• Title/Summary/Keyword: new construction material

Search Result 670, Processing Time 0.03 seconds

Practical Application of Nonshrinkage Concrete Using CSA Expansive Additive (CSA 팽창재를 사용한 무수축 콘크리트 현장적용사례 연구)

  • 김병권;조동원;김상용;신영인
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.620-626
    • /
    • 1997
  • In this study. use if CSA expansive additive for concrete is discussed, particulary applications to partial compacting the concrete structure of spillway gate located in Youngjong new airport construction field. Before the field applications, several basic laboratory test were carried out in order to clarify the material characteristics and to decide mix proportions. As the result the concrete using CSA expansive additive show similar workability and compressive strength to that of OPC concrete. Forethemore, it can be concluded that the use of CSA component is effective to prevent shrinkage crack and to achive volume stabiliy of concrete structure.

  • PDF

Deflection prediction of inflatable flat panels under arbitrary conditions

  • Mohebpour, S.R.
    • Structural Engineering and Mechanics
    • /
    • v.45 no.6
    • /
    • pp.853-865
    • /
    • 2013
  • Inflatable panels made of modern and new textile materials can be inflated at high pressure to have a high mechanical strength. This paper is based on the finite element method as a general solution to determine the characteristics of deformed inflatable panels at high pressure in various end and loading conditions. Proposed method is based on the construction of weak form of formulation and application of Reduced Integration Element method (RIE) to solve the numerical problem of shear locking. The numerical results are validated as an outcome of comparison with other published results.

Rubber Material Development and Performance Evaluation of Diaphragm Seal for Steam Generator Nozzle Dam

  • Woo, Chang-Su;Song, Chi-Sung;Lee, Han-Chil;Kwon, Jin-Wook
    • Elastomers and Composites
    • /
    • v.55 no.3
    • /
    • pp.222-228
    • /
    • 2020
  • Rubber materials, used in nuclear power plants, need high heat-oxidation resistance to curing or cracking under a heat aging environment. This is because they are applied to environments with high temperature, high humidity, and radiation exposure. Nuclear radiation causes additional hardening or degradation, therefore, rubber materials need radiation resistance that satisfies the general and any accidental conditions produced in the power plant. Therefore, in this study, we developed a rubber material with excellent heat and radiation resistance for the diaphragm seal of a nuclear steam generator nozzle dam. The rubber material greatly improved the reliability of the steam generator nozzle dam. In addition, 30 inch and 42 inch diaphragm seals were manufactured using the developed rubber material. A nozzle dam was installed in a nuclear power plant and tested under the same conditions as a steam generator to evaluate safety and reliability. In the future, the performance and safety of diaphragm seals developed through field tests of nuclear power plants will be evaluated and applied to currently operating and new nuclear power plants.

Experimental and numerical analysis of new bricks made up of polymer modified-cement using expanded vermiculite

  • Koksal, Fuat;del Coz Diaz, Juan J.;Gencel, Osman;Alvarez Rabanal, Felipe P.
    • Computers and Concrete
    • /
    • v.12 no.3
    • /
    • pp.319-335
    • /
    • 2013
  • In this paper, the properties of the cement mortar modified with styrene acrylic ester copolymer were investigated. Expanded vermiculite as lightweight aggregate was used for making the polymer modified mortar test specimens. To study the effect of polymer-cement ratio and vermiculite-cement ratio on various properties, specimens were prepared by varying the polymer-cement and vermiculite-cement ratios. Tests of physical properties such as density, water absorption, thermal conductivity, three-point flexure and compressive tests were made on the specimens. Furthermore, a coupled thermal-structural finite element model of an entire corner wall was modelled in order to study the best material configuration. The wall is composed by a total of 132 bricks of $120{\times}242{\times}54$ size, joined by means of a contact-bonded model. The use of advanced numerical methods allows us to obtain the optimum material properties. Finally, comparisons of polymer-cement and vermiculite-cement ratios on physical properties are given and the most important conclusions are exposed.

An Experimental Study on the Applicability of Converter Slag by wind fracture as Vertical Drains (풍쇄전로슬래그의 연직배수재 활용성에 관한 실험적 연구)

  • Kwon, Jung-Keun;Im, Jong-Chul;Park, Lee-Keun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1132-1141
    • /
    • 2006
  • Recently it is difficult to secure sand used in the improvement of soft ground, and so it is necessary to find alternative materials. For this reason many researchers are studying and trying to find new substitute materials. One of the materials is considered as converter slag by wind fracture which is generated in the production of steel manufacture by electric circuit. It is environment friendly since it is a recycled material and economical since it is cheaper than sand. To investigate the applicability of converter slag by wind fracture as the alternative material such as vertical drains, it is necessary to check the drainage effect of this in the field construction. In order to attain an successful design it is important to predict problems encountered in field construction. Accordingly, in this study the laboratory test was executed under different conditions in advance of applying of the field. A total of 4 cases including slag, sand+slag, pack slag and sand as vertical drains was conducted, and at the base of the laboratory test the field test was executed and analyzed.

  • PDF

Development of Composite Tension.Compression Anchor System based on the pull out resistance characteristics of Ground Anchor (지반앵커의 인발저항 특성에 따른 인장.압축 복합 시스템 개발)

  • Yeom, Ho-Hyeong;Im, Jong-Chul;Hong, Seok-Woo;Kim, Chul-Ung;Shin, Chul-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.788-795
    • /
    • 2005
  • In this study, the progressive failure and creep of the traditional ground anchor structure were decreased and a new ground anchor that can attain the required pull-out resistance even in soft sandy soils with low confining pressure was developed. Ground anchors are classified depending on the kind of stress the grout is subjected. If the grout material is subjected to tension then it is classified as tension anchor while when the grout material is subjected to compression it is classified as compression anchor. The ground anchor that possesses both the tension and compression mechanism mentioned above is known as composition anchor. It is the objective of this study to develope this type of composition anchor. The structure of the newly developed ground anchor was presented. Pull-out test in different types of soil and the behaviour during Pull-out test was also presented.

  • PDF

Effects of deficiency location on CFRP strengthening of steel CHS short columns

  • Shahabi, Razieh;Narmashiri, Kambiz
    • Steel and Composite Structures
    • /
    • v.28 no.3
    • /
    • pp.267-278
    • /
    • 2018
  • Structures may need retrofitting as a result of design and calculation errors, lack of proper implementation, post-construction change in use, damages due to accidental loads, corrosion and changes introduced in new editions of construction codes. Retrofitting helps to compensate weakness and increase the service life. Fiber Reinforced Polymer (FRP) is a modern material for retrofitting steel elements. This study aims to investigate the effect of deficiency location on the axial behavior of compressive elements of Circular Hollow Section (CHS) steel short columns. The deficiencies located vertically or horizontally at the middle or bottom of the element. A total of 43 control column and those with deficiencies were investigated in the ABAQUS software. Only 9 of them tested in the laboratory. The results indicated that the deficiencies had a significant effect on the increase in axial deformation, rupture in deficiency zone (local buckling), and decrease in ductility and bearing capacity. The damages of steel columns were responsible for resistance and stiffness drop at deficiency zone. Horizontal deficiency at the middle and vertical deficiency at the bottom of the steel columns were found to be the most critical. Using Carbon Fiber Reinforced Polymer (CFRP) as the most effective material in retrofitting the damaged columns, significantly helped the increase in resistance and rupture control around the deficiency zone.

Effect of marble waste fines on rheological and hardened properties of sand concrete

  • Djebien, R.;Belachia, M.;Hebhoub, H.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.6
    • /
    • pp.1241-1251
    • /
    • 2015
  • Faced with the growing needs of material resources and requirements of environmental protection for achieving sustainable development, it has become necessary to study and investigate all possibilities of exploring crushed and dune sand, reusing industrial wastes and by-product, and also applying new technologies including sand concrete which can replace the conventional concretes in certain structures to surmount the deficit on construction materials, conserve natural resources, lessen the burden of pollutants to protect the environment and reduce the consumption of energy sources. This experimental study is a part of development and valorization of local materials project in Skikda region (East of Algeria). It aims at studying the effects of partial replacement of sand with marble waste as fines on several fresh and hardened properties of sand concrete in order to reuse these wastes in the concrete manufacturing, resolve the environmental problems caused by them and find another source of construction materials. To achieve these objectives, an experimental program has been carried out; it was consisted to incorporate different percentages of marble waste fines (2, 4, 6, 8, 10 and 12%) in the formulations of sand concrete and study the development of several mechanical and rheological properties. We are also trying to find the optimal percentage of marble waste fine replaced in sand concrete that makes the strength of the concrete maximum. Obtained results showed that marble waste fines improve the properties of sand concrete and can be used as an additive material in sand concrete formulation.

A Study on the Analysis of 3 Dimensional Substrate Behaviour of Complex Environmental Deterioration and the Analysis of Results (방수재료 및 공법의 내구성 평가를 위한 복합열화분석용 3차원 거동대응 시험결과)

  • Song, Je-Young;Seo, Hyun-Jae;Choi, Eun-Kyu;Lee, Jung-Hun;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.189-190
    • /
    • 2018
  • KS standards mostly relate to single component material evaluation, so in cases of underground structure environments, most cannot predict the existing composite forms of deterioration, resulting in the applied waterproofing materials becoming unable to respond to these damaging factors. Current domestic waterproofing market in Korea mainly uses single-ply waterproofing materials comprised of coatings or waterproof sheets and two or more-ply composite waterproofing methods. In order to evaluate these types of composite waterproofing systems, a new test equipment and method that incorporates various deterioration conditions (joint displacement, chemical exposure, water pressure etc) was developed. In a comparison testing, the results showed that flexible type materials have higher response performance towards joint displacement than the hardened material.

  • PDF

Study on seismic retrofit of structures using SPSW systems and LYP steel material

  • Zirakian, Tadeh;Zhang, Jian
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.1-23
    • /
    • 2016
  • Steel plate shear walls (SPSWs) have been shown to be efficient lateral force-resisting systems, which are increasingly used in new and retrofit construction. These structural systems are designed with either stiffened and stocky or unstiffened and slender web plates based on disparate structural and economical considerations. Based on some limited reported studies, on the other hand, employment of low yield point (LYP) steel infill plates with extremely low yield strength, and high ductility as well as elongation properties is found to facilitate the design and improve the structural behavior and seismic performance of the SPSW systems. On this basis, this paper reports system-level investigations on the seismic response assessment of multi-story SPSW frames under the action of earthquake ground motions. The effectiveness of the strip model in representing the behaviors of SPSWs with different buckling and yielding properties is primarily verified. Subsequently, the structural and seismic performances of several code-designed and retrofitted SPSW frames with conventional and LYP steel infill plates are investigated through detailed modal and nonlinear time-history analyses. Evaluation of various seismic response parameters including drift, acceleration, base shear and moment, column axial load, and web-plate ductility demands, demonstrates the capabilities of SPSW systems in improving the seismic performance of structures and reveals various advantages of use of LYP steel material in seismic design and retrofit of SPSW systems, in particular, application of LYP steel infill plates of double thickness in seismic retrofit of conventional steel and code-designed SPSW frames.