• Title/Summary/Keyword: noise exposure

Search Result 517, Processing Time 0.031 seconds

Changes of Electrical Properties of Graphene upon Introduction of Structural Defects and Gas Exposure

  • Kim, Kang-Hyun;Kang, Hae-Yong;Lee, Jae-Woo;Lee, Nam-Hee;Woo, Byung-Chill;Yun, Wan-Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.474-474
    • /
    • 2011
  • Graphene is considered as a potential candidate for the key material in the ideal 2D nanoelectronics. Recently, it is reported that graphene has an interesting sensitivity to molecular adsorption on it. Such properties are believed to be enhanced by the existence of disorders and ripples inside graphene as well as by the interaction with the substrate underneath. Here, we report the effect of introducing structural disorders to the graphene on its electrical properties such as conductance, transconductance, low frequency noise, which can be successfully described by a simple model of the continuum percolation. In addition, the response of the graphene device to gaseous molecular adsorption was systematically investigated and the results were discussed along with the change in Raman spectra.

  • PDF

Electric power characteristic test of diagnostic X-ray high voltage transformer by input power condition (고전압트랜스포머의 진공이 방사선출력 노이즈에 미치는 영향)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Young-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.499-499
    • /
    • 2008
  • High voltage transformer of Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. High voltage transformer of diagnostic X-ray system has been usefully used for diagnostic purpose but if high voltage transformer performances are deteriorated, low quality image will be archived. In this case, operator has to exposure to get a more good quality images. In this case, unexpected radiation could be exposed to patient and it is very harmful to the patient. And I would like to design and make equipment to checkable high voltage transformer performance after that I wish to test and study what it is most influences in radiation output quality.

  • PDF

Adaptive Over-Exposure Method for Improving Signal-to-Noise Ratio on Digital Cameras (디지털 카메라에서 신호대 잡음비(SNR)를 높이기 위한 적응형 과다 노출 방법)

  • Lee Wonjae;Kim Hak-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.829-831
    • /
    • 2005
  • 디지털 카메라 이미지의 화질을 저하시키는 주요 요인 중 하나는 노이즈이다. 디지털 카메라에 사용되는 CCD/CMOS 센서의 특성상, 노출이 증가할수록 신호대 잡음비(SNR)가 증가한다. 따라서 디지털 카메라에서 SNR이 높은 이미지를 얻기 위해서는 되도록 많은 노출을 주어야 한다. 하지만 너무 과다한 노출을 주게 되면 highlight clipping이 일어나기 때문에, RGB 모든 채널에서 clipping이 일어나지 않는 범위 안에서 노출을 주어야 한다. 그리고 CCD/CMOS RAW 데이터에 대해 카메라의 이미지 프로세싱 과정에서 디지털 노출 보정을 해주면 사람이 보기에 적절한 노출을 가지면서도 SNR이 높은 고화질의 이미지를 얻을 수 있다.

  • PDF

Comparison and Analysis of Standardised Methods for Predicting the Hazards of Whole-body Vibration and Repeated Shocks (전신 피폭 진동 및 반복 충격에 의한 위함 예측 표준 방안들의 비교 분석)

  • ;;Michael J. Griffin
    • Journal of KSNVE
    • /
    • v.10 no.1
    • /
    • pp.160-167
    • /
    • 2000
  • This paper addresses issues encountered in using the ISO and national standard codes to assess the hazards of whole-body vibration and repeat shocks. Their assessment methods are given in ISO 2631-1 (1974, 1985, 1997) and BS 6841 (1987) that are now available to us. Two standard codes can yield unfortunately different assessment results even for a single measured vibration signal. Possible reasons for such different results are pointed out and, furthermore, related questions that should be re-examined in the future are raised in this paper.

  • PDF

THE ROAD TO THE 85 DB(A) NOISE FENCE IN QUEENSLAND: VALUES, POLITICS, AND PUBLIC POLICY

  • Eddington, Ian;Gapp, Rod;James, Julie
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.631-637
    • /
    • 1994
  • For at least 14 years after the publication of minimum permissible exposure limits that would largely eradicate industrial deafness, statute legislation in Queensland remained unchanged and ineffective. Industrial deafness continued to occur. New legislation, introduced in 1989 and amended in 1993, and based on a duty of care responsibility incumbent on all, may remedy this situation. The new legislation is examined and comments are made about the values inherent in the new approach. It is concluded that public policy strategists may increase the likelihood of success of they ensure that the duty of care provisions (together with the general provisions of the Act) are backed up by innovative complementary economic, financial and marketing incentives.

  • PDF

A Study on Diagnostic Criteria of Noise-Induced Hearing Loss among Workers in an Iron Foundry (철강공장 근로자를 대상으로 살펴본 소음성 난청 진단기준에 관한 조사)

  • Kim, Ji-Yong;Lim, Hyun-Sul;Cheong, Hae-Kwan;Moon, Ok-Ryun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.371-386
    • /
    • 1993
  • This study was carried out to evaluate diagnostic criteria of noise-induced hearing loss (NIHL) among-workers in an iron foundry. Of 1,093 workers under the observation of noise-specific health examination, 184 workers were selected by way of first and second screening audiometric examination. A questionnaire survey, otological examinations, Rinne test and audiometric test were performed and the results were as follows ; The degree of hearing impairment in the left ear was more severe than in the right ear (p<0.05). The difference between hearing threshold of the first and the second hearing test at 1,000 Hz was about 5 dB with a narrow range of deviations while the difference at 4,000 Hz was about -7 dB with a wide range. Of the total study workers, 84.8% were tested within 15 hours away from noise exposure, and the rest after 16 hours. This study has identified that mean hearing loss at 4,000 Hz showed a significant statistical difference among the two study groups while mean hearing loss by 4-divided classification did not. The same phenomena were observed between the group with and without tinnitus and between the group with and without difficulty in hearing (p<0.05). Among 184 workers, 10 workers (5.4%) diagnosed as NIHL by old diagnostic criteria in contrast to 150 workers diagnosed as NIHL by the new diagnostic criteria. There was a significant difference between the two groups in the average hearing loss at 4,000 Hz and 4-divided classification (p<0.01), but there were no significant differences in age, the duration of employment, blood pressure and the duration wearing the personal hearing protector (p>0.05). If we apply Early Loss Index (ELI) method, some workers in younger age group diagnosed as NIHL by the new diagnostic criteria were fallen into within the normal range. In the mean time older age group show reverse results in contrast to the above finding. It is too early to confirm the value of the usage of the new diagnostic criteria in hearing examination. Further study is called for to verify the value of this criteria.

  • PDF

Usefulness Evaluation of Low-dose CT for Emphysema : Compared with High-resolution CT (폐기종에 대한 저선량 CT의 유용성 평가: 고해상도 CT와 비교)

  • Lee, Won-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.329-336
    • /
    • 2016
  • The purpose of this study was to evaluate the usefulness of low-dose CT (LDCT) for emphysema compared with high-resolution CT (HRCT). Measurements of radiation dose and noise were repeated 3 times in same exposure condition which was similar with obtaining HRCT and LDCT images. We analysed reading results of 146 subjects. Six images per participants selected for emphysema grading. Emphysema was graded for all 6 zones on the left and right sides of the lungs by the consensus reading of two chest radiologists using a 4-point scale. Between the HRCT and LDCT images, diagnostic differences and agreements for emphysema were analyzed by McNemar's and unweighted kappa tests, and radiation doses and noise by a Mann-Whitney U-test, using the SPSS 19.0 program. Radiation dose from HRCT was significantly higher than that of LDCT, but the noise was significantly lower in HRCT than in LDCT. Diagnostic agreement for emphysema between HRCT and LDCT images was excellent (k-value=0.88). Emphysema grading scores were not significantly different between HRCT and LDCT images for all six lung zones. Emphysema grading scores from LDCT images were significantly correlated with increased scores on HRCT images (r=0.599, p < 0.001). Considering the tradeoff between radiation dose and image noise, LDCT could be used as the gold standard method instead of HRCT for emphysema detection and grading.

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

Analysis of the Relationships according to the Frame (f/s) Change of Cine Imaging in Coronary Angiographic System: With Focus on FOV Enlargement and Live Zoom (심장 혈관 조영장치에서의 프레임 레이트(f/s) 변화에 따른 상관 관계 분석 : FOV 확대와 Live Zoom을 중점으로)

  • Kim, Won Hyo;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.845-852
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing absorbed dose according to changes in the number of frames in coronary angiography, also depending whether the zoom mode is FOV enlargement or Zoom Live. Moreover, for appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring the noise strength expressed by the standard deviation (SD), the signal to noise ratio (SNR) and contrast to noise ratio (CNR). The study was conducted with an anthropomorphic phantom on an angio-system. The linear relationship between the frame rate and the radiation dose was evident. On the contrary, the indices of image quality (SD, SNR, and CNR) were almost constant irrespective of the number of frames. The difference depending on the zoom mode was not statistically significant for DAP, air kerma, and SD (p > 0.05). However, SNR and CNR were statistically different between FOV enlargement and Zoom Live. In conclusion, since the image quality was not degraded significantly with the decreasing frame rate from 30, 15, to 7.5 f/s and the radiation dose evidently decreases in almost exactly linear proportion to the decreasing frame rate, the number of frames per second needs to be maintained as low as reasonably achievable. As for the dependence on the zooming mode, the Live Zoom mode showed statistically significant improvement in the image quality indices of SNR and CNR and it justifies active use of the Live Zoom mode which enables real-time image enlargment without additional radiation dose.

Assessment of the level and identification of airborne molds by the type of water damage in housing in Korea (국내 주택에서 물 피해 유형에 따른 부유곰팡이 농도 수준 평가 및 동정 분석)

  • Lee, Ju Yeong;Hwang, Eun Seol;Lee, Jeong-Sub;Kwon, Myunghee;Chung, Hyen Mi;Seo, SungChul
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.355-361
    • /
    • 2018
  • Mold grows more easily when humidity is higher in indoor spaces, and as such is found more often on wetted areas in housing such as walls, toilets, kitchens, and poorly managed spaces. However, there have been few studies that have specifically assessed the level of mold in the indoor spaces of water-damaged housing in the Republic of Korea. We investigated the levels of airborne mold according to the characteristics of water damage types and explored the correlation between the distribution of mold genera and the characteristics of households. Samplings were performed from January 2016 to June 2018 in 97 housing units with water leakage or condensation, or a history of flooding, and in 61 general housing units in the metropolitan and Busan area, respectively. Airborne mold was collected on MEA (Malt extract agar) at flow rate of 100 L/min for 1 min. After collection, the samples were incubated at $25^{\circ}C$ for 120 hours. The cultured samples were counted and corrected using a positive hole conversion table. The samples were then analyzed by single colony culture, DNA extraction, gene amplification, and sequencing. By type of housing, concentrations of airborne mold were highest in flooded housing, followed by water-leaked or highly condensed housings, and then general housing. In more than 50% of water-damaged housing, the level of airborne mold exceeded the guideline of Korea's Ministry of Environment ($500CFU/m^3$). Of particular concern was the fact that the I/O ratio of water-damaged housing was greater than 1, which could indicate that mold damage may occur indoors. The distribution patterns of the fungal species were as follows: Penicillium spp., Cladosporium spp. (14%), Aspergillus spp. (13%) and Alternaria spp. (3%), but significant differences of their levels in indoor spaces were not found. Our findings indicate that high levels of mold damage were found in housing with water damage, and Aspergillus flavus and Penicillium brevicompactum were more dominant in housing with high water activity. Comprehensive management of flooded or water-damaged housing is necessary to reduce fungal exposure.