal protective equipment(PPE) for those should be worn to everyone in the process because of its potential characteristics like carcinogenicity. Also a few local air extraction system above the cutting, grinding sections and organic blending room should be required. Most of the exposures of noise exposure were exceeded permitted exposure criteria, in case of Hopper operators, exposed to maximally 94dB(A) as LAeq 8hr, therefore active controls like PPE, monitoring, isolation etc. are necessary. The main sources of noise were caused on compressed air of the machinery, radio sound and operation noise like running machines, conveying, cutting, sawing, moving vehicles, storing and so on. For the comparison of control criteria in each country, the permitted exposure standards for above hazardous materials and noise in Korea, ACGIH and Australia were discussed. We have recognized that the Korean criteria should be discussed urgently to give the right information to employee and modified, if it is necessary.

만성적 소음노출과 혈압의 상관성에 관한 메타분석 (A Meta-analysis on the Association between Chronic Noise Exposure and Blood Pressure)

  • 김춘배;김재용;차봉석;최홍렬;이종태;남정모;이상윤;왕승준;박기호;김대열;고상백
    • Journal of Preventive Medicine and Public Health
    • /
    • 제33권3호
    • /
    • pp.343-348
    • /
    • 2000
  • Objectives : This study was conducted to integrate the results of studies assessing the association between chronic noise exposure and blood pressure. Methods : Using a MEDLINE search with noise exposure, blood pressure and hypertension as key words, we retrieved articles from the literature that were published from 1980 to December 1999. The criteria for quality evaluation were as follows: 1) the study subjects must have been workers employed at a high noise level area 2) The paper should use average and cumulative noise exposure as method for exposure evaluation. 3) Blood pressure in each article should be reported in a continuous scale Among the 77 retrieved articles, six studies were selected for quantitative meta-analysis. Before the integration of the regression coefficients for the association between blood pressure and noise level, homogeneity tests were conducted. Results : All studies were a cross-sectional design and the study subjects were industrial workers. Five papers used a time-weighted average for noise exposure and only one paper calculated the cumulative noise exposure level. The measurement of blood pressure in the majority of studios were accomplished in a resting stale, and used an average of two or more readings. The homogeneity of studies was rejected in a fixed effect model, so we used the results in a random effect model. The results of the quantitative meta-analysis, the weighted regression coefficient of noise associated with systolic blood pressure and diastolic blood pressure were 0.05 (95% confidence interval [CI]: -0.03, 0.13) and 0.06 (95% CI: -0.01, 0.13), respectively. Conclusions : Our results suggested that chronic exposure to industrial noise does not cause elevated blood pressure.

  • PDF

Dual Exposure Fusion with Entropy-based Residual Filtering

  • Heo, Yong Seok;Lee, Soochahn;Jung, Ho Yub
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권5호
    • /
    • pp.2555-2575
    • /
    • 2017
  • This paper presents a dual exposure fusion method for image enhancement. Images taken with a short exposure time usually contain a sharp structure, but they are dark and are prone to be contaminated by noise. In contrast, long-exposure images are bright and noise-free, but usually suffer from blurring artifacts. Thus, we fuse the dual exposures to generate an enhanced image that is well-exposed, noise-free, and blur-free. To this end, we present a new scale-space patch-match method to find correspondences between the short and long exposures so that proper color components can be combined within a proposed dual non-local (DNL) means framework. We also present a residual filtering method that eliminates the structure component in the estimated noise image in order to obtain a sharper and further enhanced image. To this end, the entropy is utilized to determine the proper size of the filtering window. Experimental results show that our method generates ghost-free, noise-free, and blur-free enhanced images from the short and long exposure pairs for various dynamic scenes.

ETTR 노출 방법을 활용한 디지털 카메라의 화질 향상 (Development of Image Quality Enhancement of a Digital Camera with the Application of Exposure To The Right Exposure Method)

  • 박형주;하동환
    • 한국콘텐츠학회논문지
    • /
    • 제10권8호
    • /
    • pp.95-103
    • /
    • 2010
  • 디지털 카메라의 센서는 각각의 픽셀에 대응하는 휘도 값을 저장한 것이다. 이러한 상태의 기록을 로파일이라고 한다. 로파일은 가장 밝은 하이라이트 한 스톱부터 이미지가 갖는 레벨 값의 절반을 할당하고 그 나머지의 절반을 그 다음 스톱에 할당하는 방식으로 가장 어두운 섀도에는 가장 적은 레벨을 분배하는 특성을 갖는다. 그러므로 가장 많은 레벨 정보를 갖고 있는 가장 밝은 하이라이트 한 스톱을 촬영 시 반드시 확보하면 디지털 카메라의 향상된 화질을 구현할 수 있을 것이다. 즉 이러한 디지털 이미지의 정보 기록 분배 방식으로 인하여 촬영 시 노출이 매우 중요하다고 판단할 수 있다. 본 논문은 디지털 카메라의 최적노출을 위하여 가장 많은 레벨 값이 할당되는 하이라이트 한 스톱을 가능한 한 최대한도로 유지하기 위하여 얼마만큼의 노출 과다 조정과 감도가 효과적인지 실험을 통하여 밝혀냈다. 이를 위하여 디지털 카메라를 적정 노출에서부터 1/3스톱씩 2스톱까지 7단계의 노출 과다로 촬영하고 적정 노출을 기준으로 노출이 과다된 로파일을 노출 부족으로 컨버팅 하여 화질을 향상시키는 ETTR(Exposure to the right) 노출 방법의 효용성을 검증하였다. 그 결과 다이내믹 레인지를 확장시키고 비주얼 노이즈를 최소화시키는 디지털 카메라의 최적 화질 구현을 위하여 가장 적정한 노출은 약 $1\frac{2}{3}$ 스톱 정도 노출을 과다하였을 때이며 고감도로 갈수록 그 효과가 높았다. 이와 같은 논문은 카메라 사용자와 제조사에게 실용적인 ETTR 노출 정보를 제공함으로써 넓은 다이내믹 레인지를 구현하는 동시에 노이즈를 최소화시켜 최적화된 디지털 카메라의 화질 구현할 수 있게 할 것이다.

군용항공기 소음평가 단위에 관한 연구 (A Study on the Evaluation Unit of a Military Aircraft Noise)

  • 이준호
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.550-557
    • /
    • 2005
  • Korean 'Law of Aviation' and 'Test Method of Measuring Noise and Vibration' designate to use WECPNL metric based on $L_{max}$ measurement for the accessment of aircraft noise in Korea. However, time duration of noise event can not be considered in $L_{max}$ metric in principle, compensation on the duration has been utilized. A study was done recently to evaluate appropriate duration compensation for the accessment of military aircraft noise under current metric of WECPNL and $L_{max}$. This study was carried out to evaluate what metric is the most appropriate to express aircraft noise including time duration of single noise event, computing and comparing noise exposure with 1 second noise measurement data of military aircraft in $L_{max}$, $L_{Aeq,\;T}$ and SEL. This study shows SEL is the most appropriate noise metric for the evaluation of noise exposure with time duration such as aircraft noise without compensation. It is suggested to use SEL noise metric instead of $L_{max}$ noise metric with duration compensation for the aircraft noise accessment either military aircraft or civilian aircraft.

모 자동차 공장의 소음폭로와 혈압에 관한 연구 (A Study on Noise Exposure Dose and Blood Pressure in an Automobile)

  • 김성천
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.48-53
    • /
    • 1991
  • This study was carried out to investigate age, noise intensity, work period, hearing loss at frequencies, hypertension and to examine correlation of the total quantity of noise exposure(Dose) and blood pressure (Response) in the auto industry during May 1987-December 1987. To perform this study 65 workers were tested. Results of this study were as follows: 1. In frequency analysis, the CS-dip phenomenon occurred around 4000 Hz. 2. Between under of ten years group and over of ten years group, average hearing loss value was statitically significant (P < 0.05). 3. The prevalence of hypertension of 65 workers was 7.84% . 4. At 90dB(A) over and 10 years under and workers in the 20's group, the total quantity of noise exposure (Dose) and systolic blood pressure (Response) were statistically significant (P < 0.05). 5. At under 10 years of work period group, the total quantity of noise exposure(Dose) and diastolic blood pressure (Response) were statistically significant(r =0.234, P < 0.1).

  • PDF

Assessment of Noise Exposure and Hearing Loss Among Workers in Textile Mill (Thamine), Myanmar: A Cross-Sectional Study

  • Zaw, Aung K.;Myat, Aung M.;Thandar, Mya;Htun, Ye M.;Aung, Than H.;Tun, Kyaw M.;Han, Zaw M.
    • Safety and Health at Work
    • /
    • 제11권2호
    • /
    • pp.199-206
    • /
    • 2020
  • Background: In a wide range of industries, noise-induced hearing loss remains one of the most prevalent occupational problems. This study aimed to assess the noise exposure level and associated factors of hearing loss among textile workers in Yangon Region, Myanmar. Methods: A cross-sectional study was conducted at a Textile mill (Thamine), Yangon Region, from April to December 2018. In total, 226 workers who were randomly selected from 3 weaving sections participated in face-to-face interviews using a structured questionnaire. A digital sound level meter and pure-tone audiometer were used for the assessment of noise exposure level and hearing loss, respectively. Logistic regression analysis was performed to assess the associated factors of hearing loss. Results: In total workers, 66.4% were exposed to ≥85 dB(A) of noise exposure, and the prevalence of hearing loss was 25.7%. Age ≥35 years, below high school education, hearing difficulty, tinnitus, hypertension, > 9 years of service duration in a textile mill were positively associated with hearing loss. After adjusting confounding factors, age ≥35 years (adjusted odds ratio = 6.90, 95% confidence interval = 3.45-13.82) and tinnitus (adjusted odds ratio = 2.88, 95% confidence interval = 1.13-7.37) were persistently associated with hearing loss. Conclusion: Providing occupational hazard education and enforcement of occupational safety regulations should be taken to decrease the noise exposure level. The regular audiometry test should be conducted for assessment of hearing threshold shift. The employer needs to implement a hearing conservation program in workplace when noise exposure reaches or exceeds 85 dB(A) for 8 hours.