• Title/Summary/Keyword: new-type TMD

Search Result 10, Processing Time 0.031 seconds

Vibration control of lamp posts in Seohae Bridge using TMD (TMD를 이용한 서해대교 가로등의 진동제어)

  • 박찬민;박종칠;황성호;김용길;권오병
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.252-256
    • /
    • 2003
  • Tuned Mass Damper(TMD) has been applied in various fields in order to mitigate these vibrations. The shape or configuration of TMDs being unrestricted, a large panel of designs is possible to improve their effectiveness and economical-efficiency, where ingenuity plays an essential role and is required. This study presents an application of a new-type TMD on lamp posts to reduce vibrations induced by loads with large frequency domains such as wind loads. It is shown that the proposed TMD absorbs efficiently the energy without being restricted by frequency contents of the vibration.

  • PDF

Softening and hardening tuned mass dampers

  • Khalili, Mohammad Khalil;Badamchi, Karim
    • Earthquakes and Structures
    • /
    • v.14 no.5
    • /
    • pp.459-465
    • /
    • 2018
  • Reducing response of buildings during earthquakes by mass dampers, has been examined in many articles and books. Nowadays, many researchers are trying to realistically examine this type of dampers by new methods of performance. In this paper, for the better study of tuned mass damper (TMD), two schematic models are presented for a passive TMD with softening stiffness (softening TMD) and a passive TMD with hardening stiffness (hardening TMD). Then by modeling and analysis of the damper on a single degree of freedom (SDOF) structure and an 11-story steel building, the dampers performance was evaluated. State space was used for damper and structure modeling and to solve nonlinear equations, the Newton-Raphson method was used. The results show that when the structure is subjected to the Chi-Chi earthquake, response of the sixth floor in the system without TMD reduces 54.0% in comparison to the structure with softening TMD. This percentage of reduction for hardening TMD is 55.0%. Also for the Tabas earthquake, reduction in the RMS acceleration of the sixth floor in the system with hardening TMD is 96.2% more than the structure without TMD. This percentage of reduction for hardening TMD is 96.3%.

Experimental study on the effect of EC-TMD on the vibration control of plant structure of PSPPs

  • Zhong, Tengfei;Feng, Xin;Zhang, Yu;Zhou, Jing
    • Smart Structures and Systems
    • /
    • v.29 no.3
    • /
    • pp.457-473
    • /
    • 2022
  • A high-frequency vibration control method is proposed in this paper for Pumped Storage Power Plants (PSPPs) using Eddy Current Tuned Mass Damper (EC-TMD), based on which a new type of EC-TMD device is designed. The eddy current damper parameters are optimized by numerical simulation. On this basis, physical simulation model tests are conducted to compare and study the effect of structural performance with and without damping, different control strategies, and different arrangement positions of TMD. The test results show that EC-TMD can effectively reduce the control effect under high-frequency vibration of the plant structure, and after the additional damping device forms EC-TMD, the energy dissipation is further realized due to the intervention of eddy current damping, and the control effect is subsequently improved. The Multi-Tuned Mass Damper (MTMD) control strategy broadens the tuning band to improve the robustness of the system, and the vibration advantage is more obvious. Also, some suggestions are made for the placement of the dampers to promote their application.

Performance of TMDs on nonlinear structures subjected to near-fault earthquakes

  • Domizio, Martin;Ambrosini, Daniel;Curadelli, Oscar
    • Smart Structures and Systems
    • /
    • v.16 no.4
    • /
    • pp.725-742
    • /
    • 2015
  • Tuned mass dampers (TMD) are devices employed in vibration control since the beginning of the twentieth century. However, their implementation for controlling the seismic response in civil structures is more recent. While the efficiency of TMD on structures under far-field earthquakes has been demonstrated, the convenience of its employment against near-fault earthquakes is still under discussion. In this context, the study of this type of device is raised, not as an alternative to the seismic isolation, which is clearly a better choice for new buildings, but rather as an improvement in the structural safety of existing buildings. Seismic records with an impulsive character have been registered in the vicinity of faults that cause seismic events. In this paper, the ability of TMD to control the response of structures that experience inelastic deformations and eventually reach collapse subject to the action of such earthquakes is studied. The results of a series of nonlinear dynamic analyses are presented. These analyses are performed on a numerical model of a structure under the action of near-fault earthquakes. The structure analyzed in this study is a steel frame which behaves as a single degree of freedom (SDOF) system. TMD with different mass values are added on the numerical model of the structure, and the TMD performance is evaluated by comparing the response of the structure with and without the control device.

Performance of tuned mass dampers against near-field earthquakes

  • Matta, E.
    • Structural Engineering and Mechanics
    • /
    • v.39 no.5
    • /
    • pp.621-642
    • /
    • 2011
  • Passive tuned mass dampers (TMDs) efficiently suppress vibrations induced by quasi-stationary dynamic inputs, such as winds, sea waves or traffic loads, but may prove of little use against pulse-like excitations, such as near-field (NF) ground motions. The extent of such impairment is however controversial, partly due to the different evaluation criteria adopted within the literature, partly to the limited number of seismic records used in most investigations. In this study, three classical techniques and two new variants for designing a TMD on an SDOF structure are tested under 338 NF records from the PEER NGA database, including 156 records with forward-directivity features. Percentile response reduction spectra are introduced to statistically assess TMD performance, and TMD robustness is verified through Monte Carlo simulations. The methodology is extended to a variety of MDOF bending-type and shear-type frames, and simulated on a case study building structure recently constructed in Central Italy.Results offer an interesting insight into the performance of TMDs against NF earthquakes, ultimately showing that, if properly designed and sufficiently massive, TMDs are effective and robust even in the face of pulse-like ground motions. The two newly proposed design techniques are shown to generally outperform the classical ones.

Effectiveness of design procedures for linear TMD installed on inelastic structures under pulse-like ground motion

  • Quaranta, Giuseppe;Mollaioli, Fabrizio;Monti, Giorgio
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.239-260
    • /
    • 2016
  • Tuned mass dampers (TMDs) have been frequently proposed to mitigate the detrimental effects of dynamic loadings in structural systems. The effectiveness of this protection strategy has been demonstrated for wind-induced vibrations and, to some extent, for seismic loadings. Within this framework, recent numerical studies have shown that beneficial effects can be achieved by placing a linear TMD on the roof of linear elastic structural systems subjected to pulse-like ground motions. Motivated by these positive outcomes, closed-form design formulations have been also proposed to optimize the device's parameters. For structural systems that undergo a near-fault pulse-like ground motion, however, it is unlikely that their dynamic response be linear elastic. Hence, it is very important to understand whether such strategy is effective for inelastic structural systems. In order to provide new useful insights about this issue, the paper presents statistical results obtained from a numerical study conducted for three shear-type hysteretic (softening-type) systems having 4, 8 and 16 stories equipped with a linear elastic TMD. The effectiveness of two design procedures is discussed by examining the performances of the protected systems subjected to 124 natural pulse-like earthquakes.

Clinical Characteristics of Headaches in Temporomandibular Disorder Patients : Primary Headache vs Headache Attributed to TMD (측두하악장애 환자의 두통 양상의 분류 : 일차성 두통 vs 측두하악장애로 인한 두통)

  • Ryu, Ji-Won;Bae, Kook-Jin;Hong, Seong-Ju;Yoon, Chang-Lyuk;Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.325-331
    • /
    • 2009
  • The objective of this study was to describe the prevalence of the headache attributed to Temporomandibular disorder(TMD) symptoms and to investigate the relationships of headache and TMD. 66 patients seeking care for signs and symptoms of Temporomandibular disorders(TMD) and Orofacial pain in the department of oral medicine, Dental Hospital, Chosun University, from January, 2008 to June, 2008, were recruited. The obtained results were as follows : 1. A muscle and TMJ origin combined was the most common in study populations(54.55%), grouped as TMD classification. 2. Tension type headache was the most common in study population(89.39%), grouped as headache classification. 3. 36 patients out of 66(54.55%) had headaches which related to TMD. 4. Out of 36 patients who had suffered the headache which were attributed to TMD, 19 patients(52.78%) described that their headache related to TMD was different from their own primary headaches. In conclusion, headache attributed to TMD is relatively common in the patients who had headaches and TMD symptoms together. And the new headache patterns may related to headache and TMD chronification. Larger-scale studies and more specified and controlled comparison study is needed to confirm the relationship between the headache and TMD.

Nonlinear Tuned Mass Damper for self-excited oscillations

  • Gattulli, Vincenzo;Di Fabio, Franco;Luongo, Angelo
    • Wind and Structures
    • /
    • v.7 no.4
    • /
    • pp.251-264
    • /
    • 2004
  • The effects of a class of nonlinear Tuned Mass Dampers on the aeroelastic behavior of SDOF systems are investigated. Unlike classical linear TMDs, nonlinear constitutive laws of the internal damping acting between the primary oscillator and the TMD are considered, while the elastic properties are keept linear. The perturbative Multiple Scale Method is applied to derive a set of bifurcation equations in the amplitude and phase and a parametric analysis is performed to describe the postcritical scenario of the system. Both cubic- and van der Pol-type dampings are considered and the dependence of the limit-cycle amplitudes on the system parameters is studied. These new results, compared with the previously obtained bifurcation scenario of a SDOF aeroelastic oscillator equipped with a linear TMD, show a detrimental effect on the maximum limit-cycle amplitude reduction of the nonlinear TMD. However, the analyses evidence that in the parameter region away from the perfect tuning condition the nonlinear connection can be used to tune the system with an enhancement of the limit-cycle amplitude reduction.

Vibration Control of Lamp posts On Bridge using Tuned Mass Dampers (동조질량감쇠기를 이용한 교량 가로등의 진동제어)

  • Ha, Dong-Ho;Kim, Yong-Gyu;Lee, Chang-Hyung;Yoo, Moon-Sig;Park, Dong-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.432-439
    • /
    • 2006
  • Long span, high-rise bridges are rapidly increasing nowadays. Because of high flexibility, such bridges are easily excited by winds, vehicles, and pedestrians. The vibration of bridge induces a vibration of lamp post and pillar. Wind loads can also excite lamp posts and traffic signal structures directly. Because of low damping, such vibrations of lamp post are frequently amplified and come to collapse or lamp failure. In addition, such vibration makes the maintenance cycle shorter and increases social cost. We conducted vibration tests and identified the dynamic characteristics of two types lamp posts, and proposed tuned mass dampers to control the vibrations. Established models of the lamp posts present the dynamic characteristics of the structures very well and they are used to design TMDs. In this study, we suggested a new-type TMD model that is small, simple, economic and effective to suppress the vibration of lamp posts. The efficiency of TMD was examined by numerically and is to be examined experimentally.

  • PDF

Multiple wall dampers for multi-mode vibration control of building structures under earthquake excitation

  • Rahman, Mohammad Sabbir;Chang, Seongkyu;Kim, Dookie
    • Structural Engineering and Mechanics
    • /
    • v.63 no.4
    • /
    • pp.537-549
    • /
    • 2017
  • One of the main concerns of civil engineering researchers is developing or modifying an energy dissipation system that can effectively control structural vibrations, and keep the structural response within tolerable limits during unpredictable events like earthquakes, wind and any kind of thrust load. This article proposes a new type of mass damper system for controlling wideband earthquake vibrations, called Multiple Wall Dampers (MWD). The basic principle of the Tuned Mass Damper (TMD) was used to design the proposed wall damper system. This passive energy dissipation system does not require additional mass for the damping system because the boundary wall mass of the building was used as a damper mass. The multi-mode approach was applied to determine the location and design parameters of the dampers. The dampers were installed based on the maximum amplitude of modes. To optimize the damper parameters, the multi-objective optimization Response Surface Methodology was used, with frequency response and maximum displacement as the objective functions. The obtained structural responses under different earthquake forces demonstrated that the MWD is one of the most capable tools for reducing the responses of multi-storied buildings, and this system can be practically used for new and existing building structures.