• 제목/요약/키워드: neutrons

검색결과 309건 처리시간 0.025초

CEDM 구동용 전력변환회로 설계 검토 (Design Review of A Power Converter Topology for CEDM Driving)

  • 이종무;김춘경;천종민;박민국;권순만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1919-1920
    • /
    • 2006
  • This paper deals with the design review of a power converter topologies for CEDMCS (Control Element Drive Mechanism Control System). The CEDMCS provides the control signals and motive power to operate the CEDMS. The CEDM's raise and lower the CEAs (Control Element Assemblies) in the reactor core. The CEAs are constructed with the Boron-10 isotope which has a high microscopic cross section of absorption for thermal neutrons. This characteristic causes the addition of negative reactivity when a CEA is inserted and positive reactivity when it is withdrawn from the reactor core.

  • PDF

Relative Power Density Distribution Calculations of the Kori Unit 1 Pressurized Water Reactor with Full-Scope Explicit Modeling of Monte Carlo Simulation

  • Kim, Jong-Oh;Kim, Jong-Kyung
    • Nuclear Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.375-384
    • /
    • 1997
  • Relative power density distributions of the Kori Unit 1 pressurized water reactor are calculated by Monte Carlo modeling with the MCNP code. The Kori Unit 1 core is modeled on a three-dimensional representation of the one-eighth of the reactor in-vessel component with reflective boundaries at 0 and 45 degrees. The axial core model is based on half core symmetry and is divided into four axial segments. Fission reaction density in each rod is calculated by following 100 cycles with 5,000 test neutrons in each cycle after starling with a localized neutron source and ten noncontributing settle cycles. Relative assembly power distributions are calculated from fission reaction densities of rods in assembly. After 100 cycle calculations, the system converges to a k value of 1.00039 $\geq$ 0.00084. Relative assembly power distribution is nearly the same with that of the Kori Unit 1 FSAR. Applicability of the full-scope Monte Carlo simulation in the power distribution calculation is examined by the relative root moan square error of 2.159%.

  • PDF

중성자 회절을 이용한 용접부위의 잔류응력 측정 (Residual Stress Measurement on Welded Specimen by Neutron Diffraction)

  • 박만진;장동영;최희동
    • Journal of Welding and Joining
    • /
    • 제20권2호
    • /
    • pp.50-58
    • /
    • 2002
  • Residual stress is generated in the structures as a result of irregular elastic-plastic deformation during fabrication processes such as welding, heat treatment, and mechanical processing. There are several factors attributed to the origin of residual stresses, tensile or compressive. The stresses can be determined by destructive ways or nondestructive ways using X-ray or neutron diffraction. Although X-ray diffraction is a well established technique, it is practically limited to near-surface stresses. Neutrons penetrate easily into most materials and neutron diffraction permits non-destructive evaluation of lattice strain within the bulk of large specimens because the radiation is more deeply penetrating for metallic engineering components. This paper presented application of neutron diffraction technique to the residual stress measurement using 20 mm thick welded stainless steel plate($100{\times}100 \textrm{mm}^2$)

광섬유에 대한 열중성자 효과 연구 (A Study for the Thermal Heutron Effects on Optical Fiber)

  • 김웅기;손석원;이용범;이종민
    • 대한전자공학회논문지
    • /
    • 제27권12호
    • /
    • pp.1900-1905
    • /
    • 1990
  • In this study, the thermal neutron effects on optical fiber are examined theoretically. Also, the induced loss by thermal neutron irradiation in optical fibers is measured at the optical wavelengths of 0.85 and 1.3\ulcorner, respectively, and the results are analyzed. Thermal neutrons cause nuclear reaction with fiber compositions. So secondary ionizing radiations of high energy are generated. Color centers formed by these secondary ionizing rasiations increase transmission loss of optical fiber by absorbing propagating light in fiber core. As a result of experiment, owing to Ge, P, and B doping effects, the induced loss in multimode fibers has been 5 tmes larger than that in single mode fibers at 1.3 \ulcorner wavelengh. In case of multimode fibers, the loss at 0.8 \ulcorner wavelength region more suceptible for radiations has been twice higher than at 1.3\ulcorner.

  • PDF

DEVELOPMENT OF POSITION-SENSITIVE PROTON RECOIL TELESCOPE (PSPRT)

  • Miura, Takako;Baba, Mamoru;Kawata, Naoki;Sanami, Toshiya
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.161-165
    • /
    • 2001
  • We have developed a position-sensitive proton recoil telescope (PSPRT) which employs a position-sensitive photomultiplier (PS-PMT) and a scintillator for both a radiator and a proton-detector. This system is expected to achieve high energy resolution under a large solid angle, because it enables to obtain the information not only on the proton energy but also the recoil angle from the position data for both detectors. The response of the PSPRT for 14.1 MeV mono-energetic neutrons was measured, and the PSPRT proved to be operating as expected.

  • PDF

THIN-FILM-COATED DETECTORS FOR NEUTRON DETECTION

  • McGregor Douglas S.;Gersch Holly K.;Sanders Jeffrey D.;Klann Raymond T.;Lindsay John T.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.167-175
    • /
    • 2001
  • Semiconductor diode detectors coated with neutron reactive material are presently under investigation for various uses, such as remote sensing of thermal neutrons, fast neutron counting, and thermal neutron radiography. Theory indicates that single-coated devices can yield thermal neutron efficiencies from 4% to 11 %, which is supported by experimental evidence. Radiation endurance measurements indicate that the devices function well up to a limiting thermal neutron fluence of $10^{13}/cm^2$, beyond which noticeable degradation occurs. Thermal neutron contrast images of step wedges and simple phantoms, taken with dual in-line pixel devices, show promise for thermal neutron imaging detectors.

  • PDF

RADIATION SAFETY STUDIES AT TOHOKU UNIVERSITY CYRIC

  • Yamadera M. Baba A.;Miura T.;Aoki T.;Hagiwara M.;Kawata N.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.231-236
    • /
    • 2001
  • A brief introduction is presented on the radiation safety studies at Tohoku University Cyclotron & Radioisotope Center. Studies on two subject are described; (1) measurement of the thick target neutron yield and radioisotope production / activation cross section for ten's of MeV neutrons and ions using K=110 Tohoku University cyclotron to provide basicdata for accelerator shielding, and (2) development of techniques for high sensitive radiation detection and profile measurement using an Imaging Plate which is a high sensitive two-dimensional radiation sensor. Application of the Imaging Plate techniques to localization of very weak radioactivity and to neutron profile measurement is described.

  • PDF

NEUTRON FIELD OF THE EARTH, ORIGIN AND DYNAMICS

  • Kuzhevskij, B.M.;Nechaev, O.Yu.;Panasyuk, M.I.;Sigaeva, E.A.;Volodichev, N.N.;Zakharov, V.A.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.315-319
    • /
    • 2001
  • It is shown, that both cosmic radiation (external source) and natural radioactive gases (inner source) are sources of neutrons near the Earth crust. Correlation between the Earth crust dynamics and variations of thermal and slow neutron flux near the Earth surface is studied. It is shown, that variations of neutron flux near the Earth crust can be used for short-term predicting of natural hazards.

  • PDF

Measurement of Branching Ratio for broad 27-keV Resonance of $^{19}F(n,g)^{20}F$ Reaction by using Time-of-flight Method with Anti-Compton NaI(Tl) Spectrometer

  • Lee, Sam-Yol
    • 한국방사선학회논문지
    • /
    • 제2권1호
    • /
    • pp.31-34
    • /
    • 2008
  • The neutron capture spectrum for the light nuclide was very useful to study the nuclear structure. In the present study, the capture gamma-ray from the 27-keV resonance of $^{19}F(n,g)^{20}F$ reaction were measured with an anti-Compton NaI(Tl) spectrometer and the 3-MV Pelletron accelerator of the Research Laboratory for Nuclear Reactors at the Tokyo institute of technology. A neutron Time-of-Flight method was adopted with a 1.5 ns pulsed neutron source by the $^7Li(p,n)^7Be$ reaction. In the present experiment, a Teflon(($CF_2$)n) sample was used The sample was disk with a diameter of 90mm. The thickness of sample was determined so that reasonable counting rates could be obtained and the correction was not so large for the self-shielding and multiple scattering of neutrons in the sample, and was 5mm. The primary gamma-ray transitions were compared with previous measurement of Kenny.

  • PDF

원자로계측을 위한 박막중성자열전대의 시작 및 특성 (Fabrication and Characteristics of Thin-film Neutron Thermopile for Reactor Instrumentation)

  • 김동훈
    • 대한전자공학회논문지
    • /
    • 제9권5호
    • /
    • pp.1-5
    • /
    • 1972
  • 원자로제어를 위한 중성자열전대의 응답시간 단축을 목적으로 진실증착된 박막열전대를 이체하여 중성자열전대를 시작하였다. 이의 실험결과를 선열전대의 것과 비교하였으며, 열중성자속범위 neutrons/㎠/sec에서 좋은 선형특성을 가지고 있었다. 시작된 박막중성자숙전대를 사용하여 TRIGA MARK-II 원자로 노심에서의 열중성자속분포를 측정하였다.

  • PDF