1 |
He, Y.C. and Li, Q. (2014), "Dynamic responses of a 492-m-high tall building with active tuned mass damping system during a typhoon", Struct. Control Hlth. Monit., 21(5), 705-720.
|
2 |
Kareem, A., Kijewski, T. and Tamura, Y. (1999), "Mitigation of motions of tall buildings with specific examples of recent applications", Wind Struct., 2(3), 201-251.
DOI
|
3 |
Lin, G.L., Lin, C.C., Chen, B.C. and Soong, T.T. (2015), "Vibration control performance of tuned mass dampers with resettable variable stiffness", Eng. Struct., 83, 187-197.
DOI
|
4 |
Lin, J.L., Liu, T.H. and Tsai, K.C. (2015), "Real-valued modal response history analysis for asymmetric-plan buildings with nonlinear viscous dampers", Soil Dyn. Earthq. Eng., 77, 97-110.
DOI
|
5 |
Nagarajaiah, S. (2009), "Adaptive passive, semiactive, smart tuned mass dampers: identification and control using empirical mode decomposition, Hilbert transform, and short term Fourier transform", Struct. Control Hlth. Monit., 16(78), 800-841.
DOI
|
6 |
Oller, S. (2014), Nonlinear Dynamics of Structures, Springer, New York, USA.
|
7 |
Pourzeynali, S., Lavasani, H. and Modarayi, A. (2007), "Active control of high rise building structures using fuzzy logic and genetic algorithms", Eng. Struct., 29(3), 346-357.
DOI
|
8 |
Rafieipour, M.H., Ghorbani-Tanha, A.K., Rahimian M and Mohammadi-Ghazi R (2014), "A novel semi-active TMD with folding variable stiffness spring", Earthq. Eng. Eng. Vib., 13(3), 509-518.
DOI
|
9 |
Ghaffarzadeh, H., Dehrod, E.A. and Talebian, N. (2013), "Semiactive fuzzy control for seismic response reduction of building frames using variable orifice dampers subjected to near-fault earthquakes", J. Vib. Control, 19(13), 1980-1998.
DOI
|
10 |
Sadek, F., Mohraz, B., Taylor, A.W. and Chung, R.M. (1997), "A method of estimating the parameters of tuned mass dampers for seismic applications", Earthq. Eng. Struct. D., 26(6), 617-636.
DOI
|
11 |
Shum, K. (2015), "Tuned vibration absorbers with nonlinear viscous damping for damped structures under random load", J. Sound Vib., 346, 70-80.
DOI
|
12 |
Varadarajan, N. and Nagarajaiah, S. (2004), "Wind response control of building with variable stiffness tuned mass damper using empirical mode decomposition/Hilbert transform", J. Eng. Mech., 130(4), 451-458.
DOI
|
13 |
Soleymani, M. and Khodadadi, M. (2014), "Adaptive fuzzy controller for active tuned mass damper of a benchmark tall building subjected to seismic and wind loads", Struct. Des. Tall Spec., 23(10), 781-800.
DOI
|
14 |
Soto, M.G. and Adeli, H. (2013), "Tuned mass dampers", Arch. Comput. Meth. E., 20(4), 419-431.
DOI
|
15 |
Sun, C., Nagarajaiah, S. and Dick, A. (2014), "Experimental investigation of vibration attenuation using nonlinear tuned mass damper and pendulum tuned mass damper in parallel", Nonlin. Dyn., 78(4), 2699-2715.
DOI
|
16 |
Viet, L. and Nghi, N. (2014), "On a nonlinear single-mass twofrequency pendulum tuned mass damper to reduce horizontal vibration", Eng. Struct., 81, 175-180.
DOI
|
17 |
Zahrai, S.M., Zare, A., Khalili, M.K. and Asnafi, A. (2013), "Seismic design of fuzzy controller for semi-active tuned mass dampers using top stories as the mass", Asian J. Civil Eng. (BHRC), 14(3), 383-396.
|
18 |
Chey, M.H., Chase, J.G., Mander, J.B. and Carr, A.J. (2010b), "Semi-active tuned mass damper building systems: design", Earthq. Eng. Struct. D., 39(1), 119-139.
|
19 |
Bajkowski, J.M., Dyniewicz, B. and Bajer, C.I. (2016), "Semiactive damping strategy for beams system with pneumatically controlled granular structure", Mech. Syst. Signal Pr., 70, 387-396.
|
20 |
Chey, M.H., Chase, J.G., Mander, J.B. and Carr, A.J. (2010a), "Semi-active tuned mass damper building systems: application", Earthq. Eng. Struct. D., 39(1), 69-89.
DOI
|
21 |
Das, D., Datta, T. and Madan, A. (2012), "Semiactive fuzzy control of the seismic response of building frames with MR dampers", Earthq. Eng. Struct. D., 41(1), 99-118.
DOI
|
22 |
Eason, R., Sun, C., Dick, A. and Nagarajaiah, S. (2013), "Attenuation of a linear oscillator using a nonlinear and a semiactive tuned mass damper in series", J. Sound Vib., 332(1), 154-166.
DOI
|
23 |
Farshi, B. and Assadi, A. (2011), "Development of a chaotic nonlinear tuned mass damper for optimal vibration response", Commun. Nonlin. Sci., 16(11), 4514-4523.
DOI
|