• 제목/요약/키워드: neutrons

검색결과 307건 처리시간 0.018초

CZT 반도체 검출기를 활용한 중성자 및 감마선 측정과 분석 기술에 관한 연구 (A Study on the Technology of Measuring and Analyzing Neutrons and Gamma-Rays Using a CZT Semiconductor Detector)

  • 진동식;홍용호;김희경;곽상수;이재근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.57-67
    • /
    • 2022
  • CZT detectors, which are compound semiconductors that have been widely used recently for gamma-ray detection purposes, are difficult to detect neutrons because direct interaction with them does not occur unlike gamma-rays. In this paper, a method of detecting and determining energy levels (fast neutrons and thermal neutrons) of neutrons, in addition of identifying energy and nuclide of gamma-rays, and evaluating gamma dose rates using a CZT semiconductor detector is described. Neutrons may be detected by a secondary photoelectric effect or compton scattering process with a characteristic gamma-ray of 558.6 keV generated by a capture reaction (113Cd + 1n → 114Cd + 𝛾) with cadmium (Cd) in the CZT detector. However, in the case of fast neutrons, the probability of capture reaction with cadmium (Cd) is very low, so it must be moderated to thermal neutrons using a moderator and the material and thickness of moderator should be determined in consideration of the portability and detection efficiency of the equipment. Conversely, in the case of thermal neutrons, the detection efficiency decreases due to shielding effect of moderator itself, so additional CZT detector that do not contain moderator must be configured. The CZT detector that does not contain moderator can be used to evaluate energy, nuclide, and gamma dose-rate for gamma-rays. The technology proposed in this paper provides a method for detecting both neutrons and gamma-rays using a CZT detector.

EXPERIMENTAL ANALYSES OF SPALLATION NEUTRONS GENERATED BY 100 MEV PROTONS AT THE KYOTO UNIVERSITY CRITICAL ASSEMBLY

  • Pyeon, Cheol Ho;Azuma, Tetsushi;Takemoto, Yuki;Yagi, Takahiro;Misawa, Tsuyoshi
    • Nuclear Engineering and Technology
    • /
    • 제45권1호
    • /
    • pp.81-88
    • /
    • 2013
  • Neutron spectrum analyses of spallation neutrons are conducted in the accelerator-driven system (ADS) facility at the Kyoto University Critical Assembly (KUCA). High-energy protons (100 MeV) obtained from the fixed field alternating gradient accelerator are injected onto a tungsten target, whereby the spallation neutrons are generated. For neutronic characteristics of spallation neutrons, the reaction rates and the continuous energy distribution of spallation neutrons are measured by the foil activation method and by an organic liquid scintillator, respectively. Numerical calculations are executed by MCNPX with JENDL/HE-2007 and ENDF/B-VI libraries to evaluate the reaction rates of activation foils (bismuth and indium) set at the target and the continuous energy distribution of spallation neutrons set in front of the target. For the reaction rates by the foil activation method, the C/E values between the experiments and the calculations are found around a relative difference of 10%, except for some reactions. For continuous energy distribution by the organic liquid scintillator, the spallation neutrons are observed up to 45 MeV. From these results, the neutron spectrum information on the spallation neutrons generated at the target are attained successfully in injecting 100 MeV protons onto the tungsten target.

중성자와 감마선 중복 조사가 자주달재비 분홍돌연변이율에 미치는 영향 (Effects of Combined Irradiation of Neutrons and ${\gamma}$-Rays on the Pink Mutation Frequencies in Tradescantia)

  • 김진규;이영근;김재성;신해식;현성희
    • Journal of Radiation Protection and Research
    • /
    • 제25권2호
    • /
    • pp.67-73
    • /
    • 2000
  • 자주달개비 식물체에 감마선과 중성자를 중복 조사하였을 패 나타나는 수술털(TSH) 분흥돌연변이율의 변화를 분석하였다. 감마선은 $0{\sim}2$ Gy의 범위에서 선량별 조사를 하였으며 중성자는 $^{252}Cf$ 선원으로부터 일정한 거리에 식물체를 배열하여 조사하였다. 감마선을 선량별로 조사한 후 중성자를 조사한 때의 TSH 분홍돌연변이 감마선량-반응의 증가계수는 6.17로 감마선량-반응식의 5.98에 비해 12%의 방사선효율 증가를 초래했으며 중성자를 먼저 조사한 다음 감마선을 조사한 경우는 증가계수가 7.48로서 25%의 방사선 생물효율 증대가 나타났다. 두 종류의 방사선 중복 조사시 조사방식의 선 후 조합에 따른 방사선생물효율 증대가능성은 멸균 또는 세포사멸 등 방사선을 긍정적으로 이용하는 분야에 있어 매우 중요한 의미가 있다.

  • PDF

Panasonic UD-809P 알비도 열형광선량계를 이용한 중성자 개인선량당량 평가 (Neutron Personal Dose Equivalent Evaluation Using Panasonic UD-809P Type TLD Albedo Dosimeters)

  • 신상운;손중권;김화
    • Journal of Radiation Protection and Research
    • /
    • 제24권3호
    • /
    • pp.143-154
    • /
    • 1999
  • Panasonic UD-809P 알비도 중성자 열형광선량계를 팬텀에 장착시켜 원자력발전소에서 중성자 개인선량당량을 측정하였다. 측정된 판독값으로부터 Panasonic 사의 사용자 매뉴얼에 제시되어 있는 방법을 이용하여 열중성자와 초열중성자 및 속중성자로 인한 개인선량당량을 평가하였다. 그 결과 열중성자 성분의 비율이 높은 원자력발전소에서는 속중성자로 인한 개인선량당량을 적절하게 평가할 수 없는 것으로 확인되었는데, 이는 열중성자로 인한 알비도 성분이 열형광선량계로 재입사 되는 양이 이론적인 값과 상당한 차이가 나기 때문인 것으로 추정되었다. 따라서 원자력발전소와 같이 열중성자 성분의 비율이 높은 조건에서 속중성자로 인한 중성자 개인선량당량을 평가하기 위하여 중성자 성분을 열중성자와 속중성자로 구분한 새로운 중성자 선량계산 알고리즘을 제안하였으며, 각각의 성분에 대한 개인선량당량과 교정인자, 민감도 인자 평가공식을 유도하였다.

  • PDF

Fabrication of a superheated emulsion based on Freon-12 and LiCl suitable for thermal neutrons detection

  • Sara Sadat Madani Kouchak;Dariush Rezaei Ochbelagh;Peiman Rezaeian;Majid Abdouss
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1425-1430
    • /
    • 2024
  • This study develops superheated emulsion detectors that are both sensitive to fast neutrons, and thermal neutrons owing to the exergonic 63Li(n, α)31H capture reaction caused by the 6Li-containing compound dispersed throughout the gel-like medium. The experimental research was conducted on two SEDs. One detector was an ordinary Freon-12 detector and the other was a Freon-12 detector containing 3.4 % (by weight) LiCl. In order to investigate the sensitivity of lithium-containing SEDs to thermal neutrons, two types of SEDs were simultaneously exposed to various flux levels of thermal neutrons from 241Am-Be neutron source inside a cylindrical tank filled with water. A Boron-lined proportional counter was used to estimate the thermal neutron flux and the relevant MCNP code was developed for flux and dose calculations in the prepared set-up around 241Am-Be source. The results demonstrate that there is a proportional relationship between the variations of SED response and the change in thermal neutron flux and dose. Also, the sensitivity of SED was estimated.

Digital n-γ Pulse Shape Discrimination in Organic Scintillators with a High-Speed Digitizer

  • Kim, Chanho;Yeom, Jung-Yeol;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.53-63
    • /
    • 2019
  • Background: As neutron fields are always accompanied by gamma rays, it is essential to distinguish neutrons from gamma rays in the detection of neutrons. Neutrons and gamma rays can be separated by pulse shape discrimination (PSD) methods. Recently, we performed characterization of a stilbene scintillator detector and an EJ-301 liquid scintillator detector with a high-speed digitizer DT5730 and investigated optimized PSD variables for both detectors. This study is for providing a basis for developing fast neutron/gamma-ray dual-particle imager. Materials and Methods: We conducted PSD experiments using stilbene scintillator and EJ-301 liquid scintillator and evaluated neutron and gamma ray discriminability of each PSD method with a $^{137}Cs$ gamma source and a $^{252}Cf$ neutron source. We implemented digital signal processing techniques to apply two PSD methods - the charge comparison (CC) method and the constant time discrimination (CTD) method - to distinguish neutrons from gamma rays. We tried to find optimized PSD variables giving the best discriminability in a given experimental condition. Results and Discussion: For the stilbene scintillator detector, the charge comparison method and the constant time discrimination method both delivered the PSD FOM values of 1.7. For the EJ-301 liquid scintillator detector, both PSD methods delivered the PSD FOM values of 1.79. With the same PSD variables, PSD performance was excellent in $300{\pm}100keVee$, $500{\pm}100keVee$, and $700{\pm}100keVee$ energy regions. This result shows that we can achieve an effective discrimination of neutrons from gamma rays using these scintillator detector systems. Conclusion: We applied both PSD methods to a stilbene and a liquid scintillator and optimized the PSD performance represented by FOM values. We observed a good separation performance of both scintillators combined with a high-speed digitizer and digital PSD. These results will provide reference values for the dual-particle imager we are developing, which can image both fast neutrons and gamma rays simultaneously.

10MV X선 방사선 치료 시 중성자 선량 분포에 관한 연구 (A Study on the Neutron Dose Distribution in Case of 10 MV X-rays Radiotherapy)

  • 박철수;임청환;정홍량;신성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.415-417
    • /
    • 2008
  • 현재 방사선치료는 선형가속기에 의하여 대다수 이루어지고 있으며 사용되는 방사선인 광자도 의학의 발전에 의해 고에너지화 고선량화 되고 있다. 본 연구에서는 방사선치료 조사면에서 중성자 측정이 가능한 CR-39를 이용한 중성자 검출법을 이용하였다. 선형가속기에서 발생되는 X선(광자)치료 시 발생 되는 중성자의 선량을 CR-39를 이용한 중성자 검출법을 이용하여 측정하고, 임상적 응용으로 고에너지 광자를 이용하여 암 치료에 사용할 때 중성자의 발생이 환자치료 선량과 연관되는 어떤 문제를 발생시키는지를 연구한 결과는 다음과 같다. 속중성자의 경우 광자 1Gy 조사 시 평균 0.35mSv, 2Gy 조사 시 평균 0.65mSv, 5Gy 조사 시 평균 1.82mSv, 열중성자의 경우 광자 1Gy 조사 시 평균 0.26mSv, 2Gy 조사 시 평균 0.56mSv, 5Gy 조사 시평균 1.23mSv의 중성자 발생하였다. Wedge Filter를 사용하여 중성자의 발생을 측정한 결과 Wedge Filter를 사용했을 때 중성자의 발생이 증가하였다. 고선량을 요구하는 SRS Cone을 사용했을 때에는 기존의 실험결과 보다 많은 중성자가 검출되었다. 속중성자의 경우 광자 5Gy 조사 시 평균 2.85mSv, 열중성자의 경우 광자 5Gy 조사 시 평균 1.37mSv의 중성자가 발생하였다. 일반 치료 시 광자 5Gy 조사했을 때 보다 속중성자의 경우 약 1.6배, 열중성자의 경우 약 1.12배 정도의 중성자가 더 발생하는 것으로 나타났다.

  • PDF

Neutron Dosimetry and Monitoring in the Radiation Environment

  • Nakamura, Takashi
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.51-62
    • /
    • 1989
  • The high efficiency moderated-type neutron spectrometer and doseequivalent counter were developed for the measurement of low level environmental neutrons. By using these detectors, the neutron energy spectra and dose equivalent rates due to skyshine effect were measured in the environment surrounding the accelerator facilities and also the altitude variation of cosmic ray neutrons in the aircraft flying over Japan.

  • PDF

Optimization of shielding to reduce cosmic radiation damage to packaged semiconductors during air transport using Monte Carlo simulation

  • Lee, Ju Hyuk;Kim, Hyun Nam;Jeong, Heon Yong;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1817-1825
    • /
    • 2020
  • Background: Cosmic ray-induced particles can lead to failure of semiconductors packaged for export during air transport. This work performed MCNP 6.2 simulations to optimize shielding against neutrons and protons induced by cosmic radiation Methods and materials: The energy spectra of protons and neutrons by incident angle at the flight altitude were determined using atmospheric cuboid model. Various candidates for the shielding materials and the geometry of the Unit Load Device Container were evaluated to determine the conditions that allow optimal shielding at all sides of the container. Results: It was found that neutrons and protons, at the flight altitude, generally travel with a downward trajectory especially for the particles with high energy. This indicated that the largest number of particles struck the top of the container. Furthermore, the simulation results showed that, among the materials tested, borated polyethylene and stainless steel were the most optimal shielding materials. The optimal shielding structure was also determined with the weight limit of the container in consideration. Conclusions: Under the determined optimal shielding conditions, a significantly reduced number of neutrons and protons reach the contents inside the container, which ultimately reduces the possibility of semiconductor failure during air transport.

Change in radiation characteristics outside the SNF storage container as an indicator of fuel rod cladding destruction

  • Rudychev, V.G.;Azarenkov, N.A.;Girka, I.O.;Rudychev, Y.V.
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3704-3710
    • /
    • 2021
  • The characteristics of the external radiation on the surface of the casks for spent nuclear fuel (SNF) storage by dry method are investigated for the case when the spatial distribution of SNF in the basket changes due to the destruction of the fuel rod claddings. The surface areas are determined, where the changes in fluxes of neutrons, produced by 244Cm actinide, and γ-quanta, produced by long-lived isotopes, are maximum in the result of the decrease in the height of the SNF area. Concrete (VSC-24) and metal (SC-21) casks are considered as examples. The procedure of periodic measurement of the dose rate of neutrons or γ-quanta at the specified points of the cask surface is proposed for identifying the fuel rod cladding destruction. Under normal operation, the decrease in the dose rate produced by neutrons as the function of SNF storage duration is determined by the half-life of 244Cm, and for γ-quanta - by the half-lives of long-lived SNF isotopes. Consequently, a stepwise change in the dose rate of neutrons or γ-quanta, detected by the measurements, as compared to the previous one, would indicate the destruction of the fuel rod claddings.