• Title/Summary/Keyword: no-end connections

Search Result 21, Processing Time 0.032 seconds

Behavior and design of stainless steel tubular member welded end connections

  • Kiymaz, Guven;Seckin, Edip
    • Steel and Composite Structures
    • /
    • v.17 no.3
    • /
    • pp.253-269
    • /
    • 2014
  • Among the various alternatives to make a steel tubular member connection, making a slotted and gusset plate welded connection is one of the most frequently preferred alternatives. This type of connection is essentially an end connection that is made by slotting the tube longitudinally, inserting the gusset plate and then placing longitudinal fillet welds at the tube-to-plate interface. In this paper an experimental study on the behaviour of such connections in stainless steel is presented. 24 specimens were tested under concentrically applied axial tensile forces for varying tube-to-gusset plate weld lengths. Both circular and box section members were considered in the test program. Load-deformation curves were obtained and comparisons were made in terms of strength and ductility. The results obtained from the study were then critically examined and compared with currently available design guidance for slotted gusset plate welded tubular end connections. It is noted that no specific rules exist in international specifications on structural stainless steel which cover the design of such connections. Therefore, the results of this study are compared with the existing design rules for carbon steel.

Connection Management Scheme using Mobile Agent System

  • Lim, Hee-Kyoung;Bae, Sang-Hyun;Lee, Kwang-Ok
    • Journal of Integrative Natural Science
    • /
    • v.11 no.4
    • /
    • pp.192-196
    • /
    • 2018
  • The mobile agent paradigm can be exploited in a variety of ways, ranging from low-level system administration tasks to middle ware to user-level applications. Mobile agents can be useful in building middle-ware services such as active mail systems, distributed collaboration systems, etc. An active mail message is a program that interacts with its recipient using a multimedia interface, and adapts the interaction session based on the recipient's responses. The mobile agent paradigm is well suitable to this type of application, since it can carry a sender-defined session protocol along with the multimedia message. Mobile agent communication is possible via method invocation on virtual references. Agents can make synchronous, one-way, or future-reply type invocations. Multicasting is possible, since agents can be aggregated hierarchically into groups. A simple check-pointing facility has also been implemented. Another proposed solution is to use multi agent computer systems to access, filter, evaluate, and integrate this information. We will present the overall architectural framework, our agent design commitments, and agent architecture to enable the above characteristics. Besides, the each information needed a mobile agent system such as text, graphic, image, audio and video etc, constructed a great capacity multimedia database system. However, they have problems in establishing connections over multiple subnetworks, such as no end-to-end connections, transmission delay due to ATM address resolution, no QoS protocols. We propose a new connection management scheme in the thesis to improve the connection management involved of mobile agent systems.

Experimental study of the behavior of beam-column connections with expanded beam flanges

  • Ma, Hongwei;Wang, Jiwei;Lui, Eric M.;Wan, Zeqing;Wang, Kun
    • Steel and Composite Structures
    • /
    • v.31 no.3
    • /
    • pp.319-327
    • /
    • 2019
  • This paper describes an experimental study of steel beam-column connections with or without expanded beam flanges with different geometries. The objectives of this study are to elucidate the cyclic behavior of these connections, identify the location of the plastic hinge zone, and provide useful test data for future numerical simulations. Five connection specimens are designed and tested under cyclic load. The test setup consists of a beam and a column connected together by a connection with or without expanded beam flanges. A constant axial force is applied to the column and a time varying point load is applied to the free end of the beam, inducing shear and moment in the connection. Because the only effect to be studied in the present work is the expanded beam flange, the sizes of the beam and column as well as the magnitude of the axial force in the column are kept constant. However, the length, width and shape of the expanded beam flanges are varied. The responses of these connections in terms of their hysteretic behavior, failure modes, stiffness degradation and strain variations are experimentally obtained and discussed. The test results show that while the influence of the expanded beam flanges on hysteretic behavior, stiffness degradation and energy dissipation capacity of the connection is relatively minor, the size of the expanded beam flanges does affect the location of the plastic hinge zone and strain variations in these beam-column joints. Furthermore, in terms of ductility, moment and rotational capacities, all five connections behave well. No weld fracture or premature failure occurs before the formation of a plastic hinge in the beam.

Seismic response and energy dissipation in partially restrained and fully restrained steel frames: An analytical study

  • Reyes-Salazar, Alfredo;Haldar, Achintya
    • Steel and Composite Structures
    • /
    • v.1 no.4
    • /
    • pp.459-480
    • /
    • 2001
  • The damage suffered by steel structures during the Northridge (1994) and Kobe (1995) earthquakes indicates that the fully restrained (FR) connections in steel frames did not behave as expected. Consequently, researchers began studying other possibilities, including making the connections more flexible, to reduce the risk of damage from seismic loading. Recent experimental and analytical investigations pointed out that the seismic response of steel frames with partially restrained (PR) connections might be superior to that of similar frames with FR connections since the energy dissipation at PR connections could be significant. This beneficial effect has not yet been fully quantified analytically. Thus, the dissipation of energy at PR connections needs to be considered in analytical evaluations, in addition to the dissipation of energy due to viscous damping and at plastic hinges (if they form). An algorithm is developed and verified by the authors to estimate the nonlinear time-domain dynamic response of steel frames with PR connections. The verified algorithm is then used to quantify the major sources of energy dissipation and their effect on the overall structural response in terms of the maximum base shear and the maximum top displacement. The results indicate that the dissipation of energy at PR connections is comparable to that dissipated by viscous damping and at plastic hinges. In general, the maximum total base shear significantly increases with an increase in the connection stiffness. On the other hand, the maximum top lateral displacement $U_{max}$ does not always increase as the connection stiffness decreases. Energy dissipation is considerably influenced by the stiffness of a connection, defined in terms of the T ratio, i.e., the ratio of the moment the connection would have to carry according to beam line theory (Disque 1964) and the fixed end moment of the girder. A connection with a T ratio of at least 0.9 is considered to be fully restrained. The energy dissipation behavior may be quite different for a frame with FR connections with a T ratio of 1.0 compared to when the T ratio is 0.9. Thus, for nonlinear seismic analysis, a T ratio of at least 0.9 should not be considered to be an FR connection. The study quantitatively confirms the general observations made in experimental results for frames with PR connections. Proper consideration of the PR connection stiffness and other dynamic properties are essential to predict dynamic behavior, no matter how difficult the analysis procedure becomes. Any simplified approach may need to be calibrated using this type of detailed analytical study.

The Korean Elementary Students' Conceptions of the Simple Electric Circuit

  • Seo, Sang-Oh;Kwon, Jae-Sool
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.5
    • /
    • pp.944-956
    • /
    • 2002
  • The purpose of this study was to investigate students' conceptions of the simple electric circuit using a battery and a bulb. 19 fourth grade students from a rural elementary school in Korea participated in this study. Data on the children's understandings of electric circuit were collected through three sources; prediction tests, drawing tests and individual interviews. The prediction tests were paper and pencil tests composed of 10 problems, predicting whether bulbs in 10 simple circuit diagrams would light. For each prediction, the children were asked to provide a written explanation of their thinking. The drawing tests consisted of 6 problems. One was to draw the inside of the bulb base, and the others were to make the wire connections between a battery and a bulb in the diagrams, to light the bulb. The interviews were conducted with seven children who showed differing degrees of understanding. No student was aware of the wire connections inside the bulb base. Many students stated whether the bulb would light or not, according to the tip of the bulb contacting the positive battery terminal and an end of wire contacting the negative battery terminal. Most of them thought that the tip of the bulb should contact the positive battery terminal, so that the bulb would light. In short, students did not use a scientific conception of electric current to predict and explain the electric circuit.

Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections with Special Moment Frame Details (특수모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가)

  • Kim, Seon Hoon;Lee, Deuck Hang;Kim, Yong Kyeom;Lee, Sang Won;Yeo, Un Yong;Park, Jung Eun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.203-211
    • /
    • 2023
  • For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.

The Impact of Traditional Market Properties and Relationship Quality on Customer Value : Approach from the viewpoint of the Means-end Chain Theory

  • Cho, Hee-Young;Han, Sang-Ho;Yang, Hoe-Chang
    • Journal of Distribution Science
    • /
    • v.12 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose - This study investigated relationship quality and/or loyalty, from the viewpoint that merchants and consumers could develop the traditional market. It reorganized variables to find the conditions of values that could stimulate consumers' motives to revive the traditional market. Research Design, data, and methodology - This study employed 202 copies of effective questionnaires, based on the data of Yang & Ju (2012), to conduct correlation, regression, and structured equation modeling (SEM). Results - The results emphasized product and store atmosphere as store selection attributes to consider in the minimum error correction (MEC) model; service factor was not significant. Further, consumers valued relationship quality in the test of mediated effects of the sub-factors of store selection attributes, including consumers' social and emotional value. The relationship quality significantly influenced consumers' value in traditional markets that needed to improve and develop using several variables. Conclusions - This study revealed connections between attributes, consequences, and values using the causal relation model, to generate an optimal model based on a practical and theoretical background and proposed ways to obtain consumer-related information easily.

An improved performance of TCP traffic connection congestion control in wireless networks (무선네트워크에서 TCP 트래픽 연결 혼잡제어에 관한 성능 개선)

  • Ra Sang-dong;Na Ha-sun;Park Dong-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.264-270
    • /
    • 2006
  • In this paper we verified that the window based TCP performance of throughput can be improved by the traffic connection efficiency. and have studied the performance of traffic congestion control that is controlling transmission rate. In wireless network, the bidirectional node is run by estimating the usage rate of link of error control idle and the throughput is shown by transmitting segments. The throughput rate shows almost no delay due to the bidirectional traffic connection efficiency up to the allowable point as increasing the transport rate by the critical value, depending on the size of end-to-end node queue of the increase of transport rate. This paper reports the performance improvement as the number of feedback connection traffic congestion control increases because of the increase of the number of asynchronous transport TCP connections.

Seismic Response of Haunch Repaired Steel MRFs: A Case Study (헌치로 보강된 철골모멘트 골조의 지진 응답: 사례연구)

  • 이철호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.173-181
    • /
    • 1997
  • To investigate the effects of haunch repair on the system seismic performance of steel moment-resisting frames (steel MRFs), a case study was conducted for a 13-story frame damaged during the 1994 Northridge earthquake. It was assumed that only those locations with reported damage would be repaired with haunches. A new analytical modeling technique for the dual panel zone developed by the author was incorporated in the analysis. Both the inelastic static and dynamic analyses did not indicate detrimental side effects resulting from the repair. As a result of the increased strength in dual panel zones, yielding in these locations were eliminated and larger plastic rotation demand occurred in the beams next to the shallow end of the haunches. Nevertheless, the beam plastic rotation demand produced by the Sylmar record of 1994 Northridge earthquake was still limited to 1.7% radians. The repair resulted in a minor increase in earthquake energy input. In the original structure, the panel zones should dissipate about 80%(for the Oxnard record) and 70%(for the Sylmar record) of the absorbed energy, assuming no brittle failure of moment connections. After repair, the energy dissipated in the panel zones and beams were about equal.

  • PDF

Structural Performance of H-shaped Column-Rafter Connection in the P.E.B Systematic Steel Frames (P.E.B 시스템 강골조에서 H형강 기둥 - Rafter 접합부의 구조성능)

  • Kim, Jong Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.347-356
    • /
    • 2005
  • Recently, pre-engineering building (P.E.B.) systematic frames are increasingly being used in steel factory buildings, but almost of the related techniques are dependent on the engineering program (e.g, MBS, LTI), which is usually imported from other countries. These are designed under the AISC-ASD because at present there is no Korean design code for P.E.B. frames. Also, there are few studies onbehaviour and we need to develop the element techniques by using H-shaped components.In particular, there is a tendency towards overestimated design because column-rafter connections have been designed with extended end plate type joint, which is treated asrigid joint,so structural examinations are needed. Therefore, this study represents a basic step in ascertaining the application of P.E.B. systematic frames by using H-shaped column-rafter connectionwith flush type end plate. Its structural performance is compared with that of existing extended type joint using a structural performance test. The structural behaviour of specimen was understood qualitatively and the possibility of application (e.g, design aid charts) of semi-connection (flush type) with H-shaped column-rafter was determined.