• 제목/요약/키워드: neutral response

검색결과 243건 처리시간 0.025초

효율향상을 위한 폐수처리용 2 Vane 펌프 설계 최적화 (Design Optimization on 2 Vane Pump of Wastewater Treatment for Efficiency Improvement)

  • 김성;마상범;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.277-284
    • /
    • 2021
  • This paper deals with multi-objective optimization using response surface method to improve the hydraulic performances of a 2 vane pump for wastewater treatment. For analyzing the internal flow field in the pump, steady Reynolds-averaged Navier-Stokes equations were solved with the shear stress transport turbulence model as a turbulence closure model. The impeller and volute variables were defined in the shape of the 2 vane pump. The objective functions were set to satisfy the total head at the design flow rate as well as to improve the efficiency. The hydraulic performance of the optimally designed shape was verified by numerical analysis results.

Polymeric Acetate-Selective Electrodes Based on meso-(α,α,α,α)-Tetrakis-[(2-arylphenylurea)phenyl]porphyrins: Electormic and pH Effects

  • Lee, Hyo-Kyoung;Song, Ki-ju;Seo, Hyung-Ran;Jeon, Seung-won
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권10호
    • /
    • pp.1409-1412
    • /
    • 2002
  • Polymeric membrane electrodes for acetate anion based on meso-(${\alpha}$,${\alpha}$,${\alpha}$,${\alpha}$)-5,10,15,20-tetrakis[2-(penta-fluorophenylurea) phenyl]porphyrin I and similar urea-functionalized porphyrins Ⅱ-Ⅳ as neutral ionophores were prepared. The membrane based on porphyrin I exhibits the best potentiometric properties in pH 6.0 rather than pH 7.0: linear stable response over a wide concentration range (6.0 ${\times}$$10^{-5}$-1.0 ${\times}$$10^{-2}$) with a slope of -59.6 mV/decade and a detection limit of log[CH3CO$O^-$] = -5.32. Selectivity coefficients obtained from the matched potential method (MPM) in pH 6.0 indicate that interferences of hydrophobic anions are very small for the membranes of porphyrins I and II having the strong withdrawing group. The electronic effect of urea-functionalized porphyrins and pH effect of buffer solutions are discussed on the potentiometric response.

Potentiometric Characteristics of Ion-Selective Electrodes Based on Upper-Rim Calix[4]crown Neutral Carrier

  • 강유라;오현준;이경문;차근식;남학현;백경수;임혜재
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권2호
    • /
    • pp.207-211
    • /
    • 1998
  • Potentiometric characteristics of DOS plasticized PVC-based membranes containing upper-rim calix[4]crown neutral carrier to various metal cations and protonated alkylamines have been examined. Although the calix[4]crown-based membrane electrodes exhibited substantial emf responses to alkali and alkaline earth metal cations, their high detection limits (- log[Cs+]=4.5) and sub-Nernstian response slopes (48 mV/pCs+) to the most selective cation, cesium, indicate that the metal cation complexing ability of calix[4]crown is much weaker than that of macrocyclic crown ethers. However, the calix[4]crown-based membrane electrodes exhibited near-Nernstian response slopes (56 mV/decade for hexylNH3+) with low detection limits (log[hexylNH3+]= - 6.7) to most alkylammonium ions compared to those of blank (DOS plasticized PVC membrane with no ionophore) or crown ether-based membranes. While the selectivity patterns of blank and crown ether-based membranes are determined primarily by the lipophilicity of alkylammonium ions, the membranes doped with calix[4]crown ionophore could effectively discriminate the steric shapes of nonpolar alkyl groups of alkylammonium ions.

고양정 및 저유량을 만족하는 폐수처리용 펌프 설계 최적화 (Design Optimization on Wastewater Treatment Pump of Satisfaction for High Head and Low Flow Rate)

  • 김성;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.583-590
    • /
    • 2022
  • In this paper, the performance characteristics of the 2 vane pump for wastewater treatment were investigated using response surface method(RSM) with commercial computation fluid dynamics(CFD) software. Design variables of wastewater treatment pump were defined with the meridional plane of the 2 vane pump impeller. The objective functions were defined as the total head and the efficiency at the design flow rate. The hydraulic performance of optimum model was verified by numerical analysis and the reliability of the model was retained by comparison of numerical analysis and comparative analysis with the reference model.

이온 선택성 전극을 이용한 의약품 정량: Calix[4]arene과 Dibenzo-18-crown-6-ether에 의한 verapamil-선택성 polymeric membrane electrode (Ion-Selective Electrodes in Drugs Analysis: Verapamil-Selective Polymeric Membrane Electrodes Based on Calix[4]arene and Dibenzo-18-crown-6-ether Ionophores)

  • 이은엽;김성진;김영학;김재현;허문회;안문규
    • 약학회지
    • /
    • 제39권1호
    • /
    • pp.61-67
    • /
    • 1995
  • PVC membrane electrodes based on the lipophilic neutral carrier, dibenzo-18-crown-6, cyclic oligomers of teit-butylphenol-formaidehyde condensates, calix[4]arenes as the active sensors for verapamil have been prepared and tested in a variety of plasticizers. At pH 5.0, the electrode exhibits a Nernstian response in the range of 10$^{-2}$~5$\times$10$^{-5}$ M verapamil with a slope of 49.1$\pm$0.5mV per concentration decade. The electrode constructed in this work can be used continuously for at least 1 month before any damage to the membrane occurs. And the analyses of the local anesthetic amine, which are good to select a specific compound in a mixed solution, were also accomplished by using of another neutral carrier, a DB18C6, for comparing with calix[4]arene.

  • PDF

현장시험에 의한 중성선 고조파 해석용 접지 임피던스 모델링 (The Ground Impedance Modeling for Neutral Harmonic Analysis by Field Tests)

  • 김경철;백승현;최종기;이일무;김종욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.369-371
    • /
    • 2004
  • With the proliferation of nonlinear loads, high neutral harmonic currents in three-phase four-wire distribution system have been observed. It has been. known that the ground impedance has an effect on the neutral currents of a system which operates with harmonics present. On-site measurements of harmonic currents and voltages according to the fell-of-potential method under case study system were made and the ground impedance modeling using the pattern search method for the harmonic analysis was developed. The ground impedance model obtained by the proposed method was compared with the frequency characteristics by field tests and has shown appropriate results, and would be applicable to evaluate the harmonic and transient response characteristics of the ground system.

  • PDF

창원시 탄소중립마을 사업평가를 통한 지속가능한 주민참여형 탄소중립마을 활성화 방안 연구 (Study on Activating a Sustainable Carbon-neutral Community through Resident Participation based on the Evaluation of Changwon City's Carbon-neutral Village Project)

  • 장유미;이승준
    • 문화기술의 융합
    • /
    • 제9권3호
    • /
    • pp.569-577
    • /
    • 2023
  • 본 연구는 창원시 전체 5개 행정구 모두가 포함되고 각 지역 특성을 고려한 7곳의 탄소중립마을을 선정하여 해당 지역주민과 설문조사와 리더의 FGI를 통한 사업평가를 바탕으로 활성화 방안을 제안하였다. 분석결과 탄소중립마을 활성화를 위해 가장 중요한 것으로 17개 문항을 복수 응답한 결과 탄소중립 교육이 91.9%로 가장 중요하다고 응답하였고, 사업을 진행하면서 마을의 정체성과 관련된 목표의식과 가치추구가 중요하다가 89.1%를 차지하였으며, 법적(조례) 마련 79.3%, 마을조직 구축 74.1%의 순으로 나타났다. 이를 통해 창원시에서 탄소중립마을 만들기 사업에 참여하는 주민들을 통한 활성화 방안은 다음과 같다. 첫 번째로, 탄소중립 마을별로 자원순환 중심형 모델, 환경조성 중심형 모델, 환경교육과 체험행사 중심형 모델, 에너지 효율 중심형 모델로 구분되어 그 특징이 나타났다. 두 번째로, 탄소중립마을의 성장을 위해 탄소중립마을 성장 단계 가이드라인을 만들어 제시하는 것이 필요하다. 세 번째로, 마을 자치로 운영되기 위해서는 리더와 활동가들이 쉽게 적용하고 접근할 수 있는 탄소중립 관련 이론, 이슈, 실천 등의 매뉴얼 및 교안을 제작하여 배포하는 것이 필요하다. 네 번째로, 창원시에 법적으로 설치가 가능한 탄소중립지원센터가 설립된다면, 지역주민의 삶이 기후 위기에 대비하여 탄소중립생활이 더욱 지속 가능할 것으로 기대한다.

Corporate Strategies for Responding to Negative Comments on Restaurant Pages on Facebook

  • Song, Ja-Hyun;Kim, Hyun-Jung
    • 한국조리학회지
    • /
    • 제22권6호
    • /
    • pp.61-70
    • /
    • 2016
  • The purpose of this study is to identify the effects of a company's response strategies (response type, communication style, and response sincerity) on customer's brand attitude and purchase intentions. A fictional Facebook fan page containing 6 separate scenarios was developed based on actual customer reviews and company responses observed on Facebook restaurant fan pages. Participants were recruited from Amazon's Mechanical Turk (MTurk). A total of 202 responses were obtained; 185 responses were analyzed after deleting insufficient responses. The results of MANOVA found that an accommodative response leads customers to have a more favorable attitude towards a brand and have stronger purchasing intentions. In addition, customers who perceive the company's response to a negative review as sincere are more likely to have a positive brand attitude and purchasing intentions, as compared to those who perceive it as either insincere or neutral.

물방울패턴이 원피스드레스 착용자의 이미지에 미치는 영향 -무채색 배색을 중심으로- (The Effect of Dot Pattern on Dress's Wearer Image -On the Neutral coloration-)

  • 김선미;강경자
    • 한국생활과학회지
    • /
    • 제16권2호
    • /
    • pp.407-419
    • /
    • 2007
  • The purpose of this study was to identify the effect of four clothing cues dot pattern size and ground field of color area ratio on dress's wearer image. The experimental materials developed for this study are a set of stimuli and response scales(The 7-point semantic). The stimuli were 30 color pictures manipulated with the combination of dot pattern size, dot pattern on background of color area ratio and neutral dress's using computer simulation. The subjects were 180 female undergraduates living students in Gyeong-nam. The result of this study are as follows: Image factor of the stimulus was composed of 5 different components (visibility, gracefulness, attractiveness, cuteness, womanly). Especially, Neutral color combination independently influenced the every components. In regarding the effect of interaction between each variable, the combination of dot pattern on background of color area ratio, dot pattern size on the combination had cuteness, womanly.